Health and Family Welfare Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47587229

Tender For Cath Lab Consumables Purchase Items

Issued by Statutory Bodies & Commissions/Committees · pathanamthitta, Kerala
Tender Value
1 Crore
Estimated cost
Bid Submission
19 Feb 2025
0 days left
EMD
30000
Bank guarantee accepted
Document Fee
16000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
pathanamthitta → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Cath Lab Consumables Purchase Items-- 1 Radial sheath with nitinolguide wire,4F- 6F/ length 5-7cm - wire length 45cm, wire dimension0.025 2 Radial sheath with nitinolguide wire, 6F/ length 7cm - wire length 45cm, wire dimension0.025 3 Radial Sheath with ultra thin wall technology resulting 1 fr size outer diameter reduction.5Fr, 6Fr, 7Fr with 10/16 cm length 4 Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.025, 5 Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.021, 6 Radial sheath 5& 7.5cm long,Size-4-6F, length – 5 & 7.5cm, guidewire-0.021 7 PMDA / USFDA approved 5F - 11 Fr; 7cm long, 0.035-0.038 compactable radial sheath, include surflash 20G x 2 emtry needle and 0.025 mimi plastic guide wire, ETFE sheath tubing, dilator tube should made up of polypropylene and should have silicon coating. Should contain haemostatic crosscut valve to prevent back leack of blood and aspiration of air; with intregated side arm with attached 3 way stopclock and have suture eye; kink resist; with dilator - hub lock mechanism. 8 PMDA / USFDA approved 5 - 11 Fr; 10-16-25cm long; 0.021 or 0.025 inch guide wire compactable. Sheath tube made up of ETFE, cross cut valve should be made up of silicon rubber & should have silicon coating. Have haemostaitc crosscut valve; integrated side arm with attached 3-way stopclock; with suture eye; kink resistant. dilator hub lock mechanism to prevent back out during insertion; pack mudt include with or with out metalic tube. 9 TS femoral sheath: 11 cm long Input TS femoral sheath with 0.038 inch guide wire,6f 10 TS femoral sheath: 23 cm long Input TS femoral sheath with 0.038 inch guide wire,6f 11 Femoral Sheath-Adult 0.035 inch Guide wire,4-9 F size 12 25cm long, Size femoral sheath size ranging from6f,with guide wire 13 24 cm long Femoral Sheath with 0.018-0.038 inch straight tip guide wire,3-9 F 14 25 cm long femoral sheath without guide without wire but compatible with 0.038 wire,10-14 F 15 13-80 cm long, Large Valve femoral sheath,9-18 F 16 5.5-23 cm long, Radial sheath with 0.018 inch guide wire,4-6 F 17 5-45 cm long, small Valve femoral sheath,4-8 F 18 90 cm long, Brite Tip interventional sheath ,4-11 F 19 femoral sheeth 11 cm long Size ranging from 6F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking. 20 femoral sheeth 11 cm long Size ranging from 7F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking. 21 Cross over sheathfor peripheral intervention , 0.038 wire compactable. Size 5.5 Fr - 8Fr, Length 40cm 22 Hydrophilic guide wire, black,(0.018 - 0.038 X 80 CM - 1260CM), angled /straight tip type 23 Hydrophilic guide wire, black,(,0.35, 150 cm ), angled /straight tip type 24 Hydrophilic guide wire, black,(,0.35, 260 cm ), angled /straight tip type 25 Baby J wire with 1.5mm J tip, super elastic nitinol alloy, M coat hydrophilic coat, one piece construction for one to one troque and radiopaque polyurethane jacket. 26 Angio guide wire 0.035 hydrophilic coated spring coil 65cm or more, double coil structure, distal 15cm is silicon coated , hybrid shaft design ACTONe on proximal shaft usable length 150cm, 180cm, 200cm, 220cm, 260cm, 300cm both angled tip & J shape. 27 TERUMO type Hydrophilic guide wire,0.35x150, angled /straight tip type 28 TERUMO type Hydrophilic guide wire,0.35x260, angled /straight tip type 29 TERUMO type Hydrophilic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type 30 150cm Hydrophilic guide wire, blue,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 31 Exchange length Hydrophilic guide wire, blue,(0.018 - 0.038 X 260 CM), angled /straight tip type 32 Diagnostic guide wire single length ,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 33 PTFE coated guidewire:(0.035 X 150cm ), angled /straight tip type 34 PTFE coated guidewire:(0.035 X 260cm ), angled /straight tip type 35 Diagnostic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type 36 PTFE coated guidewire,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 37 PTFE coated guidewire,(0.018 - 0.038 X 260 CM), angled /straight tip type 38 AMPLATZ WIRE,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 39 AMPLATZ WIRE,Lengths- 150cm, Tip - Straight/shapable, 0.035” 40 AMPLATZ WIRE,super stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 41 AMPLATZ WIRE,super stiff,Lengths- 150cm, Tip - Straight/shapable, 0.035” 42 AMPLATZ WIRE,extra stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 43 AMPLATZ WIRE,extra stiff,Lengths- 150cmcm, Tip - Straight/shapable, 0.035” 44 Hydrophilic coating for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032 - 0.038, length 150 - 260cm, Types avaliable angled and stright. DCGI approved. 45 Hydrophilic coating, PTFE coated for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032 - 0.038, length 150 - 260cm, Types avaliable angled and stright. DCGI approved. 46 0.035 diameter peripheral wire Stright tip, length 180, 260cm 47 Straignt hub , FEP polymer , radio opaque , 16-20 G , puncture needle 48 Puncture needle(radial) – cook model, 49 Puncture needle(16G, 18G, 7cm, 20cm) 50 Puncture needle(20G, 21G, 4cm) 51 Micro puncture needle 52 Tiger curve catheter,5F-6F / 100 cm, side hole 1, 3 curved 53 PMDA / USFDA approved TIG Catheter, 100cm 54 PMDA / USFDA approved TIG Catheter, comprised of a two layer construction , double braided stainlesss-steel two-polymer mesh sandwiched between layers of polyurethane ad polymide elastomers. Must have 32 strands of stainless steel braid, the shaft inner layer and outer layer contain barium sulphate. Anti kinking protector, with non-braided tip shaft (distal 2cm). 4F - 6F size and 100cm long. 55 Tiger curve diagnostic catheter for brachial angiogram, size 5F-6F / 100 cm,,5f-6F / 100 cm, 56 TIG4,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm, 57 TIG4.5,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm, 58 TR4(tiger curve) Guide catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery, 59 Pigtail,5F & 6F / Lengths 100, 110 & 125cm, Side holes 6 & 12 60 Angled pigtail catheter,5F & 6F, Curves145& 155, Lengths 100,110 &125cm, Side holes 6 & 12 61 GLIDECATH HYDROPHILIC CATHETER, 5F-6F / 100 cm,125CM 62 Multipurpose(MPA1,A2,B1,B2) diagnostic catheter ,5F-6F / 100 cm, 63 Amplatz Catheter Left/Right-AR/AL1,2 diagnostic catheter,5F-6F / 100 cm, 64 Judkins right and left diagnostic catheter (JR/JL),4F-7F / 100 cm, 125 cm 65 Mother and child catheter - size – 5F-8F/length 25cm ,5F-8F, Rapid Exchange Length 25 -cm 66 Mother and child catheter Size – 6F/extension length 15cm 67 NTR( no torque right) catheter,useful for engaging anteriorly angulated bypass graft(including LIMA from the left radial approch& RIMA from the femoral approach) 68 Special Radial angiographic catheters, 1:1 torque control with large lumon, Coaxial alignment and soft tip, Nylon and polyurethane inner and outer layerDouble braided stainless steel Middel layer, 100 & 110cm Length 69 4F,5F,6F Diagnostic Right catheter 110cm - 125 cm 70 4F,5F,6F Guiding Right catheter 110cm- 125 cm 71 Microcatheter 72 Ordinary Handle gun type inflation device,-Pressure: 0-30, 73 Inflation device,piston handle type intra-cam locking mechanism,Barrel volume-20ml, Pressure range: 0-30 74 High pressure inflation device piston handle with finger latch mechanism,Barrel volume- 20ml, 0-30 75 FDA Approved Inflation Device with 20 to 30 Atmosphere, gun type 76 inflation device Maximum Pressure of 30 atm, 20ML clear syringe barrel with smooth moving plunger,self locking mechanism for easy locking as well as gradual and rapid pressure release Ergonomic handle and Precision manometer. 77 Silicon valve material type Y connector,Bonded extension tube length 20cm, Push-pull type hemostatic valve 78 Ordinary Y Connector,Bonded extension tube, Push-pull type hemostatic valve 79 Rotating Y connector with 2 way adjustable valve,Rotating Y-connector/2-way adjustable valve 80 Rotating double Y connector with 3 way adjustable valve,Rotating double Y-connector/3-way adjustable valve 81 High pressure resistance Y connector ,Pressure resistance of atleast 8 atm, push pull type, inner lumen diameter-0.025”,Guidewire compatibility – 0.010” - 0.014” 82 PTCA Y connector 400 Kpa leak-proof seal from proprietary designed valve,open and close by twisting,7F-9f compatible lumen allowing delivery of wide range of devices and torque and introducer fit 0.014-0.021 guide wire. 83 DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool. 84 DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool. 85 2 port &3 port DCGI approved manifold. Smooth turning handles, transprarent body visual control, up to psi pressure stability for manual injectionpsi - psi, Right on/off. 86 3 port manifold,Right port, halfbody,with on/off handle 87 3 port manifold,Right port, halfbody,Righton/off handle 88 2.3 - 3F size Coronary microsnare,Length 150 , 175cm 89 3.2F size coronary snare,Length-150 cm 90 4,6F size coronary snare,Length- 102 cm 91 6-7 F size coronary snare,Length- 100 cm 92 5 F, 6FFlow directed temporary pacing lead with balloon,8 mm balloon, length 110cm 93 5F, 6F Ordinary temporary pacing lead110cmlong ,2mm bipolar electrodes 94 5F Ordinary temporary pacing lead,Length-105cm, 110cm, electrode spacing-15mm,25mm 95 5F,6F,7F, temporary pacing lead,100, 125cm, bipolar 96 COVERED STENT 97 Contrast media- Iohexol ,100ml (300/350mg Iodine/ml) 98 Contrast media (Dimer)- Iodixanol,100ml (300/350mg Iodine/ml) 99 Contrast media- Iohexol ,50-100ml(300/350mg Iodine/ml) 100 Non - ionic contrast medium in sterile aqueous solution for interventional procedures. Iohexol - 350mg I / ml. Osmolalities from 2.2 - 3. 101 Non - ionic, isosmolar contrast medium in sterile aqueous solution for interventional procedures. Iodixanol - 320mg I / ml. Osmolalities from 2.2 - 3. 102 ETO Reel Size:- 10cm, Length :- 200m 103 ETO Reel Size:- 15cm, Length :- 200m 104 ETO Reel size :- 30cm, Length :- 200m 105 ETO gas cartilage - Compactable to 3M Steri-Vac GS5 106 ETO Chemical Indicator 107 Presure injector syringe 150 ml,MEDRAD Arterion mark 7 compatible 108 Angiogram Kit 109 Angiography kit pack with collection pouch 110 Single surgeons gown 111 ECG electrode 3M 112 Doc extention for PTCA guide wire. 113 Inj.Nikorandil 48mg 114 Inj.Tirofiban 115 Inj.Heparin 116 Inj.Low Molicular weight heparin 117 Ventilator Mask (Large &Medium) 118 Tab.Ticagrelor 90 mg 119 IV Set (vented) 120 PMO Line 200cm 121 Lure Lock syringe 10 cm 122 Drug eluting balloon.Balloon size: 1.5mm – 6 mm / Length: 10 mm -250mm 123 Cutting balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm 124 Scoring balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm 125 135 cm Thrombus Aspiration Catheter,Outer diameter: 3.9-5.4F 126 140 cm Thrombus Aspiration Catheter,Outer diameter: 3.9F 127 Thrombus Aspiration Catheter with hydrophilic coating,Sizes – 6-8F, length-140cm, internal diameter – 0.070” – 0.86” 128 Thrombus Aspiration Catheter with braided technology,Catheter length 145cm, maximum tip diameter - 1.73, 1.98, Guide catheter - 6, 7F 129 Scoring balloon catheter:Catheter type: rapid exchange / Guidewire lumen diameter:0.014/Material: nylon blend/Balloon compiance: Non Compliant /Crossing profile:0.0313/.0.79 mm/ Coating(distal shaft and tip): hydro x hydrophilic coating / Coating (guidewire lumen): invio hydrophobic / NBP: 12 atm / RBP: 20 atm/Available Diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / Available length (in mm):10, 15, 20 / USFDA / CE approved 130 Guide extention catheter 6F/7F 131 Sirolimus Drug coated ballooncatheter. Size 1.5 mm- 4mm, length 10mm-40mm.

BOQ

Name of Work: CATH LAB CONSUMABLES : PURCHASE ITEMS
Sl. No. Item Description
1Radial sheath with nitinolguide wire,4F- 6F/ length 5-7cm - wire length 45cm, wire dimension0.025
2Radial sheath with nitinolguide wire, 6F/ length 7cm - wire length 45cm, wire dimension0.025
3Radial Sheath with ultra thin wall technology resulting 1 fr size outer diameter reduction.5Fr, 6Fr, 7Fr with 10/16 cm length
4Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.025,
5Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.021,
6Radial sheath 5& 7.5cm long,Size-4-6F, length – 5 & 7.5cm, guidewire-0.021
7PMDA / USFDA approved 5F - 11 Fr; 7cm long, 0.035-0.038 compactable radial sheath, include surflash 20G x 2 emtry needle and 0.025\"\" mimi plastic guide wire, ETFE sheath tubing, dilator tube should made up of polypropylene and should have silicon coating. Should contain haemostatic crosscut valve to prevent back leack of blood and aspiration of air; with intregated side arm with attached 3 way stopclock and have suture eye; kink resist; with dilator - hub lock mechanism.
8PMDA / USFDA approved 5 - 11 Fr; 10-16-25cm long; 0.021 or 0.025 inch guide wire compactable. Sheath tube made up of ETFE, cross cut valve should be made up of silicon rubber & should have silicon coating. Have haemostaitc crosscut valve; integrated side arm with attached 3-way stopclock; with suture eye; kink resistant. dilator hub lock mechanism to prevent back out during insertion; pack mudt include with or with out metalic tube.
9TS femoral sheath: 11 cm long Input TS femoral sheath with 0.038 inch guide wire,6f
10TS femoral sheath: 23 cm long Input TS femoral sheath with 0.038 inch guide wire,6f
11Femoral Sheath-Adult 0.035 inch Guide wire,4-9 F size
1225cm long, Size femoral sheath size ranging from6f,with guide wire
1324 cm long Femoral Sheath with 0.018-0.038 inch straight tip guide wire,3-9 F
1425 cm long femoral sheath without guide without wire but compatible with 0.038 wire,10-14 F
1513-80 cm long, Large Valve femoral sheath,9-18 F
165.5-23 cm long, Radial sheath with 0.018 inch guide wire,4-6 F
175-45 cm long, small Valve femoral sheath,4-8 F
1890 cm long, Brite Tip interventional sheath ,4-11 F
19femoral sheeth 11 cm long Size ranging from 6F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
20femoral sheeth 11 cm long Size ranging from 7F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking.
21Cross over sheathfor peripheral intervention , 0.038 wire compactable. Size 5.5 Fr - 8Fr, Length 40cm
22Hydrophilic guide wire, black,(0.018 - 0.038 X 80 CM - 1260CM), angled /straight tip type
23Hydrophilic guide wire, black,(,0.35, 150 cm ), angled /straight tip type
24Hydrophilic guide wire, black,(,0.35, 260 cm ), angled /straight tip type
25Baby J wire with 1.5mm J tip, super elastic nitinol alloy, M coat hydrophilic coat, one piece construction for one to one troque and radiopaque polyurethane jacket.
26Angio guide wire 0.035\" hydrophilic coated spring coil 65cm or more, double coil structure, distal 15cm is silicon coated , hybrid shaft design ACTONe on proximal shaft usable length 150cm, 180cm, 200cm, 220cm, 260cm, 300cm both angled tip & J shape.
27TERUMO type Hydrophilic guide wire,0.35x150, angled /straight tip type
28TERUMO type Hydrophilic guide wire,0.35x260, angled /straight tip type
29TERUMO type Hydrophilic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type
30150cm Hydrophilic guide wire, blue,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type
31Exchange length Hydrophilic guide wire, blue,(0.018 - 0.038 X 260 CM), angled /straight tip type
32Diagnostic guide wire single length ,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type
33PTFE coated guidewire:(0.035 X 150cm ), angled /straight tip type
34PTFE coated guidewire:(0.035 X 260cm ), angled /straight tip type
35Diagnostic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type
36PTFE coated guidewire,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type
37PTFE coated guidewire,(0.018 - 0.038 X 260 CM), angled /straight tip type
38AMPLATZ WIRE,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035”
39AMPLATZ WIRE,Lengths- 150cm, Tip - Straight/shapable, 0.035”
40AMPLATZ WIRE,super stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035”
41AMPLATZ WIRE,super stiff,Lengths- 150cm, Tip - Straight/shapable, 0.035”
42AMPLATZ WIRE,extra stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035”
43AMPLATZ WIRE,extra stiff,Lengths- 150cmcm, Tip - Straight/shapable, 0.035”
44Hydrophilic coating for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032\" - 0.038\", length 150 - 260cm, Types avaliable angled and stright. DCGI approved.
45Hydrophilic coating, PTFE coated for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032\" - 0.038\", length 150 - 260cm, Types avaliable angled and stright. DCGI approved.
460.035 diameter peripheral wire Stright tip, length 180, 260cm
47Straignt hub , FEP polymer , radio opaque , 16-20 G , puncture needle
48Puncture needle(radial) – cook model,
49Puncture needle(16G, 18G, 7cm, 20cm)
50Puncture needle(20G, 21G, 4cm)
51Micro puncture needle
52Tiger curve catheter,5F-6F / 100 cm, side hole 1, 3 curved
53PMDA / USFDA approved TIG Catheter, 100cm
54PMDA / USFDA approved TIG Catheter, comprised of a two layer construction , double braided stainlesss-steel two-polymer mesh sandwiched between layers of polyurethane ad polymide elastomers. Must have 32 strands of stainless steel braid, the shaft inner layer and outer layer contain barium sulphate. Anti kinking protector, with non-braided tip shaft (distal 2cm). 4F - 6F size and 100cm long.
55Tiger curve diagnostic catheter for brachial angiogram, size 5F-6F / 100 cm,,5f-6F / 100 cm,
56TIG4,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm,
57TIG4.5,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm,
58TR4(tiger curve) Guide catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,
59Pigtail,5F & 6F / Lengths 100, 110 & 125cm, Side holes 6 & 12
60Angled pigtail catheter,5F & 6F, Curves145& 155, Lengths 100,110 &125cm, Side holes 6 & 12
61GLIDECATH HYDROPHILIC CATHETER, 5F-6F / 100 cm,125CM
62Multipurpose(MPA1,A2,B1,B2) diagnostic catheter ,5F-6F / 100 cm,
63Amplatz Catheter Left/Right-AR/AL1,2 diagnostic catheter,5F-6F / 100 cm,
64Judkins right and left diagnostic catheter (JR/JL),4F-7F / 100 cm, 125 cm
65Mother and child catheter - size – 5F-8F/length 25cm ,5F-8F, Rapid Exchange Length 25 -cm
66Mother and child catheter Size – 6F/extension length 15cm
67NTR( no torque right) catheter,useful for engaging anteriorly angulated bypass graft(including LIMA from the left radial approch& RIMA from the femoral approach)
68Special Radial angiographic catheters, 1:1 torque control with large lumon, Coaxial alignment and soft tip, Nylon and polyurethane inner and outer layerDouble braided stainless steel Middel layer, 100 & 110cm Length
694F,5F,6F Diagnostic Right catheter 110cm - 125 cm
704F,5F,6F Guiding Right catheter 110cm- 125 cm
71Microcatheter
72Ordinary Handle gun type inflation device,-Pressure: 0-30,
73Inflation device,piston handle type intra-cam locking mechanism,Barrel volume-20ml, Pressure range: 0-30
74High pressure inflation device piston handle with finger latch mechanism,Barrel volume- 20ml, 0-30
75FDA Approved Inflation Device with 20 to 30 Atmosphere, gun type
76inflation device Maximum Pressure of 30 atm, 20ML clear syringe barrel with smooth moving plunger,self locking mechanism for easy locking as well as gradual and rapid pressure release Ergonomic handle and Precision manometer.
77Silicon valve material type Y connector,Bonded extension tube length 20cm, Push-pull type hemostatic valve
78Ordinary Y Connector,Bonded extension tube, Push-pull type hemostatic valve
79Rotating Y connector with 2 way adjustable valve,Rotating Y-connector/2-way adjustable valve
80Rotating double Y connector with 3 way adjustable valve,Rotating double Y-connector/3-way adjustable valve
81High pressure resistance Y connector ,Pressure resistance of atleast 8 atm, push pull type, inner lumen diameter-0.025”,Guidewire compatibility – 0.010” - 0.014”
82PTCA Y connector 400 Kpa leak-proof seal from proprietary designed valve,open and close by twisting,7F-9f compatible lumen allowing delivery of wide range of devices and torque and introducer fit 0.014\"-0.021\" guide wire.
83DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool.
84DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool.
852 port &3 port DCGI approved manifold. Smooth turning handles, transprarent body visual control, up to psi pressure stability for manual injectionpsi - psi, Right on/off.
863 port manifold,Right port, halfbody,with on/off handle
873 port manifold,Right port, halfbody,Righton/off handle
882.3 - 3F size Coronary microsnare,Length 150 , 175cm
893.2F size coronary snare,Length-150 cm
904,6F size coronary snare,Length- 102 cm
916-7 F size coronary snare,Length- 100 cm
925 F, 6FFlow directed temporary pacing lead with balloon,8 mm balloon, length 110cm
935F, 6F Ordinary temporary pacing lead110cmlong ,2mm bipolar electrodes
945F Ordinary temporary pacing lead,Length-105cm, 110cm, electrode spacing-15mm,25mm
955F,6F,7F, temporary pacing lead,100, 125cm, bipolar
96COVERED STENT
97Contrast media- Iohexol ,100ml (300/350mg Iodine/ml)
98Contrast media (Dimer)- Iodixanol,100ml (300/350mg Iodine/ml)
99Contrast media- Iohexol ,50-100ml(300/350mg Iodine/ml)
100Non - ionic contrast medium in sterile aqueous solution for interventional procedures. Iohexol - 350mg I / ml. Osmolalities from 2.2 - 3.
101Non - ionic, isosmolar contrast medium in sterile aqueous solution for interventional procedures. Iodixanol - 320mg I / ml. Osmolalities from 2.2 - 3.
102ETO Reel Size:- 10cm, Length :- 200m
103ETO Reel Size:- 15cm, Length :- 200m
104ETO Reel size :- 30cm, Length :- 200m
105ETO gas cartilage - Compactable to 3M Steri-Vac GS5
106ETO Chemical Indicator
107Presure injector syringe 150 ml,MEDRAD Arterion mark 7 compatible
108Angiogram Kit
109Angiography kit pack with collection pouch
110Single surgeons gown
111ECG electrode 3M
112Doc extention for PTCA guide wire.
113Inj.Nikorandil 48mg
114Inj.Tirofiban
115Inj.Heparin
116Inj.Low Molicular weight heparin
117Ventilator Mask (Large &Medium)
118Tab.Ticagrelor 90 mg
119IV Set (vented)
120PMO Line 200cm
121Lure Lock syringe 10 cm
122Drug eluting balloon.Balloon size: 1.5mm – 6 mm / Length: 10 mm -250mm
123Cutting balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm
124Scoring balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm
125135 cm Thrombus Aspiration Catheter,Outer diameter: 3.9-5.4F
126140 cm Thrombus Aspiration Catheter,Outer diameter: 3.9F
127Thrombus Aspiration Catheter with hydrophilic coating,Sizes – 6-8F, length-140cm, internal diameter – 0.070” – 0.86”
128Thrombus Aspiration Catheter with braided technology,Catheter length 145cm, maximum tip diameter - 1.73, 1.98, Guide catheter - 6, 7F
129Scoring balloon catheter:Catheter type: rapid exchange / Guidewire lumen diameter:0.014\"/Material: nylon blend/Balloon compiance: Non Compliant /Crossing profile:0.0313\"/.0.79 mm/ Coating(distal shaft and tip): hydro x hydrophilic coating / Coating (guidewire lumen): invio hydrophobic / NBP: 12 atm / RBP: 20 atm/Available Diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / Available length (in mm):10, 15, 20 / USFDA / CE approved
130Guide extention catheter 6F/7F
131Sirolimus Drug coated ballooncatheter. Size 1.5 mm- 4mm, length 10mm-40mm.

AI Tender Summary

OUR REF NO 47587229
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1 Crore
LAST DATE 19-02-2025
Authority
Authority Name Directorate Of Health Services
Work Description Tender For Cath Lab Consumables Purchase Items-- 1 Radial sheath with nitinolguide wire,4F- 6F/ length 5-7cm - wire length 45cm, wire dimension0.025 2 Radial sheath with nitinolguide wire, 6F/ length 7cm - wire length 45cm, wire dimension0.025 3 Radial Sheath with ultra thin wall technology resulting 1 fr size outer diameter reduction.5Fr, 6Fr, 7Fr with 10/16 cm length 4 Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.025, 5 Radial sheath 11 cm long,Size-4-6F, length – 11cm, guidewire-0.021, 6 Radial sheath 5& 7.5cm long,Size-4-6F, length – 5 & 7.5cm, guidewire-0.021 7 PMDA / USFDA approved 5F - 11 Fr; 7cm long, 0.035-0.038 compactable radial sheath, include surflash 20G x 2 emtry needle and 0.025 mimi plastic guide wire, ETFE sheath tubing, dilator tube should made up of polypropylene and should have silicon coating. Should contain haemostatic crosscut valve to prevent back leack of blood and aspiration of air; with intregated side arm with attached 3 way stopclock and have suture eye; kink resist; with dilator - hub lock mechanism. 8 PMDA / USFDA approved 5 - 11 Fr; 10-16-25cm long; 0.021 or 0.025 inch guide wire compactable. Sheath tube made up of ETFE, cross cut valve should be made up of silicon rubber & should have silicon coating. Have haemostaitc crosscut valve; integrated side arm with attached 3-way stopclock; with suture eye; kink resistant. dilator hub lock mechanism to prevent back out during insertion; pack mudt include with or with out metalic tube. 9 TS femoral sheath: 11 cm long Input TS femoral sheath with 0.038 inch guide wire,6f 10 TS femoral sheath: 23 cm long Input TS femoral sheath with 0.038 inch guide wire,6f 11 Femoral Sheath-Adult 0.035 inch Guide wire,4-9 F size 12 25cm long, Size femoral sheath size ranging from6f,with guide wire 13 24 cm long Femoral Sheath with 0.018-0.038 inch straight tip guide wire,3-9 F 14 25 cm long femoral sheath without guide without wire but compatible with 0.038 wire,10-14 F 15 13-80 cm long, Large Valve femoral sheath,9-18 F 16 5.5-23 cm long, Radial sheath with 0.018 inch guide wire,4-6 F 17 5-45 cm long, small Valve femoral sheath,4-8 F 18 90 cm long, Brite Tip interventional sheath ,4-11 F 19 femoral sheeth 11 cm long Size ranging from 6F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking. 20 femoral sheeth 11 cm long Size ranging from 7F, length – 11cm, guidewire-038, kink-resistant cannula design integrating a soft, flexible inner layer with a stiffer outer layer designed to increase bendability and support, and decrease kinking. 21 Cross over sheathfor peripheral intervention , 0.038 wire compactable. Size 5.5 Fr - 8Fr, Length 40cm 22 Hydrophilic guide wire, black,(0.018 - 0.038 X 80 CM - 1260CM), angled /straight tip type 23 Hydrophilic guide wire, black,(,0.35, 150 cm ), angled /straight tip type 24 Hydrophilic guide wire, black,(,0.35, 260 cm ), angled /straight tip type 25 Baby J wire with 1.5mm J tip, super elastic nitinol alloy, M coat hydrophilic coat, one piece construction for one to one troque and radiopaque polyurethane jacket. 26 Angio guide wire 0.035 hydrophilic coated spring coil 65cm or more, double coil structure, distal 15cm is silicon coated , hybrid shaft design ACTONe on proximal shaft usable length 150cm, 180cm, 200cm, 220cm, 260cm, 300cm both angled tip & J shape. 27 TERUMO type Hydrophilic guide wire,0.35x150, angled /straight tip type 28 TERUMO type Hydrophilic guide wire,0.35x260, angled /straight tip type 29 TERUMO type Hydrophilic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type 30 150cm Hydrophilic guide wire, blue,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 31 Exchange length Hydrophilic guide wire, blue,(0.018 - 0.038 X 260 CM), angled /straight tip type 32 Diagnostic guide wire single length ,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 33 PTFE coated guidewire:(0.035 X 150cm ), angled /straight tip type 34 PTFE coated guidewire:(0.035 X 260cm ), angled /straight tip type 35 Diagnostic guide wire,(0.018 - 0.038 X 260 CM), angled /straight tip type 36 PTFE coated guidewire,(0.018 - 0.038 X 80 CM - 180CM), angled /straight tip type 37 PTFE coated guidewire,(0.018 - 0.038 X 260 CM), angled /straight tip type 38 AMPLATZ WIRE,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 39 AMPLATZ WIRE,Lengths- 150cm, Tip - Straight/shapable, 0.035” 40 AMPLATZ WIRE,super stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 41 AMPLATZ WIRE,super stiff,Lengths- 150cm, Tip - Straight/shapable, 0.035” 42 AMPLATZ WIRE,extra stiff,Lengths- 260, 300cm, Tip - Straight/shapable, 0.035” 43 AMPLATZ WIRE,extra stiff,Lengths- 150cmcm, Tip - Straight/shapable, 0.035” 44 Hydrophilic coating for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032 - 0.038, length 150 - 260cm, Types avaliable angled and stright. DCGI approved. 45 Hydrophilic coating, PTFE coated for low friction endovascular steerability and trackability, radiopaque polyurethene jacket for good fluroscopic visibility and controlled navigation, prevents kinking for swift device exchange cruve : 0.032 - 0.038, length 150 - 260cm, Types avaliable angled and stright. DCGI approved. 46 0.035 diameter peripheral wire Stright tip, length 180, 260cm 47 Straignt hub , FEP polymer , radio opaque , 16-20 G , puncture needle 48 Puncture needle(radial) – cook model, 49 Puncture needle(16G, 18G, 7cm, 20cm) 50 Puncture needle(20G, 21G, 4cm) 51 Micro puncture needle 52 Tiger curve catheter,5F-6F / 100 cm, side hole 1, 3 curved 53 PMDA / USFDA approved TIG Catheter, 100cm 54 PMDA / USFDA approved TIG Catheter, comprised of a two layer construction , double braided stainlesss-steel two-polymer mesh sandwiched between layers of polyurethane ad polymide elastomers. Must have 32 strands of stainless steel braid, the shaft inner layer and outer layer contain barium sulphate. Anti kinking protector, with non-braided tip shaft (distal 2cm). 4F - 6F size and 100cm long. 55 Tiger curve diagnostic catheter for brachial angiogram, size 5F-6F / 100 cm,,5f-6F / 100 cm, 56 TIG4,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm, 57 TIG4.5,(tiger curve) diagnostic catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery,5F-6F / 100 cm, 58 TR4(tiger curve) Guide catheter, Size:5F-6F / 100 cm, soft catheter with torque controlInternationally accepted Terumo quality and equal performance needed for patient safety & to avoid spasm of radial artery, 59 Pigtail,5F & 6F / Lengths 100, 110 & 125cm, Side holes 6 & 12 60 Angled pigtail catheter,5F & 6F, Curves145& 155, Lengths 100,110 &125cm, Side holes 6 & 12 61 GLIDECATH HYDROPHILIC CATHETER, 5F-6F / 100 cm,125CM 62 Multipurpose(MPA1,A2,B1,B2) diagnostic catheter ,5F-6F / 100 cm, 63 Amplatz Catheter Left/Right-AR/AL1,2 diagnostic catheter,5F-6F / 100 cm, 64 Judkins right and left diagnostic catheter (JR/JL),4F-7F / 100 cm, 125 cm 65 Mother and child catheter - size – 5F-8F/length 25cm ,5F-8F, Rapid Exchange Length 25 -cm 66 Mother and child catheter Size – 6F/extension length 15cm 67 NTR( no torque right) catheter,useful for engaging anteriorly angulated bypass graft(including LIMA from the left radial approch& RIMA from the femoral approach) 68 Special Radial angiographic catheters, 1:1 torque control with large lumon, Coaxial alignment and soft tip, Nylon and polyurethane inner and outer layerDouble braided stainless steel Middel layer, 100 & 110cm Length 69 4F,5F,6F Diagnostic Right catheter 110cm - 125 cm 70 4F,5F,6F Guiding Right catheter 110cm- 125 cm 71 Microcatheter 72 Ordinary Handle gun type inflation device,-Pressure: 0-30, 73 Inflation device,piston handle type intra-cam locking mechanism,Barrel volume-20ml, Pressure range: 0-30 74 High pressure inflation device piston handle with finger latch mechanism,Barrel volume- 20ml, 0-30 75 FDA Approved Inflation Device with 20 to 30 Atmosphere, gun type 76 inflation device Maximum Pressure of 30 atm, 20ML clear syringe barrel with smooth moving plunger,self locking mechanism for easy locking as well as gradual and rapid pressure release Ergonomic handle and Precision manometer. 77 Silicon valve material type Y connector,Bonded extension tube length 20cm, Push-pull type hemostatic valve 78 Ordinary Y Connector,Bonded extension tube, Push-pull type hemostatic valve 79 Rotating Y connector with 2 way adjustable valve,Rotating Y-connector/2-way adjustable valve 80 Rotating double Y connector with 3 way adjustable valve,Rotating double Y-connector/3-way adjustable valve 81 High pressure resistance Y connector ,Pressure resistance of atleast 8 atm, push pull type, inner lumen diameter-0.025”,Guidewire compatibility – 0.010” - 0.014” 82 PTCA Y connector 400 Kpa leak-proof seal from proprietary designed valve,open and close by twisting,7F-9f compatible lumen allowing delivery of wide range of devices and torque and introducer fit 0.014-0.021 guide wire. 83 DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool. 84 DCGI approved PTCA Y connector , minimizing blood loss and optimizing control of interventional devices, crystal body for easy bubble detection, push click, push pull, screw type. All type with entention tubing, stop clock, torque device and insertion tool. 85 2 port &3 port DCGI approved manifold. Smooth turning handles, transprarent body visual control, up to psi pressure stability for manual injectionpsi - psi, Right on/off. 86 3 port manifold,Right port, halfbody,with on/off handle 87 3 port manifold,Right port, halfbody,Righton/off handle 88 2.3 - 3F size Coronary microsnare,Length 150 , 175cm 89 3.2F size coronary snare,Length-150 cm 90 4,6F size coronary snare,Length- 102 cm 91 6-7 F size coronary snare,Length- 100 cm 92 5 F, 6FFlow directed temporary pacing lead with balloon,8 mm balloon, length 110cm 93 5F, 6F Ordinary temporary pacing lead110cmlong ,2mm bipolar electrodes 94 5F Ordinary temporary pacing lead,Length-105cm, 110cm, electrode spacing-15mm,25mm 95 5F,6F,7F, temporary pacing lead,100, 125cm, bipolar 96 COVERED STENT 97 Contrast media- Iohexol ,100ml (300/350mg Iodine/ml) 98 Contrast media (Dimer)- Iodixanol,100ml (300/350mg Iodine/ml) 99 Contrast media- Iohexol ,50-100ml(300/350mg Iodine/ml) 100 Non - ionic contrast medium in sterile aqueous solution for interventional procedures. Iohexol - 350mg I / ml. Osmolalities from 2.2 - 3. 101 Non - ionic, isosmolar contrast medium in sterile aqueous solution for interventional procedures. Iodixanol - 320mg I / ml. Osmolalities from 2.2 - 3. 102 ETO Reel Size:- 10cm, Length :- 200m 103 ETO Reel Size:- 15cm, Length :- 200m 104 ETO Reel size :- 30cm, Length :- 200m 105 ETO gas cartilage - Compactable to 3M Steri-Vac GS5 106 ETO Chemical Indicator 107 Presure injector syringe 150 ml,MEDRAD Arterion mark 7 compatible 108 Angiogram Kit 109 Angiography kit pack with collection pouch 110 Single surgeons gown 111 ECG electrode 3M 112 Doc extention for PTCA guide wire. 113 Inj.Nikorandil 48mg 114 Inj.Tirofiban 115 Inj.Heparin 116 Inj.Low Molicular weight heparin 117 Ventilator Mask (Large &Medium) 118 Tab.Ticagrelor 90 mg 119 IV Set (vented) 120 PMO Line 200cm 121 Lure Lock syringe 10 cm 122 Drug eluting balloon.Balloon size: 1.5mm – 6 mm / Length: 10 mm -250mm 123 Cutting balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm 124 Scoring balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm 125 135 cm Thrombus Aspiration Catheter,Outer diameter: 3.9-5.4F 126 140 cm Thrombus Aspiration Catheter,Outer diameter: 3.9F 127 Thrombus Aspiration Catheter with hydrophilic coating,Sizes – 6-8F, length-140cm, internal diameter – 0.070” – 0.86” 128 Thrombus Aspiration Catheter with braided technology,Catheter length 145cm, maximum tip diameter - 1.73, 1.98, Guide catheter - 6, 7F 129 Scoring balloon catheter:Catheter type: rapid exchange / Guidewire lumen diameter:0.014/Material: nylon blend/Balloon compiance: Non Compliant /Crossing profile:0.0313/.0.79 mm/ Coating(distal shaft and tip): hydro x hydrophilic coating / Coating (guidewire lumen): invio hydrophobic / NBP: 12 atm / RBP: 20 atm/Available Diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / Available length (in mm):10, 15, 20 / USFDA / CE approved 130 Guide extention catheter 6F/7F 131 Sirolimus Drug coated ballooncatheter. Size 1.5 mm- 4mm, length 10mm-40mm.
Basic Detail
Tender No A3-823/2025
Bidding Type Tender
Location
City pathanamthitta
State Kerala
Key Dates
Publish Date 05 Feb 2025
Submission Date 19 Feb 2025
Open Date 21 Feb 2025
Finance
Tender Value 1 Crore
Tender Fee 16000
EMD 30000
Exemption Available
Document List
GENERALCONDITIONS.pdf
PRELIMINARYAGREEMENT.pdf
Tendernotice_1.pdf
b6829174-35fb-4c31-be10-498d16e3f4c8.html
BOQ_1173586.xls
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 05, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 19, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 21, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

GENERALCONDITIONS.pdf

pdf

PRELIMINARYAGREEMENT.pdf

pdf

Tendernotice_1.pdf

html

b6829174-35fb-4c31-be10-498d16e3f4c8.html

xls

BOQ_1173586.xls

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer