| 1 | Dismantling plain or corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed. |
| 2 | S&F Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 3 | S&F Pre-Painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour havimg testile strenght of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws as specified and directed. |
| 4 | Material and labour for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. |
| 5 | Hacking out old broken glass (any thickness, size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones. |
| 6 | S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n exc0.50 Sqm in each pane.(Make: Trivani/Modi Float/Gold Fish) |
| 7 | Demolition of cement concrete (unreinforced) in ground floors and paving’s not exc 15 cm thickness (below or above ground level) |
| 8 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for |
| 9 | Demolition for Brickwork or stone/ boulder masonry, built in cement/lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 10 | M&L for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in sub floor finishing cement concrete surface even and smooth using extra cement |
| 11 | M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 12 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding n. exc. 1.50 Sqm. |
| 13 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm. |
| 14 | S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying and fixing in opening as per specification and drawing. |
| 15 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frameshall be covered with heat moulded plain colour PVC \"C\" channelhaving a PVC sheet strip of 20mm width stuckinside with solventcementfor stiles and plain colour PVC sheets for top rail, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frameat siteas per specification & drawing. |
| 16 | S & F in repair vitreous china squatting pan of Orissa pattern long pan of size 580 mm x 440mm with integral foot rest white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S&F for 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipecomplete all as specified and as directed by Engineer-in-charge. |
| 18 | Taking up or down 15mm steel tubing and connections, including removal from site complete all as specified and as directed. |
| 19 | S & F 15 mm bore Galvanized Steel tubes, medium grade with all fittings forwater supply pipes fixed to walls . |
| 20 | S&F 15 mm dia bib taps, fancy type chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed. |
| 21 | S&F 15mm bore angle stop valves, fancy type chromium plated, screwed down, high pressure,screwed both ends for iron pipe or for unions & fixed. |
| 22 | S&F Vitreous China wash basin (colour white), angle back, size 550X400 mm,waste,chain and plug and porcelain stopper but including cutting for and pinning in ends of and brackets, waste pipe & CP Brass waste coupling of 32mm dia and cast copper alloy pillar tap etc. complete all as specified and directed. Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc. |
| 23 | S&F MS window guard bars, window frames etc articles confirming to Fe 410-0 or Fe 310-0. |
| 24 | S & F 100mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 25 | S & F 75mm size mild steel butt hinges medium weight cold rolled and fixed. |
| 26 | S& F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed |
| 27 | S& F Aluminium anodised barrel tower bolts 100mm long of extruded section and fixed |
| 28 | S & F 100mm size extruded aluminium alloy handles, fabricated type anodised |
| 29 | S & F 150mm size extruded aluminium alloy handles, fabricated type anodised |
| 30 | S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed |
| 31 | S & F GI steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm etc all as specified. |
| 32 | Demolition floor, hearth or tiling including cement mortar bedding (but not backing). |
| 33 | M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles . |
| 34 | M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding .38 sqm, in floor etcset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 35 | M&L hard core of gauge n.exc 63mm, deposited, spread and levelled in layers nexc 15 cm thick, watered and rammed to a true surface (bvroken stone and boulders). |
| 36 | M & L for PCC (1:4:8) type D-2 (40 mm graded stone aggregate) Cement in foundations,filling and mass concrete completed. |
| 37 | M & L for PCC (1:2:4) type B-2 (40 mm graded stone aggregate) Cement concrete in surface channels and drains with WPC 3% by weight of cementcomplete all specified and directed |
| 38 | Supply only Integrated water proofing compound |
| 39 | M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete. |
| 40 | M&L for precast cement concrete1:3:6 type C1 using 20 mm graded aggregate block solid building blocks or slabsin not exc10cmthick (with plain or interlocking joints as directed ) complete set in CM 1:4 |
| 41 | M&L rendering 15 mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement . |
| 42 | M&L for rendering 15 mm in CM (1:6) over concrete wall surfaces finished even and smooth without using extra cement. |
| 43 | M&L for 10mm thick rendering in CM 1:4 finish even and fairforlaying wall tiles. |
| 44 | M&L for Rendering 20mm thick on fair faces of brick work or concrete surface in cement plaster 1:4, with WPC 3% by weight of cementfinished even and smooth without using extra cement completed all as specified and directed. |
| 45 | M&L for re-inforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in foundation, including rafts footing, foundation beams, plinth beams, bases for columns etc complete. |
| 46 | M&L for re-inforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in columns, pillars etc complete. |
| 47 | M&L for re-inforced cement concrete 1:2:4 type B-1 (20mm graded aggregate) as in beams, plinth beams, cantilevers, bressummers, lintels over 1.5 m span etc complete. |
| 48 | M&L for Reinforcement cement concrete type B1 1:2:4 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 49 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete. |
| 50 | S&F of flatFormwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping |
| 51 | M&L for flat Formwork to faces of Baffle walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all specified and directed |
| 52 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 53 | M&L for MS TMT bars10mm dia and over, cut to lenth, bend to shape required, including cranking, bending, sprially for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. |
| 54 | M&L for MS TMT bars 08 mm dia and over, upto and including 10 mm dia in stirrups, spaces and binders. |
| 55 | Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 110 mm on after they are laid and tested complete all as specified and directed.. |
| 56 | S&F PVC Vent cowl of 110 mm dia complete all specified and directed |
| 57 | S&F PVC Vent cowl of 75 mm dia complete all specified and directed |
| 58 | S & F in rapairs rotational moulded polythene water storage tanks, multi layered 500 ltrs capacity(cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling old unserviceable one and removing out side of premises complete all as specified and as directed. |
| 59 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil |
| 60 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/loose soil for laying/taking out under ground cable and getting out the excavated soil complete all as directed. |
| 61 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in hard/dense soil. |
| 62 | Returning/filling in including spreading, levelling, watering and well remming in hard/ dense soil. |
| 63 | Removing excavated material n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point. |
| 64 | M&L forLight shade vitrified tiles 10mm thick(square/rectangular) polished, area of each tile notexceeding .36 sqm,in floors etcset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 65 | M & L for 450 x 350 x 6 to7 mm thick glazed coloured ceramic tiles on vertical surface of wallset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. |
| 66 | M&L19- 20 mm thick granite (of any type) work (table rubbed and polished) in cooking platforms/steps in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified. |
| 67 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and as directed. |
| 68 | S & F roof trusses (framed), trussed, purlines, crane grantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance piecces, cleats, plates etc confirming to Fe.290.Gde-E-165. |
| 69 | M & L for applying two coat of synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces of any description over 10 cm in width or girth not otherwise described including preparation of new steel surfaces. |
| 70 | Dismatling timer scantling over 40cm in section in any position complete all as directed |
| 71 | Dismantling of wall and ceiling boards(fibre pulp,insulation,etc)or insulation boards/slabs/blankets any thickness, including cover fillets and snap grid. |
| 72 | Supply and fix 600mmx600mmx4mm thick ‘E’ Board Classic (Make-Everest industries Ltd) as in false ceilingincluding supply and fixingGI ‘Tee” grid frame work made of special section of M.S galvanized sheet 0.30mm thick , bottom portion painted with cellular nitro painting, warping the suspending wire around theexistingwooden/steel purlin /rafterfor suspending grid frame work of size 605mmx605mm suspendedwith 4 mm dia GI wire @ 1200mm c/c on main Tee and fixed to T-grid with the help of level clip oras per manufacturer direction.The section consisting of main Tee 37mmx24mmx0.60mm, cross runner tee 37mmx24mmx0.60mm and perimeter angle of 24mmx24mmx0.50mm thick. Perimeter angle to be fixed to wall with GI screw of 40mm long @ 450 mm c/calong the perimeter of wall including applyingtwo coats of distemper oil emulsion complete all as specified and directed |
| 73 | S&F for anodised aluminium snap grid of size 605X605X mm frame work for false ceiling with aluminium anodized section size, wall angle 40mm X25mmX2mm thk, main/cross tee-section 36.5 X 25 X 1.4mm and 23.5mm X 26.4mm 1.4mm and susupended with 6mm dia GI wire respectively with and including 8mm thk laminated Gypssum board fixed to aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer\"s instructions complete all as specified and as directed by Engineer -in-charge make:(i) Aluminium section : Valco,HINDALCO, JINDAL (iI) Gypsum Board: GYPSUM IND LTD,SAINT GOBLIN |
| 74 | Material and labour for prelaminated particle board 18/19 mm thick, exterior grade prelaminatedone side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame workas in shutters for kitchen shelves/cupboards fixed in repairs. |
| 75 | M & F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 76 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 77 | S&F forPowder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters with three track(sliding type) or one fixed frame and other two track sliding as necessary , aluminium section weighing not less than 0.55 Kg/m including 5 mm glass,Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples,aluminium anodised grill of design DG 104 pattern, made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mm x 15.30mm x 1.40mm thick andnecessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws and locking system etc. complete all as specified. |
| 78 | S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete |
| 79 | S&F 30mm flush shutters, solid core construction with particle board core and plywood face panels, commercial type on both side and both face is covered with decorative face veneer with lipping/frame tp match all as completed and specified as directed. |
| 80 | S & F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc but divided into squares, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads etc |
| 81 | S&F in rep Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 82 | S&F PVC (SWR) WC connector 110mm dia lip ring. |
| 83 | M&L for newly plastered surfaces of walls and applying two coats of cement based paint,over a coat of primer complete all as specified and directed. |
| 84 | M&L for Preparing new plastered surfaces of wall and applying Two coats of acrylic distemper/ distemper oil emulsion (OBD),over a coat ofthick wall care putty all as specified including preperation of surfaces |
| 85 | M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protectionsurfacefinished even and smooth using with extra cement |
| 86 | M&L for 75 mm thick plain cement concrete type C-1, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement. |
| 87 | M & L 75 mm thick Cement concrete type D2,1:4:8 (40mm graded aggregate) as in sub base, including form work complete as as specified and directed by Engineer-in-Charge |
| 88 | M & L for 50 mm thick II nd class Hard wood clean sawn boarding with butt joints fixed with nails in any situation. |
| 89 | M & L for 2 nd class Hard wood plain fillets, square, rectangularor triangular in section,wrought, secured with nails or brads, sectional area exc 3 but n.exc 6 sq.cm. |
| 90 | Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) compete (fittings such as switches, ceiling roses, pendants, regulators, sockets etc for credit |
| 91 | Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4 SqmmPVC unsheathed copper multistranded conductor drawing into and including PVC heavy duty PVC casing caping, copper earth conductor2.5sq mm one run |
| 92 | M&L for point wiring complete as specified with 1100 V grade with 1.5 Sqmm (FRLSH) single core PVC insulated and unsheathed cable, copper conductor multistrandedpassing through including heavy duty PVC casing capping with all accessories surface type on wall/roof/floor/with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sq mm multistranded PVC insulated copper conductor cable forone light point /bell point/fan pointcontrolled by one switch |
| 93 | All as per item No 93 above but in same board withother switchesfor 5 Amp switch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable |
| 94 | All as per item No 93 above but for 5 Amp switch socket on independent board with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable |
| 95 | All as per item No 93above but size of cable 2.5 sq mmfor 15 Ampswitch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable |
| 96 | M&L fot sub main wiring with 2 run single core 4 SqmmPVC unsheathed copper multistranded conductor drawing into and including PVC heavy duty PVC casing caping, copper earth conductor2.5sq mm one run all as directed by EIC. |
| 97 | M&L fot sub main wiring with 2 run single core 6 SqmmPVC unsheathed copper multistranded conductor drawing into and including PVC heavy duty PVC casing caping, copper earth conductor4sq mm one run all as directed by EIC. |
| 98 | Supply and install commissioning of minimum 3 star ratedinverter type heating and cooling functionalhi wall split type AC of capacity 2 TR , condensing unit of copper tubing, indoor/outdoor unit complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality complete all as specified |
| 99 | Supply and fixingSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V 20 Amp |
| 100 | S&FLED Street light in new generation energy saving and environmental friendly long life LED street light made up ofpressure die castaluminium housing with high efficient LED as lightting source and lens embeddedPC cover having TOPopening seperate driver compatment with IP 66 Protection and impact resistanceon wall/ steel/ cement pole 35W, including connection from ceiling rose/ junction box to light fitting by usingthree core 1.5 sq mm cablemultistranded copper conductor pvc insulated and pvc sheathed 1100V grade complete all as specifiedincluding taking down existing unsv light fitting) |
| 101 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt (White/Warm/ white) 220V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 102 | S&F downlighter round 15W (White/Warm/ white) 220V, AC recessed mounting type with high efficiency with intrigated electronic driver, with Aluminum housing and heat sink for better thermal performance including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by EIC |
| 103 | S&F high speed wall mounted fan of 400 mm including necessary electric connection |
| 104 | S & Fix in replacement ceiling rose , 3 phase/PVC / Polycarbonate, isolated bodythree terminals |
| 105 | S&F switch piano flush type single pole one way 5 amp 240 volts all as specified and directed. |
| 106 | S & F replacement switchmodular typesingle pole one way 6 Amp with all accessories |
| 107 | S & F in replacement switchmodular typesingle pole one way 16 Amp with all accessories all as directed by EIC.Make: Legrand Cat No 6755 11 |
| 108 | S&F replacement socket outlet 3 Pin 6 Ampmodular type all accessories all as directed by EIC |
| 109 | S&F replacement socket outlet multipurpose3 Pin16 modular type with all accessories all as directed |
| 110 | Supply and fix in replacement MCB DB SPN 8 way |
| 111 | S & F in replacement MCB DB TPN 4 way |
| 112 | Supply and fixing 415V 10KA \"C\" curve miniature circuitbreaker (MCB) TPN, 100 Amps current carrying capacitycomplete with connection testing and commissioning. |
| 113 | Supply and fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SPN 32 Apmscurrent carrying capacitycomplete with connection testing and commissioning. |
| 114 | Supply and fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) SPN 5 to 32 Apmscurrent carrying capacitycomplete with connection testing and commissioning. |
| 115 | M& L for Earthing complete with galvanised steel earth plate electrode 60X60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected or indicated including testing on completion and writing earth test result on earth pit/Panelboard Incl necessary excavation, earth work, pcc pit,RCC cover ,funnel with watering pipe 20mm bore light grade,GI protection pipe 15 mm bore light grade complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. |
| 116 | M& L for Earthing complete with galvanised steel earth plate electrode 60X60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5metres below normal ground level,using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected or indicated including testing on completion and writing earth test result on earth pit/Panelboard Incl necessary excavation, earth work, pcc pit,RCC cover ,funnel with watering pipe 20mm bore light grade,GI protection pipe 15 mm bore light grade complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 20mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. |
| 117 | Supply and laying Double wall corrugated HDPE duct pipe 50mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge. |
| 118 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core |
| 119 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core |
| 120 | Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps. |
| 121 | Material and labour for bus bar chamber, outdoor type, pedestal type of size 75 cm x 60 cm x 50 cm out door dust and vermin proof front opening made out of 3.15 mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 300 Amp fixed on insulators and one MCCB FP 160 Amp, 25 KA rupturing capacity including necessary angle iron legs fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete all as directed. |
| 122 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 123 | S&F LED light fitting 1x9W/1x10W bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete as specified and directed by Engr in charge. |
| 124 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 250 mm including necessary elect connection all as specified and directed by Engr in charge. |
| 125 | Supplying and fixing 1100 volt grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire, two single core cable flat or circular multistranded 6 sqmm complete all as specified and directed |