Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47564919

Tender For Provision Of Boundary Wall (Chain Link Fencing), 02 Nos 06 Seated Toilet Cum Bath Block For Battalion Hq Of Assam Rifles Battalion At Changlang And 02 Nos Elevated Sentry Post For Tob Rangran Of Assam Rifles Battalion At Changlang (Arunachal Pr

Issued by Statutory Bodies & Commissions/Committees · changlang, Arunachal Pradesh
Tender Value
1.28 Crore
Estimated cost
Bid Submission
15 Feb 2025
0 days left
EMD
2.57 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
changlang → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision of boundary wall (Chain Link Fencing), 02 Nos 06 seated Toilet cum Bath block for Battalion HQ of Assam Rifles Battalion at Changlang and 02 Nos Elevated Sentry Post for TOB Rangran of Assam Rifles Battalion at Changlang (Arunachal Pradesh) (Arunachal Pradesh).

BOQ

Name of Work:Provision of boundary wall (Chain Link Fencing), 02 Nos 06 seated Toilet cum Bath block for Battalion HQ of Assam Rifles Battalion at Changlang and 02 Nos Elevated Sentry Post for TOB Rangran of Assam Rifles Battalion at Changlang (Arunachal Pradesh) (Arunachal Pradesh).
Sl. No. Item Description
1SCHEDULE `A\" PART-I (CHAIN LINK FENCING WITH RRM RETAINING WALL)
2Dismantling existing deteriorated barbed wire in fencing incl making rolls and stacking within 50 mtrs lead.
3Excavating holes more than 0.10 cum & upto 0.5 cum incl getting out the excavated soil in allkinds of soil for posts
4Providing & laying cement concrete1:3:6 in post fdn and thelike
5Supply & fixing of chain link fabric fence of mesh size 50 x 50 mm incl strengthening with 2 mm dia wire or nuts, bolts, and washers as reqd complete made of GI wire of dia 4 mm
6Providing GI barbed wire fencing with angle iron post at reqd distance embedded in PCC column and provided with horizontal lines and two diagonals interwoven with horizontal wires of barbed wire of weighing 9.38 kg/100m (minimum), between the two posts fitted and fixed with GI staples, turn buckles etc complete.
7Supplying at site angle iron post of required size incl bottom to be split at right angle in opposite direction for 10 cm length and drilling holes upto 10mm dia etc as reqd complete.
8Providing & fixing flat iron support for chain link for strengthening using FI 40x6mm fitted and fixed with necynuts & bolts etc complete.
9Applying one or more coats of syn enamel paint of approved brand or approved manufacturer on new steel surfaces after preparation of surfaces over one coat of red oxide primer
10RRM RETAINING WALL BELOW FENCINGEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. in all kinds of soil
11Providing and laying in positionPCC(1:4:8) in foundation.
12Providing and laying random rubble masonary with hard stone in foundation and plinth incl levelling up with cement mortar 1:6 in retaining wall.
13Providing and laying random rubble masonary with hard stone in superstructure incl levelling up with cement mortar 1:6 in retaining wall.
14Providing raised and cut pointing on stonework with cement mortar 1:3.
15Providing and laying PVC pipe 75 mm dia to length for weep holes.
16Providing and laying PCC (1:2:4) for coping
17Schedule of CreditCredit of Amount (ie minus): Old unserviceable barbed wire
18Credit of Amount (ie minus): Old unserviceable angle iron post
19SCHEDULE `A\" PART-II (02 Nos 6 seated Toilet cum Bath Block for Battalion HQ)
20(a) Bldg WorkConstruction of Toilet block with PFTs shelter of size 7.20m x 2.20mincl internal finishes all as per Drg No DGAR/ENGR/103 Sht No 1/2 & 2/2 and specifications (02 Nos blocks)
21(b) Internal electrification wkWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
22Wiring for light/ power plug with 2X4 sq. mm FRLS PVC recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
23Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
24Supplying and fixing brass batten/ angle holder including connection etc. as required
25Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required.
26Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required.
27Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required150 mm X 150 mm X 60 mm deep
28Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required using 2x4 sqmm + 1x 4 sqmm as earth wire
29Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
30Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2+6 ways
31Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
32Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
33Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
34(c)Internal water supply & sanitary fittings Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
35Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.15 mm dia nominal bore.
36Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.25 mm dia nominal bore
37Providing and fixing brass bib cock of approved quality 15 mm dia nominal bore.
38Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
39Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25 mm nominal bore
40Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
41Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.
42Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
43Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
44(d) Sewage Disposal wkConstruction of 50 users septic tank all as per Drg No MPR/ENGR/159 and specifications
45Construction of soak pit all as per Drg No MPR/ENGR/158 and specifications
46Construction of man hole chamber all as per Drg No MPR/ENGR/158 and specifications
47(e) Development works(i) Site DevelopmentEarth work inexcavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge in all kinds of soil
48(ii) RRM Retaining WallEarth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in all kinds of soil.
49Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
50Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggr 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)
51Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr 20 mm nominal size)
52Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) raised and cut pointing
53Supplying and stacking of hard stone (for stone pitching) 22.5 cm thick at site.
54M/L for 1:3:6 (1 Cement : 3 coarse sand: 6 graded stone aggregate 20 mm
55M/L for 75mm dia PVC pipe for weep holes
56(iii)Water Tank StagingStructural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
57Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
58Providing and fixing bolts including nuts and washers complete.
59Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work
60Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m in all kinds of soil
61SCHEDULE `A\" PART-III (02 Nos Elevated Sentry Post for TOB Rangran)
62(a) Bldg WkConstruction of Doiuble storey Sentry postof size 2.50m x2.50m incl internal services all as per Drg No NLR(N)/Engr/2175 Sht No 1/2 & 2/2 and specifications (02 Nos blocks)
63(b) PCC Foot pathEarth work in surface excavation not exceeding 30cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressedin all kinds of soil.
64Supplying and laying stone aggregate of 90 to 45 mm size of WBM with moroum as binding material including 13.2mm size stone screening sorting, watering spreading to template, compacting stone aggregate in uniformed thickness and consolodiation with power road roller of 8 to 10 tonne capacity in two layer with proper gradient and camber etc complete(150mm thick )
65Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all work upto plinth level.
66Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

AI Tender Summary

OUR REF NO 47564919
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.28 Crore
LAST DATE 15-02-2025
Authority
Authority Name Assam Rifles
Work Description Provision of boundary wall (Chain Link Fencing), 02 Nos 06 seated Toilet cum Bath block for Battalion HQ of Assam Rifles Battalion at Changlang and 02 Nos Elevated Sentry Post for TOB Rangran of Assam Rifles Battalion at Changlang (Arunachal Pradesh) (Arunachal Pradesh).
Basic Detail
Tender No VIII.11014/8667
Bidding Type Tender
Location
City changlang
State Arunachal Pradesh
Key Dates
Publish Date 04 Feb 2025
Submission Date 15 Feb 2025
Open Date 17 Feb 2025
Finance
Tender Value 1.28 Crore
Tender Fee 1500
EMD 2.57 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
b181f28d-0cb9-43c9-967e-24dd05dae148.html
BOQ_890975.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 04, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 15, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 17, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

b181f28d-0cb9-43c9-967e-24dd05dae148.html

xls

BOQ_890975.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender