}

Tender For Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Specification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To, mumbai-Maharashtra

Central Railway has published Tender For Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Specification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To. Submission Date for this Tender is 18-02-2025. Medical Equipment Tenders in mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

47564818
Tender For Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Specification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To
Tender
Indian
Maharashtra
Mumbai
18-02-2025

Tender Details

Supply Of Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Specification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To -700 Mmhg With Adjustable Pressure Settings, . Flow Rate: Ranges Between 15 To 30 Liters Per Minute (L/Min) . 2. Collection Canisters: Material: Transparent Polycarbonate Or Autoclavable Plastic. Volume Capacity: 2 Liters Per Can. Overflow Protection: Built-In Overflow Shutoff Valves To Prevent Fluid From Entering The Pump. Lid And Sealing Mechanism: Airtight Seals On The Canister Lids To Prevent Leaks And Maintain Suction. 3. Tubing: Material: Medical-Grade Pvc Or Silicone, Clear And Flexible For Visibility And Easy Handling. Length: 1 To 2 Meters . Tubing Diameter: 7 Mm To 10 Mm (Inner Diameter) To Maintain Optimal Fluid Flow. 4. Filtration: Bacterial Filter: High-Efficiency Bacterial Filter Filter Placement: Located Between The Suction Tubing And The Pump For Optimal Protection. 5. Controls: Pressure Adjustment Dial: Allows For Precise Control Over Suction Power. On/Off Switch: To Show Power Status. 6. Portability: Size And Weight: Around 5 To 10 Kg. Mobility Features: Should Equipped With Wheels Or Handle 7. Power Source: Electrical: Standard Models Operate On 110-240V Ac For Worldwide Compatibility. 8. Noise Level: < 45 Db 9. Sterilization: Autoclavable Components: Collection Canisters, Tubing, And Filter Elements Should Be Sterilizable To Ensure Hygiene. 10. Additional Features: Overflow Protection System: Prevents Damage To The Machine If The Canister Overflows. Vacuum Gauge: Allows For Real-Time Monitoring Of Suction Pressure. Emergency Vent: Quick-Release Vent For Immediate Pressure Release If Needed.Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Specification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To -700 Mmhg With Adjustable Pressure Settings, . Flow Rate: Ranges Between 15 To 30 Liters Per Minute (L/Min) . 2. Collection Canisters: Material: Transparent Polycarbonate Or Autoclavable Plastic. Volume Capacity: 2 Liters Per Can. Overflow Protection: Built-In Overflow Shutoff Valves To Prevent Fluid From Entering The Pump. Lid And Sealing Mechanism: Airtight Seals On The Canister Lids To Prevent Leaks And Maintain Suction. 3. Tubing: Material: Medical-Grade Pvc Or Silicone, Clear And Flexible For Visibility And Easy Handling. Length: 1 To 2 Meters . Tubing Diameter: 7 Mm To 10 Mm (Inner Diameter) To Maintain Optimal Fluid Flow. 4. Filtration: Bacterial Filter: High-Efficiency Bacterial Filter Filter Placement: Located Between The Suction Tubing And The Pump For Optimal Protection. 5. Controls: Pressure Adjustment Dial: Allows For Precise Control Over Suction Power. On/Off Switch: To Show Power Status. 6. Portability: Size And Weight: Around 5 To 10 Kg. Mobility Features: Should Equipped With Wheels Or Handle 7. Power Source: Electrical: Standard Models Operate On 110-240V Ac For Worldwide Compatibility. 8. Noise Level: < 45 Db 9. Sterilization: Autoclavable Components: Collection Canisters, Tubing, And Filter Elements Should Be Sterilizable To Ensure Hygiene. 10. Additional Features: Overflow Protection System: Prevents Damage To The Machine If The Canister Overflows. Vacuum Gauge: Allows For Real-Time Monitoring Of Suction Pressure. Emergency Vent: Quick-Release Vent For Immediate Pressure Release If Needed.,Suction Machine For Ent- Power Voltage Ac220v, Max Negative Pressure Spe Cification: Suction Machine Specifications: 1.Motor And Suction Power: Motor Type: High-Performance Piston Or Diaphragm Motor, . Suction Power: More Than -550 Mmhg To -700 Mmhg With Adjustable P Ressure Settings, . Flow Rate: Ranges Between 15 To 30 Liters Per Minute (L/Min) . 2. Collection Caniste Rs: Material: Transparent Polycarbonate Or Autoclavable Plastic. Volume Capacity: 2 Liters Per Can. Ove Rflow Protection: Built-In Overflow Shutoff Valves To Prevent Fluid From Entering The Pump. Lid And Seali Ng Mechanism: Airtight Seals On The Canister Lids To Prevent Leaks And Maintain Suction. 3. Tubing: Mat Erial: Medical-Grade Pvc Or Silicone, Clear And Flexible For Visibility And Easy Handling. Length: 1 To 2 M Eters . Tubing Diameter: 7 Mm To 10 Mm (Inner Diameter) To Maintain Optimal Fluid Flow. 4. Filtration: Bacterial Filter: High-Efficiency Bacterial Filter Filter Placement: Located Between The Suction Tubing An D The Pump For Optimal Protection. 5. Controls: Pressure Adjustment Dial: Allows For Precise Control Ov Er Suction Power. On/Off Switch: To Show Power Status. 6. Portability: Size And Weight: Around 5 To 10 Kg. Mobility Features: Should Equipped With Wheels Or Handle 7. Power Source: Electrical: Standard Models Operate On 110-240V Ac For Worldwide Compatibility. 8. Noise Level: => Limited

Key Value

Document Fees
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail