| 1 | Taking down defective water cooler 40/80/120/150 LITRE capacity, transportation from MES Store Yard/Site to workshop and back including re-fixing /reinstalling,painting, testing, connecting the same, including replacement of defective parts/burnt out compressor selected unit with new compressor from authorised dealer & including flushing of condenser and charging with required quantity of appropriate refrigerant gas, complete all as specified and as directed.Notes -Change of spare parts shall be measured separately under relevant item here-in-after if required as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit. |
| 2 | Material and labour for replacement as in repair of 80-100 mfd Starting capacitor for water cooler upto capacity 150 ltrs. Make : Sarda/ Power or equivalent. |
| 3 | Material and labour for replacement as in repair of running capacitor 10 mfd for Water Cooler upto capacity 150 ltrs. Make : Sarada/Power or equivalent. |
| 4 | Material and labour for replacement as in repair of 15mm bore chromium plated push type bib tap suitable for water cooler ofany capacity as per existing shape and make or equivalent. |
| 5 | Material and labour for replacement as in repair of Thermostat switch for water cooler. Make : Indfoss or equivalent |
| 6 | Material and labour for replacement as in repair of Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule of size 15 mm complete all as specified and directed. |
| 7 | Supply only sealed compressor unit existing type obtained from authorised dealer ofWater Cooler upto 150 ltrs capacity for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed. |
| 8 | Material and labour in repair of Door gasket for Water Cooler upto 150 ltrs capacity. |
| 9 | Material and labour for replacement as in repair of Starting Relay suitable for water cooler upto 150 ltrs capacity |
| 10 | Material and labour for replacement as in repair of Overload protector suitable for Water Cooler of capacity 150 ltrs |
| 11 | Taking down defective refrigerator upto 320 L capacity including tre-fixing/reinstalling, testing, connecting the same, including replacement of defective parts/burnt compressor selected unit with new compressor/ condensor coil/ cooling coil obtained from authorised dealer & including flushing of condenser and charging with required quantity of appropriate refrigerant gas, complete all as specified and as directed.Notes:-Change of spare parts shall be measured separately under relevant item here-in-after if required as supply only rates fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit. |
| 12 | S&F as in repair of Starting relay open / box type for Refrigerators of capacity upto 315 ltrsincluding taking down unserviceable one complete all as specified and directed . |
| 13 | S&F as in repair of Timer / bimetalic relay of existing type for Refrigerators of capacity upto 315 ltrs |
| 14 | S&F as in repair of Thermostat switch (Make : Indfoss/Kelvinator) for Refrigerators of capacity upto 315 ltrs including taking down unserviceable one complete all as specified and directed. |
| 15 | Supply only cooling coil unit for domestic refrigerator of capacity upto 315 Ltr, for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed. |
| 16 | Supply only sealed compressor unit existing type obtained from authorised dealer of Refrigerators upto 315 ltrs capacity for fixing against defective parts of refrigerator taking down under respective item complete all as specified and as directed. |
| 17 | Material and labour for servicing of Window / Split AC of capacity 1.5/ 2.0 TR by disconecting electric connection, opening the unit, dismantling the cover of Condensor and cooling coil, thoroughly cleaning the external surface (both side) of condensor coil, cooling coil and all other key component, fins, base by discaling chemicals, water etc with the help of air blower and wire brushing, cleaning of Air filter, fan blades, drain pipes, testing leakage and reassemble all the components filter, plate, runner, fan blade etc in original position complete all as specified and as directed. |
| 18 | Taking down/up defective Window AC of 1.5 TR capacity, transportation from MES Store Yard/Site to workshop and back including re-fixing /re-installing after replacement of defective/burnt rotary type compressor sealed unit / flushing of condenser / replacement of condensor or cooling coil and charging with required quantity of appropriate refrigerant gas, re-connection of electric connections andtesting complete in all respect complete all as specified and as directed. |
| 19 | All as per Item No. 18 above but AC Split Type of 1.5 / 2.0 TR Capacity, complete all as specified and as directed.Notes :- (i) Change of spare parts shall be measured separately under relevant item here-in-after as supply only rates. Fixing charges for spare parts shall deemed to be inclusive in the quoted rates. Old replaced material has to be shown to Engr-in-Charge measured under sch of credit.(ii) Refreigerant gas shall be measured and paid separately under relevant items as required to fill as per requirement/manufacturer instruction excluding measurement of gas filled by OEM). |
| 20 | Supply only new compressor sealed unit matching with existing type/model in the unit properly from authorised dealer for 1.5 TR window type AC, ISI markedfor fixing against defective parts of AC taking down under respective item complete all as specified and as directed. |
| 21 | Supply only suitable capacity/ model condensing coil unit copper for window type AC 1.5 Ton capacity ISI marked for fixing against defective parts of AC taking down under respective item complete all as specified and as directed. |
| 22 | Supply only condensing coil unit copper for split type AC 1.5/2.0 TR capacity for fixing against defective parts of AC taking down under respective item complete all as specified and as directed. |
| 23 | Supply only new compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR split type AC, ISI marked for fixing against defective parts of AC taking down under respective item complete all as specified and as directed. |
| 24 | S&F air circular blower fan motor of AC (Split Type) 1.5/2 TR Capacity (as per sample/site Requirement) including taking out unserviceable air circular blower fan motor from AC, complete all as specified and as directed. |
| 25 | Supply and fixing as in repair of AC single phase 230 Volts contactor assembly for 1.5/ 2.0 TR capacity split AC condensing unit of carrier/Voltas/LG/Amtex complete all as specified and as directed. |
| 26 | Material and labour for repair of AC single phase 230 volt Printed Circuit Board for 1.5/ 2.0 TR capacity split type AC cooling unit of carrier/Voltas/LG/Amtex complete all as specified and as directed. |
| 27 | M&L for replacement of AC single phase 230 volts remote (Hand set) for 1.5/ 2.0 TR capacity split type AC of carrier/Voltas/LG/Amtex complete all as specified and as directed by the Engr-in-Charge. |
| 28 | Material and labour for replacmentas in repair of 36 -45 mfd running capacitor of any capacity. Make: Sarda/ Power or equivalent. |
| 29 | Material and labour for replacement as in repairof 80-120 mfd Starting capacitor of any capacity. Make : Sarda/ Power or equivalent. |
| 30 | Material and labour for replacement as in repair of Thermostat switch for 1.5 TR capacity Window Type AC complete all as specified and as directed. Make: Indfoss or equivalent. |
| 31 | Material and labour in repair of Fan Blade for 1.5 TR capacity Window type AC/Split AC |
| 32 | Material and labour for replacement as in repair of Over load protector for Window/ Split Type AC of capacity 2/1.5 TR complete all as specified and as directed. |
| 33 | Material and labour for replacement as in repair of Front cabinet for 1.5 TR Window Type AC complete all as specified and as directed. |
| 34 | Material and labour for replacement as in repair of Basetray for Window Type AC of 1.5 TR capacity complete all as specified and as directed. |
| 35 | Material and labour for replacement as in repair of Air filter for 1.5 TR/ 2.0 TR Split Type AC complete all as specified and as directed. |
| 36 | Material and labour for replacement as in repair of LCD/ LED display unit ISI marked for 1.5 TR / 2.0 TR capacity Split TypeAC complete all as specified and as directed. |
| 37 | Supply and laying out of copper pipe (hard) 5/8\" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge. |
| 38 | Supply and lay out of copper pipe (hard) 1/2\" dia with PUF insulation CFC free etc as required at site complete all as specified and as directed by the Engr-in-Charge. |
| 39 | Cleaning the cooling coil and condensor with the help of compressed Nitrogen inner side of the copper tube for flushing out all sludge and oil deposited in the copper tube and materials and labour forcharging of refrigerant R-22 as required including replacement of strainerand finding out the leakage, brushing the same, testing for following capacity of AC complete all as specified and as directed by the Engr-in-Charge:- (a)Split/Window type Air conditioner 1.5/ 2.0 TR capacity |
| 40 | Material and Labour for disconnecting defective indoor unit of split AC capacity 1.5/ 2 TR and replacing the same with new indoor unit in position fixing in original position as per existing complete all as specified and as directed. |
| 41 | Material and labour for charging of Refrigerant R-22/ R134 A/ R404 in Split/ Window AC, Water Cooler and Refrigerator complete all as specified and as directed. |
| 42 | S&F for mild steel stand as per existing for AC Window type/Split type 1.5 to 2.0 TR capacity, grouting with brick wall with mild steel expandable bolts with steel rawl plug including making good walls in cement mortar (1:3) as required including dismantling old unserviceable mild steel stand for AC’scomplete all as specified and as directed. |
| 43 | Repair / maintenance and overhauling to servo voltage stabilizer of capacity 1 KVA to 5 KVA from position, open the outer covers, overhauling the complete unit by cleaning with suitable cleaning materials and replacement of minor spares such as fuse, diodea, carbon brushes & holders, internal electric wiring and electronic accessories and insulate properly by varnshing, greasing, CRC spraying complete all as specified and directed. Note: Spares such ac voltmeter, ammeter, MCB, toggle switch, PCB board and relays measured and paid separately under respective items and labour cost deemed to include in quoted rates for replacement of spares. Old replacedmaterial has to be shown to Engr-in-Charge measured under sch of credit. |
| 44 | Supply only over load /under load / volt relay, for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed. |
| 45 | Supply only PCB control for 1 KVA to 5 KVA (single phase), for fixing against defective parts of voltage stabilizer taking down under respective item complete all as specified and as directed. |