| 1 | Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniformand free from streaks and holes etc., complete as per MoRT&H specification No.803 |
| 2 | Providing and fixing reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate / methyl methercrylate/ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280. The reflective raised pavement markers shall also confirm to theMORTH circular No RW / NH. 33023/10/ 97-DO.III dt 11.06.97. The height, width and length shall not be less than 15 mm, 90 mm and 100 mm and with minimum reflective area of 13 Sq.cm on each side and the slope to the base shall be 35 +/- 5 degree. Each reflector shall have a CIL not less than values specified in Table 2 of said MORTH circular. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kgf. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer’s recommendationand complete as directed by the engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35 - 2015 guidelines and MoRT&H specification 804 etc., complete |
| 3 | Providing and Fixing of Flexible Median Marker that are made of tough, high impact resistant, injection molded, thermoplastic body with property of flexibility to provide high durability. The dimension of Flexible Median Marker should not exceed 18.4 cm in height(including shank height),12.5 Cm in width. ,0.65 cm in thickness and shank depth shall be 3.4 cm The body structure shall be rounded at all its corners and edges. The plastic used for molding the Flexible Median Marker should survive impact load of 5kg continuously for 750 times at room temperature. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The Median Marker shall have flame like shaped body with, fluorescent yellow color retro reflective sheeting of size not less than 90 Cm square, with fully reflective micro prismatic cube corners as its retro-reflective elements as per IRC 67 2012 and ASTM D4956-09 type XI specifications electivity values. The retro-reflective sheeting shall be one or both sides of the Flexible Median Marker and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage, etc., The Flexible Median Marker shall be fixed by a combination of epoxy adhesive and grouting as recommended by manufacturer. |
| 4 | Supplying and installation of delineators (road way indicators, hazard markers and object markers), 80-100 cm high above ground level, painted at alternatively black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm diacirculareflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 etc., complete (as per MoRT&H specification No. 806) |
| 5 | Providing and Erecting of Retro - Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of operly designed foundation with M15 grade cement concrete 5cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflectivesheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MoRT&H Specification No.801) 30cm x 90cm rectangular |
| 6 | ProvidinganderectingofRetro-Reflector›sedCautionary,MandatoryandInformatorysigns {withoutdefinitionboard}madeoutofHighIntensityPrismaticGradeSheetingconfirming toType-IVstandardsofIRC-67:2012andASTMD4956—09,specificationandfixedover 2mmthickAluminiumsheetfixedoverabacksupportingframeof25mmx25mmx3mmMild Steelangleandsupportedonamildsteelanglepost75X75X6mmwithaclearheightofnot lessthan2. 10mfromthegroundleveltothebottomofthesignboardand0.6Ombelow groundlevel.ThesignpostshouldbepaintedasperIRC 67-2012andfirmlyfixedtothe groundbymeansof properlydesignedfoundationwithM15gradecementconcrete 45cmX45cmX60cmsizeincludingcostandconveyanceofallmaterials,equipment, Machinery andlabourwith all leads and lifts, loadingchargesnecessary forsatisfactory completionofthe workasdirectedbythe engineerin Charge. HighintensityRetro-Reflectro sheet shallconsist ofminimum coefficient ofRetro-reflectionas perTable6.6 ofIRC 67- 2012.Theretro-reflectivesheetingshallbecoveredunder7 yearwarrantyissuedforfield performanceandacertifiedcopyofthreeyearsoutdoorexposurereportshallbeobtainedas per IRC67:2012.(as per MORT&HSpecificationNo.801)- 90 cm high octagon |
| 7 | Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 –09,specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012 . ( as per MoRT&H Specification No.801) 90cm Equilateral Triangle. |
| 8 | Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum efficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012 . ( as per MoRT&H Specification No.801) 60cm circular |
| 9 | Providing and erecting of Retro - Reflectorised Cautionary, Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 –09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mm x 25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge. High intensity Retro - Reflectro sheet shall consist of minimum efficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012 . ( as per MoRT&H Specification No.801) 60cm x 45cm Rectangular board |
| 10 | ProvidinganderectingofRetro-Reflector›sedCautionary,MandatoryandInformatorysigns {withoutdefinitionboard}madeoutofHighIntensityPrismaticGradeSheetingconfirming toType-IVstandardsofIRC-67:2012andASTMD4956—09,specificationandfixedover 2mmthickAluminiumsheetfixedoverabacksupportingframeof25mmx25mmx3mmMild Steelangleandsupportedonamildsteelanglepost75X75X6mmwithaclearheightofnot lessthan2. 10mfromthegroundleveltothebottomofthesignboardand0.6Ombelow groundlevel.ThesignpostshouldbepaintedasperIRC 67-2012andfirmlyfixedtothe groundbymeansof properlydesignedfoundationwithM15gradecementconcrete 45cmX45cmX60cmsizeincludingcostandconveyanceofallmaterials,equipment, Machinery andlabourwith all leads and lifts, loadingchargesnecessary forsatisfactory completionofthe workasdirectedbythe engineerin Charge. HighintensityRetro-Reflectro sheet shallconsist ofminimum coefficient ofRetro-reflectionas perTable6.6 ofIRC 67- 2012.Theretro-reflectivesheetingshallbecoveredunder7 3 earwarrantyissuedforfield performanceandacertifiedcopyofthreeyearsoutdoorexposurereportshallbeobtainedas per IRC67:2012.(as per MORT&HSpecificationNo.801)- 60 x 60 cm Square board |
| 11 | ProvidinganderectingofRetro-Reflector›sedCautionary,MandatoryandInformatorysigns {withoutdefinitionboard}madeoutofHighIntensityPrismaticGradeSheetingconfirming toType-IVstandardsofIRC-67:2012andASTMD4956—09,specificationandfixedover 2mmthickAluminiumsheetfixedoverabacksupportingframeof25mmx25mmx3mmMild Steelangleandsupportedonamildsteelanglepost75X75X6mmwithaclearheightofnot lessthan2. 10mfromthegroundleveltothebottomofthesignboardand0.6Ombelow groundlevel.ThesignpostshouldbepaintedasperIRC 67-2012andfirmlyfixedtothe groundbymeansof properlydesignedfoundationwithM15gradecementconcrete 45cmX45cmX60cmsizeincludingcostandconveyanceofallmaterials,equipment, Machinery andlabourwith all leads and lifts, loadingchargesnecessary forsatisfactory completionofthe workasdirectedbythe engineerin Charge. HighintensityRetro-Reflectro sheet shallconsist ofminimum coefficient ofRetro-reflectionas perTable6.6 ofIRC 67- 2012.Theretro-reflectivesheetingshallbecoveredunder7 3 earwarrantyissuedforfield performanceandacertifiedcopyofthreeyearsoutdoorexposurereportshallbeobtainedas per IRC67:2012.(as per MORT&HSpecificationNo.801)- 80 x 60 cm rectangular board |
| 12 | ProvidinganderectingofDirectionand PlaceIdentification Retro-reflectorised Sign madeout of High IntensityPrismaticGradeSheetingconfirmingto Type-IVstandardsof IRC-67:2012 andASTMD4956—09, specificationandfixedover2mmthickAluminiumsheetfixedovera backsupportingframeof 25mmx25mmx3mmMildSteel angleandsupportedon amildsteel anglepost75X75X6mmwithaclearheightofnotlessthan2.10mfromthegroundlevelto thebottomofthesignboardand0.6Ombelowgroundlevel.Thesignpostshouldbe painted asper IRC67-2012andfirmlyfixedtothegroundbymeansofproperlydesignedfoundation withM15gradecementconcrete45cmX45cmX60cmsizeincludingcostandconveyanceof all materials, equipment, Machinery and labour with all leadsand lifts, loading charges necessaryforsatisfactorycompletionofthe workasdirectedbytheengineerin charge. High intensityRetroReflectrosheetshallconsistofminimumcoefficientofRetro-reflection asper Table 6.6 of IRC 67-2012. The retro- reflective sheeting shall be covered under 7 year warrantyissuedforfieldperformanceand acertifiedcopyofthreeyearsoutdoorexposure reportshall be obtainedasper IRC67:2012.(as per MORT&HSpecificationNo.801) (for sign having area more then 0.9 sqm) Type-IV |
| 13 | Providing and fixing of Digitally Printed Retro Reflectorized Overhead Cantilever Informatory sign Board of Size 5.00m x 1.80m made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50mm x 50mm x 6mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 12mm thick with a ground clearance of 6 meters along with 80NB (Nominal Bore) MS Pipe with 4mm thick and 40NB (Nominal Bore) MS Pipe with 3.20mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes 420x420, 682x420, 288x288, 288x927 & 44x130 are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures. The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012.The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No.801).Cantilever sign shall be installed at the site as per the approved structural and foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, machineries to worksite, including all labour charges for fixing the gantry in position with all leads and lifts, loading charges and necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete |
| 14 | Providing and fixing of Digitally Printed Retro Reflectorized Overhead Gantry Informatory sign board made of cube corner Micro Prismatic grade sheeting conforming to Type XI standards of IRC67 - 2012 and ASTMD4956 – 09, specification and fixed over 2 mm thick aluminum sheet fixed on back supporting frame mild steel L angle of size 50 mm x 50 mm x 6 mm. The Vertical support post for the installation of overhead sign Gantry shall be made of 300NB (Nominal Bore) MS Pipe with 8 mm thick with a ground clearance of 6 meters along with 80 NB (Nominal Bore) MS Pipe with 4 mm thick and 40 NB (Nominal Bore) MS Pipe with 3.2 mm thick support posts. MS Base plate of size 1200mm x 1200mm x 25mm and MS Top plate of size 900mm x 1650mm x 16mm to be used to hold the sign board at the top and bottom respectively. MS Stiffener plates 8mm thick of sizes(420x420), (682x420), (288x288), (288x927), (44x130)are to be used. Anchor bolts of dimension 25mm dia and 1000mm length are to be used as fixtures.The approved direction information should be digitally printed and should have 70% of the co-efficient of Retro-reflection values against the values as mentioned in Table 6.9 of IRC67 – 2012.The Latex printer used for digital printing should use inks with low VOC emissions and have green guard, eco logo certificates as per UL 2801 standards. The retro-reflective sheeting shall be covered under 10 years warranty issued for field performance and a certified copy of three years Outdoor exposure report shall be obtained as per IRC 67-2012 (As per MoRT&H specification No. 801).Cantilever sign to be erected at the site as per the foundation drawing provided in the tender document and including cost and conveyance of all materials, equipment, Machinery and labor with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer-in-charge etc., complete of Size – 12 m x 1.8 m |
| 15 | Calculation of SubTotal, GST and Total Amount carried out by system automatically |
| 16 | Basic cost of value put to tender as per estimate |
| 17 | Add GST at 18% |
| 18 | Total Value put to Tender |
| 19 | Difference in Value |
| 20 | Bidder quoted value |
| 21 | Add GST at 18% of Final quoted Value |
| 22 | Total Value of Contract Including 18% of GST |
| 23 | Basic cost of value put to tender as per Estimate |
| 24 | Quoted Rate in Figures (Total Value of Contract Including 18% of GST ) |