| 1 | (A)CIVIL WORK |
| 2 | Earth work in excavation by mechanical means {Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. . |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources :8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cement content of 330 kg /cum All works upto plinth level Footing |
| 5 | Same as item above but All works above plinth & up to floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 6 | Slab |
| 7 | Beam |
| 8 | Column |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Centring and shuttering including strutting, propping etc. and removal of form for: |
| 11 | Foundations, footings, bases of columns, etc. for mass concrete. As per. |
| 12 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. As per. |
| 13 | Columns, Pillars, Piers, Abutments, Posts and Struts as per. |
| 14 | Suspended floors, roofs, landings, balconies and access platform. As per. |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 16 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6coarse sand) :With F.P.S.(non modular) brick. |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 19 | 5.0 mm thick (weight not less than 12.50 kg persqm) instead of 4 mm thick (weight not less than 10 kg per sqm). |
| 20 | Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood |
| 21 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 22 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 23 | Providing and fixing ISi marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm |
| 24 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 25 | Providing and fixing ISi marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) 300x16 mm |
| 26 | Providing and fixing ISi marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) 250x10 mm |
| 27 | CEMENT PLASTER (IN COARSE SAND): 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 28 | Add for plaster drip course/ groove inmoulding to R.C.C. projections. |
| 29 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size: Size of Tile 600 x 1200 mm |
| 30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 31 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 32 | Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. |
| 33 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : : Two or more coats on new work (Ist quality Royal, Silk, Asian/Berge) as per |
| 34 | Finishing walls with Acrylic Smooth exterior paint of required shade : : Two or more coats on new work (Ist quality Royal, Silk, Asian/Berge) as per |
| 35 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 36 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture. |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 38 | Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement sluny, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 39 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer in-Charge. |
| 40 | (B)PLUMBING WORK |
| 41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm Nominal outer dia pipe. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 25 mm Nominal outer dia pipe. |
| 43 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm dia. |
| 44 | S/f of premium type wash hand basin 500x400 mm size of white glazed earthen ware (22\"x16\") C.P. West coupling and one pair M.S. Bracket and labour charge etc. |
| 45 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 46 | Providing and fixing unplasticised PVC pipe clips of approved design PvC rain pipes with intel/ outlet bend etc. compete 110 mm dia. |
| 47 | Providing and placing on terrace poly thylene water storage tank of approved brand and manufactured with cover and locking arrangement necessary hooks of inlet etc. complete for tank capacity 100 Ltr. |
| 48 | Providing and Fixing Long body Bip cock. |
| 49 | (C)ELECTRICAL WORK |
| 50 | Wiring point forLight with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq.mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 51 | Wiring point for Fan/light duty exhaust fan with 1.5sq. mm. FR PVC insulated multistrand single core copper cable in PVC conduit with 1.5 sq. mm. FR PVC-insulated multistrand Copper conductor cable as earth wire drawn in side the conduit. Add for light/fans with moduler type switch. |
| 52 | Wiring point for plug with 1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in PVC conduit pipe Partly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductorcable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. |
| 53 | Wiring point for Exhaust fan with1.5 sq.mmFRLSH PVC insulated multistrand single core copper conductorcable in heavy gauge PVC conduit pipePartly concealed in the wall and partly Laid in slabalong with the reinforcement before concreting complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and 15 amp piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc.complete in all respect,as directed, including matching colour wash. |
| 54 | Supply & wiring of submains with 2 nos.2.5 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge PVC conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. |
| 55 | Supply & wiring of submains with 2 nos.4 sq.mmFRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage PVC conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. |
| 56 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA |
| 57 | Supply & Fixing of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaustfan (Heavy Duty) withblades,cover etc. complete as required |
| 58 | Supply and fixing of 240 volts C Curve6-32 amp SPminiature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A |
| 59 | Supply and fixing of flush/surface mounting 4 ways SPN distribution boards (Legrand Lexic) without MCB with additional metal doorcomplete in all respects. As directed by engineer incharge. CAT A |
| 60 | Supply & Fixing of MCB blanking plate for DB. |
| 61 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finshing propely complete in all respect. |
| 62 | Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. |
| 63 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 64 | Supply & Fixing of Moduler switch blanking plate for Moduler switch board. |
| 65 | Supply and fixing One/Two module G.I box awlong with moduler base with cover plate. |
| 66 | 1 or 2 Module (75mmX75mm) |
| 67 | 3 Module (100mmX75mm) |
| 68 | 4 Module (125mmX75mm) |
| 69 | 6 Module (200mmX75mm) |
| 70 | 12 Module (200mmX150mm) |
| 71 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 72 | Supplyfixingofelectronic fan regulator 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 73 | GST EXTRA AS PER APPLICABLE |