| 1 | Installation of water cooler, water purifier and construction of water booth along with required pipe line work and electrification at (1) NUPS,DBS Patrapali (2) NUPS, Makri (3) NUPS,PUPs Jamkhunta (4) Upper primary school, Pendramal (5) Govt. Upper Primary school, Gandapatrapali near villages of O.F.Badmal under CSR. |
| 2 | Excavating in post holes in soft /loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm. |
| 3 | Excavating in trenches,(Soft/Loose soil) n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. exc 10 sq m on plan and n exc 1.5 m in depth and getting out. |
| 4 | Surface excavation in soft/ loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out. |
| 5 | Material and labour, for Sand filling under floors or in foundations including watering and consolidation. |
| 6 | Soft/loose earth filling , including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 7 | Material and labour, for Cement concrete (Type-B2,1:2:4, 40mm graded aggregate) in foundations, filling and mass concrete. |
| 8 | Cutting channels, grooves or rebates exc 15cm & ne xc 30cm girth and triming in concrete surfaces. |
| 9 | Material & labour for, Cement concrete type B2,1:2:4(40mm graded aggregate) in surface channels and drains |
| 10 | Material & labour for providing cement concrete type B1, 1:2:4(20mm graded aggegate) in water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directedincluding for use of formwork (straight or curved). |
| 11 | Cutting 15cm deep holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required. (Cutting n.exc. 150 sq.cm ) |
| 12 | Material and labour,for old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in 1:6 cement mortar. |
| 13 | M&L,for Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of walls,sun shades, etc. cutting not exc 10 cm girth. |
| 14 | M&L, for mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165. |
| 15 | Supplying only chain link MS galvanisd fencing, any size or type. |
| 16 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire. |
| 17 | M&L,for mild steel work in tubular structure including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication. |
| 18 | M&L for, Mild steel bars 8mm, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 19 | M&L,for 145mm thick cement concrete flooring type B- 1, 1:2:4 (20mm graded aggregate) including use and waste of form work/screed strips and to divide the area in panels,finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc. even and rough to receive the topping layer. |
| 20 | M&L,for Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 21 | Taking down cement plaster on brick walls, including raking out joints, hacking for key, scrubbing down with water, etc. and M&L,for rendering 15mm thick cement plaster on fair faces of brick work surfacesin 1:4 cement mortar. |
| 22 | M&L, for rendering 15mm thick cement plaster on fair faces of brick work or concrete surfacesof 1:4 cement mortar with the additional thickness is to be provided as floating/setting coat. |
| 23 | Rendering 10mm thick cement plaster on fair faces of concrete surfaces of 1:4 cement mortar. |
| 24 | M&L, for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishesof 1:4 cement mortar. |
| 25 | M&L, for Non - skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. Make KAJARIA/SOMANY/JOHNSON/NITCO/ORIENT BELL |
| 26 | S&F, Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Make Jindal/Tata |
| 27 | M&L, for applying two coat of aluminium paint on mild Surfaces of any description, over 10cm in width or girth. |
| 28 | M&L, for Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.MAKE ASIAN/BERGER/NEROLAC |
| 29 | S&F,for 20mm dia. Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.Make KASTA/SUPREME/FINOLEX/ASHIRVAD/ASTRAL/JAIN IRRIGATION |
| 30 | S&F,for 15mm dia. Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.Make KASTA/SUPREME/FINOLEX/ASHIRVAD/ASTRAL/JAIN IRRIGATION |
| 31 | S&F, for 50mm dia. low density polyethylene pipes (LDPE) of pressure rating 6 kg/ cm2 laid in trenches. Make KASTA/SUPREME/FINOLEX/ASHIRVAD/ASTRAL/JAIN IRRIGATION |
| 32 | S&F, for 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and S&F, for 20mm dia. ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule . MAKE SINTEX/PLASTO/SUPREME/KAVERI/PRINCE |
| 33 | S&F,for 15mm dia. Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms/20mm- 75gms)bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms). |
| 34 | S&F,for drinking water cooler of capacity 120 litre and discharge of 60 litres/hour. MAKE BLUE STAR/VOLTAS/USHA |
| 35 | S&F,for fully automatic with auto cut off RO+ UV portable water purification system. (RO12 LPH) MAKE AQUAGUARD/KENT/HAVELLS/PUREIT |
| 36 | M&L, for waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end. |
| 37 | M&L, for 15mm dia. stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm-92gms) |
| 38 | M&L, for 20mm dia. stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/ 20mm-92gms) |
| 39 | Providing and laying Vitrified tilesin floor (Size of Tile 600 x 600 mm)(thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints( Make: Johnson/Kajaria/Somany/Orient/Asian/Nitco/)N.B. Shifting of all types of furniture (wooden/steel), keep aside, place in order after fixing of tiles including dismantling of branded furniture and refitting carefully. Any damage to furniture during shifting/dismantling/refitting shall be borne by contractor. |
| 40 | Supply & fixing of 6 to 32Amp rating,Single Pole, 240 V, 10KA \"C\" Curve miniature circuit breaker (MCB) in the existing MCB DB complete with connection, testing & commissioning.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 41 | Supply & fixing of 25 Amp, 240 V, Double Pole Residual Current Circuit Breaker with Overcurrent Protection (RCBO) for earth leakage, overload & short-circuit protection with Sensitivity 30 mA in the existing MCB DB complete with connection, testing & commissioning. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 42 | Cutting chases for concealed conduit wiring etc. and making good, cutting not exc 10 cm girth. |
| 43 | Material & Labour for one light or one fan point wiring in PVC conduit with 1.5 sq.mm single core FRLS copper conductor cables to be controlled by one switch. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 44 | Material & Labour for circuit/submain wiring alongwith earth wire with 2 x 2.5 Sq. MM + 1 x 2.5 Sq. MM Earth Wire of FR PVC Insulated copper conductor, single core cable inPVC conduit in recessed as required. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 45 | Material & Labour for Ceiling rose, 3 Phase/ 3 Pin, PVC/Polycarbonate, Isolated Body.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 46 | Supply & fixing of modular switches 1 Way, 6 Amp, 1 Modulein the existing switch board including connectio & testing. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 47 | Supplying & fixing of 2/3 Pin, 6 A, Combined Socket , 2 Module.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 48 | Supply & fixing of modular switches 1 Way, 16 Amp, 1 Modulein the existing switch board including connectio & testing. The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 49 | Supplying & fixing of 2/3 Pin, 6 A/16A Combined Socket , 2 Module.The material to be used shalle of ISI marked & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 50 | Material & Labour for modular white cover plate with frame, 2 Module. The material to be used shall be of ISI marked or conforming to relevant IS & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 51 | Material & Labour for modular white cover plate with frame, 6 Module. The material to be used shall be of ISI marked or conforming to relevant IS & of reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 52 | Material & Labour for Modular Metal Flush Box, 2 Module. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 53 | Material & Labour for Modular Metal Flush Box, 6 Module. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 54 | Supply & fixing of 1 x 20 Watt, 220 V AC, LED Light fittings with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make of LED Light fittings to be provided shall be of Phillips/Bajaj/Havells, Syska. |
| 55 | Material & Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduitpipe for loop earthing etc. as required with 4mm dia galvanized iron wire. |
| 56 | Supplying & fixing of 6 way double door, single pole neutral sheet steel MCB distribution board, 240 V, on surface/recess, complete with neutral bus bar, earth bus bar, din rail, powder painted including interconnection, testing & earthin etc. as required. It includes wall cutting & making good the same for fixing of above MCB distribution board. The material to be used shall be reputed make like Legrand, Havells, V-Guard, Polycab etc. |
| 57 | Supplying & fixing single pole blanking plate in the existing MCB DB Complete etc. as required. |
| 58 | Material & Labour for earthing with GI earth Pipe of 4.5 Meter Long, 40 MM Dia Including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.This also includes earth excavation, earth pit chamber construction and earth refilling. |
| 59 | Supply, installation, testing & commissioning of Submerssible water pump for Borewell with 1 Set of 1 HP Submerssible Pump, Submerssible Water Pipe: 350 Feets , Submerssible Power Cable: 350 Feets , 1 Set of Pump Starter with Water Level Controller. It includes requisite minor civil works to provision the water pump in existing Tubewell. The material to be used shall be reputed make & should be conforming to relevant IS. |