| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required. (Group B) |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (i) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 4 | Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 Pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 6 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc. as required. |
| 7 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 8 | Supplying and fixing 16 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCb/Isolator) |
| 9 | Suppying and fixing 5 A to 32 A rating, singlepole, 240/ 415 V, 10 KA,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 10 | Suppying and fixing 5 A to 32 A rating, doublepole, 240/ 415 V, 10 KA,\"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 11 | Earthing with G.I earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 12 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (i) 2 X 25 sq. mm (22mm) |
| 14 | Supply,Installation,TestingandCommissioningof1200 mmsweep,BEE5starrated,ceilingfanwithBrushLess Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long downrod, 2 nos. canopies, shackle kit, safetyrope,copperwinding,PowerFactornotlessthan 0.9,ServiceValue(CMM/W)minimum6.85,Airdelivery minimum215 CMM,350RPM(tolerance asperIS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories includingsafetypin,nutbolts,washers,temperature rise=75degreeC(max.),insulationresistancemorethan 2megaohm,suitablefor230V,50Hz,singlephaseAC Supply, earthing etc. complete as required. |
| 15 | Supplying, installation, testing and commissioning of energy efficient pre wired LED tubelightof 22 W LED of 5700 to 6500 k, decorative slim liner LED batten,polycarbonate housing & integrated electronic driver completed with all accessories including etc. as required. (Model- Philips/ Crompton / Havells/ Bajaj/ JAGUAR/ HALONIX. |
| 16 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 2x 25 sq.mm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 17 | Supplying and fixing of one number PVC insulated and PVCsheathed / XLPE armoured power cable of 1.1 KV grade of 2x25 size in the existing RCC/ Hume/ metal/ PVC pipe etc as required. |
| 18 | Supplying and laying of G.I pipe of 40 mm dia (medium duty) G.I pipe in floor/ wall/ road for protection of UG cable including cutting the wall/ floor/ metalled road and making good the same as required. Make jindal/ Tata/ Bansal/ Hindustan. |
| 19 | Supplying, installtion, testing and commissioning of 25 watt LED street light luminaire with power lens, prewired, Led type street light fittings, complete with all accessories and 32 mm dia (nominal) \"B\" class GI pipe bracket, reduser for mounting fitting on wall including bending the pipe to the required shape and connection with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required. |