| 1 | Taking down Cement Plaster of any descrip-tion on Brick Walls, Concrete Surfaces includ -ing racking out joints, hacking for key, scrubb -ing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed. |
| 2 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm complete all as specified and directed. |
| 3 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 4 | M&L Plain Cement Concrete type B-1, (1:2:4) (20mm graded crushed stone aggregate) as in Coping bed plate,hold fast etc,block benching,channeling slightly rounded or chamfered angle and throating including form work and finishing all exposed faces of cement concrete complete all as specified and as directed. |
| 5 | S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 6 | M&L 1.50mm thick power coated aluminium , three track sliding window with three nosshutters made ofaluminium section as per drawing no CWE/KOL/TD-33 of section no 1F-1F including necessary jointing cleats, glazing clips, rubber neoprene packing, roller,locking arrangement, handles 2 Nos , anodised aluminium snap beading screws etc.Complete all as specified and as directed.Note Nos :- (i) All window memberincluding fitting & fixture i.eframe, track, shutter frame, etc shall be deem toincluded quoted rate. Only measure opening size of window.(ii)Only Glass for window & wire mesh shall be measure and paid separately under relevant items of BOQ . |
| 7 | S&F Powder coated aluminium ventilators with louvers and glazing including frame of section over all size of window 600X450mm complete with following specification.(a) Alu frames of size 45x45x1.2mm (b) Rail & Stile 45x45x1.2mm thick (c) 4.80mm thick frosted sheet glassNote :- All ventilators/louvers memberincluding fitting & fixture shall be deem toincluded quoted rate. Only measure opening size of ventilators/louvers |
| 8 | M&L Mild Steel Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 9 | M&L Rendering15mm thick in Cement Mortar 1:6 on Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and smooth without using Extra Cement complete all as specified and as directed. |
| 10 | M&L 15 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete externalsurfaces in two layers (each 10+5 mm thick) finished even and smooth without using extra cement using water proofing compound on top layeras per manufactures instruction on external wall surface completeall as specified and directed. |
| 11 | \"Supply only\" liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA |
| 12 | S&FTinted glass with sheet glass 4.80mm thick , pin head type and glazing in squaresexc 0.5 sq. M in each panecomplete all as specified and as directed. |
| 13 | M&L preparing new plastered surfaces of wall and and applying Two Coats of Distemper Oil Emulsion over a coat of primer over andapplied over and including 2mm thick water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and as directed. |
| 14 | M&L Preparing new plaster surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work/new work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 15 | Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge. |