Tender For Provision Of Addn/Alt To Cook House Shelters (T-6/1 And T-6/2) For Converting Into Combined Cooking Area And Dinning Hall, One Sentry Post Box (02 Persons), Hardstanding And Entry Gate With Side Wall And 03 X History Walls Under Ge (North)

Issued by Statutory Bodies & Commissions/Committees · binnaguri, West Bengal
Tender Value
44.40 Lakhs
Estimated cost
Bid Submission
20 Feb 2025
0 days left
EMD
88800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
binnaguri → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Provision Of Addn/Alt To Cook House Shelters (T-6/1 And T-6/2) For Converting Into Combined Cooking Area And Dinning Hall, One Sentry Post Box (02 Persons), Hardstanding And Entry Gate With Side Wall And 03 X History Walls Under Ge (North) Binnaguri

BOQ

Name of Work : PROVISION OF ADDN/ALT TO COOK HOUSE SHELTERS (T-6/1 & T-6/2) FOR CONVERTING INTO COMBINED COOKING AREA & DINNING HALL, ONE SENTRY POST BOX (02 PERSONS), HARDSTANDING AT VEH INSP AREA AND ENTRY GATE WITH SIDE WALL AND 03 X HISTORY WALLS IN FRONT OF CHANAKYA HALL UNDER GE (NORTH) BINNAGURI
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and as directed.
2Material and labour for glazed ceramic coloured of size 300 x 450 mm x 7 mm thick ) as in vertical surfaces of walls such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over andincludingcement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. Note: Screed bed shall also deemed to be included in the quoted rate by the contractor.
3M&L non skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar1:6 complete all as specified and as directed. Note: Screed bed shall also deemed to be included in the quoted rate by the contractor.
4M & L for 18 – 20 mm thick Diamond cut Kota stone slab as in flooring over 15mm thick screed bed or bedding layer in CM (1:6) as in floor, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and as directed. Note: Screed bed shall also deemed to be included in the quoted rate by the contractor.
5M & L for 18 - 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:4)including rounded the exposed surfaces of granite complete all as specified and as directed.
6Demolition of brick work built in cement mortar of any description complete all as specified and as directed.
7M&L for brick works with fly ash bricks straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
8M&L for brick works with fly ash bricks straight or curved on plain exc 6mmean radius built in cement mortar 1:6 complete all as specified and as directed.
9All as per item Ser No. 8 above but except bricks complete all as specified and as directed. Note: The bricks obtained from demolition shall be reused.
10Taking down cement plaster on wall / ceiling of any description includingracking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
11M&L for 15 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers first layer of 10 mm thick and top layer of 5 mm thick plaster with water proofing compound @200 ml per bag of cement or as per manufacturer\"s instructions finishing the surface even & fairwithout using extra cement complete all as specified and as directed. Note : Water Proofing Compound shall be measured and paid separately.
12Supply only water proofing compound complete all as specified and as directed.
13M&L 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and as directed.
14M&L for applying two coats of exterior emulsion paint (weather coat) over a coat of exterior primeron a new plastered surfaces of walls including projection, RCC jalies & post etc including necessary preparation of surfaces complete all as specified and as directed.
15M&L preparation of newly plasterd surface applying two coats of oil bound distemper over a coatwall care putty over plastered surfaces including priming the surface complete all as specified and as directed.
16M&L preparation of old plastered surface applying one coat of acrylic based distemper over plastered surfaces complete all as specified and as directed
17M&L cement concrete type C2 1:3:6 40 mm graded aggregate 75mm thick as in floor or in path finished the surface even and smooth without using extra cement complete all as specified and as directed.
18M&L Sand filling under floors or in foundations including watering and consolidation includingspreading and leveling in layers n.exc 40 mm thick complete all as specified and as directed.
19Takingup or down GI 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and as directed.
20Refixing old 15mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) complete all as specified and as directed.
21S&F15mm bore pipe medium grade galvanized iron water tube with all fittings laid in floors fixed to wall etc complete all as specified and as directed.
22S & F 15mm bore PVC Connection with PTMT nut of length 600 mm complete all as specified and as directed
23Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified and as directed.
24Refixing old 20mm bore steel tubing and connections in new or old position (walls, ceiling, floors etc.) complete all as specified and as directed.
25S&F of tubes, medium grade, 20 mm bore, galvanized, with all fittings and fixed to wall and ceilings or laid in floors complete all as specified and as directed.
26Dismantling existing PVC water tanks exc. 500ltrs and n. exc. 1000 ltrs complete all as specified and as directed.
27S&F 1000 ltrs rotational moulded polyethylene water storage tanks in triple layered (cylindrical vertical with closed top) includingconnecting up pipes securing access covers etc complete all as specified and as directed.
28S&Fvitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size including CP waste coupling, PVC connection 450 mm long, waste pipe removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified and as directed.
29S&F pillar taps 15mm dia, cast copper alloy with capston heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe 15mm bore complete all as specified and as directed.
30S&F in repairs 15mm dia fancy type bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
31S&F in repairs15 mm dia CP cast copper alloyangle cockscrewed for iron pipe and fixed complete all as specified and as directed.
32S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420 mm bowl size410mm x 330 mm x 160 mm complete all as specified and as directed.
33Supply and fixing in repairs 600x450 mm mirror of selected quality glass, mounted on wall with chromium plated brass screws and cup washers including pvc frame etc complete all as specified and as directed.
34Taking down chowkat with shutter exc 1.5 sqm and n. exc. 4.00sqm each and removing from site complete all as specified and as directed.
35S&F for pressed steel frames of thickness 1.25 mm for doors with one or more rebates including necessary lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 125 x60 mm complete all as specified and as directed.
36M & L for providing plain cementconcrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and as directed.
37S&F 30 mm thick flush shutter, solid core construction with block board case & plywood face panels commercial type on both side complete all as specified and as directed.
38M & L for framed work as in doors frame of angle or other section conforming to Fe 410-W(Gde-E- 250) quality-A with gusset plates, rails, braces, etc. including fixing of steel hinges or other door fittings complete all as specified and as directed. Note: Door fittings like hinges, tower bolt etc shall be measured and paid separately.
39S & F35 mm thick 2nd class hard wood glazed and skeleton shutter , open rebated and prepared to receive glass, gauze, etc 9without sash bars), edges of framing plain, chamfered rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and as directed.
40S& F of 2nd class hard woodsmall fittings such asbrackets of any type, latchand hinge blocks, shapeddoor and window stopsand the like, including allnecessary\" labours; articles n exc 200 cu. cm each complete all as specified and as directed.
41S&F of 100 mm long stainless steel butt hinges complete all as specified and as directed.
42S&F in repair anodised aluminium frame powder coated of size 100x44x1.5mm thick made of square tubular coated aluminium section for doors with one or more rebates, jointing cleats for fixing etc and provision of aluminium door shutters (single/double) including jointing cleats, glazing clips, rubber gasket aluminium anodised snap beading, nylon wool pile weather strip, locking arrangement, handle of size not less than 200 mm,12 mm thick prelaminated partical board fixed in panels withPivot stainless steel floor door closer for one shutter etc including taking down of old shutter complete all as specified and as directed.
43S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and as directed.
44S&F aluminium handles 150mm size cast type anodised complete all as specified and as directed.
45M&L for sliding door bolt of 300mm long plate aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
46M&L for preparation of new wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
47M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
48S & F in repair stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and as directed
49S & F stainless steel wire cloth 0.36 nominal dia wire & average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and as directed
50S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e glazed & wire gauged shutter including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS guard bar/grill etc complete including one shop coat of anti corrosive zinc chrome primer complete all as specified and as directed.Notes:- (a)Rate quoted shall be deemed to be including of all fittings fixtures . (b)Glass, wire mesh, MS Guard bar/ Grill and painting shall be measured and paid separately under relevant items of this schedule.(c)PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of schedule.
51All as per Item Ser No. 50 above but with glazing bars complete all as specified and as directed.
52Supply only sheet glass 3 mm thick ordinary quality and glazing with oil putty in squares n exc 0.5 Sqm in each pane complete all as specified and as directed.
53M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
54M&L for preparation of old painted to steel surfaces of any description not otherwise described, over 10 Cm width or girth and applying one coat of synthetic enamel paint on the same complete all as specified and as directed.
55S&F ofCurtain rod of stainless steel 25 mm dia chromium plated with fixing brackets , stop , rollers etc. clamps etc. Complete all as specified and as directed.
56S&F stainless steel curtain rod holding brackets heavy duty fixed to wall with stainless steel screws etc complete all as specified and as directed.
57S&F in repair stainless steel finial type fancy stop and suitable for curtain rod 25mm dia etc complete all as specified and as directed.
58S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed.
59S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and as directed.
60Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
61S&F of 4mm thick\"E\" classic designer board false ceiling in repair with powder coated GI snap grid frame work of grid size 600 x 600 mmcomplete all as specified and directed including all necessary drilling and necessary arrangement to fix items as under :-(a)27x27x0.55 mm thick GI angle powder coated duly plugged @ 600mm centre to centre alongwith perimeter of wall.(b) 25x25x0.55 mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders (n.exe 1.2 mtr length) with adjustable clamps and dash true fastners plugging in RCC slab/wooden truss/A.I Runner of slopped roof placed @ 600mm centre to centre from perimeter of wall.(c) Fixing of 4mm thick AC \"E\" Classic designer board of approved texture and finished complete.Note: The complete ceiling work shall be done as per manufactures instruction and as directed.
62Demolition of cement concrete of any description and in any position not otherwise specially provided for as in Floors, surface channel etc complete all as specified and as directed.
63M&L for RCC type A1,1:1.5:3 using 20mm graded aggregate Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and as directed.
64M&L for form work to Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and as directed.
65M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
66S&F steel work in tubular trusses MS pipes in vertical column, parlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161 of 1979 grade st 240 with one shop coat complete all as specified and as directed.
67S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
68Supply and fixedpre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in as in ridges, valley, eaves, valley gutter, gutters etc with self tapping screws complete all as specified and as directed.
69S & F in110 mm dia PVC bends/shoe of any radius with access door complete all as specified and as directed.
70S & F in100 mm dia 1 mm thick mild steel drop ends ( for spigot or socket ends) or nozzles complete all as specified and as directed.
71S & F in100 mm dia 1 mm thick mild steel stop ends (for spigot or socket ends)complete all as specified and as directed.
72S & FMild Steel flat iron brackets supports or stays for valley gutter or as in wind tie confirming to Fe 290 Gde E 165 complete all as specified and as directed.
73Surface Dressing n. exc 15 cm deep in soft/loose soil complete all as specified and as directed.
74Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and as directed.
75M&L for PCC in cement concrete in foundation, filling and mass concrete type D-2, 1:4:8 using 40mm graded aggregate as in foundation complete all as specified and as directed.
76Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
77Removing excavated material (soil)not exc 50 m depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
78M&Lfor RCC M25 in foundation includingraft, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles & mass concrete complete all as specified and as directed.
79M&L for RCC M25 (Design Mix) in columns, pillars, piers, posts, struts etc. complete all as specified and as directed.
80M&L for RCC M25 (Design Mix)in beams, cantilevers, bressumers, lintels over 1.5 m span etc complete all as specified and as directed.
81M&L for RCC M25 (Design Mix)in chajjas etc complete all as specified and as directed.
82M&L for RCC M25 in slabs supported on walls, beams, columns in floors, roofs , landings, balconies, canopies, deck slabs, shelves & the like complete all as specified and as directed.
83M&L for formwork to concrete foundations, footings, bases of columns, rafts & raft bases , sides & soffits of foundations , plinth beams and similar works in fair finished surface complete all as specified and as directed.
84M&L for formwork to sides of pillars, posts, struts, piers, columns etc rough finished surface square, rectangular on plan or polygonal complete all as specified and as directed.
85M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges rough finished concrete surface complete all as specified and as directed.
86M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surface of concrete complete all as specified and as directed.
87M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface of concrete complete all as specified and as directed.
88M&L for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
89M&L for mild steel TMT bars 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
90M&L for earth filling under floors in layers n.exc 15cm thick, spread, leveled and rammed including watering as required in layers n exc. 25 cm thick as required complete all as specified and as directed.
91M&L Cement concrete type C1 1:3:6 (using 20 mm graded aggregate) 75mm thick as sub base complete all as specified and as directed.
92M&L for 25mm thick PCC (1:2:4) type B-1 with using 20 mm graded stone aggregates as in sub base of flooring, finished even and rough to receive the top layers complete all as specified and as directed.
93M&L Non - skid Ceramic tiles(colour) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and 15mm thick screed bed or bedding layer in CM 1:6 for laying floor finishes jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed.
94Material and labour for 75mm thick PCC (1:3:6),type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection; pathway / hard standing etc laid in bays / panels not exc. 2.00 Sqm eachincluding construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smoothwithout using extra cement complete all as specified and as directed.
95M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying acrylic polymer modified, fibre reinforced waterproof coating brush bond Roof Guard, finished even and smooth without using extra cement complete all as specified and as directed.
96M&L for providing and applying single componentacrylic polymer modified, fibre reinforced waterproof coating Roof Guard or technically equivalent in 4 coats of application(a) applying primer coat with Primer @ 0.3 kg /sqm (b) over priming coat applying roof guard as specified below or manufacturer instructionswith fibre reinforcement a width of approx. 1m @ 0.75kg/sqm on the flat or verticalsurfaces over parapet wall and ensure that there are no bubbles of creases. Overlapping of the fibre is a minimum of 50mm and allow this coat to dry for a period of 2-6 hrs depending on the atmospheric condition. (c) Applying second coat of roof guard @0.75Kg/sqm.(d) Applying final coat ofprimer @ 0.08kg/sqm after 2nd coat has dried properly.Note : Water Proofing treatment shall be carried out by authorized applicator approved by the manufacturer.
97M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and fair (without using extra cement) complete all as specified and as directed.
98M&L for three coats ofwhite wash on walls over newly plastered surfaces of wall includingpreparation of surfacesetc complete all as specified and as directed.
99All as per item Ser No 98 above but three coats of white wash on ceiling complete all as specified and as directed.
100M&L for 25mm thick pre-polished and chemically treated smooth finish exterior grade coloured chequered tile (300X300)as in pathincluding 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
101Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outin Soft/loose soilcomplete all as specified and as directed.
102M&L for preparation of new/untreated surfaces of walls and applying two coats of cement based paints over a coat of alkali resistance primer includingwashing floors, cleaning glass, joinery electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
103M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
104M&L for 100 mm thick cement concrete type D2 1:4:8with 40 mm graded stone aggregate as in Sub base etc complete all as specified and as directed.
105Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M40 grade with approved colour, design & pattern as in footpath, parks, lawns etc. of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed.
106M&L for plain cement concrete 1:3:6type C2(using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
107M & L for preparing new Plasteredsurfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) complete all as specified and as directed.
108Providing and laying of300x300 mmx 10mm thick Anti-Skid pavement tile in approved color & Shade and in anti skid finishset and jointed in neat cement slurry and pointed in white cement & pigment to match over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. Note: Design/pattern shall be as approved by GE at the time of execution)
109M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, chajja/sunshade, shelves and railings , newels, balustrade & the like complete all as specified and as directed.
110M&L for formwork toFins, fascias, louvres, parapets, chajja/sunshade, shelves and railings , newels, balustrade & the like Fair finished surfaces of concrete flat complete all as specified and as directed.
111M&L for 1st quality double charged/ultra charged Vitrified Ceramic tiles dark shade 9-10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 Sqm in floors/Skirtingetc set & jointed in neat cement slurry & pointed in white or coloured cement to match. over 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
112M&L for 1st quality double charged/ultra charged Vitrified Ceramic tiles dark shade 9-10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 Sqm in wall/Skirtingetc set & jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified and as directed.
113M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces to receive a wall tiles using cement mortar 1:4 complete all as specified and as directed.
114M&L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings;framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
115M&L for preparation of new primer applied steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint complete all as specified and as directed.
116Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
117ELECTRIFICATIONTaking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
118M&L for point wiring complete for one power point for one metal plug & socket for geyser/AC/Electric Chimney point on independent board with 4.0 sqmm multistranded copper conductor single core PVC insulated unsheathed FR LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.00 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fixing for metal plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
119M&L for point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed FRLS cable ,single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC medium grade casing caping (Double lock pattern) and accessories (ISI Marked) on walls/other surface etc includingprovn of1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable FRLS as earth continuity conductor (green in colour) & PVC switch box heavy duty of appropriate size on wall/other surface (ISI Marked) for housing switches/socket outlet, Fan regulators etc complete all as specified and directed for the following :-
120All as per item Ser No 119 above one light point controlled by one way switch 5/6 amps complete all as specified and as directed.
121All as per item Ser No 119 above one ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps complete all as specified and as directed.
122All as per item Ser No 119 above one socket out let 5/6 amps point on the independent board complete all as specified and as directed.
123All as per item Ser No 119 above one socket out let 5/6 amps point on the same board complete all as specified and as directed.
124All as per item Ser No 119 above but wiring with 2.5 sq mm single coremultistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed.
125M & L for shifting of existing point wiring such as light, fan and socket to the new location with its all connected accessories such as boxes , wire ,casing capping etc without damaging it complete all as specified and as directed.
126S&F of switch piano flush type 5/6 amps single pole one way complete all as specified and as directed.
127S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
128S&F Switch socket combination2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and as directed.
129S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
130S&F of switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
131S & Flamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
132S&FLED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
133S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
134S & F Recess mounting flat panel 34 Watt LED fitting (2\"X2\") for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection complete all as specified and as directed.
135S&F IP 20, class I, LED light 1X20 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
136S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete includingremoval of old unserviceable fitting complete all as specified and as directed.
137Materialand labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) ofsize not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits &making good to walls, floors etc complete, including taking down old unserviceable aluminium submain wiring all as specified and as directed. Note: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one runof PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles complete all as specified and as directed.
138S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB\"S/lsolators with andincluding taking down old one complete all as specified and as directed.
139S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
140S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed.
141S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
142S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unserviceable one complete all as specified and as directed.
143Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on complete all as specified and as directed.
144S&F of ceiling fan with all accessories 230 volts 1200 mm sweep BEE 5 Star Ratedconforming to IS-374 :1979 complete pre-wired with three core cable complete all as specified and as directed.
145Supply & fix of Metal Exhaust fans AC single phase 230 Volt of size 300 mm sweep, 900 rpm, Heavy duty with and including MS louver, Cutting of the wall should not be less than25mm the sweep diameter complete all as specified and as directed.
146S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, includingnecessary connection complete all as specified and as directed.
147S & F SS Wall/Ceiling Mounted commercial type Chimney hood with SS Filter of size 89\"(L)(7.42\") x 36\"(W) x18\" (H) to dischargeout hot gases to the atmosphere complete all as specified and as directed.
148M & L for ducting of galvanized iron of thickness 22 gauge with all hanging arrangement such as tie rod, nuts, screws etc for discharging out exhaust gases from the chemney to the atmosphere complete all as specified and as directed.
149S & F Axial fan Drive with direct blade connected with 1 HP motor single phase 230 V , 50 Hz with all accessories complete all as specified and as directed.
150S & F automatic star delta Stater for Axial fan Drive with direct blade connected with 1 HP motor with all accessories complete all as specified and as directed.
151Supply installation, commissioning and testing of electric water heater, storage vertical type, BEE 5 star rated 25 ltrs capacity 230 volts AC 50 Hz comprising of high wattage heating element for instant heating extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non- ferrous pressure plate with and including provision of 04 Nos grouting bolts suitably flush to wall and two nos of connecting pipe, any other surfaces 25 lts BEE 5 Star rated complete stranded copper conductor cable/ flexible chord complete all as specified and as directed.
152M&L for GI water tubing medium grade 15 mm dia fixed on wall with all fittings and fixtures complete all as specified and as directed.
153S&F stop valve but fancy type, chromium plated, screwed down (CP) of size15 mmfancy type complete all as specified and as directed.
154M&L for LED garden light 08 watt made up of high grade unbreakable polycarbonate material, IP-65 protection, cone series innovative design with uniformly lit diffuser at the upper portion complete all as specified and as directed.
155M&L for PVC insulated unarmoured copper conductor cable4 sq mm 2 core including taking out old unserviceable complete all as specified and as directed.
156M&L for PVC conduit pipe heavy duty 25 mm diaincludingtaking out old unserviceable conduit complete all as specified and as directed.
157Taking out old unserviceable cable of any size carefully from trenches after disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note :The Excavation and earth work shall be measured and paid separately under relevant item of Schedule.
158Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed. Note: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\".
159Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
160Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
161M & L for horizontal boring across the existing road without disturbing the road surface for insertingGI pipe complete all as specified and as directed. Note: (a) Removal of surplus soil shall be deemed to be include in the unit Rate. (b) GI pipe will be measured and paid separately under relevant item of Sch \"A\".
162M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
163S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete includingremoval of old unserviceable fitting complete all as specified and as directed.
164S&F wall mounting fan 400mm sweep 230 volts 50 Hz including fixing clamp and with all accessories complete all as specified and as directed.
165Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with strandedaluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and as directed. Note: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule.
166Material and labour for LED flood light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 3000 lumen, system wattage 30 Watt (Warm White), Ingress protection IP-66 with all accessories including taking down unserviceable light fitting and removing from site complete all as specified and as directed.
167Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulatedPVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note: GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule \"A\".
168M&L for one run of 1.5 Sqmm 2 core (Nominal Area) PVC sheathed multi stranded nuarmoured aluminium conductor cable LT 1100 Volts grade confirming to IS-7098 (FRLS) (inner sheet) in existing position from pole junction box to light fitting complete all as specified and as directed.
169S&F UPVC pipes of pressure rating 10 kgf/cmsq of 20mm bore and 3mm thick complete all as specified and as directed.
170S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB\"S/lsolators with and including taking down old one complete all as specified and as directed.

AI Tender Summary

OUR REF NO 47470406
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.40 Lakhs
LAST DATE 20-02-2025
Authority
Authority Name Military Engineer Services
Work Description Provision Of Addn/Alt To Cook House Shelters (T-6/1 And T-6/2) For Converting Into Combined Cooking Area And Dinning Hall, One Sentry Post Box (02 Persons), Hardstanding And Entry Gate With Side Wall And 03 X History Walls Under Ge (North) Binnaguri
Basic Detail
Tender No NIT No. 8701 / 89 / 2024-25 / 14 / E8
Bidding Type Tender
Location
City binnaguri
State West Bengal
Key Dates
Publish Date 30 Jan 2025
Submission Date 20 Feb 2025
Open Date 22 Feb 2025
Finance
Tender Value 44.40 Lakhs
Tender Fee 500
EMD 88800
Exemption Available
Document List
Tender89.pdf
Tendernotice_1.pdf
54eb0b80-0a93-4f91-924a-0abe13da2acd.html
BOQ_778883.xls
credit89.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 30, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 20, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 22, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tender89.pdf

pdf

Tendernotice_1.pdf

html

54eb0b80-0a93-4f91-924a-0abe13da2acd.html

xls

BOQ_778883.xls

pdf

credit89.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders