Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-02-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-02-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling of wall and ceiling boards (fibre pulp insulation etc) any thickness including cover fillets all as specifed and directed. |
| 2 | Taking down Chowkhats and shutters of windows/ventilators with wire mesh / glassand MS grills of any size including all fittings and fixtures all as specified and directed. |
| 3 | Demolition of brick masonary built in cement mortar all as specifed and directed. |
| 4 | Demolition of cement concrete (unreinforced) below or above ground level n.exc 15cm thick and removing rubbish to a distance n.exc 50m at low lying area all as specified and directed |
| 5 | Dismantling plain or corrugatedsteel sheeting, any gauge, thickness, including Nainital or similar patteren roof coverings including scafoldings of any height all as specified and directed. |
| 6 | Dismantling of framed work of timber in scantlings 40 sq. cm and over in section, in any position all as specified and directed. |
| 7 | S&F 3 mm thick panel of any type, pattern and shape Aluminium Composite Panel (ACP), aluminium thickness of0.5mm, Front side finish of aluminum roll coated with Plain / coloured / wooden texture PE / PVDF, Core material ofNon-toxic polyethylene, Macromolecular lamination film, Rear side of Aluminum coated with primer and including frame work using of Fasteners, including concealed screws, nuts, bolts and other items requiredfor connecting aluminium to aluminium / steel / wooden / ply board, Blind rivets all fixing anchors, brackets and similar attachments used in the erections, shall be of aluminium, non-magnetic stainless steel, zinc coated steel, for fixing in both internal / external wall cladding complete weather proofing sealant of a polyurethane elastic joint / structural silicone sealant / pre-formed gasketsto the Horizontal & Vertical Joints in the Aluminium cladding / facade as per manufacturer\"s instructions all as specified and directed.Note : 1. The unit rate quoted is deemed to be inclusive of all necessary fixing acceserries mentioned in the description of work and scaffolding works at any height for installation.2. For payment purpose panels areas will be measured on one side only. |
| 8 | S&F SS 304 Grade metal letters of height 200mm with PU paint to match the logo colours, mirror polish finish, anti rust and including necesssary arrangements to fixing in walls, using scaffolding at any height all as specified and directed. |
| 9 | M&L brickwork with fly ash bricks, straight orcurved on plan exc 6m mean radius built in CM 1:6 all as specifed and directed. |
| 10 | M&L broken stone or bouldershardcore of gauge nexc. 63 mm,deposited, spread and levelled inlayers n exc. 15 cm thick, watered and rammed to a true surface using power roller all a specified and directed. |
| 11 | M&L 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) and similar work all as specified and directed. |
| 12 | M&L earth filling in floors etc, spreading and leveling in layers, well ramming including watering as required all as specified and directed. |
| 13 | M&Lin repairs coloured double charged polished glazed vitrified tiles 10 mm thick (Square/rectangular) polished, area of each tile exc 0.36 sqm but not exc 0.72 sqmin floors,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles including dismantling all as specifed and directed. |
| 14 | M&L in repairs coloured double charged digital glazed vitrified tiles 10 mm thick (Square/rectangular) polished, area of each tile exc 0.36 sqm but not exc 0.72 sqmin vertical surfaces such as skirting & dados,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles including dismantlingall as specifed and directed. |
| 15 | S&F marble UV laminated sheet 1.00 mm thick UV coating, water resistant, termite resistantfix with adhesive all as specified & directed. |
| 16 | S&F in repairs 25 mm dia stainless steel decorative type curtain rods and all other connected works all as specified and directed. |
| 17 | S&F in repairs 25 mm dia stainless steel decorative type curtain Brackets,including fixing in position and all other connected works all as specified and directed. |
| 18 | S&F 18 to19 mm thick HD board, prelaminated one side with decorative choice lamination & other side high glossy acrylic sheet of 3mm thick, exterior grade, fixed with screws to frame work as in cup borad & kitchen cabinet shutters and all other similar works all as specified and directed. |
| 19 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge. |
| 20 | S&FPre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPA as in roof coverings /claddings to wall, fixed with self tapping screws including scafoldings of any height all as specified and directed. |
| 21 | M&L for preparation ofnew steel surfaces of any description over10 cm width orgirth, not otherwise described and applying two coat ofsynthetic enamel paint over a coat of red oxide, zinc primer all as specifed and directed. |
| 22 | S&F Partial overlay / fully overlay hydraulic soft closing concealed hinges having size 103mm x 64mm finish of nickel/silver all as specified and directed by Engg-in-charge. |
| 23 | S&F factory made 35 mm thick 2nd class hard wood plain framed panelled shutters (any numbers of panels) with lock rail and panel of 9mm thick B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS :1003(Part-I) kiln seasoned and chemically pressure treatedall as specified and directed. |
| 24 | M&L for preparation of newwood or wood based surfaces,ofany description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed. |
| 25 | M&L for machine cut, polished cudappah stone work 20 to 25 mm thick (table rubbed and polished) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in kitchen platform, flooringand all other similar works, including laying over 15mm thick cement mortar (1:6) all as specified and as directed. |
| 26 | M&L Granite (of any type and colour) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar worksin approved design laid over 20 mm thick screed bedin cement mortar 1:4 all as specified and directed. |
| 27 | M&L for french polishing on surfaces of any description, width or girth including cleaning and preparing the surfaces including a coat of wood filler on old wooden surfaces with one or more coats all as specified and directed. |
| 28 | M&L for 12 mm thick ready mix plaster in single layer on brick wall or concrete surfaces including making groove of appropriate size, on other than fair faces of concrete/brick surfaces (internal surface) and finished even & smooth witjhout using extra cement complete including taking down all as specified and as directed. |
| 29 | M&L forpreparation of newly plastered wall surfaces and applying a coat of wall care putty (Birla White Wall care or equivalent) 2mm thick ( in two coat of 1 mm each coat ) avg on plastered surfaces including rubbing with sand paper, preparatory to distempering and applying two coats of acryilic emulsuion over a coat of alkali resistant primingpaint all as specified and directed. |
| 30 | M&L for Providing and fixing colourPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making, provision for fixing of fittings where ever required including the cost of EPDM rubber/ neoprene gasket required with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all as per architectural drawings and the directions of Engineer-in-Charge.Note : (i) Glass panes will be measured & paid separately(ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clips, hionges, handle. However it will not be weighted and not paid separately.(iii)All other minor details including cost of locking arrangement shall be included in the quoted rate. |
| 31 | S&F sheet glass, ordinary quality, 5.5 mm thick, plain or frosted on one side and glazed with oil putty or fixed with rubber beading in square exc 0.5 Sqm in each pane or as required all as specified and directed. |
| 32 | S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm of approved design and fixed with aluminium windows all as specified and directed. |
| 33 | S&F in repairs 12mm thick, toughened glass for door shutters, partitions in bathroom or other places, shelves, table top etc and in similar work with and including fitting and fixtures such as glass handles SS studs, fittings for door pivots, spring machine (bottom and top ) and locking arrangmentall as specified and directed. |
| 34 | S&F Sun control film, 50 micron non reflective type, sticked to glass as per manufacturers instructions all as specified and directed. |
| 35 | S&F in repairs SS 202 Stain finish Handle D type, 25mm dia 600mm longfor glass shutter all as specified and directed |
| 36 | M&L 10 mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre with & incl Hangers 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long all as specified and directed. |
| 37 | Extra over above items No. 37 for any sunk or raised moulding all as specified and directed. |
| 38 | M&L for complete removal andpreparation of surfaces of Old plastered surfaces wall/chajja andapplying one coat of acrylic exterior primer and applying two coats of acrylic emulsion exterior grade (100%) all as spacified & suggested by the manufacturers at any height including necessary scaffolding all as specified anddirected by Engineer-in-Charge. |
| 39 | M&Lfor two coats ofoil bound distamper over 1 mm thick wall care putty on old plastered surfaces including preparation of surfaces all as specifed and directed. |
| 40 | S&F 40 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, both faces is covered with decorative face Laminate both side with incl 5mm thick teakwood lipping all around / frame to match on both side with supply & fixing stainless steel 7.5 inch Mortice 7 lever door lock, double action with handle all as specified & directed. |
| 41 | M&L for preparation of newwood or wood based surfaces,ofany description, not otherwisedescribed over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specifed and directed. |
| 42 | S&F in repairs100 mm butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 all as specifed and directed. |
| 43 | S&F in repairs 200mm size brass handle cast type polished brightall as specifed and directed. |
| 44 | S&F in repairs 300 mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts and fixed all as specifed and directed. |
| 45 | S&F Aluminium100mm long butthinges,medium weight, cold rolled mild steel all as specifed and directed. |
| 46 | S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section all as specifed and directed. |
| 47 | S&F 150mm long anodised aluminium alloy handles, fabricated type all as specifed and directed. |
| 48 | M&L precast cement concrete block masonry with solid blocks with 390x300x200 mm size, exc 10 cm in width and setting in cement mortar 1:4 type C1 (1:3:6)all as specified & directed |
| 49 | M&L PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete all as specified and directed. |
| 50 | M&L for providing and fixing precast cement concrete louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately) |
| 51 | Supply only integral waterproofing compound all as specifed and directed. |
| 52 | M&L RCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) works as in columns, foundations, beams, slabs, parapet, staircase all as specified anddirected by Engr-in-Charge. |
| 53 | Use & waste special water tight centering and shuttering including bolting, strutting, propping etc. so as to withstand a pressure of 0.1 Mpa including removal of form work at all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and directed by Engr-in-Charge. |
| 54 | M&L mild steel TMT bars 10mm diaand over, cut to length, bent to shape required,including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed. |
| 55 | M&L mild steel TMT bars of any dia in stirrups, spaces and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed |
| 56 | S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins whereconnected to common rafters and running railsand guides for sliding doors; fixed with anglecleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality- A including welding, nuts and bolts all as specified and directed. |
| 57 | M&LGranite (of any type and colour) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid in floors/Jambs/WHB conters and all other similar works in approved design over 20 mm thick screed bedin cement mortar 1:4 all as specified and directed. |
| 58 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for all as specified and directed. |
| 59 | M&L framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe Fe 290 Gde E-165 all as specified and directed |
| 60 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of epoxy paint over two coat of epoxy primer all as specified and directed. |
| 61 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed |
| 62 | Removing excavated material of soil n exc.50m and depositing where directed at alevel n exc. 1.5 m above the startingpoint all as specified and directed |
| 63 | M&L broken stone or bouldershard core of gauge n exc. 63 mm,deposited, spread and levelled inlayers n exc. 15 cm thick, watered and rammed to a true surface using power roller all a specified and directed by Engr-in-charge. |
| 64 | M&L for READY MIXED CEMENT CONCRETE DELIVERED ON BUNKER M-7.5type 1, 1:4:8 (using 20 mm graded crushed stone aggregate)as in flooring and all other similar works all as specified and directed. |
| 65 | S&F machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness , M 35 grade with grey cement and pigment with joint filled all as specified and directed |
| 66 | M&L crushed stone sand filling under floors or in foundations including watering and consolidation all as specified & directed . |
| 67 | S&F fancy design SS garde 304 street LED bollard having minimum weight of 8.4 Kg, diameter of 75 mm length of 1.00m at top and bottom diameter of 180mm using 100 mm polycarbonate glass milky white with 12 watts LED module light of philips/fulham driverhaving adequates number of connectors and one power supply kitas per manufacture requirementand provide bothsidehook for fixing chain linknecessary provision for fixing on road all as specified and as directed by Engr-in-Charge. Note- Item includes connection to main electric supply from near by electric sources. |
| 68 | M&L brick work with sub class \"B\" bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 of brick work including all quoins, arches, Pillars etc. but excluding ashlar facings built in cement mortar all as specified & directed. |
| 69 | M&L Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete masonry walls, finished surfaces even and fair without using extra cement all as specified and directed. |
| 70 | M&L coloured, digital glossy/Matt outdoor ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm/600x300x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4all as specified and directed by Engineer-in-Charge |
| 71 | M&L RCC 1:2:4 type B-1 (Nominal mix ) (using 20mm graded crushed stone aggregate) as in precast cover slab prforated fixed in position, tie between two brick wallsand all other similar worksset in CM 1:4 including necessary form work all as specified and directed |
| 72 | Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 25 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) (Note: thickness shall be measured excluding plaster) |
| 73 | Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed.. (All loose unsound and cracked concrete shall be removed out side MD land)(Note: thickness shall be measured excluding plaster) |
| 74 | Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 60 mm average depth including saw-cutting of all edges making square shoulders of the cavities including all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land)(Note: thickness shall be measured excluding plaster) |
| 75 | Cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dryand Applying two coats of epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/ Krishna Conchem) as approved by the Engineer-in-Charge for old and new reinforcement any dia all as specified and as directed. (Note : - Length of reinforcement bars cleaned of rust all around shall be measured for payment.) |
| 76 | Providing and placing in position micro-concrete, grade M40, which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion, obtained from Fosroc / SIKA / BASF/ Dr Fixit, thickness of section upto 75 mm all as specified and as directed by the Engineer in charge (Payment under this item shall bemade only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) |
| 77 | Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water and removing debris outside MD land (from ground floor to fourth storeys bldgs)including use of scaffoldings all as specified and directed. |
| 78 | M&L 15mmthick Ready Mix Plaster in single layer of make / brand - ACC\"s Accoplast / CK Birla\"s Aerocon / Speed Dry Mix\"s Ecoplaster / Magic Plast / Build well, mixed withliquid water proofing compound on other than fair faces of brick wall or concrete surfaces, including use of scaffoldingany story all as specified and directed.Note :-Liquid water proofing compound will be measured and paid seperately as supply only. |
| 79 | Providing & applying anti algalwater-based Elastomeric exterior wall finish on old as well as newly plastered surface including surface preparation, applying suitable wall Primer and application of two coats of paint by brush all as specified and directed.Note : Height of Bldg Up to fourth floor. |
| 80 | M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height as specified and directed. |
| 81 | S&F GI tubing 50 mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. |
| 82 | S&F GI tubing 25 mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. |
| 83 | S&F GI tubing 40mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed. |
| 84 | S&F 40mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed. |
| 85 | S&F 25mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed. |
| 86 | S&F 50mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed. |
| 87 | S&FPressure release valves model W3-B, 25mm connection brass material grade SS 316-.4mm for fixing in any height all as specified and directed by the Engg-in-Charge. |
| 88 | S&F 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes andfixed to walls all as specified and directed. Note : The above item inculde upto any height of builidng and including necessary scafolding |
| 89 | S&F 75mm dia PVC (SWR) bends without access doors any radius all as specified and directed. |
| 90 | Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and directed. |
| 91 | Demolition of Cement concrete (reinforced) of any description and in any position not otherwise specifically provided all as specified and directed. |
| 92 | M&L 75 mm PCC 1:3:6 type C-2(using 40 mm graded crushed stone aggregate) as in plinth protection, flooring/subbase including necessaryshuttering all as specified and directed. |
| 93 | M&L RCC 1:1.5:3 (using 20 mm graded crushed stone aggregate) in Beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deck slabs etc. or in similar articles upto 5th floor level all as specified and directed. |
| 94 | S&F hot rolled medium and high tensile structural steel of grade E- 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, flat iron or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) all as specified and directed. |
| 95 | S&F structural steel work in tubular/square tube trusses including special shaped washer,gusset/bearing plate using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 all as specified and directed. |
| 96 | S&F rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde- E- 250) quality A all as specified and directed. |
| 97 | Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface all as specified and directed |
| 98 | M&L PCC 1:3:6, type C1 (using 20mm graded crushed stone aggregate) as in embedding of post all as specified and directed. |
| 99 | M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare RP or Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coatingcold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications over and including padding of cement concrete Type B1,1:2:4 (20 mm graded stone aggregate) 40mm average thick on RCC roof surfaces and all other similar works all as specified and directed (DR Fixit New coat or any equivalent). |
| 100 | M&L for preparation of new steel surfaces of any description over10 cm width orgirth, not otherwisedescribedand applying two coats ofsyntheticenamel paint over a coat of red oxideall as specified and directed. |
| 101 | M&L for disconnecting existing tanks exc 1000 & n.exc 2000 ltr , setting aside( or lowering if reqd) for repair cleaning etc and hoisting if reqd reconnecting and refixing in position all as specified and directed. |
| 102 | S&F 4000 ltrs rotational moulded PVC water tank 3 layer in position at any location on top of the building including float valve suitable up to 50mm bore all as specified & directed by Engg-in-Charge. |
| 103 | S&F 5000 ltrs rotational moulded PVC water tank 3 layer in position at any location on top of the building including float valve suitable up to 50mm bore all as specified & directed by Engg-in-Charge. |
| 104 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling |
| 105 | M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light point controlled by one switch.Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & IIINote (All chases will be cut by chase cutter only) |
| 106 | All as per Srl item No.106 here in before but for socket outlet point 5 Amp on same board. |
| 107 | All as per Srl item No.106 here in before but for socket outletpoint 5 Amp on Independent board. |
| 108 | All as per Srl item No.106 here in before but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. |
| 109 | S&F modular switch 1 way 6A module 230/250 volt , AC supply,ISI Marked, with white cover plate with frame all as specified and directed. |
| 110 | S&F modular switch 1 way 16A module 230/250 volt, AC supply,ISI Marked, with white cover plate with frame all as specified and directed. |
| 111 | S&F modular sockets 6A, 2/3 pin combined 2 module 230/250 Volts,50 Hz, AC supply, ISI Marked, with cover plate all as specified and directed. |
| 112 | S&f modular sockets 6A/16A, 2/3 pin combined 2 module, 230/250 Volts,50 Hz, AC supply, ISI Marked, with white cover plate with frame all as specified and directed. |
| 113 | S&F in repairs Modular type AC Box, 4 Module with Socket and 25 Amp SP mini MCB in plastic box enclosure along with cover plate and top complete all as specified and directed. |
| 114 | S&F modular Fan step/ electronic regulator, 120W - 2 module A module 230/250 volt , AC supply,ISI Marked, with cover plate all as specified and directed. |
| 115 | S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed. |
| 116 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete pre wired fixed to wallwith 2 nos PVC block of suitable size all spcifided and directed. |
| 117 | S&F LEDWall bracket decorative fancy light fitting warm white /white type with lamp 12 Watt with necessary connection all as specified and directed. |
| 118 | S&F LED down lighter 15 watt warm white fancy light fitting warm white /white type with lamp12 Watt with necessary connection all as specified and directed. |
| 119 | S&F Exhaust fan 230 volts, 250mm, plastic body includingmaking all electric connection all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall all as specified and directed. |
| 120 | S&F Ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDCmaking all electric connection. huck and suitable size rod for hanging ceilingfan all as specified and directed |
| 121 | S&F in repairs LED security Buildinglight LED 45 Watt, pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of lightall as specified and directed. |
| 122 | S&F in repairs MCB Distribution board, 240 volts, single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed. |
| 123 | S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" series all as specified and directed including taking down old one. |
| 124 | S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"s all as specified and directed including taking down old one. |
| 125 | S&F in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting all as specified and directed.(Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule .Note : Copper thimble shall be used for connection of cable. |
| 126 | S&F in repairs MCCB TPN, 240 Volts, 63 to 100Amps, 10 kA rupturing capacity 415 Volts all as specified and directed including taking down old one. |
| 127 | M&L in repairs Sub main wiring with two run of 6 sq mm stranded copper conductor PVC unseathed FRLSH wire along with 6 sq mm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB including taking down old Unsv submain with all associated fixtures all as specified & directed by engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduite shall be measured as one length. |
| 128 | M&Lin repairs Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia casing cappingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of6 sqmm cable and one run of PVC conduitshall be measured as one RM. |
| 129 | M&L Sub main wiring with two run of single core 1.5 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia casing cappingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of1.5 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring all as specified and directed. Note: (i) Two runs of 1.5 sqmm and one run of1.5 sqmm cable and one run of PVC conduitshall be measured as one RM. |