| 1 | Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage. |
| 2 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 18 module suitble for Mylinc series of Legrand including white plates with frame upto 18 module of make suitable for Mylinc Series )for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed.Note :1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg3.All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc |
| 3 | One light point/Fan point/bell point controlled by switch5 Amp single pole one way |
| 4 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 5 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 6 | One light point controlled by switch5 Amp single pole two way |
| 7 | All as per Item No 2 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 8 | M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washerfor fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note :1. Proper colour coding shall be adopted for wiring (For Phase-Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2.All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc |
| 9 | One light point controlled by switch5 Amp single pole one way |
| 10 | One fan point controlled by switch5 Amp single pole one way |
| 11 | One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch |
| 12 | One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board |
| 13 | All as per Item No 8 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board |
| 14 | S&F in replacement bell ding dong elelctric 230V ACsingle pole etc complete all as specified and directedby Engineer-in-Charge |
| 15 | S&F in replacement Modular Switch, 6 Amp, one way, one Module as per existing.etc complete all as specified and directedby Engineer-in-Charge |
| 16 | S&F in replacement Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directedby Engineer-in-Charge |
| 17 | S&F in replacement Modular Switch, 16 Amp, one way, one Module as per existing. etc complete all as specified and directedby Engineer-in-Charge |
| 18 | S&F in replacement Modular Socket Outlet6 Amp,3 pin, combined two module etc as per existing complete all as specified and directedby Engineer-in-Charge. |
| 19 | S&F in replacement Modular Socket Outlet6 Amp / 16 Amp - 2/3 pin combined two moduleas per existing etc complete all as specified and directedby Engineer-in-Charge |
| 20 | S&F in replacement Modular Bell push, 6 Amp, one module etc complete all as specified and directedby Engineer-in-Charge |
| 21 | S&F in replacement ModularFan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directedby Engineer-in-Charge |
| 22 | S&F in replacement switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directedby Engineer-in-Charge |
| 23 | S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directedby Engineer-in-Charge. |
| 24 | S&F in replacement Socket outlet 3 Pin ,6 A etc complete all as specified and directedby Engineer-in-Charge |
| 25 | S&F in replacement lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directedby Engineer-in-Charge |
| 26 | S&F in replacement ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directedby Engineer-in-Charge |
| 27 | Taking out old PVC/Wooden/metal switch board ,wire connectionfrom the wall and fix new PVC Cutting sheet board box including connecting wire suitable for fixing switch/Socket/fan regulater of following sizes .(Note.Damaged Switch / Socket / regulator will be measured and paid Sepereately) |
| 28 | 100 x100x 50 mm |
| 29 | 100 x175x 50 mm |
| 30 | 200 x150x 50 mm |
| 31 | 250 x200x 50 mm |
| 32 | 350 x300x 50 mm |
| 33 | S & F in replacement double doorSheet metal enclosures factory made DBs4 way TPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs,etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 34 | S & F in replacement double doorSheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42,Concealed in wall suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 35 | S & F in replacement double doorSheet metal enclosures factory made DBs4 way SPN, 240 volts ,Concealed in wall protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. |
| 36 | S&F in replacement MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 10KA, \"B\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 37 | S&F in replacement MCBs, TPN, AC, 415 volts of 63 Amps capacity 10 KA, \"B\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge . |
| 38 | S&F in replacement MCBs, SPN, AC, 240 volts of 40 Amps capacity 10 KA, \"C\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 39 | S&F in replacement MCBs, SPN, AC, 240 volts of 63 Amps capacity 10 KA, \"C\" series and making connections with suitable size of copper lugs etc complete all as specified and directedby Engineer-in-Charge |
| 40 | S&F in replacement square profile LED lighting fixture , environmental friendly, energy efficient ready to use packAluminium housing LED Tube light fitiing 40 Watt with LED light source 6500 K,input voltage 140V-270V with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cableof size 0.5 Sqmm withcompletewith all accessories etc complete all as specified and directedby Engineer-in-Charge Make: Smart bright batten or equvalent in Make |
| 41 | S&F in replacement square profile LED lighting fixture with extruded Aluminium housing, environmental friendly, energy efficient ready to use packLED Tube light fitiing 12 Watt with LED light source 6500 K,input voltage 140V-270Vwith uniform light output, with all accessories including its connection with 2 core seathed cableof size 0.5 Sqmm withetc complete all as specified and directed by Engineer-in-Charge.Make: Smart bright batten or equvalent in Make . |
| 42 | S&F in replacement 36 Watt recessMounting LED Panel 2X2 environmental friendly, new generation,aesthetically designed, ultra modern Surfacemounting luminaire with high brightness SMD LEDs as light source,energy efficient>100 lumens/watt suitable for armstrong/Grid ceiling, complete with separate electronic driver ceiling light 36 Watt with and including connecting up with & including twin core, twisted, flexible copper conductor cable of suitable size 230 Volt, 50 HZ etc complete all as specified and directedby Engineer-in-Charge |
| 43 | S&F in replacement 20 Watt LED Panel 1X1 environmental friendly, new generation,aesthetically designed, flat panel for surface mounting which provides soft-light and glare free symmetrical illumination, complete with separate electronic driver ceiling light 20 W,CRI>80,operating voltage 140 V to 270 V,CCT 6500K including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230 Volt, 50 HZ etc complete all as specified and directedby Engineer-in-Charge |
| 44 | S&F100 Watt high bay light fittings Epoxy powder coated pressure die cast aluminium housing in grey finish with elegantly designed heat sink for efficient thermal management,strdiness & excellent corrosion resistent,m16 cable gland provided at cable entery ,the fixture epoxy coated,high efficiency long life LED lumen efficiency of >140 lm/W,power factor>.95 with view angle 120 degreefor better uniformity,tempered protective toughned glass ,thermal shock and impact resistence IK 07 fixed to the housing,built in potted IP67 electronic LED driver with APFC,lower THD,phase to phase(440 V withstand ) Open circuit protection,over voltage protection,surge voltage protection,suspended by means of heavy duty nickel plated,eye volt provided with fixture complete all as directed by Engineer in Charge |
| 45 | S&F in replacement environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head Back-lit 10 W LED ,IP65 ,IK 08 rated product luminaire comprising of high brightness LEDs complete with all accessories prewired and includingconnecting up with & including twin core twisted flexible copper conductor cable of suitable size etc complete all as specified and directedby Engineer-in-Charge |
| 46 | Supply & fix in replacemnt industrial type switch socket for Geysers with 20 Amp MCB etc complete all as specified and directedby Engineer-in-Charge |
| 47 | S&F sub main wiring with two single core PVCinsulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn throughand including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit. |
| 48 | S&F sub main wiring with two single core PVCinsulated,unsheathed, FRLS stranded copper conductor cable 1.5 Sqmm with 1.5 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn throughand including PVC casing caping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 1.5 Sqmm cable i.e for one run for phase, one run for neutral with one run of 1.5 Sqmm cable for earth and one run of PVC casing caping shall be measured as one unit |
| 49 | S&F sub main wiring with two single core PVCinsulated,unsheathed, FRLSH stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn throughand including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directedby Engineer-in-Charge Note :1. Proper colour coding must be utilize for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black)2. Two run of 6 sq.mm cable i.e for one run for phase, one run for neutral with one run of 6 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit |
| 50 | S&F150 Watt high bay light fittings Epoxy powder coated pressure die cast aluminium housing in grey finish with elegantly designed heat sink for efficient thermal management,strdiness & excellent corrosion resistent,m16 cable gland provided at cable entery ,the fixture epoxy coated,high efficiency long life LED lumen efficiency of >140 lm/W with view angle 120 degreefor better uniformity,tempered protective toughned glass ,thermal shock and impact resistence IK 07 fixed to the housing,built in potted IP67 electronic LED driver with APFC,lower THD,phase to phase(440 V withstand ) Open circuit protection,over voltage protection,surge voltage protection,suspended by means of heavy duty nickel plated,eye volt provided with fixture complete all as directed by Engineer in Charge |
| 51 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts& washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precostRCC(1:2:4)mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC,both way, lifting arrangement complete including all necessaryearth work etc complete all as specified and directedby Engineer-in-Charge |
| 52 | Taking out/downand opening of existing ceiling fans 1200 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling andafter servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed. |
| 53 | Supply & fixinginreplacementBall bearing No 6201 etc complete all as specified and directed by Engineer-in-Charge |
| 54 | Supply & fixinginreplacementBall bearing No 6202 etc complete all as specified and directed by Engineer-in-Charge |
| 55 | M&L for preperation of ceiling fans 1200 mm sweep, of any make by cleaning of metal surfacesincluding painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing MES No with black synthetic enamel paint etc complete all as specified anddirected by Engineer-in-Charge |
| 56 | Supply & fixinginreplacementcapacitor 2.5/3 mfd, 250 volts , ACetc complete all as specified and directed by Engineer-in-ChargeMake:- Crompton /Bajaj /EPCOS/Havells |
| 57 | Supply and fixinginreplacementelement 2 KW, rubber gasket type with & including rubber gasketcompletesuitable for 25 Ltrs Geysers of any Make as installed at site etc complete all as specified and directed by Engineer-in-Charge . |
| 58 | Supply and fixinginreplacementPVC insulated cable 40/0.0076,3 core copper conductor cable for connection fron geyser to top plug etc complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directedby Engineer-in-Charge Make -Bajaj/Crompton/Phillips |