| 1 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed. |
| 2 | Excavation in trenches, not exceeding 1.5 mtr wide andexceeding 1.5 but not exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and getting out in hard/dense soil, complete all as specified and directed. |
| 3 | Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed. |
| 4 | Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. |
| 5 | PCC 1:3:6 (nominal mix) type C-1(using 20mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. |
| 6 | PCC 1:2:4 (nominal mix) type B-1(using 20mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed. |
| 7 | Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cms thick, complete all as specified and directed Note: Punned thickness shall be measured. |
| 8 | Supplying and laying reinforced precast concrete cable cover, class LV, type 1 , flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 9 | Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 16 sqmm 4 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988complete all as specified and as directed. |
| 10 | Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 25 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988complete all as specified and as directed. |
| 11 | Supply, jointing, fixing or passing through pipe , trenches or ducts, commissioning and testing XLPE insulated screened and PVC sheathed armoured electric power LT cable heavy duty with aluminium conductor nominal cross sectional area 50 sqmm 3.5 core for working voltage upto including 1100 volts conforming to IS-7098 (Part-I) 1988complete all as specified and as directed. |
| 12 | Cutting/ grooving on plinth/wall/ verandah in any condition for laying of cable through pipe and making good the disturbed surface by using cement concrete 1:2:4 type B-0, using 12.50 graded crushed stone aggregate as required complete all as directed. |
| 13 | SMC cable junction box of size 250x200x100mm suitable for street light/PTL, square type , weather proof , IP-54 including fixing of 10Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with twin core 2.5 Sqmm PVC Cable laying through PVC conduit from junction box to street light fitting complete all as specified and directed.Make : Sintex Cat Part No. GSJB-2520 or its equivalent approved make.Note : Twin Core PVC Cable 2.5 Sqmm from Junction box to Street Light fitting shall be measured under respective item of BOQ. |
| 14 | Twincore PVC insulated multistranded 1100 volt grade copper conductor cable of size 2.5 sqmm with complete cable connection on street light fitting to looping box complete all as specified and directed. |
| 15 | Mild steel galvanised iron tubing light grade for cable protection as in road crossing, along poles, walls, floors, drain of 40mm size fixed with MS clamps, nuts and bolts required complete all as specified and directed. |
| 16 | Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ. |
| 17 | Streel Light Digital timer panel 3 phase, Max load capacity 6 kw, Contactor rating 32 Amp TP , MCB rating 40 Amps TPN with 24 hours working digital timer switch outdoor type panel with canopy and locking arrangemant of panel with all incoming and outgoing cable connection complete including testing , complete all as specified. Make: Havells Cat Part No :IHXTS03060 oror its equivalent in Appx |
| 18 | High performance IP66, 90W LED Street Light fixture with New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07. complete all as specified and directed.Make: Havells Cat Part No : ENDURASUNDOWNSL90WLED765PASYBOTGor Bajaj Cat Part No - NEXO 108L WH PO PC SD or Orient Cat Part No :LSFS-090-C or its equivalent in Appx |
| 19 | Street light bracket made out of GI pipe 40mm dia medium grade GI Pipe minimum 1.5 Mtr long including fixing with 02 Nos MS clamps made out of flat iron of size 30mm x5 mm with nut bolts and washer incl painting work complete all as specified and directed |
| 20 | Factory made outdoor type factory made bus bar chamber of size 0.75 x 0.45 x 0.40 meter depth made out of CRCA sheet 3.15 mm thick with 4 Nos aluminium busbars of capacity 200 Amps, with colour code supported on incoming and outgoing under ground cables with LED R, Y, B indicator lamp, panel having angle iron frame made of 40 x 40 x 6 mm angle iron and 50 cms long legs embedded upto 20 cms in PCC & 30 cms clear above ground complete including painting with two coat of powder coatedpaint over a coat of red oxide primer on exterior and interior faces, errection of Bus Bar chamber duly grouted with PCC including earth work complete all as specified and directed byEngineer-in-Charge. |
| 21 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |