| 1 | Excavation in trenches in Hard/dense soil not exc 1.5m wide & not exc 1.5 deep and getting out inhard/dense soil complete all as specified and directed. |
| 2 | Excavation in trenches in soft disintegrated rock not exc 1.5m wide & not exceedingm1.5 m deep and getting out for laying of pipe complete all as specified and directed. |
| 3 | Removing excavated material outside MDn.exc 50m and depositing where directed at a level in n.exc 1.5m above the starting point in soil complete all as specified and directed. |
| 4 | Returning fillingin including spreading , levelling watering and wellramming in layers not exceeding 25cm complete all as specified and directed. |
| 5 | Supply, laying, connecting, jointing and testing Centrifugally cast ( Spun ) Ductile iron Pressure pipe ISI Marked confirming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of size 80mm bore with socket spigot ends, suitable for \"Push on Joints ( Tyton Joint )\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \"Push on Joint\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete, including taking up old80 mm bore cast iron water mains ( including all fittings) with spigot and socket ends/ Tyton joints and lead joints includingburning out joints and recovering lead complete all as specified and directed. |
| 6 | Supply, laying, connecting, jointing and testing Centrifugally cast ( Spun ) Ductile iron Pressure pipe ISI Marked confirming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of size 100mm bore with socket spigot ends, suitable for \"Push on Joints ( Tyton Joint )\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \"Push on Joint\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete, including taking up old100 mm bore cast iron water mains ( including all fittings) with spigot and socket ends/ Tyton joints and lead joints includingburning out joints and recovering lead complete all as specified and directed. |
| 7 | Supply, laying, connecting, jointing and testing Centrifugally cast ( Spun ) Ductile iron Pressure pipe ISI Marked confirming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of size 150mm bore with socket spigot ends, suitable for \"Push on Joints ( Tyton Joint )\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \"Push on Joint\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete, including taking up old150 mm bore cast iron water mains ( including all fittings) with spigot and socket ends/ Tyton joints and lead joints includingburning out joints and recovering lead complete all as specified and directed. |
| 8 | Supply, laying, connecting, jointing and testing Centrifugally cast ( Spun ) Ductile iron Pressure pipe ISI Marked confirming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of size 300mm bore with socket spigot ends, suitable for \"Push on Joints ( Tyton Joint )\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, ClassK-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \"Push on Joint\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete, including taking up old300 mm bore cast iron water mains ( including all fittings) with spigot and socket ends/ Tyton joints and lead joints includingburning out joints and recovering lead complete all as specified and directed. |
| 9 | S&F cast iron bends (any radius and angle) tappers any type (straight, bend, increasing, decreasing or double socket) Tee, piecessingle branch, “ Y” junction, double branch, cross ( all socket or socket spigot) collars, caps, caps & plugs of the sizeupto 450mm diacomplete all as specified and directed. |
| 10 | Supply and laying, connecting, jointingandtesting of Ductile iron pipe fittings ( Specials ) heavy duty for any type ( flanged / socketed ) pipes such as bends ( any type radius, and angle ), tapers, any type straight bend, increasing, decreasing or double socket etc. Tee pieces, ring branch, Y junction, double branch, cross ( all socket or socket and spigot ), collars, caps and plugs, adapters etc. of any size radius and length conforming to IS 9523 / 2000 specifications with external bitumen coating and internal cement mortor lining and metallic zinc coating of size upto450mm bore complete all as specified and directed. |
| 11 | M&L for cutting of bituminous Road/floor/plinth protection for laying pipe not exceeding 1.5m width and not exceeding 1.5 depth, including refiling with excavated material and watering well ramming/compacting and making good top surface with PCC 1:2:4 100 mm thicktype B-0 using 12.5 graded stone aggregate complete all as specified and directred. |
| 12 | M&L for PCC 1:3:6 type C 2 using 40 mm graded stone aggregate as in filling mass concrete and making good distrubed surface all as specified and directed. |
| 13 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 80 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 14 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 100 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 15 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 150 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 16 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 200 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 17 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 250 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 18 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 300 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 19 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 350 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 20 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 400 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |
| 21 | Repairs to leakeage/repairs and water supply break down by using JCB/Manual arrangesufficient manpower to arrest leakeage/break down including taking down and relaying of 450 mm dia bore complete all as specified and directed. Note: Earth work/PCC/CI/DI specials shall be measurerd and paid separately |