| 1 | M&L for Day to day checking and maintenance of street light, perimeter light and high mast light including accessories, LED lights fitting on wall or pole or high mast and of any other locations to find out defects including dismantling of defective parts or taking down the fitting if, necessary, cleaning the bowl/ perflex cover and making the fitting in 100% serviceable condition including rectification of fault of over head lines and under ground cables if, any complete all as specified and as directed. |
| 2 | Note: (i) The Contractor shall deploy minimum 01 Elect and 01 Helper except sunday & holidays for the purpose from 0900 hrs to 1700 Hrs daily. (ii) All T&P/Safety items shall be provided by the contractor at his own cost.(iii) The Contractor shall rectify the complaint within 24 Hours otherwise penal charge will be imposed at the rate of @ Rs. 200/ per complaint/ per hour. (iv) Quoted rates shall include arrangement of bucket crane of high height or any other means required to rectify the compliants at the height of 11/18 metre or above. Safety of the tradesmen employed shall be the resposibility of the contractor. (v) Defective parts such as LED driver, service wire, cable joints shall be measured and paid under relevent item separately. However cost of replacement of minor parts such as nut, bolt, washer etc shall be inclusive in quoted rates. |
| 3 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for laying cables and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Returning filling in excavated soil including spreading levelling and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 5 | Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed. |
| 6 | Taking down existing old unserviceable UG LT cable upto size 35 Sqmm 3.5/2 core keeping aside for reuse/removal from trenches/wall/pole complete all as specified and directed. |
| 7 | Supply, laying, connecting and testing of XLPE insulated PVC sheathed armoured cable 4 core x 10 Sqmm, 1100 volts grade heavy duty wth standard aluminium conductor including aluminium lugs/thimbles of suitable size and gland packing complete all as specified and directed. Note: Earth work, DWC pipe, GI pipe will be measured and paid separately. |
| 8 | All as per item Srl No. 6 but of size 4 Core x 16 Sqmm |
| 9 | All as per item Srl No. 6 but of size 4 Core x 25 Sqmm |
| 10 | Supply and laying HDPE DWC pipe size outer dia 50 mm, inner dia 38 mm for LT cable protection including sockets, bends etc complete all as specified and directed. |
| 11 | Material and labour for GI tubing light grade size 40mm bore, laid in trenches/fixed to poles, walls etc as protection to cable all as specified and directed. |
| 12 | Supply and fixing LED street light fitting 70 Watt, 230 Volts AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specifed and directed. |
| 13 | All as per item Srl No. 11 but LED street light fitting 90 Watt |
| 14 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specifed and directed. |
| 15 | All as per item Srl No. 13 but LED Flood light fitting 210 Watt |
| 16 | Supply & fixing in repair LED driver suitable for LED street light/flood light fitting as per site requirement for capacity upto 90 watt, complete all as specified and directed. |
| 17 | Supply & fixing in repair LED driver suitable for LED street light/flood light fitting as per site requirement for capacity from above 90 to 200 watt, complete all as specified and directed. |
| 18 | Supply & fixing in repair surge protection devices for outdoor LED street light/flood light fitting upto rated power of 200 watt as per site requiremnts complete all as specified and directed. |
| 19 | Material and labour for dismantling carefully high mast pole 12 to 15 mtrs height, shifting within 1 KM radius and erecting & refixing the same alongwith connected accessories to new location and making fully servicable comlete all as specified and directed. Note: (a) All T&P/Safety items shall be provided by the contractor at his own cost. (b) Quoted rate shall include arrangement of bucket crane/hydra required height or any other means required to shifting of high mast light with in 1 KM radius. Safety of the tradesmen employed shall be the resposibility of the contractor. (c) Defective parts such as LED driver, service wire, cable joints shall be measured and paid under relevent item separately.(d) Earth work and PCC work along with TMT bar for making foundation and coping shall be paid and measured seperatly under relevent items. |
| 20 | Material and labour mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 21 | All as per item Srl No. 19 above but 6 to 8 mm size |
| 22 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sqmm x 2 core nominal cross section in service connections complete all as specified and directed. |
| 23 | Supply & fixing in repair of PVC insulated flat twin core 2.5 Sqmm unsheathed aluminium conductor complete all as specified and directed. |
| 24 | Supply and fix in repair PVC conduit heavy duty of size 20 mm dia on pole/wall including passing of existing/new service wire through conduit from junction box to security light fitting complete all as specified and directed. |
| 25 | Material and labour for making two Nos of holes of required dia at bottom and top of existing steel tubular pole by necessary drilling/welding for passing of service cable including passing/ reconnecting of existing street light fitting to junction box complete all as specified and directed. |
| 26 | Supply and fixing PVC junction box IP-66 with metric knockouts for cable entry up to 25 Sqmm, size 250x200x110 mm with terminals including MCB SP 6A and fixed on pole with MS clamps size 25 x 4mm complete all as specified and directed. |
| 27 | Supply and fixing in repair MCB SPN 5 to 32 Amp compete all as specified and directed. |
| 28 | Supply and fix in repair MCB TPN/FP 40 Amp complete all as specified and directed. |
| 29 | Material and labour for PCC 1:3:6 type C-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement complete all as specified and directed. |
| 30 | Material and labour for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete complete all as specified and as directed. |
| 31 | Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch \"A\" while deriving the Contract Sum for Acceptance. |