| 1 | Air conditioner window/ split typeM&L for taking out u/s air conditioner window/ split type in capacity 1.5 TR and 2 TRfor replacing to u/s spare parts /re-painting / carrying out neccessary repairing works/ shifting location/ gas re-filling etcin any make /modelall as site with connecting accessories from existing location after removing of all connections safely and transportation from site to work shop and back (if required)at same after repairing work complete all specified andas directed. Note :- (i) Connecting accessories will be taken in safe custody by contractor for re-using at same.(ii)All spare parts shall be measured and paid separatelyunder relevant items. |
| 2 | M&Lfor overhauling, dusting, cleaning by compressed air, washing using causting soda mixed with waterafter scraping to old paint coatto bepreparing the surface for re-painting to air condioner in any type /make/ model/ cap/ etc all as site using heat resistive/ synthetic enamel paintby paint spray gunin two coats over one coat of red oxide primer and indication markingby diffirent colour in standard size of letter complete all specified and as directed .Note :- (i)Paint colourshall be approved by Engr-in-charge. (ii) All spare partsrequired to servicing shall be measured and paid separetly under relevant item. |
| 3 | Supply and re- filling/ charging of refrigerant gas of R-134A,R-32, R-410A, R-22in original towindow or split type air conditioner upto 2 TR capacity with speicific pressure grade complete all as specified and asdirected. Note : Grade of refrigerant shall be supplied as permodel /make requirement in original. |
| 4 | Labourfor re-fixing/installation/ connecting/ testing and commissioning of repairedair conditioner under above itemin original postion all as same as per exsiting incl making electric / air connections withother site requiredwork for serviceablitycomplete all as specified and asdirected. |
| 5 | M&L for making hole for fixing of window air condioner for any type/ make/ model / capacity etc. after cuttingwindow\"s net made out by MS bar or strip / brick wall etcincl all type all required insulating/ fixing materials such as thermocal/ piece of plywood etc including good disturb surface complete all as specifiedand directed. |
| 6 | Supply and fixing in replacement ofrotary DC compressor unit for invertor window type cap upto 1.5 TR 230 V, Single Phase as required in origional manufactures complete all as specified and directed. Note :-(i) All spares shall be hold original manufacture tag with cat no. (ii)Spare will be supplied in originalMake\"as per OEM |
| 7 | All as above item No 06 butrotary DCcompressor unit for invertorsplit type cap upto 1.5 TR.230 V, Single Phase Complete all as specified and directed. |
| 8 | All as above item No06 but reciprocating / rotaryAC compressor unit for window type cap upto 2.0 TR.230 V, Single Phase Complete all as specified and directed. |
| 9 | All as above item No 06 but reciprocating / rotaryAC compressor unit forsplit type cap upto2.0 TR.230 V, Single Phase Complete all as specified and directed. |
| 10 | All as above item No 06but Starting/Running Capatior for Existing model of split/ window AC |
| 11 | All as above item No 06 but condenser unit for window type |
| 12 | All as above item No 06 butindoor unit blowerfan motor for split type cap 1.5 TR. |
| 13 | All as above item No 06 butout door unit fan motor for split type cap 1.5 TR |
| 14 | All as above item No 06 butindoor unit fan blowermotor for split type cap 2 TR. |
| 15 | All as above item No 06 butout door unit fan motor for split type cap 2 TR |
| 16 | All as above item No 06 but blowerfan motor for window AC cap 1.5/2 TR |
| 17 | All as above item No 06but PCB outdoorfor split type AC cap 1.5/ 2 TR. as per site requirement. |
| 18 | All as above item No 06 but PCB indoorfor split type AC cap 1.5/ 2 TRwith remote Control. |
| 19 | All as above item No 06 but PCBfor windowtype AC cap 1.5/ 2 TR. |
| 20 | All as above item No 06but DCstapping motor. |
| 21 | All as above item No 06 but thermostate assembly. |
| 22 | All as above item No 06 but indoor condensestion unit for split type 1.5 TRAC . |
| 23 | All as above item No 06 but outdoor condensestion unit for split type 1.5 TR AC. |
| 24 | All as above item No 06 but indoor condensestion unit for split type 2 TR AC. |
| 25 | All as above item No 06 but outdoor condensestion unit for split type 2 TR AC. |
| 26 | All as above item No 06 but relay for AC for window /split type cap 1.5/ 2 TR. |
| 27 | All as above item No 06 but Selector switch |
| 28 | All as above item No 06 but front panel grill. |
| 29 | All as above item No 06 but Remote control suitable for as site unit. |
| 30 | All as above item No 06 but automatic sensor card. |
| 31 | All as above item No 06 Capacitor for Fan motor. |
| 32 | S&F in replacement of Air filter for split/ window type AC. |
| 33 | S&F in replacement of swing motor for indoor unit of split/window AC complete all as specified and directed. |
| 34 | Flushing and leak testing of complete system with Nitrogen gas and topping up compressor oil complete all as specified and directed. |
| 35 | S&F in replacement for blades ofmodel of existing/ suitable model of window/ splite type (outdoor Unit) of capacity up to 2 TRcomplete all as specified and directed. |
| 36 | Supply only out door unit of air cooled split unit Air conditioners electric driven single Phase of capacity of 1.5TR with minimum 3 star ratingEER 3.2 , including iron clamp for mounting of outdoor unit complete all as specified and directed. |
| 37 | Supply only indoor wall mounting unit of air cooled split unit Air conditioners electric driven single Phase of capacity of 1.5TR with minimum 3 star ratingEER 3.2 complete all as specified and directed. |
| 38 | M&L for servicing,oiling, greasing, cleaning, dusting ,overhauling etc all as site requirementfor air conditioner in all make/type/ model /cap upto 2 TR etcfor making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as sitecomplete all as specified and directed. |
| 39 | M&L for replacing to rusted body portion/partof air conditioner in all make/ model / capacity etc as siteusing MS sheets minium 18 gauge for body and angle for frame work including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as specified and directed. |
| 40 | Water cooler/ refiregator and Deep- freezer :- Labourfor taking out u/s water cooler/ refrigerator and deep- freezerof any make/ model/ capacity etc for replacing to u/s spares /re-painting /servicing/ carrying out neccessary repairing works/ shifting location/ gas re-filling etcin any type/ cap/ make /modelall as site with connecting accessories from existing location after removing all connections safely and transportation from site to work shop and back (if required)at same after repairing work complete all as specified and directed.Note :- (i) Connecting accessories will be taken in safy custody by contractor for re-using at same.(ii) All spaires shall be measured and paid against respective items . |
| 41 | M&L for servicing,oiling, greasing, cleaning, dusting overhauling to water cooler/refrigerator and deep- freezerin any make/ model/ capacity etc complete all as site requirement works forin all make/type/ model /cap etcfor making serviceable with satisfactions including disconneting, removing, re-fixing ,and re-connecting all as same at sitecomplete all as specified and directed. |
| 42 | M&L for replacing to rusted body portion/partof refrigerator/ water cooler/ deep- freezeretcin all make/ model / capacity etc as siteusing MS sheets minium 18 gauge for body and angle for frame work and base unit including jointing welding cutting etc all works finishing/ painting to matching with existing surface complete all as specified and directed. |
| 43 | Supply and fixing in replacement of compressor unit for 40 to 80 ltr storage capacity suitablefor refrigerator/ water cooler/deep- freezer in any capacity / make/ model/ type etcas site in origional manufactures complete all as specified anddirected.Note :-(i) All spares shall be hold original manufacture tag with cat no.(ii)Spare will be suitable for all capacity and MakeLG / Voltas/ Blue star/ Usha/ Vidiocon/ Usha/ Sumsang / Annapurna / whirlpool/ Gojrej/ Danfoss / Tecumseh etc as site. |
| 44 | All as above item No 43 but compressor unit for 80 to 150ltr storage capacity. |
| 45 | All as above item No 43 but compressor unit for 165 to 250 ltrs capacity |
| 46 | All as above item No43 but compressor unit for 250 to 405ltr capacity. |
| 47 | All as above item No 43 but evaporator assembly single/ double door refrigerator capacity upto 250 Ltr. Make - as per sample. |
| 48 | All as above item No43 but evaporator assembly single/ double door refrigerator capacity 280 to 320 Ltr .Make - as per sample. |
| 49 | All as above item No 43 but evaporator assembly water cooler/ deep- freezer capacity upto 205 Ltrs |
| 50 | All as above item No43but evaporator assembly water cooler/ deep- freezer capacity220 to 405 Ltrs |
| 51 | All as above item No 43 but Duct assembly double door. |
| 52 | All as above item No 43 but dryer for refrigerator. |
| 53 | All as above item No 43 but motor DC single/ double door |
| 54 | All as above item No 43 but power cord single/ double door |
| 55 | All as above item No43 but controller assembly single/ double door |
| 56 | All as above item No 43 but over load unit. |
| 57 | All as above item No 43 butmain PCB forsingle/ double doorrefrigerator of any capacity. |
| 58 | All as above item No43 butthermostate big/ small. |
| 59 | All as above item No 43 but condensation unit |
| 60 | All as above item No 43 but bulb & holder but make and model etc. |
| 61 | All as above item No 43 but door lock and key in origional but make and model etc. |
| 62 | All as above item No 43 but gasket or door bedding rubber for complete inner/outer unit. |
| 63 | All as above item No 43 but relay |
| 64 | All as above item No 43 but capacitor/ condensor |
| 65 | All as above item No 43but blower motor |
| 66 | All as above item No 43but chiller/ ice tray |
| 67 | All as above item No 43 but vegitable tray |
| 68 | All as above item No 43 but copper capillary cooling coil tubeassembly |
| 69 | All as above item No43 butreplacing to door hinges as origional |
| 70 | All as above item No 43 but door/ stand rubber cusion pad set |
| 71 | All as above item No 43 but temprature controll panel |
| 72 | All as above item No 43 but PVC mounting stand for refrigerator |
| 73 | All as above item No 43 but Timer assembly |
| 74 | Water heater or Geyser :-M&L for taking down water heater / geyser in any make/ model/ type/ size etc as site and open to body / connecting partsfor repair/ replaing to u/s spares ,servicing , cleaing, overhauling,paintingetc all as site after removing connections complete all as specified and directed.Note :(i)Spares shall be measured and paid seprately. (ii) Quoted rate shall be included transpotion charge in required (if required) |
| 75 | M&L for re-fixing and connectingto geyser after replacing to u/s spares, servicing ,overhauling,paintingetc all as site including newnut bolts and washer etc as site required and making electric connection using 3 core copper cable drawn through in PVC flexible conduit pipe and water connection as same at site completeall as specified and directed. Note ;- Nut bolts andwasher for fixing to geyser shall be suppy by contractor if required. |
| 76 | M&L for Painting towater heater / geyser in any make/ model/ size/ capacity using two coats over one coat of red oxide primer usingsyenthetic enamel/ heat resitance paint after washing with causting soda water ,scarping to old paint, cleaning etc and identy marking by different colour as per exisiting completeall as specified and directed. Note :- Colour of paint shall be approved by Engr-in- charge. |
| 77 | Supply and fix in replacement base assmebly for 25 Ltrs capacityinlet and outlet of geysermadeout of copper base plate with gasket, nuts, boltsand washer etc.suitablefor water heater/ geyser in any type /capacity / model /make /size etcas required in origional manufactures complete all as directed. Note :-(i) All spares shall be hold original manufacture tag with cat no.(ii)Spare will be suitable for MakeVoltas/ Blue star/ Havells/ Bajaj / Usha etc allas site. |
| 78 | All as above item No 77 but base assmebly for 50 Ltrs capacityinlet and outlet of geysermadeout of copper base plate with gasket, nuts, boltsand washer etc. Make - as per OEM |
| 79 | All as above item No77 but water heating element for 1.5/2KW cap Trinangular and round type .as per sample and make. |
| 80 | All as above item No 77 butThermostate asssembly manually adjustment type setting range with 35 to 65 CC. adjustable. |
| 81 | All as above item No 77 butauto temperature cut out unit |
| 82 | All as above item No 77 butindicator lamp 220 Volts AC |
| 83 | All as above item No 77butsafety pressure release valve. |
| 84 | S & F in repair float valve with epoxy coated aluminium arm , with PVC polythene ball suitable for water coolers completeall as specified and directed. |
| 85 | All as above item No 84 but metal connection pipe with metal sockets at both end inand for 90 cc hot water ISI mark. |
| 86 | S&F in replacement bib tap Cast copper alloy with crutch or butterfly handle, screwed for iron pipe 15 mm push type chromium plated completeall as specified and directed. |
| 87 | Supply onlyPVC insulated sheathed multistandred copper conductorcable 3 core 4 sqmm 1100 Volts grade completeall as specified and directed. |
| 88 | Supply only PVC insulated sheathed multistandred copper conductorcable 3 core 2.5 sqmm 1100 Volts grade completeall as specified and directed. |
| 89 | Supply and Laying SteelTubing 15mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 90 | Supply and Laying SteelTubing 20mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed. |
| 91 | Shifting and installation of split/window type AC any make/capacity at one place to another including necessary repair complete all as spacified and directed. |
| 92 | Supply and fixing/ laid/ concealed clamping of wall etc as site copper pipe for suction/Discharge linewith all fittings inbore of 1/2,1/4, 5/8, 3/4complete all as spacified and directed. |
| 93 | Supply and fixing and connecting in replacement of fully automatic single phase naturally air cooled indoor type wall mounting type digital voltage stabilizervoltage variation between 130 to300 voltswith output voltage stabilizer at 230 v with accuracyof +/- 2.5% of capacity 5 KVA(suitable up to 2 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed. Make : V-Guard model VD 500 in equivalent Microtech |
| 94 | All as above item No 93 but of capacity 4 KVA(suitable up to 1.5 Ton or 24000 Btu/Hr) W TDR complete all as specified and directed. Make : V-Guard model VD 500 in equivalent Microtech |
| 95 | Excavation of trenches in soft/loose soil n.exc 1.5 metre wide and n.exc 1.5 metre depth and getting out complete all as specified and directed. |
| 96 | Returning filling in approved earth, including spreading leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed |
| 97 | Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed. |
| 98 | Taking out old U/S underground LT cable of any size, any position from trenches, floors and walls, completeall as specified and directed. |
| 99 | Supply, fixing ,Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of10 Sqmm, 2 Core completeall as specified and directed. |
| 100 | Supply, fixing ,Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of10 Sqmm, 4 Core completeall as specified and directed. |
| 101 | Supply, fixing ,Testing and commissioning XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty) with stranded aluminum conductor, 1100Volt grade with fixing acessories of16 Sqmm, 4 Core completeall as specified and directed. |
| 102 | M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed. |
| 103 | Supply & laying in trenches GI pipe 50 mm bore light gradefor protection of U/G cable complete all as specified and as directed. |
| 104 | Supply & Laying Sub-Class old size B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed. |
| 105 | Taking down carefully existing unserviceable LED / HPSV/ MH Street light fitting of any watt from existing location to carry out the necessary Repairlike replacement of ballast, bipin holder, tubes etc and fixed to existing GI pipe bracket on pole including necessary electric connections complete all as specified and directed. |
| 106 | S&F of energy saving and environment friendly long life 90 W or next higher available rating, CT>=5700 K, LED street light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance not less than IK-07 complete with integrated type, with high efficiency electronic driver, built-in- surge suppressor / SPD of 10 KV or more and high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor >=0.90, operating range – 140 to 270 V, 50 Hz complete including suitablenecessary MS clamps, nuts, bolts etc. complete all as specified and as directed. |
| 107 | All as per item No.106 above but of 60 W capacity LED Street light. Make :- Havells/Crompton/ Wipro/Philips/Surya |
| 108 | All as per item No. 106 above but of 45 W capacity LED Street light.Make :- Havells/Crompton/ Wipro/Philips/Surya |
| 109 | All as per item No.106 above but of 25 W capacity LED Street light.Make :- Havells/Crompton/ Wipro/Philips/Surya |
| 110 | Supply, fixing energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source connecting and testing LED Flood lights of 200 watts capacityand unique peanut lens to ensure uniform distribution, complete all as specified and directed by the Engr-in-charge. |
| 111 | All as per item No.110 above but of 120 W capacity LED Flood light. |
| 112 | All as per item No. 110 above but of 70 W capacity LED Flood light. |
| 113 | All as per item No.110 above but of 50 W capacity LED Flood light. |
| 114 | S & F in replacement 8W LED outdoor new generation landscape lighting fitting Bamboo type with 1mtr length IP 65/66 protection including base to stand alone complete all as specified and directed. |
| 115 | S & F in replacement 8W LED outdoor new generation landscape lighting fitting Cone typewith IP 65 protection including base to stand alone complete all as specified and directed. |
| 116 | S & F in replacement 45 W LED outdoor New generation, Circular LED post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65/66 , IK-07 protection complete all as specified and directed. |
| 117 | S & F in replacement 15 W LED outdoor New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65/66 , IK-07 protection complete all as specified and directed. |
| 118 | S & F in replacement 25 W LED outdoor New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65/66 , IK-07 protection complete all as specified and directed. |
| 119 | S & F 35 W LED outdoor New generation, LED post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65/66 , IK-07 protection complete all as specified and directed. |
| 120 | Taking down carefully old unserviceable street light bracket with clamps of size 25/40/50mm from street tubular pole (light fitting) complete all as specified and as directed. |
| 121 | S&F street light bracket made out of GI tubing of size 32 mm, medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50 mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 122 | S&F street light bracket made out of GI tubing of size 25 mm, medium grade 1.50 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 50 mm x 6mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 123 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrodePCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part I |
| 124 | Supply and fix in replacement 3 core 1.5 sqmm multistranded PVC insulated flexible copper cable FRLS grade including required PVC Conduit to protect the cable complete all as specified and directed. |
| 125 | S&F in replacement MCB Single pole and neutral \"C\" curve 240 Volt 20 to 40 Amp capacity complete all as specified and directed. |
| 126 | S&F in replacementMCB Single pole 240 Volt 6 to 32 Amp capacity complete all as specified and directed. |
| 127 | S&F in replacement MCB TPN 415Volt 6 to 32 Amp capacity complete all as specified and directed. |
| 128 | Supply and fixing of street light thermoplastic cable junction box of size 200 x 160 x 98 mm IP 66, weather proof for outdoor installation with TPN terminal and MCB SP 6-20 A. complete all as specified and directed. |
| 129 | M & L for lowering of high mast carriage carefully from 20 mtr high structure for repairing light luminaries and raising latern carriage after repairing the light luminarises and adjust to its proper postion serving to winch mechanism pulleys steel wire ropes end terminal of SWR and greasing drain gearbox oil and toping up complete all as specified and directed. |
| 130 | Detecting the fault of line system of high Mast by providing skilled tradesman and helper with necessary safty tools and rectify the defects on top priority basis including testing completeall as specified and directed. |
| 131 | S&Fin repair analog timer switch , surface mounting as per sample for automatic operation of street light completeall as specified and directed. |
| 132 | S&F contactor modular type with ON/OFF indicator and label holder 3 pole 230 V40-63 Amps coil operating voltage 230 voltas per sample complete all as specified and directed. |
| 133 | S&F contactor modular type with ON/OFF indicator and label holder 4 pole 230 V 40-63 Amps coil operating voltage 230 voltcomplete all as specified and directed. |
| 134 | Supply and fixing in replacement of Automatic street light control switch Panel complete with, complete all as specified and directed.a) Infrared sensor based Nature Switch for automatic switching of street lights (Asto. Nature switch operation should be based on Natural light Lux level. Required luminance level for switching ON is less or equal to 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs. - 01 No.Make Of Sensor: L&T/SIEMENS/ HPL/Bajaj/ABBb) Power contactor two pole, 230 volts, 63 Amp capacity,confirming to IEC-60947-4-1. - 01 No.Make:- L&T/Schneider/ABB/Bajajc) The sensor along with suitable power contactor and incoming outgoing MCBs should be enclosed in a pole/ wall mountable rust proof, electric shock proof, termite proof and FR grade Thermoplastic polycarbonate enclosure (with hinged lid) confirming to IP66 protection class 2 of suitable size to accommodate all panel accessories. -01 Job.d) MCB SP 63 Amp, C Curve, Confirming to IEC-60898/IS8828. -02 Nos.Make: Hager/Schneider/L&T/ABBe) All control cable wiring inside the panel should be of copper conductor, multistandard, PVC insulated, FRLS, 1100 volts grade, of size 10 sq mm, single core, followed by colour coding and lugs/thimbles.Make: Finolex/Polycab/Plaza. (All ISI marked)f) All equipments are mounted on suitable size insulators.Make Of Complete Panel: Healer Enterprises, Model No: Swadeep-66-8KW1P. Or CPRI Approved Panel BuilderNote 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor\"s supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor\"s firm name while carrying out any activities in defence area for better check of security purpose.Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs) |