| Sl. No. | Item Description |
| 1 | Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures, fan regulators switch boards,switches,ceiling rose\"s lamp holder from existing batten PVCconduit/steel conduit / PVC casing and capping wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match all as specified and directed by Engr-in-Charge |
| 2 | Taking down main Switches,MCB DB with MCBs complete all as specified and directed |
| 3 | Taking down sub main wiring ofany sizes complete all as specified and directed |
| 4 | M & L for point wiring withFRLS insulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC casing capping and accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity conductor cable ofsize 1.5 Sqmm green colour Connected to common earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers all as specified for the following :- |
| 5 | (i) One light / fan/bell point controlled by one way switch |
| 6 | (ii) One socket outlet 5 Amps on independent board |
| 7 | (iii) One socket outlet 5 Amps on the same board |
| 8 | All as per aboveherein before butwith 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed |
| 9 | All as per aboveherein before butwith 4 Sqmm for phase & neutral and 4 sqmm for earth wire for AC point independent 15 AMP complete all as specified and directed |
| 10 | M & L for point wiring with FRLSinsulated 1100 Volts grade single core multistranded Copper conductor cable 1.5 Sqmm drawn and including PVC conduit and accessories, concealed in wall conduit on ceiling (for fan/down lighter only) etc with necessary fixing accessories and earth continuity conductor cable ofsize 1.5 Sqmm green colour Connected to common earth and earth dolly including pressed steel terminal boxes concealed in wall Covered with laminated sheet top cover of required thickness for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine screws and washers including making good the disturbed surface and painting the surface with colour matching to the wall colour all as specified for the following :- |
| 11 | (i) One light / fan/bell point controlled by one way switch |
| 12 | (ii) One socket outlet 5 Amps on independent board |
| 13 | (iii) One socket outlet 5 Amps on the same board |
| 14 | All as per Srl Item No 10.00 aboveherein before butwith 2.5 Sqmm for phase & neutral and 2.5 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed |
| 15 | All as per Srl Item No 10.00 above herein before butwith 4 Sqmm for phase & neutral and 4 sqmm for earth wire for socket out let 15 Amps complete all as specified and directed |
| 16 | Supply and Fix in repairsofSwitch piano flush type single pole one way 5 Amp complete all as specified and directed. |
| 17 | Supply and Fix in repairs ofCeiling rose surface bakelitetwo to three terminal complete all as specified and directed. |
| 18 | Supply and Fix in repairs of Fan regulator electronic step type 240 V complete all as specified and directed. |
| 19 | Supply and Fix in repairs of Bell push flush type 5 Amps complete all as specified and directed. |
| 20 | Supply and Fix in repairsof Electronic CallBell 230 volts single pole AC complete all as specified and directed. |
| 21 | Supply and Fix in repairs of Switch socket combined two in one 06 pin 5/15 Amps flush type universal complete all as specified and directed. |
| 22 | Supply and Fix in repairsofSwitch Socket multipurpose 5 pin 5 Amps 240 V flush type complete all as specified and directed. |
| 23 | Supply and Fix in repairs ofLamp holder,insulated body with back plate complete all as specified and directed |
| 24 | M&L MCCB DB vertical type made of sheet steel , powder painted with neutral bus bar 200 A, neutral link,IP-30-IK08 protection grade , 415Volts TPN with 8 way Double door complete all as specified and directed, |
| 25 | M&L MCCB DB vertical type made of sheet steel , powder painted with neutralbus bar 200 A, neutral link,IP-30-IK08 protection grade , 415Volts TPN with 4 way Double door complete all as specified and directed |
| 26 | M&L MCCB TPN 100 Amps , 415Volts, 25KA ,3 Pole complete all as specified and directed |
| 27 | M&L MCCB TPN 160 Amps , 415Volts, 25KA ,3 pole complete all as specified and directed |
| 28 | Supply and Fix in repairsof MCB DB SPN 8 Way Double door type 240 Volts complete all as specified and directed. |
| 29 | Supply and Fix in repairs of MCB DB TPN 4 Waydouble door type 415 V with bus bar complete all as specified and directed |
| 30 | Supply and Fix in repairs single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 25 Amp 240 Volts complete all as specified and directed. |
| 31 | Supply and Fix in repairsofMCB TPN 63 Amps 415 Volts complete all as specified and directed. |
| 32 | Supply and Fix in repairs of MCB SP 06 to 32 Amps 240 Volts complete all as specified and directed. |
| 33 | Supply and Fix in repairsof SPN 6- 32 Amps 240 Volts complete all as specified and directed. |
| 34 | Supply and Fix in repairs of MCB SPN 40 Amps 240 Volts complete all as specified and directed |
| 35 | Supply and Fix in repairs of MCB SPN 63 Amps 240 Volts complete all as specified and directed. |
| 36 | NOTE FOR ITEM NO 24 to 35 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB to be fixed on wall including framemade out of MS flat 40x5mm(2).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface |
| 37 | M&L for Sub Mainwiring with two single core 2.5 SqmmFRLS insulated multistranded flexible copper conductor cable 660/1100 volts gradedrawn in through rigid flexible PVC casing -n- capping/PVC conduit with and including PVC insulated 2.5 Sqmm single core multi strand copper conductor as continuous earth wire in green colour connected to common earth dolly all as specified and as directed.Note:- 1. Two runs of cable and one run of earth wire inch PVC conduit will be measured and paid one unit. 2. Separate sub main wiring will be run for each acne |
| 38 | M&L for Sub Main wiring complete with 4.0 Sqmm FRLS insulated1100 Volt grade with multistranded copper conductor cable with and including drawn through PVC casing -n- capping/PVC conduitwith all accessories fixed on Walls/floors/roofs with and including pressed steel terminal sunken boxes fixed on the existing sunken portion (Where the old boxes are removed under respective item) with 3 mm laminated bakelite sheet top cover fixed with cadmium plated screws, cup washer for housing metal clad plug socket for ACPoint including provision of 4 sqmm PVC insulated copper wire as earth continuity conductor and connecting to common earth dolly all as specified. |
| 39 | All as per Srl Item No 38.00 above herein before but with 6 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable drawn in through PVC casing -n- capping/PVC conduitcomplete with all accessories including provision of 6.0 sq. mm FRLS insulated copper wire as earth continuity conductor all as specified and as directed. |
| 40 | S & F LED retrofit lamp B-22 holder based with polycarbonate bodyand aluminium heat sink with warm white, 7W LED Lamp,all as specified and as directed by Engr-in-Charge. |
| 41 | S & F LED retrofit lamp B-22 holder based with polycarbonate bodyand aluminium heat sink with warm white, 9W LED Lamp,all as specified and as directed by Engr-in-Charge at site |
| 42 | S&F energy efficient light emitting LED light fitting 1x 18/20 watt, four feet , white fittings with LED rod complete with all accessories & Provn ofthree core cable of copper conductor of size 0.75 sqmm, making necessary electric connection from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed |
| 43 | S&F for energy efficient light emitting LED light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories& Provn ofthree core cable of copper conductor of size 0.75 sqmm, making necessary electric connection from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed. |
| 44 | S&F in Repairs LED Light luminariesSquare type 36W suitable suitable for Modular/pop/Gypsum ceiling with starter, connector block, etc,complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible conductor of copper withPVC square blocks of size 600mmX600mm for fixing the fitting complete all as specified and directed. |
| 45 | Material and labour Modular white cover plate with frame of following types complete all as specified and directed. Of the following:- |
| 46 | (a) White cover plate with frame, 1 module |
| 47 | (b) White cover plate with frame 2 module |
| 48 | (c) White cover plate with frame 4 module |
| 49 | (d) White cover plate with frame 6 module |
| 50 | (e) White cover plate with frame 8 module |
| 51 | Material and labour Modular switch 1 way 6A, 1 module complete all as specified and directed |
| 52 | Material and labour Modular Bell push, flush type, 5 amp complete all as specified and directed |
| 53 | Material and labour Fan step regulator, 120W - 2 module complete all as specified and directed |
| 54 | Material and labour Modular metal box flushtype 1 /2/3 module complete all as specified and directed |
| 55 | Material and labour Modular metal box flushtype 4 module complete all as specified and directed |
| 56 | Material and labour Modular metal box flushtype 6 module complete all as specified and directed |
| 57 | Material and labour Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch 16 Amps complete all as specified and directed |
| 58 | Draining out the old slugs oil from the DG set andreplace with new oil as recommended by Mfg. NOTE : Draining out of Oil shall be done twice in year each time refiling/Top upwill be measured & paid separately. |
| 59 | Disconnecting old unserviceable battery 12 Volts DC upto 180 AHfrom Engine & transporting to work shop for refilling electrolyte, distilled water, checking of sp gravitycomplete& initial chargingof the battery for 48 hours min, transporting back to site , reconnecting up complete all as directed by EIC at site |
| 60 | M&L for in Replacement of timer assembly with four pole selector switch complete including alteration of existing wiring for power pass in existing panel for DG SET 15 KVA to 160 KVA all as directed.Make : L&Tor equivalent. |
| 61 | Servicing of AMF Panel suitable for DG Set DG Set15 KVA to 160 KVAincluding cleaning properly with blower, checking of control wiring , replacement of burnt out / damaged wiring connections, calibration of control relay, replacement of control fuses / MCBs allas directed by Engineer in Charge. NOTE :- Spare parts shall be measured and paid separately in respective item of thisschedule if required. |
| 62 | M&L for in replacement LED type Indicator |
| 63 | M&L for in replacement Control relay 9/11 pin 12 /24 volt DC Make : AMRONor equivalent. |
| 64 | M&L for in replacement Digital ammeter with built in selector switchMake : NIPPON / CONZERVE |
| 65 | M&L for in replacementMicro processor unit for automatic and manual function as specified Make : Kirloskaror equivalent. |
| 66 | M&L for in replacement Contactor Type ML-4. Make:- L&Tor equivalent. |
| 67 | M&L for in replacement Contactor Type ML-2. Make:- L&Tor equivalent. |
| 68 | M&L for in replacement CT of ratio upto 150 / 5 10 VA burden Make:- AE/NIPPON |
| 69 | M&L for in replacement Fault Indicator Control Relay Model No SU 01 of RB Electronics of Kirloskar |
| 70 | M&L for in replacement Fault Indicator Control Relay Model No KRB 101 of RB Electronics of Kirloskar |
| 71 | M&L for in replacement Temperature gauge |
| 72 | M&L for in replacement Oil Pressure Gauge 0-10 Bar |
| 73 | M&L for in replacement Digital Frequency meterMake -NIPPON/CONSVER |
| 74 | M&L for in replacement DC Volt meter 0 to 30 volt |
| 75 | M&L for in replacement DC ammeter 0 to 2 amp |
| 76 | N&L for in replacementExcitation coil for DG Set15 KVA to 160 KVA DG SET |
| 77 | M&L for in replacementAVR card for DG Set15 KVA to 160 KVA DG SET |
| 78 | M&L for Servicing of Self Starter 12/24 Volt DC forDG Set15 KVA to 160 KVADG Set, dismantlingcomplete,& replacement of solenoid field coils. cleaning the commutator strips includingreplacing the bearing,bends pinion re-assembling, connecting and testing complete all as directed by Engineer-in-charge |
| 79 | M&L forin replacementself starter 12 volt DC for DG Set15 KVA to 160 KVA DG SET including all accessories complete all as directed by Make : LUCASor equivalent. |
| 80 | M&L for in replacement oil Feed Pump for Aquastic DG SET for capacity DG Set15 KVA to 160 KVA Make -KIRLOSKARor equivalent. |
| 81 | M&L for in replacementalternator for battery charging 12/24 volt DC complete with all accessories . |
| 82 | Draining out the Water from the radiator, dis-mantling the leakingradiator assembly complete from the engine body, transporting to workshop, cutting the bottom chambers, repairing the damaged pipes, brazing theleaking portions ,descaling / clearing all the blocked pipes including repairing the fins, brazing the bottom chambers, testing the radiator for leaks, transporting the same to the site and re-fixingand testing complete in the presence ofEngineer-in-charge. for Capacity DG Set15 KVA to 160 KVA. |
| 83 | M&L for in replacementsolenoid Switch 12 Volt DC. Make: LUCAS |
| 84 | M&L for in replacement Stopping relay 24 volt DC. Make:- Lucas |
| 85 | M&L for in replacementAnti - Vibrating Pad suitable forDG Set15 KVA to 160 KVADG Set.. Make:- LOVE JOY/DON LOP |
| 86 | M&L for in replacementIgnition Switch for capacityup to DG Set15 KVA to 160 KVA DG SET. |
| 87 | M&L for Coolant as required for top up.Make : MAX Super Cool for Acoustic DG SET. |
| 88 | M&L for Refilling of distilled water for top up battery 12 volt DC. |
| 89 | M&L in replacementFuel pipes with benjo bolt and washers.For capacity DG Set15 KVA to 160 KVA DG SET. |
| 90 | M&L for in replacementHeavy duty Battery terminal for 12 volt DCbattery suitable AH at site. |
| 91 | M&L for in replacementRadiator Hose pipe as per existing Set of 2 |
| 92 | M&L for inreplacmennt Door Lock Assembly with key for Acoustic DG SET. |
| 93 | M&L for in replacementHeavy dutyAutomatic electronic battery charger suitable for 12/24 Volt DC |
| 94 | M&L for in replacementRubber Coupling with nut bolt & washer in between Alternator& Engines& DG Set15 KVA to 160 KVA DG SET |
| 95 | M&L for in replacementBattery lead with lug as per existing length & size forcapacity DG Set15 KVA to 160 KVA |
| 96 | M&L in replacementAir Filterinside & out side for capacity DG Set15 KVA to 160 KVA |
| 97 | M&L in replacementPrimary Fuel Filter for capacityDG Set15 KVA to 160 KVA |
| 98 | M&L in replacementSecondary Fuel Filter for capacityDG Set15 KVA to 160 KVA. |
| 99 | M&L in replacement Lubricating Oil Filter for capacityDG Set15 KVA to 160 KVA. |
| 100 | M&L in replacementV- Belt as per existing size for capacity DG Set15 KVA to 160 KVA |
| 101 | M&L in replacement Diesel pipe PVC Flexible up to 12 mm for capacity DG Set15 KVA to 160 KVA. |
| 102 | M & L in replacement of Genset controller for DG Set15 KVA to 160 KVA |
| 103 | M & L in replacementVoltage Monitoring Relay(VMR) |
| 104 | M & L in replacementOEN Relay |
| 105 | M & L in replacementTimerfor controlling voltage shifting from no load to full load complete all as specified and directed by Engr-in-charge |
| 106 | M & L in replacementwater pump of capacity DG Set15 KVA to 160 KVA |
| 107 | M & L in replacement Coolant Hose set for DG Set15 KVA to 160 KVA |
| 108 | M & L in replacement Fuel hose set for DG Set15 KVA to 160 KVA |
| 109 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipeline and getting out, in hard/dense Soil complete all as specified and directed by Engineer-in-charge. |
| 110 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for taking out/laying pipe line and getting out,in soft/loose Soil complete all as specified and directed by Engineer-in-charge.. |
| 111 | Returning, filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed by Engineer-in-charge.. |
| 112 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.. |
| 113 | Disconnecting ,dismantling and taking down of unserviceable rusted water tubing GI of size 100/80 mmfrom existing place in trenches/wall/floors/ceilings complete all as specified and directed by Engineer-in-Charge: |
| 114 | All as per Srl Item No 113.00 above but GI of size 50 mm complete aii as specified and directed by Engineer-in-Charge. |
| 115 | All as per Srl Item No 113.00 above but GI of size 40 mm complete aii as specified and directed by Engineer-in-Charge. |
| 116 | All as per Srl Item No 113.00 abovebut GI of size 25 mm complete aii as specified and directed by Engineer-in-Charge. |
| 117 | Supplying & Laying, connecting and testing GI pipe 100 mm bore medium grade including necessary fittings in trenches complete all as specified and directed by Engineer-in-charge. |
| 118 | All as per Srl Item No 117.00 above here-in-before but of size 80 mm bore complete all as specified and directed by Engineer-in-charge. |
| 119 | All as per Srl Item No 117.00 abovehere-in-before but of size 50 mm bore complete all as specified and directed by Engineer-in-charge. |
| 120 | All as per Srl Item No 117.00 above here-in-before but of size 40 mm bore complete all as specified and directed by Engineer-in-charge. |
| 121 | All as per Srl Item No 117.00 above here-in-before but of size 25 mm bore complete all as specified and directed by Engineer-in-charge. |
| 122 | Dismantling and taking out unserviceable Sluice Valveof size 80 mmbore from line complete all as directed by Engineer-in-charge. |
| 123 | Dismantling and taking out unserviceable Sluice Valveof size100 mm bore from line complete all as directed by Engineer-in-charge. |
| 124 | Supply and fix in repairs Sluice Valve Class PN 1.680 mm dia with iron wheel head, gaskets nuts, bolts,washerscomplete all as directed by Engineer-in-Charge. |
| 125 | Supply and fix in repairs Sluice Valve Class PN 1.6100 mm dia with iron wheel head, gaskets nuts, bolts,washerscomplete all as directed by Engineer-in-Charge. |
| 126 | Dismantling and taking out unserviceable gun metal gate valve of size 50 mm to 40 mm bore from line complete all as specified and as directed by Engr - in- charge. |
| 127 | Dismantling and taking out unserviceable gun metal gate valve/stop valve of size 25 mm to 20 mm complete all as specified and as directed. |
| 128 | Supply and fixgun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsizes 50 mm dia complete all as specified and as directed by Engineer - in-Charge: |
| 129 | Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsizes 40 mm dia complete all as specified and as directed by Engineer - in-Charge: |
| 130 | Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsizes 25 mm dia complete all as specified and as directed by Engineer - in-Charge: |
| 131 | Supply and fix gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe ofsizes 20 mm dia complete all as specified and as directed by Engineer - in-Charge: |
| 132 | Dismantling damage and broken valve chamber of size 1200x1200x900mm including unserviceable rusted MS cover complete without disturbingthe existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 502x50x6mm MS complete with 2 coat of synthetic enamelled paint over a coat of red oxide on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge. |
| 133 | All as per Srl Item No 132.00 above here-in-before but of size 900 mm X 900 mm X 900 mm internal complete all as specified and directed by Engineer-in-charge. |
| 134 | Material and Labour for PCC (1:2:4) type B-1 for supporting pillar posts for pipes/flooring/paving / foundation for motor etc complete all as specified and directed by Engineer-in-charge. |
| 135 | Material and Labour for brick work with subclass B bricks in cement mortar 1 : 4 , straight or curved on plan exc 6m mean radius built in including taking down unserviceable bricks complete all as specified and directed by Engineer-in-charge. |
| 136 | Material and Labour for cutting bituminous surfaces road to a depth of n exc 60cm and not exceeding 60cm in width for taking out or laying of GI tubing and refilling the same with necessary making good works complete all as specified and as directed by Engineer-in-charge |
| 137 | Demolition and dismantling of Cement concrete of any description and in any position and removing the materials to a distance not exceeding 100 m all as directed by Engr in Charge |
| 138 | Material. fabricated, and erecting for base frame / Iron Ladder/Duct coversofUG Tank / OH Tank for centrifugal pump set fabricated out of structural steel sections such as joint, channel, angle, or tee sections including grouting nuts bolts, washers , checknuts etc and painting the frame with two coats of rust proof paint over a coat of zinc primerincluding dismantling and taking down rusted steel items from existing places complete all as directed by Engr-in-Charge |
| 139 | Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation towork shop of3 to 5 HP pumping setfor repairs/ rewinding.Dismantling the pump set complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts,dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enamelled copper winding wire of same gauge varnishing the stator & drying in oven reassembling the pump set complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing complete all as directed by Engineer-in-charge |
| 140 | All as per Srl Item No 139.00 above herein but for motor of capacity7.5 HP complete all as directed by Engineer-in-charge |
| 141 | Supply and fixing in repairs fully automatic DOL starter suitable for 3 to 5 HP Pumping set415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T / Bhartiya Cutler Hammer ” |
| 142 | Supply and fixing in repairs fully automatic DOL starter suitable for 7.5 HP Pumping set415 volts 3 phase as existing in panel board including taking down existing starter complete all as specified and directed .Make “Siemens / L&T / Bhartiya Cutler Hammer ” |
| 143 | Supply and fixingin repairsContactor ML-33 Pole with DC Coilsuitable for 3 to 5 HP415 volts 3 phase motor including taking down existing contactors complete all as directed by Engineer-in.-charge |
| 144 | Supply and fixingin repairsContactor ML-33 Pole with DC Coilsuitable for 7.5 HP415 volts 3 phase motor including taking down existing contactors complete all as directed by Engineer-in-charge. |
| 145 | S & F in repairs Single Phase Preventerfor motor protection Circuit Breaker up to 7.5 HP Motor including taking down existing. |
| 146 | Supply and Fix foot valve of Brass of Size 80 MM Dia complete all as specified and Directed by Engr-in-Charge. |
| 147 | Cleaning of RCC UG sumps of 10000 Gallon capacities by involvingof the followings 08(Eight) stage of cleaning process complete all as specified and directed(i)De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump(iii)Cleaning of walls, floors, ceiling etc complete(iv)Removing dirt and sludge by vacuum pump(v) Anti- Bacterial Treatment of inside of tank which effective againstall pathogens all complete.(vi) Applying one coat of white wash internal surfaces.(vii)Replace nylon net for vent pipes &man hole cover(viii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :-(i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge.(iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day.(iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots,Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system. |
| 148 | Cleaning of RCC UG sumps of 7500/7000 Gallon capacities by involvingof the followings 08(Eight) stage of cleaning process complete all as specified and directed(i)De-watering by high pressure submersible pump all complete (ii) Removal of sludge from sump(iii)Cleaning of walls, floors, ceiling etc complete(iv)Removing dirt and sludge by vacuum pump(v) Anti- Bacterial Treatment of inside of tank which effective againstall pathogens all complete.(vi) Applying one coat of white wash internal surfaces.(vii)Replace nylon net for vent pipes &man hole cover(viii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note :-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :-(i) The contractor shall be provide dewatering pump of suitable capacity. The rate is inclusive of rent/hiring charge complete. (ii) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(iii) Material removed from the tank shall be disposed all as per direction of Engineer-in-charge.(iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day. |
| 149 | Cleaning ofRCC Over Head Tanks of 15000/20000 Gallon capacities by involvingof the followings 07(SEVEN) stage of cleaning process complete all as specified and directed(i)De-watering by all complete (ii) Removal of sludge fromRCC Over Head Tanks(iii)Cleaning of walls, floors, ceiling etc all complete(iv)Removing dirt and sludge by vacuum pump(v) Applying one coat of white wash internal surfaces.(vi)Replace nylon net for vent pipes &man hole cover(vii)Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc Note:-The tenderer shall take into consideration for following points while quoting his rate for this item andthe unite rate is deemed be included for :-(i) Cuttingand filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked.(ii) Material removed from the tank shall be disposed off at out side.(iii) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job with the given period only. or otherwise penalty shall be imposed @ Rs 1000/- per day.(iv) All safety with Gadgets like Safety Belts, Special Safety Ladder, Helmets, Heavy Duty Gum Boots,Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system. |
| 150 | Disconnecting, dismantling and taking out after disconnecting of incoming and outgoing water & electric connections & transportation towork shop of 3 to 5 HP pumping setfor repairs/ rewinding.Dismantling the pump set complete, separating the parts such as rotor, impellar,bearing, shaft seal, shaft cleaning of all dismantled parts,dismantling the motor and cutting & removing burnt winding from slot cleaning the slots , packing the slots with insulated packing material, rewinding with super enamelled copper winding wire of same gauge varnishing the stator & drying in oven reassembling the pump set complete with and including new packing material, gland packing , stud, new set of bearings, terminal plate, transporting back to plant room, refixing on foundation connecting up and testing complete all as directed by Engineer-in-charge |
| 151 | All as per above here in but for motor of capacity above 5 HP to 7.5 HP complete all as directed by Engineer-in-charge |
| 152 | S&F MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts ,complete all as specified and as directed by Engineer-in-Charge. |
| 153 | S&F MCB ,SPN 240 volt 40 Amp ,complete all as specified and as directed by Engineer-in-Charge. |
| 154 | S&F MCB single Pole 240 Volts 6 to 40 Amp ,complete all as specified and as directed by Engineer-in-Charge. |