| 1 | Supply of L.T protection for 25 KVA Distribution Transformer |
| 2 | Supply ofL.T Fuse set Proction Unit suitable for 25 KVA Distribution Transformer with Box as per specification. |
| 3 | Supply of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 4 | Supply and Installation of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit. |
| 5 | Supply ofL.T protectionfor 63KVADistribution Transformer |
| 6 | Supply of L.T Fuse set Proction Unit suitable for 63 KVA Distribution Transformer with Box as per specification. |
| 7 | Supply of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 8 | Supply of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit. |
| 9 | Supply of L.T. protection for 100KVA Distribution Transformer |
| 10 | Supply of L.T Fuse set Proction Unit suitable for 100 KVA Distribution Transformer with Box as per specification. |
| 11 | Supply of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 12 | Supply and Installation of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit. |
| 13 | Supply of L.T. protectionfor 250 KVADistribution Transformer |
| 14 | Supply of Henley Type Tailness Unit Protection Cubical Panel 2 Nos Circuits 500 Amp 650 Volt as per specification Confirming to Henley Stanard Suitable of Protection of 250 KVA Distribution Transformer. |
| 15 | Supply of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 16 | Supply of ISI MarkedL.T. XLPE Alluminum Cable of size 1x400 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit. |
| 17 | Supply of L.T. protectionfor 400 KVADistribution Transformer |
| 18 | Supply of Henley Type Tailness Unit Protection Cubical Panel 3 Nos Circuits 500 Amp 650 Volt as per specification Confirming to Henley Stanard Suitable of Protection of 400 KVA Distribution Transformer. |
| 19 | Supply of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 20 | Supply of ISI MarkedL.T. XLPE Alluminum Cable of size 1x630 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit. |
| 21 | Installation Work of L.T. protection for 25 KVA Pole Mounted Distribution Transformer |
| 22 | Installation of L.T Fuse set Proction Unit Pole mounted suitable for 25 KVA Distribution Transformer with Box as per specification. |
| 23 | Installation ofEarthing of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 24 | Installation of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit to Pole with proper dressing, lugging and winding etc. |
| 25 | Installation Work of L.T. protection for 63KVA Pole Mounted Distribution Transformer |
| 26 | Installation of L.T Fuse set Proction Unit Pole mounted suitable for 63 KVA Distribution Transformer with Box as per specification. |
| 27 | Earthing of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 28 | Installation of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit to Pole with proper dressing, lugging and winding etc. |
| 29 | Installation Work of L.T. protectionfor 100KVA Pole Mounted Distribution Transformer |
| 30 | Installation of L.T Fuse set Proction Unit Pole mounted suitable for 100 KVA Distribution Transformer with Box as per specification. |
| 31 | Earthing of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 32 | Installation of ISI MarkedL.T. XLPEAlluminum Cable of size 1x240 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit to Pole with proper dressing, lugging and winding etc. |
| 33 | Installation Work of L.T. protectionfor 250 KVADistribution Transformer |
| 34 | Installation of Henley Type Tailness Unit Protection Cubical Panel 2 Nos Circuits 500 Amp 650 Volt as per specification Confirming to Henley Stanard Suitable of Protection of 250 KVA Distribution Transformer. |
| 35 | Installation and Grouting of LT Protection Cubical Panelon 30 cm height foundation above ground as per specification. |
| 36 | Installation ofEarthing of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 37 | Installation of ISI MarkedL.T. XLPE Alluminum Cable of size 1x400 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit to Pole with proper dressing, lugging and winding etc. |
| 38 | Installation Work of L.T. protection for 400 KVADistribution Transformer |
| 39 | Installation of Henley Type Tailness Unit Protection Cubical Panel 3 Nos Circuits 500 Amp 650 Volt as per specification Confirming to Henley Stanard Suitable of Protection of 400 KVA Distribution Transformer. |
| 40 | Installation and Grouting of LT Protection Cubical Panelon 30 cm height foundation above ground as per specification. |
| 41 | Installation ofEarthing of L.T. protection Fuse set Unit Panel by M.S. earthing rod size 20x2500 mm |
| 42 | Installation of ISI MarkedL.T. XLPE Alluminum Cable of size 1x630 sqmm from Distribution Transformer L.T. Side to L.T. Protection Fuse Set Unit and L.T Protection Fuse Set Unit to Pole with proper dressing, lugging and winding etc. |