Tender For Repair / Replacement Of Ht Ug Cable, Maint Of Rmu, Maint / Overhauling Of Transformer And Vcb, 22 Kv Sub Station Equipment And Other Misc Works At Naval Station Karanja

Issued by Statutory Bodies & Commissions/Committees · karanja, Maharashtra
Tender Value
88 Lakhs
Estimated cost
Bid Submission
22 Feb 2025
0 days left
EMD
1.57 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
karanja → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair / Replacement Of Ht Ug Cable, Maint Of Rmu, Maint / Overhauling Of Transformer And Vcb, 22 Kv Sub Station Equipment And Other Misc Works At Naval Station Karanja

BOQ

NAME OF WORK : REPAIR / REPLACEMENT OF HT UG CABLE, MAINT OF RMU, MAINT / OVERHAULING OF TRANSFORMER AND VCB, 22 KV SUB-STATION EQUIPMENT AND OTHER MISC WORKS AT NAVAL STATION KARANJA
Sl. No. Item Description
1Dismantling top cover alongwith conservator tank for filtration of Transformer oil and after draining out transformer oil up to terminal level in situ by dismantling copper bus barsHT/LV Bushingand earthing strips, replacement of LT/HT bushing and terminal rod of brass gasket, nuts, bolts & washers etc. Refitting top cover & conservator tank after cleaning and filtration, removing the sludge , reconnecting HT/LT cable/conductor with bushings and earthing strips,& filtration of transformer oilincluding toping up of transformer oil by adding new transformer oil having 60 KV dielectric strength and charging/testing the transformer on load complete all as specified and directed by Engineer-in-charge, for transformer of rating upto 160 KVA capacity. Notes :(i) Contractor should make his own arrangement of filtration plant at each transformer sites for filtration of transformer oil including provision of electric supply to the filtration plant.(ii) New transformer oil shall be measured and paid separately.(iii) Cost of HT/LT bushing and terminal rod will be measured and paid separately.(iv) Filtration of oil will be measured separately.(v)Contractor has to test di-electric strength breakdown voltage before and after filtration of oil and record of the same duly signed by Engineer in charge and contractor to be kept on record.
2Ditto- all as per item No 1.00 here-in-before but for transformer of rating 200 KVA.
3Ditto- all as per item No 1.00 here-in-before but for transformer of rating 250 KVA.
4Ditto- all as per item No 1.00 here-in-before but for transformer of rating 315 KVA.
5Ditto- all as per item No 1.00 here-in-before but for transformer of rating 400 KVA.
6Ditto- all as per item No 1.00 here-in-before but for transformer of rating 500 KVA.
7Ditto- all as per item No 1.00 here-in-before but for transformer of rating 630 KVA.
8Ditto- all as per item No 1.00 here-in-before but for transformer of rating 1000 KVA.
9Supply onlythe following spare partsoftransformer 22 /0.433 KV operated in item Nos1.00 to 8.00 here-in-before :-
10HV Bushings, 22 KV from up to 160 KVA
11HV Bushings, 22 KV from 200 KVA to 630 KVA
12HV Bushings, 22 KV1000 KVA
13HV terminal rod with nut bolts, caps etc, 22 KV from up to 160 KVA
14HV terminal rod with nut bolts, caps etc, 22 KV from 200 KVA to 630 KVA
15HV terminal rod with nut bolts, caps etc, 22 KV1000 KVA
16LV Bushings, 22 KV from up to 160 KVA
17LV Bushings, 22 KV from 200 KVA to 630 KVA
18LV Bushings, 22 KV1000 KVA
19LV terminal rod with nut bolts, caps etc, 22 KV from up to 160 KVA
20LV terminal rod with nut bolts, caps etc, 22 KV from 200 KVA to 630 KVA
21LV terminal rod with nut bolts, caps etc, 22 KV1000 KVA
22LT Brass connectors, 12 mm
23LT Brass connectors, 20 mm
24LT Brass connectors, 30 mm
25LT Brass connectors, 42 mm
26Supply and Fix in repairs Dial type temperature gauge 100mm dia with dual calibration in degree Celsius and degree Fahrenheit, range 0 to 100 °C and equivalent degree Fahrenheit complete with capillary tube and sensor suitable for transformer of any rating all as specified and directed by Engineer-in-charge.
27Supply and filling new transformer oil having 60 KV di-electric strength and conforming to IS : 335 for replacement or topping up to oil level mark at the conservator, all as specified and directed by Engineer-in-charge.
28Material for rewinding of transformer core with same numbers/grade of copper enamelled conductor with same size of turns as per manufacturer\"s specification and testing and commissioning transformers after repair, all as specified and directed by Engineer-in-charge.
29Material for re-insulation of copper windings (LT and HT), Class B, with Electrical Grade Insulating Kraft paper all confirming to IEC-60554-3-5 (1984), complete all as specified and directed by Engineer-in-charge.
30Filtration of transformer oil, in-situ, to achieve dielectric strength of the oil not less than 50 KV with 2.5 mm gap, complete all as specified and directed by Engineer-in-charge. Note : Contractor will submit before and after testing report of transformer oil.
31Disconnecting HT/LT and earth termination connections from transformer of capacity 75 to 1000 KVA, taking down the transformers from plinth/platform and loading into the vehicle; transporting the same to workshop for carrying out necessary repairs and back , reconnecting HT/LT connections at site and charging the transformer on load, commissioning and testing including Megger test at site, complete all as specified and directed by Engineer-in-charge.
32Draining out transformer oil, dismantling top cover alongwith conservator tank, taking out core assembly after disconnecting connections, rewinding with same size and type of copper conductor and number of turns and insulating material such as paper insulator sleeves, heating etc. Putting back the core assembly into the tank after removing sludge and replacement of HT & LT bushing complete with brass terminal, refixing top cover and conservator including replacement of gasket, nut, bolts & washers (filling new transformer oil having 60 KV dielectric strength and carrying out type tests as per IS 2026 in presence of Engineer - in - charge for the following capacity :-Notes :- (i)New transformer oil and its filling shall be measured and paid separately under relevant items of schedule.(ii)Cost of rewinding material, insulation material and spares of transformer shall be measured and paid separately under relevant item of Schedule.(iii) Replacement of spares will be on required basis all as directed by Engr-in Charge.
3375 to 160 KVA
34200 to 315 KVA
35400 to 1000 KVA
36Disconnecting HT/ LT and earth termination connections from Trolley Mounted Transformer (500 KVA Capacity) and towing the same to a location, within 5 Km, as directed by Engr-in-Charge including Material and Labour for making of HT/ LT and earth termination connections of the Trolley Mounted Transformer to the existing electric distribution system in Indoor/Outdoor Substation complete all as specified and directed by Engr-in-Charge. Notes :- (a) Trolley Mounted transformer will be issued to contractor by MES however Contractor has to make his own arrangements of towing vehicle.(b) The job also includes disconnecting ofHT/ LT and earth termination connections of Trolley Mounted Transformer and towing the same to a location as directed by Engr-in-Charge.
37Testing of transformers of various capacities installed at various locations at Naval Station Karanja by performing following tests, complete all as specified and directed by Engr-in-Charge : -1. IR Value on L.V & H.V side using 500 V & 5KV Megger respectively.2. Ratio on all the taps.3. Magnetic Balance tests on L.V & H.V.4. Vector group.5. Magnetizing current.6. Winding Resistance Test on H.V & L.V terminals.Notes : (i) Contractor should make his own arrangement of testing equipments and electric supply so required.(ii) A detailed Test Report should be submitted to Engr-in-Charge.
38Supply and Fix in repairs heat shrink right angled boots for XLPE 22 KV 120 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers, complete all as specified and directed by Engr-in-Charge.
39Material and Labour in repair for Heat shrinkable cable end termination joint including jointing Kit outdoor typesuitable for earthed 3 core 95/120 sqmm HT 22KV XLPE aluminium conductor cable and HV test after jointing and connecting up, complete all as specified and directed by Engr-in-Charge.
40Material and Labour in repair for Heat Shrinkable straight through jointing kit with all necessary jointing material suitable for HT 22 KV XLPE 3 core 95/120 sqmm aluminium conductor cable, complete all as specified and directed by Engr-in-Charge.
41Supply and Fix in repairs breather assembly with silica gel suitable in-situfor transformer of any rating, complete all as specified and directed by Engr-in-Charge.
42Supply and fixing CRC bottle spray of 500 mL for opening of rusty surfaces and rusty nut bolts, complete all as specified and directed by Engr-in-Charge.
43Taking out winding worn out dry type transformer of capacity 100 KVA to 400 KVA after testing at side by authorised Engineerto the workshop with necessary arrangements by giving the supply with trolley mounted transformer and refixing the same after complete repairs, all as specified and directed by Engr-in-Charge.
44Material and Labour for preparation of old paintedsurfaces of 100 KVA transformer with scrapers,any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painted including writing 5mm/MES numbers, complete all as specified and directed by Engr-in-Charge.
45Ditto- all as per item No 25.00 here-in-before but 160 KVA transformer.
46Ditto- all as per item No 25.00 here-in-before but200/250 KVA transformer
47Ditto- all as per item No 25.00 here-in-before but315 KVA transformer
48Ditto- all as per item No 25.00 here-in-before but400/500 KVA transformer
49Ditto- all as per item No 25.00 here-in-before but630 KVA transformer
50Ditto- all as per item No 25.00 here-in-before but1000 KVA transformer
51Material and Labour for cleaning and checking the LT/HT connections of dry type transformers and taking out the moisture from the cores of the transformer of capacity 62.5 KVA to 250 KVA all as specified and as directed by Engineer-in-charge.
52Material and Labour for cleaning and checking the LT/HT connections of dry type transformers and taking out the moisture from the cores of the transformer of capacity 315 KVA to 750 KVA all as specified and as directed by Engineer-in-charge.
53Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 75 KVA to 250 KVA all as specified and as directed by Engineer-in-charge.
54Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 315 KVA to 500 KVA all as specified and as directed by Engineer-in-charge.
55Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 625 KVA to 1000 KVA all as specified and as directed by Engineer-in-charge.
56Periodical Check / preventive maint of HT VCB/RMU 22 KV 800 Amps, 50 Hz yearly 3 times as under :-(a) Checking the closing & opening operation of VCB and functional checks and Repair/ Replacement of the defective components.(b) Overhauling and Calibration of relays (secondary injection/Primary injection on each multiple setting of relays).(c) Setting and coordination of relays.(d) Checking and recording of IR value of VCB trolley and panel.(e) Checking/repairing/rectification of the control wiring.(f) Replacement of panel heater 80 watt.(g) Replacement of worn outbushing CT/Busbar support insulators.(h) Replacement of worn outbushing PT/Busbar support insulators.(j) Replacement of unserviceable and Open circuit CT\"s. (k) Checking fibre plates, gaskets and applying multi grease to the mechanical parts & dry graphite conductive sealant to contacts of PT etc. and re-assembling the same and commissioning complete to entire satisfaction of Engineer-in-Charge.(l) Testing of polarities of CT\"s.(m) High voltage testing with high voltage tester of CT & Breaker pole to withstand working pressure of HT 22 KV to ascertain serviceability and spare parts found defective to be replaced for smooth functioning as directed by Engineer-in-Charge.(n) Labour only for Opening the busbar chamber of HT 22KV VCB panel board cleaning the bus bar chamber, inspect the CT\"s wiring, spout insulator & bus-bar joints & tightening if required & heating up with hot air blower to remove moisture, meggering, HV testing applying TRTPPEX(B) supplied against Sl Item No 39.02 here-in-after to bus bar & commissioning complete all as specified & directed by Engineer-in-Charge.
57Notes for item No 37.00 here-in-before :(i) All spares required for replacement shall be measured and paid separately under respective item of schedule here-in-after as supply only.(ii) Machine grease, oil, liquid sealant and any minor item costing upto Rs 250 will be included in the unit rate of above item and for satisfactory function of the breakers and no extra cost will be allowed. Decision of accepting officer in this regard will remain final & binding.(iii) The overhauling of HT breakers to be carried out either through OEM\"s service Engineer/authorised dealer/San & Engg consultant /Triotech consultant/ those who posses HT handling license.
58Supply only following spare parts required for item No 37.00 here-in-before, all as specified and directed by Engr-in-Charge:-Note:- The element of fixing of spare is already included in respective Serial Item No 37.00 here-in-before suitable for VCB of 800 Amps all as per sample.
59Spout insulator (Epoxy)
60TRTPPX (B) for HT 22 KV for breaker
61Current Transformer 22 KV single phase indoor Resin cast CT Ratio 30-15/5-5 Amps Class 1.0 insulation level 28 KV/75 KV as per IS 2075
62Strip type heater 80 watt
63Closing coil
64Tripping coil
65PT Primary fuse 22KV 23 Amps
66Control fuse 2 Amps with HRC fuse and fuse holder in existing panel and as specified and directed.Make:EE/Standard/Havells/L&T or equivalent as approved by the GE.
67Insulation Tape suitable for HT 22 KV 1.5\" wide. Make : 3M or equivalent as approved by the GE.
68VCB gasket suitablefor VCB 22KV 800 Amps indoor type all as specified and directed.
69Baffle pot assembly suitable for VCB, 22 KV, 800 Amps, indoor type all as specified and directed by Engr-in-Charge.
70Main moving contact bolted/threaded type suitable for VCB, 22KV, 800Amps, indoor type all as specified and directed by Engr-in-Charge.
71PT single phase indoor Resin cast PT Ratio 22kV/R3/110V/R3 Class 1.0, 200VA.
72HT bushing with spindle
73Thermostat - 0-100 Deg. Celsius
74Moving contact rod
75Upper fix contact
76Lower fix contact
77Top and bottom male contact
78Female contact
79Support insulator
80Partition fiber plate
81Copper strip of 800 Amps (per Kg)
82Material and Labour for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mmby means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soilto a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using (20mm graded stone aggregate), \"mild steel angle iron frame\" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 40mm dia mediumgrade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown inelectrical \"plate No \"3\" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed by Engr-in-Charge.
83Supply and Fix earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm all as specified and directed by Engr-in-Charge.
84Supply, laying in repairs, in trenches /ducts/fixing on pole/STR with suitable size of GI clamp made out of GI strip 32 mm x 6 mm, XLPE HT insulated, screened, earthed, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) ofsize 3 x 120 sqmm with aluminium conductor suitable for 22 KV grade as per relevant IS including latest amendment for IS (ISI marked cable) testing, commissioning along with HT cable route indicator complete all as specified and directed by Engr-in-Charge.Notes :- (a) Earth work, EHV cable cover, sand cushioning & GI pipe will be measured and paid separately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.
85Taking out carefully cable covers &HT cable from excavated trench/duct/pole of size 120 sqmm 3 core, all as specified and directed by Engr-in-Charge.
86Relaying of HT cable of size 120 sqmm 3 core in trench/duct/pipe obtained from ser item No 43.00 here-in-before
87Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed by Engr-in-Charge.
88Removing excavated materials n exc 50m and depositingwhere directed at a level not exc 1.5m above the Starting point, all as specified and directed by Engr-in-Charge.
89Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge.
90Supply and lay sand cushioning to under ground HT cable complete all as specified in SSR Part-I and as directed by Engineer-in-charge.
91Supply and Laying reinforced precast concrete cable cover laid width wise factory made, class EHV type 1 with peak size 450 mm x 230 mm x 50 mm complete all as specified and directed by Engr-in-Charge.
92Laying only precast concrete cover of size 450mm x 230mm x 50 mm obtained from ser item No 43.00 here-in-before
93Material and Labour for drawing 3 phase with aluminium conductor, steel reinforced DOG, all as specified and directed by Engr-in-Charge.
94Material and Labour for notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 22 KV of size 25 x 20 cm, all as specified and directed by Engr-in-Charge.
95Material and Labour for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat one under coat and two finishing coats of aluminium paint, all as specified and directed by Engr-in-Charge.
96Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all as specified and directed by Engr-in-Charge.
97Supply and fix in repair following spare parts for out door type ring main units of various configuration complete all as specified and as directed by Engr-in-charge.
98Ring LT/CT 30/1A, 2.5VA CL-5P10
99LT CT Resin cast iron type ratio - 100/1A, 2.5VA CL-1.0
100PT 22KV/Root 3/110V/ Root 3, 50 VA-CL-1/EE090562, 3 Phase
101Auxiliary transformer 22KV/Rt3/230V, AC, 500VA
102HT Fuse 22 KV/3.15A/EE090344
103CS FPI -earth fault indicator, E/F-10-100A, with 1NO+1NC, sensor-100-120mm dia with 3m wire, indicator model : CSFPI-E-A-H
1048 way battery and charger I/P 230V, O/P 24V DC, 10A (flat type) (12 V X02 battery)
105Digital MFM meter flush mounted, size-96x96mm, AC, class 1.0, Aux-40-300V AC model elite 303, CT & PT ratio programmable with RS 485 port
106O/C & E/F self powered relay-CSDPR-V2-300-D-L-N-M-C1 with modbus 1A, AUX supply-18-60V DC O/C minimum setting-10% & E/F- minimum setting-5%
107Local Remote switch 3 Pole/2W/ EE090691
108PCI / 37302001-01
109LBS function motor UN2-30 24VDC / 37303017-01
1109 micro switch kit /33111884-01
111Relay electm 24V DC 5A 4C /O/ 9423140
112Relay electm 230V AC 5A 4C /O/ 9423142
113Relay electm 4C/ O BASE / 9423230
114Push button flush type (Red) with carrier
115Push button flush type (Green) with carrier
116Contact element 1 NO green Cat Rb2-BE101
117Terminal block fuse type elmex model=KUDF4
118VCB function spring charging motor, 120W 24V DC, Type:PMR5
119Tripping coil
120Closing coil
121Micro limit switch, Model-D-38, rating-16A, 1 HP, 125/250V AC
122Aux switch 6 NO + 6 NC
123Pressure switch/ 33210204-01
12410A, 230V AC 2 pole with on/off toggle switch, CAT : Kaycee
125Material and Labour in repair GI pipe Light grade with all fittings complete laidin trenches/fixed on pole with suitable clamp all as specified for 80 mm bore of pipe for protection of UG cable, all as specified and directed by Engr-in-Charge.
126Material and Labour in repair for Disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 22 KV complete all as specified and directed by Engr-in-Charge.
127Material and Labour in repair for Pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 22000 volts grade 205 mm dia & 215 mm height, complete all as specified and directed by Engr-in-Charge.
128Ditto- all as per item No 58.00 here-in-before, but Post type insulator.
129Supply and install HT 22 KV Gang Operated Air Break Switch, horizontal 3 insulator type complete with handle, pipe and all mechanical fittings 400 Amps double break rotating type with earth switch, all as specified and directed by Engr-in-Charge.Make:- Atlas/Pactil /ABB / Crompton or equivalent as approved by the GE.
130Material and Labour for overhauling i.e greasing, cleaning of GOD and adjustment of its operation complete all as specified and directed by Engineer-in-Charge.
131Material and Labour for fixed type top contact for DO fuse units in replacement complete all as specified and directed by Engr-in-Charge.
132Material and Labour for fixed type bottom contact for DO fuse units in replacement complete all as specified and directed by Engr-in-Charge.
133Supply and Fix following spares of vertical type GOD 22 KV grade, 200 Amps rating in position as in repairs including testing after repairs:-
134Male contact
135Female contact
136Tinned copper flexible jumper
137MS Jumper carrier
138Back connector plate
139Supply and install HT 22 KV, 200 Amp outdoor type gang operated single break switch Tilting type vertical mounting consisting of hot dip galvanised channel iron base having 2 Nos 22 KV Post type insulator in stack and 3 stack per phase copper or copper alloy high pressure heavily tinned contacts plated MS arcing horns capable of breaking the magnetizing current complete with horizontal connecting square bar, GI pipe as down rod levers coupling & operating handle with locking arrangement, all as specified and directed by Engr-in-Charge.
140Supply and install drop out lift OFF HT 22 KV, 200 Ampsfuse link consisting of channel iron base having 2 Nos 22 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385, complete all as specified and directed by Engr-in-Charge.
141Material and Labour in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed by Engr-in-Charge.
142Material and Labour in repairs outdoor type, oil cooled, single phase, single pole wound primary, live tank OIP insulated current transformer dual core having ratio 120-60/1-1A (ratio change by means of tap on secondary winding) insulation Class A, burden 15 VA Class I for metering & 5P-10for protection complete all as specified and directed by Engr-in-Charge.
143Supply and fix following spare partsof HT 22 KV SF-6, 800 Amps outdoor type circuitbreaker controlled by indoor panel, complete all as specified and directed by Engr-in-Charge :-
144Limit switch with Bracket
145Operation Counter Assembly
146Carbon Brushes With Cap
147Emery Pads
148Auxiliary switch stack 5 NO+5NC
149Door Gasket
150Chemistic
151Compound Gauge
152Compound Gauge(small)
153Anabond 680 (1 tube=100gms)
154Local Remote switch 3 Pole
155Trip Coil (single) -30V DC
156Close Coil-30V DC
157Set of Circlips, Split Pins ,Dowel Pins etc
158Darina Grease(1 Packet= 250 Gm)
159Torsion Spring Right
160Torsion Spring Left
161TNC switch 2 Pole
162DC Contactor
163Space heater 80 W
164Thermostat
165Spring Charging Motor
166SF-6 Gas filling device with gas filling
167Anti pumping device
168Material and Labour in repairs \"T\" hard connector made of cast aluminium suitable for ACSR conductor complete all as specified and directed by Engr-in-Charge.
169Material and Labour in repairs 4 \"U\" bolt hardware made of cast aluminium suitable for end disc insulator complete all as specified and directed by Engr-in-Charge.
170Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 32mm x DOG conductor complete all as specified and directed by Engr-in-Charge.
171Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 12mm x DOG conductor complete all as specified and directed by Engr-in-Charge.
172Material and Labour in repairs brass spindlewith 32mm dia for CT\"s with Universal bushing complete all as specified and directed by Engr-in-Charge.
173Supply and laying in repairs synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-Charge. Makes :- ATLAS /Jyoti or equivalent as approved by the GE.
174Disconnecting HT 22 KV grade XLPE cable of any size from structure/pole/transformer for finding fault by computer aided fault finding machine and locating exact location by thumping and necessary earth work to expose faulty cable piece and cutting faulty cable andtesting remaining cable with High voltage tester to withstand the cable as normal working pressure HT 22 KV complete all as specified and directed by Engineer-in-Charge.Note :- Excavation and earth work and Material and Labour for joints shall be measured and paid under relevant Item of schedule separately.
175Labour only for upkeep of HT out door structure by removing grass, shrubs, trimming branches of trees near to structure removing cleaning, screening for mud etc and relaying of same stone aggregate complete all as specified and directed by Engr-in-Charge.
176Supply and Fix Auxiliary High speed Master trip relay, Type AVAJH13 , contact 3 NO+2 NC HR , Auxiliary Voltage : 24 VDC or 110 VDC, all as specified and directed by Engr-in-Charge.
177Supply and Fix 3 phase Over Current + Earth Fault Relay with High Set & RS-485 Port with IDMT and definite time characteristics, password protection, Aux supply (V) of 24-240V, AC/DC, Output contacts 4 No, all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE, CAT Part No.- MC61CNX4000, Model - MC61Cnx.
178Preparation of old painted surface including removing old paint, rust, dust, oil, grease and any other foreign deposits by paint removers or burning off by blow lamps and cleaning with scrapers and chemicals for removal of rust for any number of coats, any width or girth & Material and Labour for application of aluminium paint one coat for 6 pole structure (steel or tubular) / channels/angles /GODs etc. all as specified and directed by Engr-in-Charge.
179Ditto- all as per item No 80.00 here-in-before, but 4 pole structure
180Ditto- all as per item No 80.00 here-in-before, but 2 pole structure
181Supply, installation, testing and commissioning in repair HT 22 KV out door type, IP-66 protection factory fabricated feeder pillar box made out of 3.25 mm thick cold rolled MS sheet steel with double door and locking arrangement, duly painted with anti corrosive high quality post office red colour, suitable for 22 KV, 3 Phase, 50 Hz, 630 Amps, AC system to loop one incoming and one outgoing 3 x 120 Sqmm XLPE cable with all accessories complete all as specified and directed by Engr-in-Charge, comprising the following specifications :-(a)The HT feeder pillar shall have front and rear compartments, front compartment shall be connecting the terminals of cables and rear for terminations, Bakelite sheet 12mm thick shall provide for separation cable termination at front.(b)Adequate ventilation by means of louvers with wire mesh on both sides and at the top and bottom of feeder pillars.(c)Asbestos sheets of at least 6mm thick shall be provided on inside of all doors. (d)Enamelled name plate mentioning name of manufacturer, serial number and date of installation shall be displayed on front door.(e)Two Nos of earthing bolts shall be provided with the cubicle at front and rear side of feeder pillar.(f)Cable entry shall be from rear side of pillar.Removable gland plate of 10 SWG MS sheet shall be provided.Cable chamber shall be provided with perforated metal sheet separate for each chamber.(g)The set of bus bar 630 Amps rated shall be made up of electrolytic grade copper and provided with heat shrinkable PVC sleeve for RYB codes.(h)The insulating material used shall be Epoxy type insulator with uniform equally spaced rings, suitable for 33 KV class insulation.Make :-M/s Super Panel/Hupen/Switch Build Engg India Pvt Ltd/ Pune switch gears/SV Power System Mumbai or equivalent as approved by the GE.
182Supply and Fix following spares of Horizontal type GOD 22 KV grade, 400 Amps rating in position as in repairs including testing after repairs, all as specified and directed by Engr-in-Charge :-
183Male contact
184Female contact
185Copper rod/Plate
186Copper Bare conductor of 4 SWG
187Copper Bare conductor of 6 SWG
188Material and Labour for DO fuse Element stranded silver/Tin coated copper wire soldered joint with ferrule and fire resistant tube type rating 2.5Amps complete all as specified and directed by Engr-in-Charge.
189Ditto- all as per item No 85.00 here-in-before, but rating 5 Amps
190Ditto- all as per item No 85.00 here-in-before, but rating 10 Amps
191Ditto- all as per item No 85.00 here-in-before, but rating 15 Amps
192Ditto- all as per item No 85.00 here-in-before, but rating 20 Amps
193Ditto- all as per item No 85.00 here-in-before, but rating 30 Amps
194Ditto- all as per item No 85.00 here-in-before, but rating 40 Amps
195Ditto- all as per item No 85.00 here-in-before, but rating 60 Amps
196Ditto- all as per item No 85.00 here-in-before, but rating 80 Amps
197Ditto- all as per item No 85.00 here-in-before, but rating 100 Amps
198Material and Labour for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations complete all as specified and directed by Engr-in-Charge.
199Supply and filling in layers not exc 25cm thick with 40mm graded coarse aggregates in structures complete all as specified and directed by Engr-in-Charge.
200Material and Labour for fixing of GI Nut and Bolts with washer of different sizes in HT structures complete all as specified and directed by Engr-in-Charge.
201Material and Labour for self bonding electrical HT tape of size 1.9cm x 9.15m x 0.076cm for cable joints, transformers, HT structure joints, all as specified and directed by Engr-in-Charge. Make : 3M or equivalent as approved by the GE.
202Material and Labour for HT lugs in the rectification of HT faults of size 95 Sqmm, all as specified and directed by Engr-in-Charge.
203Material and Labour for HT lugs in the rectification of HT faults of size 120 Sqmm, all as specified and directed by Engr-in-Charge.
204Material and Labour for HT lugs in the rectification of HT faults of size 150 Sqmm, all as specified and directed by Engr-in-Charge.
205Material and Labour for HT lugs in the rectification of HT faults of size 185 Sqmm, all as specified and directed by Engr-in-Charge.
206Material and Labour for HT lugs in the rectification of HT faults of size 185 Sqmm, all as specified and directed by Engr-in-Charge.
207Material and Labour for Petroleum Jelly in HT Nut bolt joints, T- joints, U joints in CTs and PTs on the HT structure, all as specified and directed by Engr-in-Charge.
208Supply only for HT gloves for 22 KV HT line, all as specified and directed by Engr-in-Charge.

AI Tender Summary

OUR REF NO 47393575
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 88 Lakhs
LAST DATE 22-02-2025
Authority
Authority Name Military Engineer Services
Work Description Repair / Replacement Of Ht Ug Cable, Maint Of Rmu, Maint / Overhauling Of Transformer And Vcb, 22 Kv Sub Station Equipment And Other Misc Works At Naval Station Karanja
Basic Detail
Tender No 84401-K/E8
Bidding Type Tender
Location
City karanja
State Maharashtra
Key Dates
Publish Date 25 Jan 2025
Submission Date 22 Feb 2025
Open Date 24 Feb 2025
Finance
Tender Value 88 Lakhs
Tender Fee 1000
EMD 1.57 Lakhs
Exemption Not Available
Document List
afb52097-3268-4ab6-bceb-5b8915a70653.html
BOQ_778121.xls
SOC84401.pdf
Tenderdocuments8401.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 25, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 22, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 24, 2025

Bid Opening Date

Technical bids will be opened and evaluated.