Tender For Repair / Replacement Of Ht Ug Cable, Maint Of Rmu, Maint / Overhauling Of Transformer And Vcb, 22 Kv Sub Station Equipment And Other Misc Works At Naval Station Karanja
Tender Value
88 Lakhs
Estimated cost
Bid Submission
22 Feb 2025
0 days left
EMD
1.57 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
karanja → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair / Replacement Of Ht Ug Cable, Maint Of Rmu, Maint / Overhauling Of Transformer And Vcb, 22 Kv Sub Station Equipment And Other Misc Works At Naval Station Karanja
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling top cover alongwith conservator tank for filtration of Transformer oil and after draining out transformer oil up to terminal level in situ by dismantling copper bus barsHT/LV Bushingand earthing strips, replacement of LT/HT bushing and terminal rod of brass gasket, nuts, bolts & washers etc. Refitting top cover & conservator tank after cleaning and filtration, removing the sludge , reconnecting HT/LT cable/conductor with bushings and earthing strips,& filtration of transformer oilincluding toping up of transformer oil by adding new transformer oil having 60 KV dielectric strength and charging/testing the transformer on load complete all as specified and directed by Engineer-in-charge, for transformer of rating upto 160 KVA capacity. Notes :(i) Contractor should make his own arrangement of filtration plant at each transformer sites for filtration of transformer oil including provision of electric supply to the filtration plant.(ii) New transformer oil shall be measured and paid separately.(iii) Cost of HT/LT bushing and terminal rod will be measured and paid separately.(iv) Filtration of oil will be measured separately.(v)Contractor has to test di-electric strength breakdown voltage before and after filtration of oil and record of the same duly signed by Engineer in charge and contractor to be kept on record. |
| 2 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 200 KVA. |
| 3 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 250 KVA. |
| 4 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 315 KVA. |
| 5 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 400 KVA. |
| 6 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 500 KVA. |
| 7 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 630 KVA. |
| 8 | Ditto- all as per item No 1.00 here-in-before but for transformer of rating 1000 KVA. |
| 9 | Supply onlythe following spare partsoftransformer 22 /0.433 KV operated in item Nos1.00 to 8.00 here-in-before :- |
| 10 | HV Bushings, 22 KV from up to 160 KVA |
| 11 | HV Bushings, 22 KV from 200 KVA to 630 KVA |
| 12 | HV Bushings, 22 KV1000 KVA |
| 13 | HV terminal rod with nut bolts, caps etc, 22 KV from up to 160 KVA |
| 14 | HV terminal rod with nut bolts, caps etc, 22 KV from 200 KVA to 630 KVA |
| 15 | HV terminal rod with nut bolts, caps etc, 22 KV1000 KVA |
| 16 | LV Bushings, 22 KV from up to 160 KVA |
| 17 | LV Bushings, 22 KV from 200 KVA to 630 KVA |
| 18 | LV Bushings, 22 KV1000 KVA |
| 19 | LV terminal rod with nut bolts, caps etc, 22 KV from up to 160 KVA |
| 20 | LV terminal rod with nut bolts, caps etc, 22 KV from 200 KVA to 630 KVA |
| 21 | LV terminal rod with nut bolts, caps etc, 22 KV1000 KVA |
| 22 | LT Brass connectors, 12 mm |
| 23 | LT Brass connectors, 20 mm |
| 24 | LT Brass connectors, 30 mm |
| 25 | LT Brass connectors, 42 mm |
| 26 | Supply and Fix in repairs Dial type temperature gauge 100mm dia with dual calibration in degree Celsius and degree Fahrenheit, range 0 to 100 °C and equivalent degree Fahrenheit complete with capillary tube and sensor suitable for transformer of any rating all as specified and directed by Engineer-in-charge. |
| 27 | Supply and filling new transformer oil having 60 KV di-electric strength and conforming to IS : 335 for replacement or topping up to oil level mark at the conservator, all as specified and directed by Engineer-in-charge. |
| 28 | Material for rewinding of transformer core with same numbers/grade of copper enamelled conductor with same size of turns as per manufacturer\"s specification and testing and commissioning transformers after repair, all as specified and directed by Engineer-in-charge. |
| 29 | Material for re-insulation of copper windings (LT and HT), Class B, with Electrical Grade Insulating Kraft paper all confirming to IEC-60554-3-5 (1984), complete all as specified and directed by Engineer-in-charge. |
| 30 | Filtration of transformer oil, in-situ, to achieve dielectric strength of the oil not less than 50 KV with 2.5 mm gap, complete all as specified and directed by Engineer-in-charge. Note : Contractor will submit before and after testing report of transformer oil. |
| 31 | Disconnecting HT/LT and earth termination connections from transformer of capacity 75 to 1000 KVA, taking down the transformers from plinth/platform and loading into the vehicle; transporting the same to workshop for carrying out necessary repairs and back , reconnecting HT/LT connections at site and charging the transformer on load, commissioning and testing including Megger test at site, complete all as specified and directed by Engineer-in-charge. |
| 32 | Draining out transformer oil, dismantling top cover alongwith conservator tank, taking out core assembly after disconnecting connections, rewinding with same size and type of copper conductor and number of turns and insulating material such as paper insulator sleeves, heating etc. Putting back the core assembly into the tank after removing sludge and replacement of HT & LT bushing complete with brass terminal, refixing top cover and conservator including replacement of gasket, nut, bolts & washers (filling new transformer oil having 60 KV dielectric strength and carrying out type tests as per IS 2026 in presence of Engineer - in - charge for the following capacity :-Notes :- (i)New transformer oil and its filling shall be measured and paid separately under relevant items of schedule.(ii)Cost of rewinding material, insulation material and spares of transformer shall be measured and paid separately under relevant item of Schedule.(iii) Replacement of spares will be on required basis all as directed by Engr-in Charge. |
| 33 | 75 to 160 KVA |
| 34 | 200 to 315 KVA |
| 35 | 400 to 1000 KVA |
| 36 | Disconnecting HT/ LT and earth termination connections from Trolley Mounted Transformer (500 KVA Capacity) and towing the same to a location, within 5 Km, as directed by Engr-in-Charge including Material and Labour for making of HT/ LT and earth termination connections of the Trolley Mounted Transformer to the existing electric distribution system in Indoor/Outdoor Substation complete all as specified and directed by Engr-in-Charge. Notes :- (a) Trolley Mounted transformer will be issued to contractor by MES however Contractor has to make his own arrangements of towing vehicle.(b) The job also includes disconnecting ofHT/ LT and earth termination connections of Trolley Mounted Transformer and towing the same to a location as directed by Engr-in-Charge. |
| 37 | Testing of transformers of various capacities installed at various locations at Naval Station Karanja by performing following tests, complete all as specified and directed by Engr-in-Charge : -1. IR Value on L.V & H.V side using 500 V & 5KV Megger respectively.2. Ratio on all the taps.3. Magnetic Balance tests on L.V & H.V.4. Vector group.5. Magnetizing current.6. Winding Resistance Test on H.V & L.V terminals.Notes : (i) Contractor should make his own arrangement of testing equipments and electric supply so required.(ii) A detailed Test Report should be submitted to Engr-in-Charge. |
| 38 | Supply and Fix in repairs heat shrink right angled boots for XLPE 22 KV 120 Sqmm cable including dismantling of HT cable from HT side of Transformer / HT Breakers, complete all as specified and directed by Engr-in-Charge. |
| 39 | Material and Labour in repair for Heat shrinkable cable end termination joint including jointing Kit outdoor typesuitable for earthed 3 core 95/120 sqmm HT 22KV XLPE aluminium conductor cable and HV test after jointing and connecting up, complete all as specified and directed by Engr-in-Charge. |
| 40 | Material and Labour in repair for Heat Shrinkable straight through jointing kit with all necessary jointing material suitable for HT 22 KV XLPE 3 core 95/120 sqmm aluminium conductor cable, complete all as specified and directed by Engr-in-Charge. |
| 41 | Supply and Fix in repairs breather assembly with silica gel suitable in-situfor transformer of any rating, complete all as specified and directed by Engr-in-Charge. |
| 42 | Supply and fixing CRC bottle spray of 500 mL for opening of rusty surfaces and rusty nut bolts, complete all as specified and directed by Engr-in-Charge. |
| 43 | Taking out winding worn out dry type transformer of capacity 100 KVA to 400 KVA after testing at side by authorised Engineerto the workshop with necessary arrangements by giving the supply with trolley mounted transformer and refixing the same after complete repairs, all as specified and directed by Engr-in-Charge. |
| 44 | Material and Labour for preparation of old paintedsurfaces of 100 KVA transformer with scrapers,any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painted including writing 5mm/MES numbers, complete all as specified and directed by Engr-in-Charge. |
| 45 | Ditto- all as per item No 25.00 here-in-before but 160 KVA transformer. |
| 46 | Ditto- all as per item No 25.00 here-in-before but200/250 KVA transformer |
| 47 | Ditto- all as per item No 25.00 here-in-before but315 KVA transformer |
| 48 | Ditto- all as per item No 25.00 here-in-before but400/500 KVA transformer |
| 49 | Ditto- all as per item No 25.00 here-in-before but630 KVA transformer |
| 50 | Ditto- all as per item No 25.00 here-in-before but1000 KVA transformer |
| 51 | Material and Labour for cleaning and checking the LT/HT connections of dry type transformers and taking out the moisture from the cores of the transformer of capacity 62.5 KVA to 250 KVA all as specified and as directed by Engineer-in-charge. |
| 52 | Material and Labour for cleaning and checking the LT/HT connections of dry type transformers and taking out the moisture from the cores of the transformer of capacity 315 KVA to 750 KVA all as specified and as directed by Engineer-in-charge. |
| 53 | Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 75 KVA to 250 KVA all as specified and as directed by Engineer-in-charge. |
| 54 | Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 315 KVA to 500 KVA all as specified and as directed by Engineer-in-charge. |
| 55 | Material and Labour for arresting the leakage and checking out of the LT/HT connections from the transformers of capacity 625 KVA to 1000 KVA all as specified and as directed by Engineer-in-charge. |
| 56 | Periodical Check / preventive maint of HT VCB/RMU 22 KV 800 Amps, 50 Hz yearly 3 times as under :-(a) Checking the closing & opening operation of VCB and functional checks and Repair/ Replacement of the defective components.(b) Overhauling and Calibration of relays (secondary injection/Primary injection on each multiple setting of relays).(c) Setting and coordination of relays.(d) Checking and recording of IR value of VCB trolley and panel.(e) Checking/repairing/rectification of the control wiring.(f) Replacement of panel heater 80 watt.(g) Replacement of worn outbushing CT/Busbar support insulators.(h) Replacement of worn outbushing PT/Busbar support insulators.(j) Replacement of unserviceable and Open circuit CT\"s. (k) Checking fibre plates, gaskets and applying multi grease to the mechanical parts & dry graphite conductive sealant to contacts of PT etc. and re-assembling the same and commissioning complete to entire satisfaction of Engineer-in-Charge.(l) Testing of polarities of CT\"s.(m) High voltage testing with high voltage tester of CT & Breaker pole to withstand working pressure of HT 22 KV to ascertain serviceability and spare parts found defective to be replaced for smooth functioning as directed by Engineer-in-Charge.(n) Labour only for Opening the busbar chamber of HT 22KV VCB panel board cleaning the bus bar chamber, inspect the CT\"s wiring, spout insulator & bus-bar joints & tightening if required & heating up with hot air blower to remove moisture, meggering, HV testing applying TRTPPEX(B) supplied against Sl Item No 39.02 here-in-after to bus bar & commissioning complete all as specified & directed by Engineer-in-Charge. |
| 57 | Notes for item No 37.00 here-in-before :(i) All spares required for replacement shall be measured and paid separately under respective item of schedule here-in-after as supply only.(ii) Machine grease, oil, liquid sealant and any minor item costing upto Rs 250 will be included in the unit rate of above item and for satisfactory function of the breakers and no extra cost will be allowed. Decision of accepting officer in this regard will remain final & binding.(iii) The overhauling of HT breakers to be carried out either through OEM\"s service Engineer/authorised dealer/San & Engg consultant /Triotech consultant/ those who posses HT handling license. |
| 58 | Supply only following spare parts required for item No 37.00 here-in-before, all as specified and directed by Engr-in-Charge:-Note:- The element of fixing of spare is already included in respective Serial Item No 37.00 here-in-before suitable for VCB of 800 Amps all as per sample. |
| 59 | Spout insulator (Epoxy) |
| 60 | TRTPPX (B) for HT 22 KV for breaker |
| 61 | Current Transformer 22 KV single phase indoor Resin cast CT Ratio 30-15/5-5 Amps Class 1.0 insulation level 28 KV/75 KV as per IS 2075 |
| 62 | Strip type heater 80 watt |
| 63 | Closing coil |
| 64 | Tripping coil |
| 65 | PT Primary fuse 22KV 23 Amps |
| 66 | Control fuse 2 Amps with HRC fuse and fuse holder in existing panel and as specified and directed.Make:EE/Standard/Havells/L&T or equivalent as approved by the GE. |
| 67 | Insulation Tape suitable for HT 22 KV 1.5\" wide. Make : 3M or equivalent as approved by the GE. |
| 68 | VCB gasket suitablefor VCB 22KV 800 Amps indoor type all as specified and directed. |
| 69 | Baffle pot assembly suitable for VCB, 22 KV, 800 Amps, indoor type all as specified and directed by Engr-in-Charge. |
| 70 | Main moving contact bolted/threaded type suitable for VCB, 22KV, 800Amps, indoor type all as specified and directed by Engr-in-Charge. |
| 71 | PT single phase indoor Resin cast PT Ratio 22kV/R3/110V/R3 Class 1.0, 200VA. |
| 72 | HT bushing with spindle |
| 73 | Thermostat - 0-100 Deg. Celsius |
| 74 | Moving contact rod |
| 75 | Upper fix contact |
| 76 | Lower fix contact |
| 77 | Top and bottom male contact |
| 78 | Female contact |
| 79 | Support insulator |
| 80 | Partition fiber plate |
| 81 | Copper strip of 800 Amps (per Kg) |
| 82 | Material and Labour for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mmby means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soilto a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using (20mm graded stone aggregate), \"mild steel angle iron frame\" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 40mm dia mediumgrade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown inelectrical \"plate No \"3\" and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing complete all as specified and directed by Engr-in-Charge. |
| 83 | Supply and Fix earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm all as specified and directed by Engr-in-Charge. |
| 84 | Supply, laying in repairs, in trenches /ducts/fixing on pole/STR with suitable size of GI clamp made out of GI strip 32 mm x 6 mm, XLPE HT insulated, screened, earthed, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) ofsize 3 x 120 sqmm with aluminium conductor suitable for 22 KV grade as per relevant IS including latest amendment for IS (ISI marked cable) testing, commissioning along with HT cable route indicator complete all as specified and directed by Engr-in-Charge.Notes :- (a) Earth work, EHV cable cover, sand cushioning & GI pipe will be measured and paid separately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above. |
| 85 | Taking out carefully cable covers &HT cable from excavated trench/duct/pole of size 120 sqmm 3 core, all as specified and directed by Engr-in-Charge. |
| 86 | Relaying of HT cable of size 120 sqmm 3 core in trench/duct/pipe obtained from ser item No 43.00 here-in-before |
| 87 | Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and directed by Engr-in-Charge. |
| 88 | Removing excavated materials n exc 50m and depositingwhere directed at a level not exc 1.5m above the Starting point, all as specified and directed by Engr-in-Charge. |
| 89 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 90 | Supply and lay sand cushioning to under ground HT cable complete all as specified in SSR Part-I and as directed by Engineer-in-charge. |
| 91 | Supply and Laying reinforced precast concrete cable cover laid width wise factory made, class EHV type 1 with peak size 450 mm x 230 mm x 50 mm complete all as specified and directed by Engr-in-Charge. |
| 92 | Laying only precast concrete cover of size 450mm x 230mm x 50 mm obtained from ser item No 43.00 here-in-before |
| 93 | Material and Labour for drawing 3 phase with aluminium conductor, steel reinforced DOG, all as specified and directed by Engr-in-Charge. |
| 94 | Material and Labour for notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 22 KV of size 25 x 20 cm, all as specified and directed by Engr-in-Charge. |
| 95 | Material and Labour for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated and inclusive of one primer coat one under coat and two finishing coats of aluminium paint, all as specified and directed by Engr-in-Charge. |
| 96 | Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all as specified and directed by Engr-in-Charge. |
| 97 | Supply and fix in repair following spare parts for out door type ring main units of various configuration complete all as specified and as directed by Engr-in-charge. |
| 98 | Ring LT/CT 30/1A, 2.5VA CL-5P10 |
| 99 | LT CT Resin cast iron type ratio - 100/1A, 2.5VA CL-1.0 |
| 100 | PT 22KV/Root 3/110V/ Root 3, 50 VA-CL-1/EE090562, 3 Phase |
| 101 | Auxiliary transformer 22KV/Rt3/230V, AC, 500VA |
| 102 | HT Fuse 22 KV/3.15A/EE090344 |
| 103 | CS FPI -earth fault indicator, E/F-10-100A, with 1NO+1NC, sensor-100-120mm dia with 3m wire, indicator model : CSFPI-E-A-H |
| 104 | 8 way battery and charger I/P 230V, O/P 24V DC, 10A (flat type) (12 V X02 battery) |
| 105 | Digital MFM meter flush mounted, size-96x96mm, AC, class 1.0, Aux-40-300V AC model elite 303, CT & PT ratio programmable with RS 485 port |
| 106 | O/C & E/F self powered relay-CSDPR-V2-300-D-L-N-M-C1 with modbus 1A, AUX supply-18-60V DC O/C minimum setting-10% & E/F- minimum setting-5% |
| 107 | Local Remote switch 3 Pole/2W/ EE090691 |
| 108 | PCI / 37302001-01 |
| 109 | LBS function motor UN2-30 24VDC / 37303017-01 |
| 110 | 9 micro switch kit /33111884-01 |
| 111 | Relay electm 24V DC 5A 4C /O/ 9423140 |
| 112 | Relay electm 230V AC 5A 4C /O/ 9423142 |
| 113 | Relay electm 4C/ O BASE / 9423230 |
| 114 | Push button flush type (Red) with carrier |
| 115 | Push button flush type (Green) with carrier |
| 116 | Contact element 1 NO green Cat Rb2-BE101 |
| 117 | Terminal block fuse type elmex model=KUDF4 |
| 118 | VCB function spring charging motor, 120W 24V DC, Type:PMR5 |
| 119 | Tripping coil |
| 120 | Closing coil |
| 121 | Micro limit switch, Model-D-38, rating-16A, 1 HP, 125/250V AC |
| 122 | Aux switch 6 NO + 6 NC |
| 123 | Pressure switch/ 33210204-01 |
| 124 | 10A, 230V AC 2 pole with on/off toggle switch, CAT : Kaycee |
| 125 | Material and Labour in repair GI pipe Light grade with all fittings complete laidin trenches/fixed on pole with suitable clamp all as specified for 80 mm bore of pipe for protection of UG cable, all as specified and directed by Engr-in-Charge. |
| 126 | Material and Labour in repair for Disc insulator porcelain vitreous brown 145 mm height & 225 mm dia ball and socket type two in series assembly with cast aluminium 4 U bolt tension hardware and tension clamps for conductors working pressure HT 22 KV complete all as specified and directed by Engr-in-Charge. |
| 127 | Material and Labour in repair for Pin insulator porcelain vitreous brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for 22000 volts grade 205 mm dia & 215 mm height, complete all as specified and directed by Engr-in-Charge. |
| 128 | Ditto- all as per item No 58.00 here-in-before, but Post type insulator. |
| 129 | Supply and install HT 22 KV Gang Operated Air Break Switch, horizontal 3 insulator type complete with handle, pipe and all mechanical fittings 400 Amps double break rotating type with earth switch, all as specified and directed by Engr-in-Charge.Make:- Atlas/Pactil /ABB / Crompton or equivalent as approved by the GE. |
| 130 | Material and Labour for overhauling i.e greasing, cleaning of GOD and adjustment of its operation complete all as specified and directed by Engineer-in-Charge. |
| 131 | Material and Labour for fixed type top contact for DO fuse units in replacement complete all as specified and directed by Engr-in-Charge. |
| 132 | Material and Labour for fixed type bottom contact for DO fuse units in replacement complete all as specified and directed by Engr-in-Charge. |
| 133 | Supply and Fix following spares of vertical type GOD 22 KV grade, 200 Amps rating in position as in repairs including testing after repairs:- |
| 134 | Male contact |
| 135 | Female contact |
| 136 | Tinned copper flexible jumper |
| 137 | MS Jumper carrier |
| 138 | Back connector plate |
| 139 | Supply and install HT 22 KV, 200 Amp outdoor type gang operated single break switch Tilting type vertical mounting consisting of hot dip galvanised channel iron base having 2 Nos 22 KV Post type insulator in stack and 3 stack per phase copper or copper alloy high pressure heavily tinned contacts plated MS arcing horns capable of breaking the magnetizing current complete with horizontal connecting square bar, GI pipe as down rod levers coupling & operating handle with locking arrangement, all as specified and directed by Engr-in-Charge. |
| 140 | Supply and install drop out lift OFF HT 22 KV, 200 Ampsfuse link consisting of channel iron base having 2 Nos 22 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385, complete all as specified and directed by Engr-in-Charge. |
| 141 | Material and Labour in repair Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed by Engr-in-Charge. |
| 142 | Material and Labour in repairs outdoor type, oil cooled, single phase, single pole wound primary, live tank OIP insulated current transformer dual core having ratio 120-60/1-1A (ratio change by means of tap on secondary winding) insulation Class A, burden 15 VA Class I for metering & 5P-10for protection complete all as specified and directed by Engr-in-Charge. |
| 143 | Supply and fix following spare partsof HT 22 KV SF-6, 800 Amps outdoor type circuitbreaker controlled by indoor panel, complete all as specified and directed by Engr-in-Charge :- |
| 144 | Limit switch with Bracket |
| 145 | Operation Counter Assembly |
| 146 | Carbon Brushes With Cap |
| 147 | Emery Pads |
| 148 | Auxiliary switch stack 5 NO+5NC |
| 149 | Door Gasket |
| 150 | Chemistic |
| 151 | Compound Gauge |
| 152 | Compound Gauge(small) |
| 153 | Anabond 680 (1 tube=100gms) |
| 154 | Local Remote switch 3 Pole |
| 155 | Trip Coil (single) -30V DC |
| 156 | Close Coil-30V DC |
| 157 | Set of Circlips, Split Pins ,Dowel Pins etc |
| 158 | Darina Grease(1 Packet= 250 Gm) |
| 159 | Torsion Spring Right |
| 160 | Torsion Spring Left |
| 161 | TNC switch 2 Pole |
| 162 | DC Contactor |
| 163 | Space heater 80 W |
| 164 | Thermostat |
| 165 | Spring Charging Motor |
| 166 | SF-6 Gas filling device with gas filling |
| 167 | Anti pumping device |
| 168 | Material and Labour in repairs \"T\" hard connector made of cast aluminium suitable for ACSR conductor complete all as specified and directed by Engr-in-Charge. |
| 169 | Material and Labour in repairs 4 \"U\" bolt hardware made of cast aluminium suitable for end disc insulator complete all as specified and directed by Engr-in-Charge. |
| 170 | Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 32mm x DOG conductor complete all as specified and directed by Engr-in-Charge. |
| 171 | Material and Labour in replacement Bi-metallic aluminium straight connector for C.T. 12mm x DOG conductor complete all as specified and directed by Engr-in-Charge. |
| 172 | Material and Labour in repairs brass spindlewith 32mm dia for CT\"s with Universal bushing complete all as specified and directed by Engr-in-Charge. |
| 173 | Supply and laying in repairs synthetic Rubber insulated mats 3 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-Charge. Makes :- ATLAS /Jyoti or equivalent as approved by the GE. |
| 174 | Disconnecting HT 22 KV grade XLPE cable of any size from structure/pole/transformer for finding fault by computer aided fault finding machine and locating exact location by thumping and necessary earth work to expose faulty cable piece and cutting faulty cable andtesting remaining cable with High voltage tester to withstand the cable as normal working pressure HT 22 KV complete all as specified and directed by Engineer-in-Charge.Note :- Excavation and earth work and Material and Labour for joints shall be measured and paid under relevant Item of schedule separately. |
| 175 | Labour only for upkeep of HT out door structure by removing grass, shrubs, trimming branches of trees near to structure removing cleaning, screening for mud etc and relaying of same stone aggregate complete all as specified and directed by Engr-in-Charge. |
| 176 | Supply and Fix Auxiliary High speed Master trip relay, Type AVAJH13 , contact 3 NO+2 NC HR , Auxiliary Voltage : 24 VDC or 110 VDC, all as specified and directed by Engr-in-Charge. |
| 177 | Supply and Fix 3 phase Over Current + Earth Fault Relay with High Set & RS-485 Port with IDMT and definite time characteristics, password protection, Aux supply (V) of 24-240V, AC/DC, Output contacts 4 No, all as specified and directed by Engr-in-Charge. Make : L&T or equivalent as approved by GE, CAT Part No.- MC61CNX4000, Model - MC61Cnx. |
| 178 | Preparation of old painted surface including removing old paint, rust, dust, oil, grease and any other foreign deposits by paint removers or burning off by blow lamps and cleaning with scrapers and chemicals for removal of rust for any number of coats, any width or girth & Material and Labour for application of aluminium paint one coat for 6 pole structure (steel or tubular) / channels/angles /GODs etc. all as specified and directed by Engr-in-Charge. |
| 179 | Ditto- all as per item No 80.00 here-in-before, but 4 pole structure |
| 180 | Ditto- all as per item No 80.00 here-in-before, but 2 pole structure |
| 181 | Supply, installation, testing and commissioning in repair HT 22 KV out door type, IP-66 protection factory fabricated feeder pillar box made out of 3.25 mm thick cold rolled MS sheet steel with double door and locking arrangement, duly painted with anti corrosive high quality post office red colour, suitable for 22 KV, 3 Phase, 50 Hz, 630 Amps, AC system to loop one incoming and one outgoing 3 x 120 Sqmm XLPE cable with all accessories complete all as specified and directed by Engr-in-Charge, comprising the following specifications :-(a)The HT feeder pillar shall have front and rear compartments, front compartment shall be connecting the terminals of cables and rear for terminations, Bakelite sheet 12mm thick shall provide for separation cable termination at front.(b)Adequate ventilation by means of louvers with wire mesh on both sides and at the top and bottom of feeder pillars.(c)Asbestos sheets of at least 6mm thick shall be provided on inside of all doors. (d)Enamelled name plate mentioning name of manufacturer, serial number and date of installation shall be displayed on front door.(e)Two Nos of earthing bolts shall be provided with the cubicle at front and rear side of feeder pillar.(f)Cable entry shall be from rear side of pillar.Removable gland plate of 10 SWG MS sheet shall be provided.Cable chamber shall be provided with perforated metal sheet separate for each chamber.(g)The set of bus bar 630 Amps rated shall be made up of electrolytic grade copper and provided with heat shrinkable PVC sleeve for RYB codes.(h)The insulating material used shall be Epoxy type insulator with uniform equally spaced rings, suitable for 33 KV class insulation.Make :-M/s Super Panel/Hupen/Switch Build Engg India Pvt Ltd/ Pune switch gears/SV Power System Mumbai or equivalent as approved by the GE. |
| 182 | Supply and Fix following spares of Horizontal type GOD 22 KV grade, 400 Amps rating in position as in repairs including testing after repairs, all as specified and directed by Engr-in-Charge :- |
| 183 | Male contact |
| 184 | Female contact |
| 185 | Copper rod/Plate |
| 186 | Copper Bare conductor of 4 SWG |
| 187 | Copper Bare conductor of 6 SWG |
| 188 | Material and Labour for DO fuse Element stranded silver/Tin coated copper wire soldered joint with ferrule and fire resistant tube type rating 2.5Amps complete all as specified and directed by Engr-in-Charge. |
| 189 | Ditto- all as per item No 85.00 here-in-before, but rating 5 Amps |
| 190 | Ditto- all as per item No 85.00 here-in-before, but rating 10 Amps |
| 191 | Ditto- all as per item No 85.00 here-in-before, but rating 15 Amps |
| 192 | Ditto- all as per item No 85.00 here-in-before, but rating 20 Amps |
| 193 | Ditto- all as per item No 85.00 here-in-before, but rating 30 Amps |
| 194 | Ditto- all as per item No 85.00 here-in-before, but rating 40 Amps |
| 195 | Ditto- all as per item No 85.00 here-in-before, but rating 60 Amps |
| 196 | Ditto- all as per item No 85.00 here-in-before, but rating 80 Amps |
| 197 | Ditto- all as per item No 85.00 here-in-before, but rating 100 Amps |
| 198 | Material and Labour for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations complete all as specified and directed by Engr-in-Charge. |
| 199 | Supply and filling in layers not exc 25cm thick with 40mm graded coarse aggregates in structures complete all as specified and directed by Engr-in-Charge. |
| 200 | Material and Labour for fixing of GI Nut and Bolts with washer of different sizes in HT structures complete all as specified and directed by Engr-in-Charge. |
| 201 | Material and Labour for self bonding electrical HT tape of size 1.9cm x 9.15m x 0.076cm for cable joints, transformers, HT structure joints, all as specified and directed by Engr-in-Charge. Make : 3M or equivalent as approved by the GE. |
| 202 | Material and Labour for HT lugs in the rectification of HT faults of size 95 Sqmm, all as specified and directed by Engr-in-Charge. |
| 203 | Material and Labour for HT lugs in the rectification of HT faults of size 120 Sqmm, all as specified and directed by Engr-in-Charge. |
| 204 | Material and Labour for HT lugs in the rectification of HT faults of size 150 Sqmm, all as specified and directed by Engr-in-Charge. |
| 205 | Material and Labour for HT lugs in the rectification of HT faults of size 185 Sqmm, all as specified and directed by Engr-in-Charge. |
| 206 | Material and Labour for HT lugs in the rectification of HT faults of size 185 Sqmm, all as specified and directed by Engr-in-Charge. |
| 207 | Material and Labour for Petroleum Jelly in HT Nut bolt joints, T- joints, U joints in CTs and PTs on the HT structure, all as specified and directed by Engr-in-Charge. |
| 208 | Supply only for HT gloves for 22 KV HT line, all as specified and directed by Engr-in-Charge. |
AI Tender Summary
Tender Timeline
Jan 25, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 22, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 24, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender