| 1 | Taking down old unserviceable BER ceiling fans in position and location under CVRDE Technical and Residential areas after disconnection of all electrical connections, dismantling of blades and stacking at site carefully and handover the same to MES store yard all as directed. Note : Quoted rate is deemed to be inclussive of loding, unloding and transportation of dismantled ceiling fans from site to MES store yardand no extra cost will be paid in this regard. |
| 2 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.Make:- Havells/ Orient/CromptonNote: Quoted rate is deemed to be inclussive of FRLS 3 core flexible copper conductor cable connected from ceiling rose to fan and other misc items required at site including testing & commissioning complete all as specified and as directed. |
| 3 | Wiring for light point/exhaust fan point/call bell point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A |
| 4 | Supply and Fix Exhaust fans 300 mm sweep, steel body with louvers, 230 Volts, single phase AC supply, including provn of opening by cutting the existing brick wall suitable for exhaust fan, 04 Nos bolts grouting in wall in PCC (1:2:4) using 12.5 mm graded stone aggregate for hanfing the fan and making good the disturbed surfaces with plaster and painting as per existing surfaces, fixing the fan by using suitable bolts, nuts and washers and connection to fan with suitable flexible twin core round copper wire complete. |
| 5 | Design Fabricating supply and erectingconnecting and testing totally enclosed LT cubicle panel board3 Phase 4 wire system Indoor typesingle door front openingtype, separate compartment for each control gear, cable alley, provision ofknock out type plates for various sizes of cables in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory madefabricated out of2.0 mm thick CRCA sheet duly treatedthrough 7 tank pre treatment process andpaintedwith epoxy powder coated mat finish ofGREY structural shade colour, built in industrial type locking arrangement , and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:645 CM below ground level and 15 Cm above ground level and consisting of following including taking down old LT panel of any type after careful disconnection of all electrical connections and making good the disturbed surfaces all as specified and as directed :- |
| 6 | Busbar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeveand mounted on suitable size of \"F\" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulatorsfor phases andneural set of 4 for RYB &N-01 set Incoming(a) Air Circuit Breaker, 4 Pole, 800 Amp, microprocessor based, drawout type, 50Hz , 415V, 50KA -01 No with Overload Protection, under voltage protection, earth fault system,and Cable termination with suitable cable gland and lugs.(b) Multifunctional Meter to read V, A, Hz, Kwh, Kvah etc -01 No(c) Indicator LED Type for RYB set of 3 - 01 setOut Goings(a) MCCB 4 Pole with handle, adjustable type, 400 Amp, 50Hz , 415V, 50 KA -01 Nos (b) MCCB 4 Pole with handle, adjustable type, 200 Amp, 50Hz , 415V, 36 KA -03 Nos (c) MCCB 4 Pole with handle, adjustable type, 125 Amp, 50Hz , 415V, 25 KA -02 Nos |
| 7 | (d) MCCB 4 Pole with handle, Fixed type, 63 Amp, 50Hz , 415V, 16 KA -02 Nos (e) MCB TPN 230 Volts 50 Hz 40 Amps - 03 No(f) MCB SPN 230 Volts 50 Hz 40 Amps - 03 No (g) Provn of Spare compartment for fixing of MCCB of capacity up to 250 Amps - 01 NoNote: Panel manufacturer should have in house powder coating plant with minimum 8 tanks pre-treatment of MS sheet facilities, dust free spray paint booth. (8 tanks pre-treatment process includes: degreasing / water rinsing/de-rusting/activation / phosphating /passivation).(b) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel.(c) In case of any deviation from approved drawing, the same shall be rejected and fresh LT panel shall be fabricated by the manufacturer. (d) All the electrical switchgear like MCCBs, MCBs and ACBs should be of same make.(e) Quoted arte is deemed to be inclussive of disconnection of all electrical connections from old panel and refixing to the new panel by providing clable glands and lugs required at site and testing. |
| 8 | Design Fabricating supply and erectingconnecting and testing totally enclosed LT cubicle panel board3 Phase 4 wire system Indoor typesingle door front openingtype, separate compartment for each control gear, cable alley, provision ofknock out type plates for various sizes of cables in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory madefabricated out of2.0 mm thick CRCA sheet duly treatedthrough 7 tank pre treatment process andpaintedwith epoxy powder coated mat finish ofGREY structural shade colour, built in industrial type locking arrangement , and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Angle iron frame of suitable size duly painted and embedded in PCC 1:3:645 CM below ground level and 15 Cm above ground level and consisting of following including taking down old LT panel of any type after careful disconnection of all electrical connections and making good the disturbed surfaces all as specified and as directed :- |
| 9 | Busbar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeveand mounted on suitable size of \"F\" class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulatorsfor phases andneural set of 4 for RYB &N-01 set Incoming(a) Air Circuit Breaker, 4 Pole, 630 Amp, microprocessor based, drawout type, 50Hz , 415V, 50KA -01 No.with Overload Protection, under voltage protection, earth fault system,and Cable termination with suitable cable gland and lugs.(b) Multifunctional Meter to read V, A, Hz, Kwh, Kvah etc -01 No.(c) Indicator LED Type for RYB set of 3 - 01 setOut Goings(a) MCCB 4 Pole with handle, adjustable type, 200 Amp, 50Hz , 415V, 50 KA -03 Nos(b) MCCB 4 Pole with handle, adjustable type, 100 Amp, 50Hz , 415V, 25 KA -02 Nos (c) MCB TPN 230 Volts 50 Hz 40 Amps - 03 No |
| 10 | (d) MCB SPN 230 Volts 50 Hz 40 Amps - 03 No (e) Provn of Spare compartment for fixing of MCCB of capacity up to 100 Amps - 01 NoNote: Panel manufacturer should have in house powder coating plant with minimum 8 tanks pre-treatment of MS sheet facilities, dust free spray paint booth. (8 tanks pre-treatment process includes: degreasing / water rinsing/de-rusting/activation / phosphating /passivation).(b) Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel.(c) In case of any deviation from approved drawing, the same shall be rejected and fresh LT panel shall be fabricated by the manufacturer. (d) All the electrical switchgear like MCCBs, MCBs and ACBs should be of same make.(e) Quoted arte is deemed to be inclussive of disconnection of all electrical connections from old panel and refixing to the new panel by providing clable glands and lugs required at site and testing. |
| 11 | Supply and Fix 4 way (4+12 Double door horizontal type 3 pole and neutral sheet steel MCB distribution board 415 Volts on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder pinted including earthing etc as required (with out MCCB/MCB/RCCB/Isolator). |
| 12 | Supply and fixing 5 Amps to 32 Amps rating 415 Volts 10 KA \"C\" curve MCB suitable for inductive load of Triple pole and neutral (TP&N) in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 13 | Supply and fixing 5 Amps to 32 Amps rating 240 Volts 10 KA \"C\" curve MCB suitable for inductive load of Single pole (SP) and neutral in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 14 | Wiring for circuit/submain wiring along with earth wire with the 4 X 4.0 Sqmm + 2 X 2.5 Sqmm as earth wire of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required |
| 15 | Wiring for circuit/submain wiring along with earth wire with the 2 X 2.5 Sqmm + 1 X 2.5 Sqmm as earth wire of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required |
| 16 | Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc with charcoal coke and salt as required |
| 17 | Taking downold unserviceable Steel tubing and connections of any size up to 40 mm bore from Trenches/ walls/floors etc complete all as specified and as directed. |
| 18 | Taking downold unserviceable Steel tubing and connections of any size of 50/80 mm bore from Trenches/ walls/floors etc complete all as specified and as directed. |
| 19 | Providing and fixing GI pipes 25 mm dia complete with GI fittings including trenching and refilling external work etc. |
| 20 | Providing and fixing GI pipes 40 mm dia complete with GI fittings including trenching and refilling external work etc. |
| 21 | Providing and fixing GI pipes 50 mm dia complete with GI fittings including trenching and refilling external work etc. |
| 22 | Providing and fixing GI pipes 80 mm dia complete with GI fittings including trenching and refilling external work etc. |
| 23 | Providing and fixing G.I. pipes 20 mm dia complete with G.I. fittings and clamps, i/c cutting and making good the walls etc |
| 24 | Providing and fixing Gunmetal gate valve 50 mm with CI wheel of approved quality (screwed end) |
| 25 | Providing and fixing Gunmetal gate valve 40 mm with CI wheel of approved quality (screwed end) |
| 26 | Providing and fixing Gunmetal gate valve 25 mm with CI wheel of approved quality (screwed end) |
| 27 | Providing and fixing Gunmetal gate valve 20 mm with CI wheel of approved quality (screwed end) |
| 28 | Providing and fixing Gun metal non return valve of size 50 mm approved quality (Screwed end) including old taking down. |
| 29 | Making connection of GI distribution branch with GI main of 25/40 mm bore pipe by providing and fixing Tee, including cutting and threading the pipe complete etc. |
| 30 | Making connection of GI distribution branch with GI main of 50/80 mm bore pipe by providing and fixing Tee, including cutting and threading the pipe complete etc. |
| 31 | Material and Labour for making cross hole suitable for 50/80 mm dia bore pipe below the bitumin/cement/hard stand road with the help of pressure pipe/boring tools for passing the GI pipe 50/80 mm dia and exceeding 100 Mtr from work site all as directed. |
| 32 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 33 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil |
| 34 | Retruning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed. |
| 35 | Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed. |
| 36 | S & F GI Tubing Med Grade, ISI marked, fixed to wall & ceilings or laid on floor complete with all fittings and connection to existing water mains as directed of size 25 mm bore. |
| 37 | S & F GI Tubing Med Grade, ISI marked, fixed to wall & ceilings or laid on floor complete with all fittings and connection to existing water mains as directed of size 20 mm bore. |
| 38 | S & F gunmetal gate valve / globe valve with iron wheel head screwed both ends for iron pipes and testing all as specified and as directed complete of size 25 mm dia |
| 39 | S & F gunmetal gate valve / globe valve with iron wheel head screwed both ends for iron pipes and testing all as specified and as directed complete of size 20 mm dia |
| 40 | M & L for cutting existing galvanized iron water supply pipe line up to 80 mm dia for inserting suitable size GI Tee and socket of size up to 25 mm dia for taking branch connection. |
| 41 | M & L for making cross hole suitable for 40/50 mm dia bore for passing through the 25 mm dia GI pipe below the RCC/ Bituminious road/ pavement |
| 42 | Supply and fix rotational moulded polyethyiene water storage tanks 1000 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified. |
| 43 | Supply only Calcium hypo chlorite Granules packing size ne less than 45Kg , 65-95 concentration complete all as specifed and directed. |