| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP-A |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for circuit/ sub main wiring along with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core flexible cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 1.5 sq. mm |
| 7 | 4 sq. mm |
| 8 | 6sqmm |
| 9 | 4x10sqmm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 20mm |
| 12 | 25mm |
| 13 | 32mm |
| 14 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 15 | 1 or 2 Module (75 mmX75 mm) |
| 16 | 3 Module (100 mmX75 mm) |
| 17 | 6 Module (200 mmX75 mm) |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 19 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 21 | 5/6 A switch |
| 22 | 3 pin 5/6 A socket outlet |
| 23 | Supplying and fixing 5 stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (2M) |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 25 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door(Make- Legrand/L&T/Hager) |
| 26 | Supplying and fixing following rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/Siemens/ L & T) |
| 27 | 63 Amp 4 pole isolator |
| 28 | 63 Amp 4 pole MCB |
| 29 | 6-32Amps Single pole |
| 30 | Blanking plate |
| 31 | Supply and fixing of 20 watt,65000K LEDBatten suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells/Phillips /Crompton) |
| 32 | Supply and fixing of the following type lamp holders /lamps i/c connection, testing etc. as required. |
| 33 | Polycarbonate Angle Holder |
| 34 | 14/15 watt LED lamp suitable for B22 holder |
| 35 | Supply and Fixing of 30 watt new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07along with fixing bracket made of 32/40mm dia medium class GI pipe with clamps i/c connection, testing etc. as required. |
| 36 | Supply and Fixing of1200mm sweep superior quality Ceiling fan suitable for operation on 230 volts 50Hz, AC supply, connection, testing etc. complete as required. (Make- Havells: Pacer / Usha Striker)/Equivalent) |
| 37 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing RCC ring of 300 mm dia and 450 mm depth enclosure with RCC cover plate having lifting arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 38 | Supply and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 39 | Supply and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 40 | Supply and fixing of earth bus of 50 mm x 5 mm GI strip on surface above suitable size insulators, drilling holes for connections etc. complete as required. |
| 41 | Providing and fixing 6SWG dia G.I. wire on surface / recess for loop earthing as required. |
| 42 | Supply of the following sizePVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988i/c transportation etc. as required. |
| 43 | 4 core 16 sqmm |
| 44 | Laying of 4X10sqmm/ 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable in Air etc. as required. |
| 45 | Laying of 4X10sqmm/ 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable on surface of wall with GI saddles etc. as required. |
| 46 | Laying of 4X10sqmm/ 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable Directly in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 47 | Laying of 4X10sqmm/ 4X16sqmm / 4X25sqmm XLPE/PVC insulated Aluminium conductor armoured cable in existing GI pipe etc. as required. |
| 48 | Supplying and making end termination for 4X16sqmm / 4X10sqmm / 4X25sqmm Al. cond. Armd. Cable withbrass compression glands and al. sockets/lugs etc. as required. |
| 49 | Supply and laying of 40mm dia medium class GI pipe as per the following manner etc. as required. (make -Jindal/Tata/OSWAL) |
| 50 | In ground below 600mmby excavating and refilling the soil |
| 51 | On surface with GI strip clamps |
| 52 | Supply and Fixing of 63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) . |
| 53 | Disconnection of power supply connections of EB and DG power supply cables and removing theDG set, Electrical panel, Distribution boards i/c earth strips/wires etc. as required. (At old foundation) |
| 54 | Dismantling of 2 Nos. SAC units (indoor and outdoor units) along with copper refrigerant pipes etc, old light fittings, TPN MCBDB etc., closing theholes in wall and making good the damages and cleaning the rooms etc. as reqd, |
| 55 | Shifting of the 15 KVA DG setfrom the existing foundation at old location to new location at Phiringiaincluding loading and unloading by means of hydra/crane etc. as required. |
| 56 | Testing and commissioningof the existing 15 KVA canopy DEAset with all of its accessories & re-connection of power cable from Alternator to panel/ feeder panel etc. complete as reqd. |
| 57 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lifting upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 58 | Providing & laying in position cement concrete 1:2:4(1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size) in foundation of Pump , DG Set including form work etc as reqd. |
| 59 | Centering and shuttering including strutting, propping etc. and removal |
| 60 | Providing 20 mm thick cement plaster of mix (1 cement : 4 fine sand) at all levels with neat cement finishing etc as reqd. |
| 61 | S/F of 40mm x 40mm x 5mm MS angle frame around the existing P.C.C foundation i/c cutting, welding, painting with two coats primer & grey paint of approved shed etc as reqd. |
| 62 | Supply and laying of 2.0mm thick Rubber mat as per IS 15652:2006 having High electrical insulation resistance, 100% shock proof, fire retardant, moisture proof, washable type suitable for providing at electrical panels etc. as required. (Make- ISI) |
| 63 | Supplying of 9.5 Litre capacityMS bucket with conical pointed, painted in post office red colour with prior coat of red-oxide paint and written with white paint \"FIRE\" and mounted on existingangle iron frame with bracket of appropriate size & capacity including filling of sand etc. (one set comprising of 3 units). |