| 1 | Renewal/ replacement of asbestos cement roof/velley gutter with galvalume sheets including North light glasses, North light curves, rain water pipes of rolling mill at O.F. Katni. |
| 2 | Dismanteling of asbestos cement (corrugated, semi corrugated etc.) sheets including ridges in roof covering complete all as specified and directed. |
| 3 | Dismanteling plain or corrugated steelsheeting any gauge, thickness, including Nainital or semilar pattern roof covering complete all as specified and directed. |
| 4 | S & F, painted aluminium zinc coating GI based corrugated steel sheet 0.60 mm of any colour having tensile strength of 550 Mpa as in roof & north light covering/cladding to wall, fixed with self tapping screws as specified. |
| 5 | S & F fibre glass reinforced translucent corrugated sheeting with two corrugation side lap with coach screw & washer in roof, wall etc. of 2 mm thick. Fixed with L-type or J-typeor cranked hook bolts in liew of screw. |
| 6 | S & F of roofturbo airventilator 24\"/600mm throat outer 510 mm dia top bottom ring S S 304, 0.5 mm thick aluminium blade of 42 Nos. fins and FRP based as per roof profile sheet 1.5 to 2mm thick 1800 mm length and 1080 mm width (premoulded transperent) and fixing over roof sheet of industrial building of heightmore than 15.00 mtr. complete all asspecified and directed. |
| 7 | S & F, prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.60 mm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. ( Note - The self driven screw shall be adequate length to driven in to complete thickness of purline/raft etc and to be provided with oone biyumen washer and the gap if ant shall filled with silicon gel to avoid any leakage). |
| 8 | S & F plain, galvanised mild steel sheeting, in ridges, hips, velley gutters, drip and straight flashings (length and girth as fixed) of class 3 of 1.00 mm thick welded or soldered joints are provided. |
| 9 | Fixing only galvanised corrugated mild steel sheeting with two corrugation side lap with coach screw & washer in roofs, walls etc with grade of zinc coating 275 of 0.63 mm thick. |
| 10 | S&F Galvanised corrugated mild steel sheeting with two corrugation side lap with coach screw & washer in roofs, walls etc with grade of zinc coating 275 of 0.63 mm thick |
| 11 | Dismantling mild steel work of any description not otherwise provided for including removing the dismantled material of the site complete all asspecified and directed. |
| 12 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters embeding in concrete andscrewing etc. wind ties for roof including securing bolts; and posts and struts in fencing including cutting , cutting tops to shape as directed, drilling holes,notching for wire etc. flat iron filets (for securing wire mesh etc.) including all necessary drilling, bolting or rivetting etc. and similar work confirming to Fe-290 Gde-E-165. |
| 13 | M & L for preparation of new steel surface of any description, n exc 10cm in width or girth priming with red oxide (one Coat) and applying synthetic enamel paint (Two Coats) all as specified and directed. |
| 14 | M & L for preparation of old steel surface of any description, n exc 10cm in width or girth and applying synthetic enamel paint (one Coat) all as specified and directed. |
| 15 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones omplete all as specified and directed. |
| 16 | Fixing/Recuring of hacked glass exc. 0.5 but n.exc. 0.75 Sq.m.in the same position with complete fittings all as directed |
| 17 | M&L for rough cast, wired glass 6.4 mm thick (exc 0.5 Sqm ) and glazed with oil putty in square complete all as specified and directed |
| 18 | Taking down asbestos cement pressure pipes (150mm dia), any class (including all fittings) including disconnecting pipes and fittingscomplete all as specified & directed. |
| 19 | S&F high density polytheline pipe (HDPE) 150mm dia, PN 10 including all fitings like bends, elbow, T, shoes, etc fixed complete all as specified & directed |
| 20 | M&L rendering 10mm thick on fare faces on concrete surfaces in CM (1:4) finished even and smooth (without using extra lime or cement). |
| 21 | M&L for preparing of new decorated wall surfaces including cornices plasteres etc, and applying two coat of oil bound distemper over a coat of chalk whitig ( oil emultion ) on wall surfaces allas specified and directed. |
| 22 | M&L preparation of old painted surfaces of steel and applying two coat of aluminium paints on steel surfaces over 10 cm width or girth complete all as specified and directed |
| 23 | M&L PCC type B1 (1:2:4) using 20mm graded aggregate as in copping, filling gaps between roof sheetingand walls etc. complete all as specified and directed |
| 24 | specialElectircal repairs to lightning protection & roof lightof EXTRUSION section at O.F.Katni (from Sl.No. 1.18 to 1.27). Lightning protection & roof light:- Taking out old unserviceable air terminal rod any size/any type complete all as directed. |
| 25 | dismentlingand taking out old unservisable GI/aluminium strip of any size complete all as directed. |
| 26 | M& L Air termination, single pointed aluminium rod 12mm dia and 300mm long. |
| 27 | M&L Aluminium strip 25 x 3.15mmwith saddles and fixingscrews etc. for roof conductors and down conductors above ground. |
| 28 | M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw. |
| 29 | M&L Galvanised iron strip 32 x 6mm buried in ground. |
| 30 | SUPPLY and fixing of GI pipe40mmdia for fixing ait termination on roof . |
| 31 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses,pendants, regulators sockets etc. to beseparately), removing materials to store for keepingmeasured in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. |
| 32 | M&L-One light point or one fan point controlled by one switch with cables 1.5 sq.mm size -Wiring with copperconductor cables FRLS In stove enamelled Steel Conduit,PVC rose or connector, socket outlet, lamp holder, switchsingle core unsheath cable.(I) The rates for point wiring include:(a) Supplying and fixing/drawing of cables for carrying out wiring of a circuit of any length from thedistribution board or iron clad switch unto ceiling or fan regulator including additional length fromconnector to lamp holder (in case of stiff pendantpoints and water tight bracket points) and back plate to lamp holder (in case of plain bracket points). (b) Supplying and fixing in case of conduit casing & caping wiring all conduits/casings & capings(separate conduits/caring & capings for individual conduit casing caping circuits) or conduit casingdcaping fittings and accessories, joint boxes, terminal boxes for mounting or housing switches, socketoutlets, fan regulators, etc. and continuous earthingand earthing connections, all as specified.(c) Supplying and fixing wood battens, bends, corners,filters, tee-pieces, etc. required for wiring on battens. (d) Supplying and fixing all accessories such as screws,clips, plugs, clamps, etc. as specified for securing cables, battens, conduits etc. to walls, steel joists etc. (e) Supplying and fixing PVC or steel conduits for mechanical protection of cables as specified. (f) Supplying and fixing bushed conduits or porcelaintuning, as specified, for wiring to pass through walls, floors etc.(h) Supplying and fixing joint or junction-boxes and connecting the same as ordered in case of batten wiring. (j) Supplying and fixing earth wire and earthingconnections, as specified, including all accessories required for the same. (k) Supplying and fixing/drawingfor each individual circuit from the distributionseparate neutral wire board (or iron clad in lieu). (I) Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through joints and making good all disturbed work to match the existing. (m) Shellac varnishing as specified, to wood battens, wood blocks and other wood fittings and fixtures. (n) Painting of battens and cables or surface conduitsalongwith the painting of walls. (o) Testing, as specified. |
| 33 | supply only LED HIGH BAY LIGHT 150 WATT,CEILING SUSPENSION,COLOR TEMP- 4500K TO 5500K,IP-55,OPTIC LENS,SYSTEM EFFICACY->/= 120,P.F. >/=0.95,VOLTAGE RANGE-160 TO 265VOLT,SURGEPROTECTION>/=5KV (INTERNAL),SURGEPROTECTION>/=10KV (EXTERNAL),WARRNTY-24MONTH AS PER IS:16106:2012 OR LATEST,IS:16105:2012 LATEST. |
| 34 | fixing only LED HIGH BAY LIGHT 150 WATT. |
| 35 | Schedule of Credit |
| 36 | Old AC Sheet |
| 37 | Scrap Iron |
| 38 | AC Pipes |
| 39 | Oild CGI / PGI Sheet |