| 1 | Dismantling of old light fitting, old unused power cable, old unused air curtain, old unused LT panel i/c shifting the materials in store/safe area in the same campus of TE building etc. complete as required. |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 3 | Group C |
| 4 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 5 | 1 x 1.5 sq. mm |
| 6 | 2 x 1.5 sq. mm |
| 7 | 2 x 2.5 sq. mm |
| 8 | 3 x 2.5 sq. mm |
| 9 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 10 | 5/6 amps switch |
| 11 | 3 pin 5/6 amp socket outlet |
| 12 | 15/16 amp switch |
| 13 | 6 pin 15/16 amp socket outlet |
| 14 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 15 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 17 | Upto 35 sq. mm |
| 18 | Supply of 3.5x35 sqmm aluminium conductorPVC insulated and PVC sheathed armored power cable etc complete from changeover to meter board/DB/LT panel as required.(Havells/Polycab or SS make) |
| 19 | Providing and fixing meter board of size 600mm x 450mm fabricated out of ms angle iron frame of size 25x25x3 mm thick and 9 mm thick bakelite sheet and 3 nos 100 Amp kit kat fuses and neutral link i/c painting of angle iron, grouting and making good the same complete as reqd. |
| 20 | Providing and fixing of 100 Amp TPN SFU with HRC fuses in sheet steel enclosure suitable for operation on 415 volts AC supply alongwith suitable size ms angle iron frame , paintingi/c earthing the body etc as reqd. (M/s L and T make FN-63 or S/S make) |
| 21 | Providing and fixing of 100 Amp four pole ON load changeover switch with sheet steel enclosure suitable for operation on 415 volts AC supply alongwith suitable size ms angle iron frame, painting etc i/c earthing the body etc as reqd. (M/s HPL socomec or ss make) |
| 22 | Repairing of existing wiring and other miscellaneous items of AFD systemi/c S/F of copper wire, lugs/ferrules,connectors etc and testing of complete system etc complete as required. |
| 23 | Repairing/replacement of following faulty accesseries in AFD system i/c connection and testing etc as required(Approved make of BSNL) |
| 24 | Control card |
| 25 | Zone card |
| 26 | 20 Watt Hooter |
| 27 | Supplying and fixing of sealed maintenance free 7AH 12 volt battery for fire control panel etc. complete as required.(makeExide / Amron / Amar raja or S/S make) |
| 28 | Supplynad fixing of street light fitting LED 50 Watt on the wall with suitable size of MS pipe (Round) i/c connection with 2x1.5 Sqmm PVC flexible copper wire etc complete as required. (Havells 50 Watt Superb Street light LHEXAYP7PN6K050 or SS Make ) |
| 29 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 30 | 3.5 X 35 sq. mm (32 MM) |