Tender For Construction Of Access Control Room Under Wp 19 For Naob Rambilli Visakhapatnam
Tender Overview
Project Description
Tender For Construction Of Access Control Room Under Wp 19 For Naob Rambilli Visakhapatnam
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Mar-2025 | Postponement2 | Date | 24-Mar-2025 |
| 2 | 13-Mar-2025 | Revised BOQ | BOQ | 24-Mar-2025 |
| 3 | 21-Mar-2025 | Postponement3 | Date | 02-Apr-2025 |
| 4 | 02-Apr-2025 | Postponement4 | Date | 15-Apr-2025 |
| 5 | 21-Feb-2025 | Postponement1 | Date | 21-Mar-2025 |
| 6 | 15-Apr-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-Apr-2025 |
BOQ
| Sl. No. | Item Description |
| 1 | Lump sum amount worked out by the contractor for \"BUILDINGS & STRUCTURES\" as listed in Schedule \"A\" Part-I on Serial Page No. |
| 2 | Lump sum amount worked out by the contractor for \"SITE CLEARANCE / AREA DEVELOPMENT / EARTH WORK EXCAVATION\" as listed in Schedule \"A\" Part-II on Serial Page No. |
| 3 | Lump sum amount worked out by the contractor for \"INTERNAL ELECTRIFICATION\" as listed in Schedule \"A\" Part-III on Serial Page No. |
| 4 | Lump sum amount worked out by the contractor for \"EXTERNAL ELECTRIFICATION\" as listed in Schedule \"A\" Part-IV on Serial Page No. |
| 5 | Lump sum amount worked out by the contractor for \"PATH / HARDSTANDING\" as listed in Schedule \"A\" Part-V on Serial Page No. |
| 6 | Schedule \"A\" Part - VI: [Miscellaneous Items] [Internal Electrification, External Electrification andAir Conditioning]: [To be quoted by the bidder.] |
| 7 | M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light / fan point controlled by one one way switch, complete all as specified and as directed.Note: Cutting chases and making good surfaces shall be included in the unit rate. |
| 8 | Description all as per Serial Item No. 6.01 here-in-before but with 2.5 Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 3 pin 5 Amp switch socket point, on independent board, complete all as specified and as directed. |
| 9 | Description all as per Serial Item No. 6.01 here-in-before but with 4.0Sqmm copper conductor cable and 4.0Sqmm cable as earth continuity conductor for5/15Ampsocket point/security light point controlled by one switchd, complete all as specified and as directed. |
| 10 | M&L sub main wiring with four single core PVC-FRLSH insulated unsheathed multistranded copper conductor cable of size 4 sqmm drawn in new/existing conduitwith 4 Sqmm PVC-FRLSH insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified and directed. Note : (i) four single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 11 | M&L sub main wiring with four single core PVC-FRLSH insulated unsheathed multistranded copper conductor cable of size 6 sqmm drawn in new/existing conduitwith 6 Sqmm PVC-FRLSH insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified and directed. Note : (i) four single core cable and one run of earth copper conductor will be measured and paid as one unit length |
| 12 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 25 mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item. |
| 13 | All as per Serial Item No. 6.06 here in before but using galvanised iron strip 32 x 6mm earthing lead and 50mm bore GI pipe medium grade as protection pipe. . |
| 14 | Supplyinstall and testing ofFeeder piller box (Out door) cubical type, floor mounted fabricated out of 3 mm thick CRCAsheet and front opening door with locking arrangementand painted epoxy powder coated paint with suitable aluminium bus bar of 1200 Amps capacity for 3 phase ,4 wire system, 415V ,having seprate compartments for each swich gear, metering equipment, CT coils etc complete and also provision for two spare compartments suitable for 250 A capacity MCCB complete with the following :-Incoming :-(a) ACB 4 pole, 800 Amps 65 KA breaking capacity- 01 I/C Outgoing :-(a) MCCB 4 pole, 250 Amp 50 KA - 02 O/G(c) MCCB 4 pole, 160 Amp 36 KA - 03 O/G(d) MCCB 4 pole, 100 Amps 36 KA-03 O/G(e)Time switch-01 (f) Suitable capacity of contactors, kitkat switches, toggle switches, connectors timers, relays, time clock (Analog ) shall be consideredNote : Pillar box shall be CPRI approved, ICU = 100% ICS , complete all as specified and as directed. |
| 15 | Supply and fix cable jointing kit for 1100 volt grade cable for straight through joint complete with jointing material (epoxy based) and accessories suitable for 3.5 XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed. |
| 16 | Supply, install, testing and commissioning of Hi Wall Split type Inverter type Air conditioner with indoor / outdoor units with cordless remote control unitwith battery (suitale size) Summer Cool / Turbo Cool and with in-built HD Filters / advanced Air Ioniser and Plasma filter, copper winding compressor, copper condensorfor better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 TRcomplete all as specified and directed by the Engineer-in-Charge.(Note :-1. The quoted rate is deemed to include of GI bracket of suitable size for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge. 2. Copper tube of suitable size and length (for each ACs), Drain water PVC pipeofsuitable size and length (for each ACs) , copper cables of suitable size upto outdoor unit shall be included in quoted rate. 3. Provision of passing of indoor/outdoor pipe from wall / core cutting in any type of wall are included with quoted rate.) |
| 17 | S&F Voltage stabilizer of capacity 4KVA, for automatic operation, suitable for 1.5 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed. |
| 18 | M & L forsingle pole and neutral metal clad enclosure with 3 pin and earth plug and socket complete with single pole MCB of capacity 20-32 Amps, 240V complete all as specified and as directed. |
| 19 | M & L for sub main wiring 2 runs of single core 6 Sqmm for main wire and 01 RUN of single core 6.0 Sqmm as earth wire of standard copper conductor FRLS PVC insulated unsheathed cables confirming to IS : 694 drawn through and including concealed in wall/wooden panelling rigid medium duty unplasticised PVC conduit confirming to IS : 9537 (part- 3) and ISI mark not less than 25mm dia and accesssories all confriming to IS specifications complete all as specified and directed.Note : Two runs of main wire, one RUN of earth wire and PVC conduit shall be measured as one run. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.