| 1 | Demolition of brick/precast concrete block walling built in cement mortar, complete all as directed. |
| 2 | Dismantling structuralsteel workincluding doors, gates etc, complete all as specified and directed. |
| 3 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in hard and dense soil. |
| 4 | M & L for PCC 1:3:6 type D-2 (using 40mm graded stone aggregate ) as in foundation filling or mass concrete, complete all as specified and directed,. |
| 5 | M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter completeall as specified and directed. |
| 6 | M&L for Form work formwork to sides of pillars, posts, struts, piers,columns and stanchions, completeall as specified and directed. |
| 7 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping forcolumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 8 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and directed. |
| 9 | M&L for RCC nominal mix 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 10 | M&L for RCC Nominal mix 1:2:4 type B1(using 20mgraded crushed stoe aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 11 | M&L for RCC 1:2:4 type B1(using 20mgraded crushed stoe aggregate) as in beams, RCC bems lintels etc, complete all as specified and directed. |
| 12 | M&L forprecast cement concrete block (1:2:3 type C1, using 20mm graded crushed stone aggregate)masonry with solid blocks, exc. 10 cm in width and setting in mortar1:6, complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering in cement mortar 1:6 on concrete surfaces of wall, finished the surface even and fair, complete all as specified and directed. |
| 14 | Preparation of new plastered surfces of wall and applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 15 | Dismantlimg pre-cast RCC fencing post or struts embedded in concrete (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 16 | Dismantling barbed wire fencibg in any description and an position including making coil, complete all as directed. |
| 17 | Excavation in hard and dense soil as in post hole (or similar holes) each n.exc 0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil to a distance n.exc 50m and making good the disturded surface, complete all as specified and directed. |
| 18 | S&F 75x75x6mm angle iron as in fencing post, incl cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mess) incl all necessary drilling , bolting or reveting etc. |
| 19 | M&L 40x6mmFlat iron as inties , incl cutting tops to shape as directed, drilling holes, notching for wire etc, |
| 20 | M&L for mild steel round bars 10mm dia and over cut to length bent to shape required and fixing as required in fencing of Fe-410 W(gde-E-250) quality A or Fe 290 (gde-E-165). |
| 21 | Supply only chain link MS galavanised fencing as specified |
| 22 | Fixing only chain link fencing including line wires, and mesh size type of stadrads, rail straining bots etc size of mess 100x100mm 4mm dia wire, complete all as directed. |
| 23 | S&F galvanised 2 str and steel barbed wire 2.24mm dia barbed with 2mm dia bars and 75mm spacing and straining and fixing to any type of standard rails straining bold, inc securing or typing at crossing with galvanised mild steel wire staples or steel pins (each line wire to be measured ) |
| 24 | S&F MS bolts machine made with hexagonal or square head one end and screwed the other or screwed both end n.ext 5 cm long, 12mm dia. |
| 25 | M&L Two coat of synthetic enamel paint to steel surface over a coat of red oxide primer n exc 10 cm width or girth incl preparation of new surfaces, ccomplete all as sprcified and directed |
| 26 | M&L Two coat of synthetic enamel paint to steel surface over a coat of red oxide primerexc 10 cm width or girth incl preparation of new surfaces, |
| 27 | M&L for preparing surfaces of steel and iron work newof any description and girth at treated area n.exc .5 sq each and treated with Tar/ Coal tar black paint |
| 28 | M&L 10mm thick cement plaster in cement mortar 1:4 on fair faces ofconcrete surfaces and finished surface even and fair, complete all as specified and directed. |
| 29 | S&F for granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed. |
| 30 | M&L for wall clading colour ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 31 | M&L for preparation of old painted Surfaces of any description, n.exc 10cm in width or girth and applying one coat of aluminium paint complete all as specified and directed. |
| 32 | Removal of excavated soil to a distance exc.50 Mtr and n.exc. 150 Mtr and deposited as directed by Engineer-in-Charge. |
| 33 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard/dense soil. |
| 34 | S&F Mild steel framed work such as grills, gratings, as for ornamental and intricate design gates side hung,includingpintlehinges, stops, hand-made sliding bolts, etc confirming to Fe-290, Gde-E-165, complete all as specified and directed. . |
| 35 | Demolition of cement concrete (unreinforced) of any description including (below or above ground level), not exc. 15 cm thickness, including removal of rubbish from site, complete all as specified. |
| 36 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard and dense soil, complete all as specified and directed. |
| 37 | M&L for Hardcore of gauge n exc. 63 mm broken stone or boulders , deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all specified and directed |
| 38 | M&L for 100mm thick, plain cement concrete 1:4:8, type D-2, using 40 mm graded mechanically crushed stone aggregates,as in sub-basecomplete all as specified and directed. |
| 39 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, complete all as specified and directed. |
| 40 | M&L for Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4for laying floor finishes, completed all as directed. |
| 41 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade and pointed with grey cement and no pigment, complete all as specified and directed. |
| 42 | M&L forsand filling under floors as in cushioning to interlocking paver block, complete all as specified and directed. |