Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-02-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-02-2025 |
| Sl. No. | Item Description |
| 1 | Supply and fixing in repairsmoulded (FRP) junction boxwith IP 65 protection of size 300x200x105 mm with 32 Amp 4 way heavy duty terminal block with 6 Amp MCBSP and two number of cable entry gland of standard size with suitable MS clampto fix with pole complete all as specified and directed |
| 2 | Supply and fixing in repairs for Sub Main wiring using FR Insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing. drawn through rigid PVC conduit 20 mm dia with clamps forfixing on pole for connection from junction box to light fittings / switch complete all as directed.NOTE:Two runs of cable for phase / neutral and one run of cable for earth including conduit will be measured and paid as one unit length. |
| 3 | S&F in repairs GI Pipe Bracket made out of Galvanised Iron tubing40mm bore (dia), light grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including clamps, complete all as specified and as directed. |
| 4 | Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre below normal ground level connectedwith and including GI strip of size 32x 6 MM by means of bolts and nutscheck nut and washer of galvanized iron with & including PCC pit in PCC 1:2:4 type B-1, precast RCC cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 7.5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point, and testing on completion including taking down old unserviceable earthing, complete all as specified and directed.NOTE :- (i) RCC pit cover shall be pre cast of RCC (1:2::4) type B , 80 mm thick reinforcement with 8 mm TOR steel @ 100 c/c in lieu of CI cover and the rate included in the unit rate . (ii) Earth electrode shall be protected upto test point using necessary arrangement with suitable size GI pipe and the rate included in the unit rate.(iii) Earth pit Cover shall be painted in Red paint over a primer and the rate included in the unit rate. |
| 5 | S&F in repairs Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 150 Watt, complete all as specified and as directed. Make: Philips/Havells/ Crompton Greaves/ Wipro/Bajaj/Surya as per Light Fittings MAKE available at Site of Work. |
| 6 | All as item no 5 above butfor LED Light Fitting of capacity 100 Watt. |
| 7 | All as item no 5 above butfor LED Light Fitting of capacity 60/72/75 Watt. |
| 8 | All as item no 5 above butfor LED Light Fitting of capacity 45 Watt. |
| 9 | Supply and fixing LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed. Make: Bajaj Cat No. BJFL 150W LED I orlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 10 | All as per Ser Item No. 9 here-in-before but of 200 Watts Make: Bajaj Cat No. BJFL 200W LED Iorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 11 | All as per Ser Item No. 9 here-in-before but of 240 Watts Make: Bajaj Cat No. BJFL 240W LED WH MBor latest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 12 | Supply and fixing LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket duly removing existing unserviceable street light fitting complete all as specified and directed.Make:Bajaj Cat No. ENXT P 54L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 13 | All as per item No. 12 here-in-before but of 60 wattMake:Bajaj Cat No. ENXT P 72L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 14 | All as per item No. 12 here-in-before but of 70 wattMake:Bajaj Cat No. ENXT P 84L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 15 | All as per item No. 12 here-in-before but of 90 wattMake:Bajaj Cat No. BRTFG 90W LED CRorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 16 | All as per item No. 12 here-in-before but of 120 wattMake:Bajaj Cat No. BRTFG 120W LED CRorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves |
| 17 | Taking down old and unserviceablealumunium point wiring inbatten/ conduit and make good the disturbed surface to match the existingsurface, complete all as specified and directed by Engr-in-charge. |
| 18 | Taking down old and unserviceable submain wiring any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existingsurface complete all as directed by Engr-in-charge. |
| 19 | Taking down old and unserviceable, distribution board any type including/ sheet metal enclosures, after removing all connection and make good the disturbed surface all as directed by Engr-in-charge. |
| 20 | M&L for Point wiring using FRLSLH PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking\"s for boxes and making good to walls, floors etc fo concealed conduit wiring with modular flush box metal of GI sheetminimum 1.8 mm thickwith earth terminal for safety, flush metal GI box ofrequired modules as per site requirement and modular cover plate with support frame white in colour of required modules,3mm thick including all fittings i.e. tees, bands and junction boxes, screwsetc. complete for one light/fan/bulb point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. NOTES:- (a) Wiring shall be done by using colour coding(b) Earth wire shall be of green colour. |
| 21 | All as per item No 20 above One 3 pin socket outlet, 5/6 Amp socket outlet on same boardwith other switches. |
| 22 | All as per item No 20 above but One 3 pin socket outlet, 5/6 Amp socket outlet on independent board. |
| 23 | All as per item No 20 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 24 | As per item No 20 abovebut One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 25 | Supply and fixing in repairs socket,6A - 2/3 pin combined 2 module, fabio series 6 Amps 3 pinunversal socket with child safety shutter, Shrouded terminals compatible with all standard mobile chargers, ISI marked for the same board complete all as specified and directed. |
| 26 | Supply and fixing in repairs modular switch 1 way 6A, 1 module modular Switch fabio classic white series/Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 27 | Supply and fixing in repairs modular switch 2 way 6A, 1 module modular Switch fabio classic white series/Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 28 | Supply and fixing in repairs modular bell/buzzer switch 1 way 6A, 1 module modular Switch fabio classic white series/Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 29 | M&L for point wiring to one 3 pin 15/16 Amps socket outlet independent switch board, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking\"s for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheetminimum 1.2 mm thick with earth terminal for safety, flush metal GI box ofrequired modules as per site requirement and modular cover plate with support frame white in colourof required modules,3mm thick including all fittings i.e. tees, bands and junction boxes, screwsetc. complete for power point controlled with cables, 2.5 sq. mm size, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. (2.5 Sqmm for Phase and neutral and 2.5 Sqmm for earthing) |
| 30 | Supply and fixing in repairsSocket6/16A - 2/3 pin combined 2 module,(Fabio classic white) shuttered socket (heavy duty) 3 pinunversal socket with child safety shutter, Shrouded terminals compatible 2 ton AC and 3.5 KW geyser, ISI marked for the same board complete all as specified and directed. |
| 31 | Supply and fixingin repairs modular Switch fabio classic white series/Switch fabio classic white with indicator, ISI marked 16 Amps One Way switch complete all as specified and directed. |
| 32 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. NOTE - Colour code of cable Phase-Red Neutral- Black and Earth -Green. |
| 33 | As per item No 32 above but One 3 pin 5 amps socket outlet point on same board complete all as specified and directed. |
| 34 | As per item No 32 above but One 3 pin 5 amps socket outlet point on independent board complete all as specified and directed. |
| 35 | All as per item No 32 above but wiring with cable 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 36 | As per item No 32 abovebut One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 37 | Supply and fixingin repairs Bell push,flush type 5 Amps complete all as specified and directed. |
| 38 | Supply and fixing in repairs buzzer dingdongAC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 39 | Supply and fixing in repairs Socketoutlet 2 in 1,3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed. |
| 40 | Supply and fixingin repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 41 | Supply and fixing in repairs Switchpiano,flushtype single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed. |
| 42 | Supply and fixing in repairs Socketoutlet 3 pin, 15 Amp, flush type ,ISI marked complete all as specified and directed. |
| 43 | Supply and fixingin repairs Switchpiano 15 Amp,flushtype single pole, ISI marked 16 AX Amps One Way switch omplete all as specified and directed. |
| 44 | Supply and fixing in repairsCeiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed. |
| 45 | Supply and fixing in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 46 | Supply & fixing in repairs LED lights fitting 22 W LED 6000K(4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 47 | Supply and fixing in repair LED light fitting2 feet, 10 watt 220 V AC (Warm/ White) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 48 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVCconduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.NOTE:- Two wires of 4 sqmm and one wire of 4.0 sqmmand one run of PVC conduit shall be measured as one unit. |
| 49 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6.0 Sqmm to be drawn through and including PVCconduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.NOTE:- Two wires of 6 sqmm and one wire of 6.0 sqmmand one run of PVC conduit shall be measured as one unit. |
| 50 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 10 Sqmm, earth continuity conductor of size 10.0 Sqmm to be drawn through and including PVCconduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.NOTE:- Two wires of 10 sqmm and one wire of 10.0 sqmmand one run of PVC conduit shall be measured as one unit. |
| 51 | Supply and fixing in repairs modular 5 stepped type electronic fan regulator- 2M 100W laser marking as reqd at site complete all as per specified and directed. |
| 52 | Supply and fixing in repairs round shape slim fit down light LED 15 Watt round recess (Warm/ Warm White) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 53 | Supply and fixing in repairs square shape 36 watt 220 volts AC recessed mounting typelow depth aesthetically designed LED 2x2 feetflat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 54 | Supply and fixing in repairs Sheet Metal enclosuredouble door for DBs when MCBs to be used TPN-4 Waywith 200 Amp rated bus bar complete all as specified and directed. |
| 55 | Supply and fixing in repairs Sheet Metal enclosuredouble door for DBs when MCBs to be used SPN- 8 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 56 | All as per Item No 55 above but SPN - 12 Way complete all as specified and directed. |
| 57 | Supply and fixingin repairs Single pole and neutral enclosure with a two pin and earth plug and socketcomplete withone single pole MCB 20 Amp, 240 Volts complete all as specified and directed. |
| 58 | Supply and fixing in repairs 415V 10KA \"B\" curve miniature circuit breaker (MCB) TPN and current carryingcapacity63 Amp in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 59 | Supply and fixing in repairsamp rating 240V, 10KA \"B\"curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 60 | Supply and fixing repairsamp rating 240V, 10KA \"B\"curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioningcomplete all as specified and directed. |
| 61 | Supply and fixingin repairs socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 62 | Supply and fixingin repairs switch socket combination out let 5/16 Amps 5 in 1 flush type complete all as specified and directed.Make: Havells/Legrand/Indoasian/ABB/Siemens. |
| 63 | Supply and fixingin repairs Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 64 | Supply & fixing in repairs Bulk head fitting energy saving 10 W LED with opal diffuser light fitting including necessary fixing arrangements including LED bulb complete all as specified and directed. |
| 65 | Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b)PCC pit in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate).(c)CI cover with suitable handle(d)Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e)15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f)Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. On testing if the desired earth resistance (less than 3 Ohms) is not obtained, the earthting will be redone at no extra cost. |
| 66 | Taking down unserviceable ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repairs, complete all as specified and directed |
| 67 | Opening the unserviceable/burnt fan 1200/1400 mm sweep and cutting of old burnt copper windingand rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 68 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed. Make:- SKF/ NBC or Equivalent as approved by GE. |
| 69 | Supply and fixing in replacenment gun metal bushes of suitable size for ceiling fan/ exhaust fan including necessary mechanical work, complete all as specified and directed. |
| 70 | Supply and replacing of cord cable, three core 0.5 SqmmPVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 71 | Supply and replacing electronic step type fan regulator 240 Volt, 50 C/S, five step, suitable for 1200/1400mm sweep ceiling fan,complete all as specified and directed. |
| 72 | Supply and fixing Capacitor of 2.5 MFD for ceiling fan, complete all as specified and directed. |
| 73 | Supply and fixing Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 74 | M&L for replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make all as specified and directed. |
| 75 | Supply and fixing PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 76 | M&L for Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 77 | M&L for strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper, cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 78 | All as per srl item No. 77 here-in-before, but exhaust fan of 300mm sweep. |
| 79 | M&L for Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent as approved by GE. |
| 80 | M&L for painting the exhaust fan including louvers of size 300/ 450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all asspecified and directed. |
| 81 | M&L for servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. |
| 82 | Supply and fiixing of Heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. |
| 83 | Supply and fiixing Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. |
| 84 | Supply and fiixing thermostat for Geyser of capacity 25/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. |
| 85 | Supply and fixing Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 86 | All as per item Srl No. 85 above butfor geyser of 50 Ltr capacity. |
| 87 | All as per item Srl No. 85 above butfor geyser of 100 Ltr capacity. |
| 88 | S&F Rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 89 | Taking down old unserviceable plug top from geyser connection and Supply and Fixing in replacement plug top 15/16 Amps for Geyser, complete all as specified and directed. |
| 90 | S&F PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. |
| 91 | S&F Sheet Metal Enclosure with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and directed. |
| 92 | Supply and replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 93 | Supply and replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 94 | Supply and replacement of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 95 | M&L for disconnecting and taking out geyser of capacity 25 litre and replacement of copper/SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 96 | All as per item Srl No. 95 above butfor geyser of 50 Ltr capacity. |
| 97 | All as per item Srl No. 95 above butfor geyser of 100 Ltr capacity. |
| 98 | Taking down old unserviceable and supply & fixing stop cock brass 15mm dia not less than 200 grams, complete all as specified and directed. |
| 99 | M&L for preparation of surface of Geyser of capacity 25/50/100 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed. |
| 100 | Supply and fixing of geyser Bolt 120mm Long with nut & washers, complete all as specified and directed |
| 101 | Servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model including transporting to workshop & back complete all as specified and directed. |
| 102 | Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixingthe same as per the existingcomplete all as specified and directed. |
| 103 | M&L for replacement of thermostatfor refrigerator of 165 to 200 ltr capacity complete all as specified and directed. |
| 104 | M&L for replacement of thermal relay for refrigerator of 165 to 200 ltr capacity complete all as specified and directed. |
| 105 | M&L for charging of refrigerant R134A and testing for proper cooling and leakage complete for refrigerator and deepfreezers of any capacity complete all as specified and directed. |
| 106 | Taking out the burnt/ unserviceable compressor from the refrigerator of 210 to 320 ltr capacity and supply & fixingthe same as per the existingcomplete all as specified and directed. |
| 107 | M&L replacement of thermostatfor refrigerator of 210 to 320 litre capacity complete all as specified and directed. |
| 108 | M & L for replacement of thermal relay for refrigerator of 210 to 320 litre capacity complete all as specified and directed. |
| 109 | Servicing and overhauling of deep freezer of 210 to 400 ltr capacity of various make and modelincluding transporting to workshop complete all as specified and directed. |
| 110 | Taking out the burnt/ unserviceable compressor from the deep freezer of 210 to 320 ltr capacity and supply & fixingthe same as per the existingcomplete all as specified and directed. |
| 111 | M&L for replacement of thermostatfor deep freezer of 210 to 320 litre capacity complete all as specified and directed. |
| 112 | M&L for replacement of thermal relay for deep freezer of 210 to 320 litre capacity complete all as specified and directed. |
| 113 | Supply and fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece including old unserviceable geyser deposited to MES/EM store yard complete all as specified and directed. |
| 114 | M&L for painting to the outer surfaces of refrigerator of size 165 to 320 litre with two coats of synthetic enamel paint after cleaning the surface oil/dust free and making the surfaces smooth by filling putty where required, complete all as specified and directed. |
| 115 | M & L for repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper, cotton, sleeves, varnish, reassembling, replacement of knobs, LED\"s etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed. |
| 116 | All as per item Srl No. 115 above butfor stablizer of 1 KVA capacity. |
| 117 | M&L for repair to unserviceable/burnt piller heater of capacity 1000/1500/2000 watt, single phase 230volts by replacing the heater rod,blower motor, switches including wiring etc.complete all specified and directed. |
| 118 | M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all asspecified and directed. |
| 119 | Disconnecting the electric supply from the mains, transporting the window/split type air conditioner 2.0 Ton capacity from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 120 | All as per item No 32 above but for one light point controlled by two -2-way switches complete all as specified and directed . |
| 121 | All as per item No 32 above but One 3/5 pin socket, 15/16 Amps on independent boardwith cable 4.00 sq mm size and 2.5 sq mm for continious earthing complete all as specified and directed. |
| 122 | Supply and fixingin repairs Bell push,Modular type 5/6 Amps complete all as specified and directed. |
| 123 | Supply and fixing in repairs call bellvariable musical type as per approved by GE, AC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 124 | Supply and fixing in repair modularSocketoutlet 2 in 1,3 pin, 5 amp,flush typeISI marked for the same board complete all as specified and directed. |
| 125 | Supply and fixingin repairs witch modular socket combination 5 Amps 2 in 1 flush type multipurpose for independent board complete all as specified and directed. |
| 126 | Supply & Fixing in repairs LED lights fitting 18W LED 6000K(4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 127 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVCconduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.NOTE:- Two wires of 6 sqmm and one wire of 4 sqmmand one run of PVC conduit shall be measured as one unit. |
| 128 | Supply and fixing in repairs Aluminium, mild steel silver (satin nickel) finish double spot light great for installation above a dressing mirror, dressing table, to provide illumination while in front of mirror an E14 holder including lamp of 15 W, has a higher light output or a different color temperature with adjustable to required position matching three light code – ML182-3 (Warm White) suitableincluding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 129 | Supply and fixing in repairs round shape 36 watt 220 volts AC recessed mounting typelow depth aesthetically designed LED 2x2 feetflat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 130 | Notes :-An amount of Rs. 2,88,653.00 on account of Credit Schedule for Schedule \"A\" Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail