| 1 | Attending unserviceable/ non functional street light complaints(for street light / perimeter lights / high mast light / flood light / HPSV / HPMV / MH fittings etc of any type / size fitted on poles / walls / post / pillars etc including taking down LED street light/perimeter lights/high mast light/flood light /HPSV/HPMV/MH fittings of any watts and refixing the same to its original location after rectification of fault )by deploying technically qualified and experienced technicians to find out defect / taking out unserviceable parts such as electronic driver, plc. insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws, nuts & bolts and insulation tape to insulate the LT joint etc and testing complete all as specified and as directedat both domestic & technical areaAF Station Sulur. |
| 2 | Note for item No.1The following items are deemed to be inclusive of quoted rate :-(a)Thejob shall be carried out by a trained ITI qualified electrician ( in electrical). Documentary proof of the education of tradesman shall be produced before commencement of work.(b)The required quantity of \"Supply only\" items (quantity as ordered by Engineer-in-Charge)shallbe delivered / supplied to AGE E/M store yardwithin one calendar month from the date of commencement of contract and these items will be issued by AGE E/M store yard for attending unserviceable/ defective street light complaints.(c)The Contractor or his Authorised Representative has to inspect all Street / Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.(d) A Joint Inspection for Serviceability of all Street / Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User along with Contractor or his authorised Representative. (e)The Contractor has to arrange own movable Generatorof suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair.Electricity shall not be provided by the Department on this account.(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night time. Contractor has to arrange Electrician and Helper including all necessary T&P and Equipment\"s to remove the breakdown. Fault will be intimated through Telephone/ SMS.(g)In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under. (h) The penalty shall be applicable to the contractor if the contractor fails to rectify the defects / break down within twelve hrs after intimation of works of urgent nature to the contractor. The Engr-in-Chargeshall handover the complaintslip showing specification of work to the carried out by the contractorwith date and time of intimation and contractor shall sign in the office copy of slip as a token of receipt.The contractor shall attend the complaint immediately and shall report to Engr-in-Charge within 12 hrs. The contractor will keep his tradesmen in standby for attending any routine / urgent works from the executive.If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Chargeand the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay, then a penalty @ Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively of any penalty as per condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.The decision of the Accepting Officer is this regards shall be final and binding. |
| 3 | Note for item No.1(contd...)(j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.(k)Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department. (l)Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department. (m) Materials requiredfor the repairing of the lights shall be measured and paid separately under respective item(s) as \"supply only\". However labour required for taking down / dismantling existing fittings, repairing and replacing parts with new or re-installing and testing the street lights fittings shall deemed to beincluded in the rate quoted.(n)Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate. (o)All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor.Contractor will be solely responsible forthe safetyof the persons deployedby him for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted shall be deemed to include the cost of the same and no extra payment shall be made on this part.(p)All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department. (q)Attending and repairing complaint for onelightof any type shall be measured and paid as one Job. (r)Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.(s) The contractor shall maintain a record of all urgent work at and if the work to be repeated due to poor workmanship, the contractor shall be liable to repair the same without any extra expenditure to the Govt.(t)Contractor shall provide contact details of his responsible person(s) to JE / Engineer in charge for intimation of any emergency.(u) Anyreplaced Materials which are not specified in SCHEDULE OF CREDITshall be deposited to MES STORE YARD without any extra Cost to the Department. |
| 4 | Supply only LED Driver suitable for upto 45 watts LED light fittings, 230V,1-ph ,50Hz |
| 5 | Supply only LED Driver suitable for from above 45 watts and up to 90 watts LED light fittings 230V,1-ph ,50Hz. |
| 6 | Supply only LED Driver suitable for from above 90 watts to 160 watts LED light fittings 230V,1-ph ,50Hz completeNote for item No.2, 3 & 4:- (i) The make shall be same as that existing at site or as recommended by OEM.(ii)Drivers shall be technically/physicallycompatible for existingfittings & frame size shall be matched to existing fittings. |
| 7 | S&F Bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary arrangement for fixing the street light fitting on polewith two sets of clamps made out of flat iron 50 x 6mm, bolts, nuts and washers including applying two coats of aluminium paint over on coat of red oxide zinc chrome primer complete etc including taking out old unserviceable oneall as directed |
| 8 | S&FPVC insulated, unarmoured 3 core 1.0 Sqmm copper cable including making necessary cable terminations,lugs,glans etc completeincluding taking out unserviceable one all as directed |
| 9 | Cutting and trimming trees branches any girth and any size covering street lights mounted on pole/ wall/ building and cleaning the area aroud the pole for a distance of 1.5 mtr dia each and disposing the debris, clearing the site etc complete all as directed .Note:- work for 05 Nos of Lights shall be measured as one job. |
| 10 | S&FPVC Junction box of existing size on ground ,light weight pole mounting hinged type including MCB Spa 06Amps -1 No. including necessary clamp for MCB mounting and mounting of Box on pole with MS flat frame arrangement and necessary connector for looping in and looping out cable connection and suitable glands complete including taking out all old unserviceable items complete all as directed.Make : Sintex / Hensel or equivalent |
| 11 | Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and Supply and fixingLED security lights 60W with electronic driver with lumen efficiency not less than 110 lum/watt, High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection, PDC housing with finless design and high impact resistance (IK08) or higher impact resistance Polycarbonate/glasscover with integrated street Light optics, replaceable driver with minimum 4kV surge protection, THD < 10%, PF not less than 0.95, operating voltage 140-270Volts,50HZ with permissible CRI range of balance energy efficiency and visibility compatible for mounting on pole and Gig tubingdia 32-50mm dia , including necessary screws,nuts,bolts of suitable size and necessary wiring from light to Junction Box completeall as directed. |
| 12 | Disconnecting and taking out old unserviceable LED street light fitting from its existing locations and Supply and fixing LED security lights 90 W with electronic driver, multiple optics with lumen efficiency not less than 110 lum/watt, High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection, PDC housing with finless design and high impact resistance (IK08) or higher impact resistance, Polycarbonate/glasscover with integrated street Light optics, replaceable driver with minimum 4kV surge protection, THD < 10%, PF not less than 0.95, operating voltage 140-270Volts,50HZ with permissible CRI range of balance energy efficiency and visibility compatible for mounting on pole and Gig tubingdia 32-50mm dia , including necessary screws,nuts,bolts of suitable size and necessary wiring from light to Junction Box completeall as directed. |
| 13 | Disconnecting and taking out old unserviceable LED flood light fitting from its existing locations and Supply and fixing new LED flood light 120 watt with integrated electronic driver,multiple optics, outdoor type with lumen efficiency not less than 120 lum/watt, High performance low wattage street light with Housing high pressure die cast aluminium, high power LED light source, IP66 protection, PDC housing with finless design and high impact resistance (IK07) or higher impact resistance polycarbonate/glass cover with integrated street Light optics, replaceable driver with minimum 4kV surge protection, THD<10%, Pf not less than 0.95, operating voltage 140-270Volts,50HZ with permissible CRI range of balance energy efficiency and visibilitymounting on wall /bracket fixedwithnecessary clamps made out of flat iron 50x6mm,bolts,nuts and washers r complete all as directed Note for Item 9, 10& 11 :-(i) The unit rate quoted is deemed to be inclusive of 3 core 1.5 sq mm PVC sheathed copper cable drawn in PVC conduit (if reqd) upto min 7 m for connecting fitting to junction boxes. |
| 14 | M&L for Dismantling the existing packpole with foundation of any height by taking out unserviceable pack pole along connected accessories and clear site & dispose the same from original location etc and Supply, test, erection & commissioning of new Steel tubular swaged polesin a truly vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-31, 8.5m / 9m length poles including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009/ SSR PArt II 2020 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge. complete all as directed Note:-(i)Crane charges for dismantling & new erection shall be deemed to be including in quoted rate.(ii)The quoted rates shallinclude for cost ofEarth work, PCC foundation, coping etc comlpete.(iii) The quoted rates shallinclude provision of staywire to keep the poles in a truly vertical position till the foundations are properly set.(iv) The quoted rates shallincludecast iron base plate, nuts, bolts, screws, painting of steel tubular poles, drilling of holes in steel tubular poles for fixing of clamps, hooks for continuousearth wire/strip. (v)Thequotedrates shall include applying two coats of aluminium paint on coat of red oxide zinc chrome primer complete all as directed |
| 15 | Supply, test, laying & commissioning ofXLPE insulated, armoured (heavy duty) electric cable 3.5 / 4 Core X 10 Sqmm with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up tothe termination point (as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool, nuts ,bolts etcincluding taking out unserviceable burnt out cable from its existing location complete all as specified and directed by Engr-in-Charge :- |
| 16 | All as per item No. 13 but for cable of size3.5 / 4 Core X 16 Sqmm |
| 17 | All as per item No. 13 but for cable of size 3.5 / 4 Core X 25 Sqmm |
| 18 | All as per item No. 13 but for cable of size 2 core x 6 sqmm |
| 19 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying cable /foundation for fixing of poles and getting out in soft/ loose soil complete all as specified and as directed Engineer-in-Charge. |
| 20 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed by Engineer-in-Charge. |
| 21 | Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge. |
| 22 | S&F of HDPE double wall corrugated pipe conforming to IS -14930 Part with IP protection IP-67 having inner dia 50 mm complete terminated up to termination end point complete all as directed by Engr-in-Charge. |
| 23 | M&L Galvanised iron tubing 50 mm dia light grade laid in trenches/ floors/ walls for earth lead protection and cables at road crossing etc complete all as specified and directed. |
| 24 | M&L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/ new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed. |
| 25 | M&L for LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for 3.5 / 4 core x 10/16 sqmmcable with necessary jointing materials complete all as directed by Engr-in-charge. |
| 26 | All as per item No. 23 but for cable of size3.5 core x 25 / 35sqmm. |
| 27 | Isolate, disconnect, dismantle the burnt out lugs from load terminations/junction boxes etc and Supply & fixnew lugs with crimping tool as per existing one including fixing, insulation, termination to load termination end/junction boxesforcables of size25 sqmm to 35 sqmm complete all as directed by Engr -In-Charge.Note : cleaning the cable termination ends insulation as required length and fixing new lugs as per size including well crimping to the lugs for both ends of cable complete are included in quoted rates. |
| 28 | All as per item No. 25 but for cable of size up to 16 Sqmm |
| 29 | M&L for Meggering of LT UG cable between Span to Spanany type connection with complete disconnection & reconnection the samefor checking of fault and rectification for any size any place after disconnection of Supply complete. |
| 30 | M&L for cleaning Street lightpoles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminium paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. |
| 31 | M&L for Dismantling foundation of LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge. |
| 32 | M&L for road crossing/drain crossing by adopting trench less tunnelling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any type of soils including hard rock, MS casing pipe heavy duty of size 100 mm dia with 3 mm thick in any length including jointing materials to carry LT UG cables of size upto 120 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed. |
| 33 | S&F 3 pole MCB 25-63 Amps,C - curve,10kA, 50Hz, 440v in existing panel including necessary wiring & misc accessories for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. |
| 34 | S&FMCB TPN 16-32 Amps, C-curve,10kA, 50Hz, 440V in existing panel including necessary wiring & misc accessories for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. |
| 35 | M&L Earthing complete with galvanized steel plate electrode of size 60 cm x 60cm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and common salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore medium grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horizontally to the earth pit and shown in Electrical Plate No- 3 of SSR Part-1 (2009)complete all as specified and as directedNote:- The quoted rate shall include cost of Cement concrete chamber of PCC (1:2:64) type B1 using 20 mm graded stone aggregate ( The chamber shall be constructed one metre away from edge of earth pit) and.with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape including two coats of painting over a red oxide to exposed steel surfaces and Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance n.exc 50m etc. |
| 36 | Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of newMCCB 4 pole, 63Amps, 16kA, 415volts,50 Hz, suitable for existing panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections, suitable lugs, glands, nuts, bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL |
| 37 | Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of newMCCB 4 pole, 100Amps, 16 kA, 415volts,50 Hz, suitable for existing panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections, suitable lugs, glands, nuts, bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL. |
| 38 | Disconnecting & taking out unserviceable power contractor and Supply, test, install & commissioning of new Powercontactors 40 Amps, 4 pole,415Vcomplete all as specified and as directed. Make : Legrand or equivalent of L&T/ Siemens |
| 39 | Disconnecting & taking out unserviceable synchronising and Supply, test, install & commissioning of newsynchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights including taking down old unserviceable timer switches complete all as directed.Make :-Legrand or equivalent in L&T, ABB. |
| 40 | Disconnecting & taking out unserviceable power contractor and Supply,test,install & commissioning of newPowercontactors 63 Amps, 4 pole,415V, including taking down old item complete all as specified and as directed. Make : Legrand or equivalent of L&T/ Siemens |
| 41 | Disconnecting & taking out unserviceable LED flood light and Supply,test,install & commissioning of newLED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make : Phillips / Bajaj / CG / Wipro / Jaguar or equivalent |
| 42 | Disconnecting & taking out unserviceable power LED aviation light and Supply,test,install & commissioning of new LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete including taking down existing one complete all as specified and directed |
| 43 | Disconnecting & taking out unserviceable LED solar light and Supply,test,install & commissioning of new LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete.including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009/2010 and applying two coats of aluminium paint to pole surface complete all as directedcomplete all as directed Note:-(i)Crane charges for dismantling & new erection shall be deemed to be including in quoted rate.(ii) The rates include Earth work, PCC foundation, coping etc.(iii) The rates include staying the poles in a truly vertical position till the foundations are properly set.(iv)The rates include cast iron base plate, nuts, bolts, screws, painting of steel tubular poles, drilling of holes in steel tubular poles for fixing of clamps, hooks for continuousearth wire/strip. (v)Rates include for applying two coats of aluminium paint on coat of red oxide zinc chrome primer complete all as directed |