| 1 | Supplying and drawing 3 x 1.5 sq.mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. ( for pole wiring ) |
| 2 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing as required. |
| 4 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 5 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 6 | i) Upto 35 sq. mm |
| 7 | ii) Above 35 sq. mm and upto 95 sq. mm |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 9 | Upto 35 sq. mm |
| 10 | Above 35 sq. mm and upto 95 sq. mm |
| 11 | Laying of one number additional PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 12 | (i)Upto 35 sq. mm |
| 13 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 14 | B) 2 x 25 sq. mm (22mm) |
| 15 | B) 3.5 x 25 sq. mm (28mm) |
| 16 | B) 3.5 x 50 sq. mm (35mm) |
| 17 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 18 | Above 6.5 metre and upto 8.0 metre |
| 19 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia |
| 20 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required |
| 21 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 22 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 23 | 6 way, Double door |
| 24 | 12 way , Double door |
| 25 | Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted vincluding earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 26 | 4 way (4 + 12), Double door |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | Single Pole |
| 29 | Double pole |
| 30 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 31 | 40 Amp |
| 32 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 33 | 40 Amp |
| 34 | sub Total DSR Items |
| 35 | (A) Add multiplying correction factor as per memorandam No. 158/SE/GST/2024/02-E and GSTenhncement @ 18 % from 12 % (Combine MF- 1.035 |
| 36 | analysed Market item rates |
| 37 | Installation testing and commissioning 45 watt LED street light in existing 7 Mtr hight ocogonal pole and making connection, hole in pole etc as per site requirement |
| 38 | Fabrication, supplying, installation,and. testing of totally enclosed outdoor type front openable weather proof/ vermin control gear box size300 mm x 250 mm x 150 mm (Deep)and locking arrangement of box with latch.It shall be fabricated from 1.6 mm thick CRCA sheet complete having 4 nos. 63Amp capacity aluminium bus bar, one 10A TPN and 2 nos. 2Amp SP MCB \"C\"rating inter-connection ,earthing testing and commissioning and required quality blanking holes suitable inlet and outlet of4C X 25sqmmPVC / XLPE UG cable & Clamps & Bolts etc as required. CG box/Panel should be made CPRI Aproved from authorized fabricaters. |
| 39 | Fabrication, supplying, installation,and. testing of totally enclosed outdoor type front openable weather proof/ vermin control gear box size500 mm x 500 mm x 300mm (Deep)and locking arrangement of box.It shall be fabricated from 1.6 mm thick CRCA sheet complete having 4 nos. 63Amp capacity aluminium bus bar, 01 Nos slide comparatment for installation of LED gaears/driver set,one 10A TPN and 2 nos. 2Amp SP MCB \"C\"rating inter-connection ,earthing testing and commissioning and required quality blanking holes suitable for 4C X 25sqmmPVC / XLPE UG cable & Clamps & Bolts etc as required. CG box/Panel should be made CPRI Aproved from authorized fabricaters. |
| 40 | Installation testing and commissioning Street light control panel in the existing feeder pillar and connection as per requirement at site |
| 41 | Fabrication supply installation testing and commissioning of CPRI and IEC 61439 approved outdoor type feeder piller, double door made out of 2.03 mm thick CRCA powdered coated sheet of size 1000 mm(height) x 1500 mm (width) x 300 mm deep having 300 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & angle iron frame of size 1500 mm x 300 mm with 600 mm long legs made out of 35 mm x 35 mm x 5 mm thick angle & grouting the same in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources:6 graded stone aggregate 40 mm foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required.i) 100 Amp MCCB, 25kA-01(01 incomer ) ii) 80 Amp MCCB, 25kA-001 (Outcomer) Make-Havells/Indoasian/ Legrand/ Simens/ C&Siii)40 Amp DP Isolator-05 Nos-02 Toilet block & Garrage, 01(light) & 01 CHDH (power ckt), 01 spare Make-Havells/Indoasian/Legrand/Simens/C&Siv)6 A-32 A TPN MCB DHMGCTNF006-032Amp -04 Nos(03 for St Light+01 Adm Block(power ckt)) Make-Havells/Indoasian/Legrand/Simens/C&Sv) Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue -03 nos make L&T/Havells/simens |
| 42 | Fabrication supply installation testing and commissioning of CPRI and IEC 61439 approvedoutdoor type feeder piller, double door made out of 2.03 mm thick CRCA powdered coated sheet of size 900 mm(height) x 900 mm (width) x 300 mm deep having 300 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & angle iron frame of size 900 mm x 300 mm with 600 mm long legs made out of 35 mm x 35 mm x 5 mm thick angle & grouting the same in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources:6 graded stone aggregate 40 mm foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required.i) 63 Amp MCCB, 25kA-01(01 incomer )ii) 40 Amp DP Isolator-06 Nos(02 Adm Block, 01 For J/B, 02 for CHDH, 01 for KSM) Make-Havells/Indoasian/Legrand/Simens/C&Siii)40 Amp FP Isloator-01 Nosiii) Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue -03 nos make L&T/Havells/simens |
| 43 | Supply, Installation , testing and commissioning of set of01 Nos of150 watt (Variation of more than +/- 5% would not be allowed) outdoor type LED flood light luminaryhavingminimum efficency120 Lumen/ watt outdoor type Non integralLEDluminary lightshould be Main housing/heat sink material of high pressure dia cast aluminium, Front cover material- clear toughened glass,Lences-LEDIL secondary asmmetric lens along with heat sink fins to dissipated heat effectively with adjustable mounting brackets on pole , Ingress protection-IP66 & above, Impect resistance-IK07, input operation voltage range & frequency140 to 270 Volt AC at 50 Hz +/- 2Hz , Rated voltage 240 volt AC 50Hz ,PF not less than 0.95, operating teperature range -10 deg C to +50 deg C, working life of LED is minimum 50,000 hrs burning hrs @L70 , surge protection 5KV Internal &10 KV SPD, Correlated color tem- 3000K (as per ANSI) , with Gears of Electronic constant current potted driver (CC driver) efficiency with >85%,Short & Open circuit Protection, No Load, Overload EMI Envoirmental equivalent & Phase to phase protection 320V for 48Hrs & 350V for 24Hrs &all accessoriesetc as per specification etc . LED light suitable for mounting on the existing pole bracket & drilling of holes as required, making connectionwith 3 X 1.5 sqmm FRLS grade PVC insulated copper conductor cable from loop box to fitting i/c providing and fixing suitabe size of flexible pipe /insulaiton sleave with accessories from top slot of pole to fitting connections, interconnection etc.as per specification complete required . Make Philips/Bajaj/CG/Halonix/Orient/Wipro etc or equivalent specification |
| 44 | PITC of Onload Four Pole Changeover Switchwith sheet encloures,Eurolad/Ambidex, Ue-415 Volt, Ui-1000 Volt, AC,50 Hz 160 Amp, AC-23A, on wall with (25x300x 3 mm ) x4 nosMS iron Strip with fastner,Connection, interconnection with existing cable itc as required. Indoasian/Havells/HPL |
| 45 | Earthing with G.I. earthing Electrodes 2 metre long, 25 mm dia including accessories, and providing connection with GI/MS poleby existing 25mm X 6 mm GI strip as required. |
| 46 | Providing and fixing of 0.5 mtr GI Channel size 100 mm x 50 mm x 6 mm(9.56 Kg per Mtr) arm for installation of flood light on existing GI pole complete with clamps, bolts and nuts including drilling holes for installation of flood light etc as required. |
| 47 | (B) Sub Total |
| 48 | G/Total |