| 1 | Dismentaling of pump for over hauiling including greasing, glandpacking, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineerin- run for 10 hrs. in two spell complete as per direction of the Engineerin-Charge. |
| 2 | Dismantaling of horizontal pump and motor of 20/25 HP from the base and carrying the pump set to the nearest workshop for repairing the body thread of stag nut and carrying the same to the scheme andfitting fixing the pump set as before as per direction of the Engineer-in- charge. |
| 3 | Installation of pump motor set including carriage of materials from Departmental store yard to site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge |
| 4 | Providing and Installation of Horizontal pump motor set (Centrifugal) with allied equipments by maintaining proper level/slope, alignment etc. in/c all necessary nuts & bolts, washers etc. at site of work and making necessary electrical connection with main switch / starter with motor in/c commissioning & trial run for 10hrs. in two spell as per direction of the Engineer-in-charge. 25 HP mortar with 60 LPS 22 m head pump |
| 5 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge. |
| 6 | Supplying and greasing/applying of grease of approved quality as per direction of Engineer-in-charge |
| 7 | Supplying and fitting fixing of pump cooling pipe of best quality as per direciton of Engineer-in-charge |
| 8 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality. 150 mm Ø |
| 9 | Providing & fitting fixing coupling nuts & bolts (all Size)of approved quality. |
| 10 | Providing & fitting fixing coupling rubber bush (All Size)of approved quality. |
| 11 | Providing & fitting fixing coupling star bush (All Size) of approved quality. 150 mm dia |
| 12 | Providing & fitting fixing Pump Shaft of approved quality. |
| 13 | Providing & fitting fixing Shaft sleeve bush of approved quality.Cast Iron(CI) |
| 14 | Providing & fitting fixing Shaft sleeve nut of approved quality.Cast Iron(CI) |
| 15 | Providing & fitting fixing coupling/ impeller Key of approved quality. Stainless Steel |
| 16 | Providing & fitting fixing Casing ring of approved quality. 150 mm dia 8 mm thick |
| 17 | Providing & fitting fixing C.I. gland of approved quality. |
| 18 | Providing & fitting fixing Gland nut / Stag nut 100 mm long for gland of approved quality. |
| 19 | Providing & fitting fixing Lantern Ring for pump of approved quality. |
| 20 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.6305 Ball bearing (TATA /SKF) |
| 21 | 6306 Ball bearing (TATA /SKF) |
| 22 | 6309 Ball bearing (TATA /SKF) |
| 23 | 6310 Ball bearing (TATA /SKF) |
| 24 | Providing & fitting fixing G.I. bend/elbow in the pipe line including testing of joints complete as per CPWD Specification & direction of Engineer-in-charge.125 mm dia |
| 25 | 150 mm dia |
| 26 | Providing & fitting fixing MS flange(8 mm wall thickness) by welding G.I./MS pipe and placing position as per CPWD Specification & direction of Engineer-in-charge.125 mm dia |
| 27 | 150 mm dia |
| 28 | Providing & fitting fixing Rubber flange washer 6 mm thick at site of work of approved quality. 150 mm dia |
| 29 | 125 mm dia |
| 30 | Welding by gas or electric plant including transportion of plant at site etc. complete as per standard design. |
| 31 | Providing and fixing MS bolts including nuts and washers complete as per standard design:-Upto 300mm length. |
| 32 | Providing & fitting fixing MS tail piece with MS flange suitable for pipes complete as per CPWD Specification & direction of Engineer-in-charge.100 mm dia PVC Pipe |
| 33 | 125 mm dia PVC Pipe |
| 34 | 150 mm dia PVC Pipe |
| 35 | 200 mm dia PVC Pipe |
| 36 | 250mm dia PVC Pipe |
| 37 | Providing and layingof G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per specification and direction of Engineer-in-Charge.a) 150 mm dia |
| 38 | b) 125 mm dia |
| 39 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.125 mm dia |
| 40 | 150 mm dia |
| 41 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.C.I foot valve weight |
| 42 | C.I foot valve ring |
| 43 | C.I foot valve net |
| 44 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge. |
| 45 | Dismentaling of G.I pipe including necessary earth cutting etc. & return the same to Sub-Divisional store as per direction of the Engineer-in-Charge.125/150 mm dia |
| 46 | Dismentalling of motor for vernishing, heating etc. complete in/c reinstallation and making necessary electrical connection with main switch / starter with motor in/c trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge. |
| 47 | Providing & fixing G.I. plug of approved quality.125/150 mm dia |
| 48 | Labour charge for laying of G.I pipe conforming IS 1161,3589 & 1239 including fitting fixing complete as per direction of Engineer-in-Charge.150 mm dia nominal bore (medium) |
| 49 | 125 mm dia nominal bore (medium) |
| 50 | Supplying & fitting fixing of spare parts for 20/25 HP Horizontal motor.Motor fan |
| 51 | Terminal plate |
| 52 | Labour charge of lifting of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block as per direction of the Engineer-in-charge. |
| 53 | Labour charge for lowering & fifting fixing of 5,000 to 20,000 GPH water lubricated vertical submersible pump with motor including column assembly upto 100 feet with heavy duty chain pulley and block and making necessary electrical connection with main switch / starter with motor in/c trial run for 10 hrs in two spell complete as per direction of the Engineer-in-charge. |
| 54 | Labour charge for dismentalling and overhauling of 5,000 to 20,000 GPH water lubricated vertical submesible pump after taking out shaft etc. including necessary fittings of new & existing submersible materials as per direction of the Engineer-in-charge. |
| 55 | Supplying & fitting fixing of spare parts for submersible pump 5 HP to 25 HP of approved quality as per direction of Engineer-in-Charge. Impeller of brass make |
| 56 | Motor bush (Brass make) |
| 57 | Sand guard |
| 58 | Thrust bearing with plate |
| 59 | Pump bush (Brass make) |
| 60 | Safety clamp |
| 61 | Pump Shaft |
| 62 | Pump Stainless steel sleeve |
| 63 | Pump Coupling |
| 64 | pump neck |
| 65 | Pump column nut |
| 66 | Impeller key |
| 67 | Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50X50X6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feetX1feetX2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engineer-in-Charge. Size 1.80 X 1.20 X 0.025mtr |
| 68 | Supplying & fitting fixing manually operated oil immerged starter of approved quality. 30HP Osco/BCH Make |
| 69 | Supplying & filling of Transformer Oil in the oil tank of manually operated oil immerged starter of approved quality |
| 70 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg.- In - Charge. Stand finger |
| 71 | Gola finger |
| 72 | CT Coil |
| 73 | Magnet Coil |
| 74 | Circuit board for Osco starter of Backelite make |
| 75 | Supplying & fitting fixing power capacitor (ISI Marked) of approved quality.12.5 KVAr power capacitor |
| 76 | Providing & fixing 200 Amps busbar of size 600X 450X100 mm with 4 nos. copper strip of size 450X40X4 mm of approved quality. |
| 77 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.7/16 Copper Wire |
| 78 | Supplying and fitting fixing of selector switch on the panel board of approved quality. |
| 79 | Supplying & fitting fixing kit cut for main & sub-main swich (Male & female) as per direction of the Engineer in Charge.63 Amps main switch |
| 80 | 200 Amps main switch |
| 81 | Supplying and fitting fixing of 3 pole power conductors of different type, range from 25-300 AC-3 suitable for Fully Automatic Star Delta type Motor startar L&T , BCH, Havells make as per direction of Engineer-in-Charge.Type ML2.0 |
| 82 | Supplying and fitting fixing of spare contact kit , type ML 1.5/2.0/3.0/4.0/6.0 suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.Type ML2.0 |
| 83 | Supplying and fitting fixing of spare coil, type ML 1.5/2.0/3.0/4.0/6.0range suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in- Charge.Type ML2.0 |
| 84 | Supplying and fitting fixing of Thermal overload Relay, relay range 20- 32, & 28-42, directly operated suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge. |
| 85 | Supplying and fitting fixing of thermal timer type GT 200 ( 230/250 V,360 V, 400/440 V, 500 V, 50 Hz for 5-18 secs range) suitable for Fully Automatic Star Delta type Motor startar L&T ,BCH, Havells make as per direction of Engineer-in-Charge |
| 86 | Providing and fitting fixing DIN type fuse links HM 200 volts cat No.94332 Suitable for Type FN 400/ FNX 400 S-D-F & for HB 800 Fuse base (Cat. No. SF94332) of approved quality as per direction of the Engineer-in-charge. |
| 87 | Complete re-winding of 400/440 volt AC 3 phase horizontal motor of different make after taking out of entire burnt copper wire and rewinding the motor with proper gauge of supper enamel copper wire of approved quality , tapping , insulating , varnishing with vernish heating polishing and re-fitting the same as before including carriage of the motor from respective scheme and complete with trial run as per direction of the Engineer-in-charge. 20 HP |
| 88 | 25 HP |
| 89 | Complete re-winding of 400/440 volt AC 3 phase vertical submersible motor of different make after taking out of entire burnt copper wire and rewinding the motor with proper gauge of supper enamel insulated copper wire of approved quality , tapping , insulating refitting the same as before including carriage the motor from respective scheme and complete with trial run as per direction of the Engineer-incharge.12.5 HP-22.5 HP |
| 90 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.SMI-144, Range 0-400 to 0-500 |
| 91 | Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality. SMI-144, Range 0-10A |
| 92 | Supplying and fitting fixing of Indicator bulb (Flush type containig 3nos batton holder with bulb)) on the panel board of approved quality. |
| 93 | Supplying & fitting fixing of submerssible cable(copper) of size upto 12mm of approved quality as per direction of the Engineer-in-charge. |
| 94 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. 150 mm dia |
| 95 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality. 150 mm dia |
| 96 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality.150 mm dia |
| 97 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings and clamps, including cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - charge.Internal work - Exposed on wall.40 mm dia. nominal bore |
| 98 | Providing and fitting fixing of brass fullway valve with hand in the GI pipe line including cutting, threading etc, complete asper CPWD specification and direction of the Engineer - in - charge. |