| 1 | Subwork no 1- SWITCH ROOM - Item No - 01 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. |
| 2 | Item No - 02 Providing and filling around the well boulders filling of selected variety and size of boulders including cost of all materials ,labours , transportation etc with all leads and lifts etx complete. |
| 3 | Item No - 03 Providing and laying in situ Cement concrete M-15of trap or granite or quartzite or gneiss metal for foundation and bedding includingdewatering, form work, compacting,roughening them if special finish is to be provided, finishing if required and curing etcetera complete. |
| 4 | Item No - 04 Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) Excluding M. S. orTor Reinforcement |
| 5 | Item No - 05 Providing and casting in situ Cement Concrete of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted ) |
| 6 | Item No - 06 Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C. M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever nesessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) |
| 7 | Item No - 07 Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in plinth as backing with composite masonry including bailing out water manually, striking joints, raking out joints and watering complete. |
| 8 | Item No - 08 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and desingns or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use ofL&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) |
| 9 | Item No - 09 Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with CM 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted .) Excluding M S or Tor reinforcement. |
| 10 | Item No - 10 Providing and fixing in position steel bar reinforcement of various diameters for RCC pipes, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. Tor Steelcomplete.(including cost of binding wire) |
| 11 | Item No - 11 Providing & fixing steel window and door of various sizes as per detailed drawings fabricated from I.S. standerd sections without hot dip zinc coating without /with ventilators including fabrication , glazing with non acetinic / plain / obscured glass panels of approved type and quality of fixtures and fastening without teak wood boxing, and architraves and finishing with one coat of primer complete. with guard bars 12 mm square bar 10 cm . centre to centre. PWD S.S.R. I.NO. 1218/39.20 P.No.306 DOOR & Windows |
| 12 | Item No - 12Providing and fixing in position mild steel door/ window shutters including mild steel angle frame of size 50X 50X 5 mm. for fixing mild steel sheet 24 gauge including welding fixing to frame and all necessary fixtures including electrostatic powder coating etc. complete.DOOR & WindowsPWD S.S.R.22-23 I.No. 1233/39.35P.No. 309 |
| 13 | Item No - 13 Providing internal cement plaster 6 mm. thick in a single coat in cement morter 1:3 without neeru finish to concrete surface in all positions inculding scffolding and curing complete.Internal cement plasterRefn. :Bd.L.1 Sr. No. 882PWD S.S.R.22-23 I.No. 32.02P.No. 256 |
| 14 | Item No - 14 Providing internal cement plaster 12 mm. thick insingle coat in cement morter 1:3 without neeru finish toto concrete or brick surfaces,in all positions inculding scffolding and curing complete. |
| 15 | Item No - 15 Providing sand faced plasterexternally in cement motar using approved screened sand, in all positions including base coat of 15 mm. thick in cement mortar 1:4 using waterproofing compound at 1 Kg. per cement bag, curing the same fornot less than 2 days and keeping the surface of the base coat rough to recive the sand faced tretment 6 to8 mm. thick in cement mortar 1:4 finishingthe surface by taking out grains and curing for foureen days scaffolding etc. complete. |
| 16 | Item No - 16 Provinding and applying white-wash in Two coat on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete. |
| 17 | Item No - 17 Provinding and applying washable oil-bound distemper of approved colour and shade to old and new surface in two coats including scaffolding preparing the surfaces (excluding the primer coat) etc.complete. |
| 18 | Item No - 18 Provinding and applying three coats of water proof cement paint of approved manufacture and approved colour to the plastered surfacesincluding scaffolding if necessary, cleaning and preparingthe surface watering for two days complete.Sr. No. 1013PWD S.S.R.22-23 I.No. 35.15P.No. 276 |
| 19 | Item No - 19 Provinding and applying two coats of synthetic enamal paint of appoved colour to new stuctral steel work in building, including scaffolding if necessary, cleaning and preparingthe surface (excluding primer coat ) complete.Refn. :BDO.5 Sr. No. 1005PWD S.S.R.22-23 I.No. 35.07P.No. 275 |
| 20 | Item No - 20 Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete.(MJP DSR 2021-22, Sr. No.15, P.No. 45 ) |
| 21 | Subwork no 2- PUMPING MACHINARY [10.00HP 2 NOS] Item No1:- 200mm dia Sub pump set.Providing, erecting and giving test of10BHP/ upto 9 Stage 200 mm dia Sub pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump sheel be suitable for various delivery head and discharge with stainless steelshaft. Motor suitable for working on 415(+/-)10% volt 3 ph 50 c/s a.c. supply ,thrust corban bearing with stand entire hy .thrust. pump set shall be direct coupling with suitable strainer .pump should havesuitable discharge out late as per manufacture design .antithrust stream lined non return valve shallbe provided with pump 3mtr submersible copper conductor cable in single /double run, two pairs erection clamp 32 mm wx10mm thickshall be provided with pump.Q = 17066 H = 68 M |
| 22 | Item No. 2a:- 80 mm dia G.I.pipe. providing and errecting ISI mark,heavyclass,50 mm dia G.I. pipewith both end threaded &oneend B class socket. |
| 23 | Item No. 2b :-M.S.Special. providing and errecting M.S.Special for various diameter of pipe |
| 24 | Item No. 3a:- 80 mm dia G.I.Bend.providing and errecting ISI mark, B class, 80mm dia G.I.BendwithB class socket |
| 25 | Item No. 3b:- 80 mm dia G.I.Tee providing and errecting ISI mark, B class, 80 mm dia G.I.TeewithB class socket |
| 26 | Item No.4:-Earthing. providing and errecting rod type earthing (electrode of20mm dia solidG.I. Rodor G.I. Pipe of40mmdia ) 2.5 mtr burried in earth or( driven in the earth with blows of moderate force ) with necessarydoubleG.I. earth strip complete errected connected to nearest switch gear earth terminal. |
| 27 | Item No.5:- Flat flexible sub cableproviding and errectingflat flexible submersible cable with copper conductor 3 core , pvc insulated & pvc sheathed cable wire.size : 4 sq mm (motor to panel board).for 20 hp double run |
| 28 | Item No.6:- Armoured cable. providing and errectingAluminium conductor, XLPE / PVC insulated Armoured cable 3.5 or 4core cable size 16 sq mm |
| 29 | Item No7:- C.I. flanges.providing and errecting ISI mark,75/80 mm dia C.I. flanges with nut ,bolt &washer |
| 30 | Item No.8:- Channel frame.providing, errecting Channel frame |
| 31 | Item No.9:- Rain Prinventive box.providing , errecting Box type Rain Prinventive box size=1.5X1X0.35& 16SWG with lock arrangement A( panel box)=5sqmtr |
| 32 | Item No10:- plywood . providing , errectingplywood19mmthickness fixed to angle frame with necessary material |
| 33 | Item No. 11:- Angle frame.providing , errecting & fabrication ofangle framefor panel support |
| 34 | Item No. 12:- Fuse bridge.providing , errecting H C pattern porcelain fuse bridge with base and H C fuse links 415/ 500 volt, 63Amp.capacity |
| 35 | Item No. 13:- Triple Pole Switch. providing , errectingtriple pole iron clad /metal cladswitch& fuse 63 Amp 415/500 volt. |
| 36 | Item No. 14:- Change overSwitch. providing , errectingChange overSwitch. clad /metal clad four pole63 Amp 415/500 volt. |
| 37 | Item No. 15:- Volt meter. providing & errectinganalog type moving iron Voltmeterfor ACvoltage 0 to 500 volt range,50 c/s, flash type. |
| 38 | Item No. 16:- Ammeter. providing & errecting analog type moving iron Ammeterfor ACcurrent o to 30 Amp, directrange, 500 volt, 50 c/s flash type. |
| 39 | Item No. 17 :- Indicating Lamp. providing & errecting LED type indicating pilot lamp with LED colours RED/ Yellow / Green] 230 / 250 Volt on provided box /panel with necessary material, wring & connectons. |
| 40 | Item No. 18:- Capacitor. providing & errectingbank of metalisedpolypropylene condensers with standard capacities of 1 , 2 , 3 , 5 , 7 , 12 , 15 , 20 & 25 kvar unit P.F. corre-ction operation on 3 ph 50 c/s500 volt + or- 10 %externally dischaging resis-tancs earthing terminals & built up angle iron or chennel iron framework&provided with terminal cover box completed& tested. |
| 41 | Item No.19:- DOL /FASD Starter.providing & errectingDOL /FASD starterto operate squirrel cage induction motor working on 380-440 volt, 3 phase,50 c/s with no volt coil and over load Relay (range 30 Amp )with nacassary material and connected to supply, etc completed.for > 7.5 hp to 12.50 HP capacity |
| 42 | Item No.20:- Sluice Valve 100 mm dia. providing & errecting in position Sluice Valve-100mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification. |
| 43 | Item No. 21:- RefluxValve 100mm dia. providing & errecting in position RefluxValve 100mm dia and class including necessary jointing accessories (flanges, nut, bolts and rubber packing) as per the specification. |
| 44 | Item No. 22:- MS bareels for chain pully Providing and supplying ISI standard MS specials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete. MS barrels (pipe pieces) locally manufactured (for small quantities) |
| 45 | Item No. 23:- Chain pully block of 1 TonProviding, erecting triple spur gear type chain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 3832 carrying ISI mark. |
| 46 | SUBWORK NO 3 RCC ESR 21000 LITRS 12 M STAGING ITEM NO 1 Designing (aesthetically), & constructing RCCelevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters center to center including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling, disposing ofthe surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and joining of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories which accessories such as M.S. ladder, C.I. manhole frame and covers water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case form ground level to roof level, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three costs of cement paint to the structure including roof slab and giving satisfactory water tightness test as per I.S. co Notes. |
| 47 | ITEM NO 2 Providing and supplying ISI standard CI double flanged pipes including all taxes ( Central and local ) railway fight, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc. complete as directed by Engineer-in-charge.i) 80 mm dia (For Inlet& Overflow) |
| 48 | iI)100 mm dia (For Outlet) |
| 49 | ITEM NO 3 Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge.D/F Specials 80 to 300 mm dia.. |
| 50 | ITEM NO 4 Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store , unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-1 i} 80 mm dia |
| 51 | ii) 100 mm dia |
| 52 | SUBWORK NO.4 RCC ESR 47000 LITRS 12 M STAGING ITEM NO 1 Designing (aesthetically), & constructing RCCelevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 meters center to center including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling, disposing ofthe surplus stuff within a lead of 50 meters, all labour and material charges including lowering, laying, erecting, hoisting and joining of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories which accessories such as M.S. ladder, C.I. manhole frame and covers water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case form ground level to roof level, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three costs of cement paint to the structure including roof slab and giving satisfactory water tightness test as per I.S. co Notes. |
| 53 | ITEM NO 2 Providing and supplying ISI standard CI double flanged pipes including all taxes ( Central and local ) railway fight, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc. complete as directed by Engineer-in-charge.i) 80 mm dia (For Inlet& Overflow) |
| 54 | iI)100 mm dia (For Outlet) |
| 55 | ITEM NO 3 Providingand supplying ISI standard CI flanged/ S& S specials excluding GST levied by GIO & GOM in all railway fright, insurance, unloading from railway wagon, loading to truck transport to stores/ site, unloading stacking etc complete as directed as directed by Engineer-in-charge.D/F Specials 80 to 300 mm dia.. |
| 56 | ITEM NO 4 Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store , unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-1 i} 80 mm dia |
| 57 | ii) 100 mm dia |
| 58 | SUBWORK NO 5 Interconnection toEX SYSTEM 90 mm PVC 4 & 6 kg /cm2 L 150 M eachITEM NO 1 Providing and supplying in standard lengths ISI Mark rigid unplasticised PVC pieps suitable for potable water with solvent cement joints including cost of couplers, as per IS specification No. 4985/1988 including all local central taxes, transportation fright charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement etc. complete.90 mm dia.PVC.6.Kg/Cm2.Pipes. |
| 59 | ITEM NO 1 B Providing and supplying in standard lengths ISI Mark rigid unplasticised PVC pieps suitable for potable water with solvent cement joints including cost of couplers, as per IS specification No. 4985/1988 including all local central taxes, transportation fright charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement etc. complete.90 mm dia.PVC.4.Kg/Cm2.Pipes. |
| 60 | add 5%PVC Specials |
| 61 | ITEM NO 2 Providing, double flanged Sluice Valves conforming to IS-14846 including worm gear arranegments as per test pressure,stainless steel spindle, caps including inspection charges ,transportation up to departmental store,unloading stacking excluding GST levied by GOI & GOMin all respect etc. complete . Sluice valves Without bypass arrangement- PN-180 mm dia.Sluice Valves |
| 62 | ITEM NO 3 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 meters and lifts as below, stacking and spreading as directed, normal dewatering, preapring the bed for foundation and excluding back filling etc. complete. Lift 0 to 1.5 m. |
| 63 | ITEM NO 4 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 m |
| 64 | ITEM NO 5 Excavation for foundation / pipe trenches in hard murum and Boulder W.B.M road including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Lift 0 to 1.5 m |
| 65 | ITEM NO 6 Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20 cm layers including watering and compaction etc. murum bedding |
| 66 | ITEM NO 7A Lowering, laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, ruber ring, giving satsifactory hydraulic testing as per IS code, etc. complete. ( With cement solvent joint / ring if joint) Working pressure 6 and 10 Kg/Sq.cm. 90 mm dia.PVC.6.Kg/Cm2.Pipes. |
| 67 | ITEM NO 7B Lowering, laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, ruber ring, giving satsifactory hydraulic testing as per IS code, etc. complete. ( With cement solvent joint / ring if joint) Working pressure 6 and 10 Kg/Sq.cm. 90 mm dia.PVC.4.Kg/Cm2.Pipes. |
| 68 | ITEM NO 7CHydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position 90 mm dia.PVC.6.Kg/Cm2.Pipes. |
| 69 | ITEM NO 7DHydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testingfor specified length,including cutting,placing end cap making arrangement for filling safe water using reciprocating tupe pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position 90 mm dia.PVC.4.Kg/Cm2.Pipes. |
| 70 | ITEM NO 8 lowering and laying jointing in position following CIDF reflux valves buttervalves and sluice valve including cost of all labour jointing materials including nut bolts and giving satisfactory hydraulic testing .80 mm dia CIDF sluice valve |
| 71 | ITEM NO 9 Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavatin, B.B. masonry in C.M. 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. Note : wall thickness : 0.23 m for depth of 0.9 m and 0.35 m for balance depth exceeding 1.2 m)60 x 45 cm size and depth of 0.90 mwith precast RCC slab Cover |
| 72 | ITEM NO 10 Refiling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging etc. complete. |
| 73 | ITEM NO 11 Making cross connection to existing distribution main of any type including excavation, breaking and removing existing pipes, lowering, laying of specials and pipes in their position, refilling, closing the water supply in that area, dewatering and restarting the water supply, etc. complete as directed by Engineer-in charge for following diameters of existing pipeline, irrespective of diameter of branch line. (The number of joints involved will be paid separately depending upon the nature of joints and required pipes, valves and specials will be supplied free of cost at stores.) 80 mm |
| 74 | subwork no 6- ESTIMATE FOR TRIAL RUNCommissioning running and maintaining the scheme to quantites,rated capacity,including manning necessary personnel such as operator, valveman etc. as per requirements of the scheme and who should also administer chemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer - in - charge.A) For single village. ( Three Months )Note :- Required chemicals to be supplied by Department free of cost and electricity bill will also be paid by the Department. |
| 75 | GST.18% |