| 1 | Scraping of White wash |
| 2 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed |
| 3 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 4 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. |
| 5 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. III (size of door 851mm to 1000mm) |
| 6 | Providing and fixing curtain rail 1.90cm chrome-plated with end bracket. Including sockets and brackets |
| 7 | Renewing glass panes with putty and nails wherever necessary Glass panes weighing 10.75 Kg/sqm |
| 8 | Providing and fixing mineral fibre false ceiling tiles at all heights at height upto 4 mtr of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH)of 99%, Light Reflection >85%, thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt -6&7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest onperipherywalls/partitionswiththehelpofGI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights.Theworkshallbecarriedoutasper specifications, drawings and as per directions of the engineer-in-charge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm |
| 9 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position(Code : IS 2202-1(1999) )Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-30mm |
| 10 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings For shutter area above 0.50 sqm |
| 11 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Door and window frame of size 113mmx60mmx with 35mm wide single rebate |
| 12 | RemovingDoorsandWindows(Steelorwood)withchowkhatsbymakingrecessesinwallswhenthewallisnottobedismantled. Doorsofarea3sqmandbelow. |
| 13 | Scraping of Cement Plaster |
| 14 | 12.5 mm thick cement plaster 1:4 |
| 15 | Carpenter (Ist Class) for Repair of wood work |
| 16 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250mm x 16mm |
| 17 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 18 | Reinforced cement concrete M-25 mechanicallybatchmixedusingbatchtype concretemixerasperIS:1791andvibrated byneedlevibratorbutexcludingsteel reinforcementcentringandshutteringin superstructure. |
| 19 | Coldtwisteddetormed(Ribbed/Torsteel)Bars (Fe500gradeasperIS1786-2008),forR.C.C works, where not including in the complete rate of RCCincludingbendingandbindingplacingin position complete |
| 20 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 21 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 22 | Providing and fixing commercial plywood 25mm thick |
| 23 | Providing & Fixing decorative high pressure laminated sheet 1mm SF thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 24 | Providing & Fixing decorative laminated sheet 0.72mm thick and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality |
| 25 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete in all respect as per the directions of Engineer-in-charge.50mm |
| 26 | Providing & fixing Stainless steel ball bearing hinges of size 100x89x3mm ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 27 | Providing & fixing 6\" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 28 | Providing & fixing 6\" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
| 29 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps. U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia. |
| 30 | Providing and fixing 110mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.e 110 mm bend. |
| 31 | Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm compling/sockete |
| 32 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : |
| 33 | Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect. |
| 34 | Wire gauge fixed on chowkats with 25mm thick Hollock wood cover molding of full width |
| 35 | Providing and fixing commercial plywood 18mm thick |
| 36 | 10mm thick cement plaster 1:3 on floors |
| 37 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. 30 mm thick |
| 38 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |