Health and Family Welfare Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47264729

Tender For Supply Of Drugs/Surgical And Equipment, Medicine During The Year 2024-25

Issued by Statutory Bodies & Commissions/Committees · barwani, Madhya Pradesh
Tender Value
22 Lakhs
Estimated cost
Bid Submission
30 Jan 2025
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
barwani → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply Of Drugs/Surgical And Equipment, Medicine During The Year 2024-25- 1 Type c category equipments, furniture, implants and medicines 2 Autoclave Surgical drum SS-Size 15*12 approx 3 Autoclave Surgical drum SS-Size 9*9 approx 4 Autoclave Surgical drum SS-Size 11*9 approx 5 Autoclave Surgical drum SS-Size 11*5 approx 6 OT Trolly (Dressing) 7 Supra Pubic Trocar 12 No 8 Supra Pubic Trocar 8 No 9 Supra Pubic Trocar 14 No 10 Tooth Forcep & Non Tooth Forcep Midium Size 11 Suture Cutting (Micro) 12 Mayo Scissors (Carved) Midium 13 Nebular (Bone Cutter) 14 Sharp Scissors 9.0ml 15 Tissue Cutting Scissors Carved Midium 16 Mosquito artery big Size 17 Mosquito artery Medium artery 18 Gigli Saw vial 19 Bone Saw Big 20 Hegars Dilator set 21 Biopsy Gun 22 H.B Skin grafting handle 23 Bull dog 24 clamp 25 Suction Cannula disposable 26 O.T. Light double dome 27 Cautery Pin 28 Triway catheter No 20 29 Urinary Cathetor No 12, 30 Urinary Cathetor No 14 31 Urinary Cathetor No 10 32 K-90 Catheter 33 Tommy Syringe 34 Hperdomic Needle No 16 35 Hydrogen Peroxide (500ml) 36 Small Tooth 37 Non Tooth forcep 38 Bone Vax 39 Senetizer 40 Disposable Syrienge 2ml 41 Disposable Syrienge 5ml 42 Disposable Syrienge 10ml 43 Disposable Syrienge 20ml 44 Uro Bag 45 Adhesive Tape Roll 4 46 Paper Adhesive Roll PER Pack 47 Gloves No 6.5 48 Dressing Disposeble Gloves 49 Spinal Needle 50 Ven flow No 20 51 Suction Tube 52 Oxygen Key 53 Oxygen Flow Meter Set 54 Vicryl 3.0 Round body 55 Vicryl 2.0 ½ cr RB Needle 30mm 56 Vicryl 3.0 ½ cr RB Needle 22mm 57 Vicryl 3.0 ½ Cutting Needle 58 Vicryl 1 ½ cr RB Needle 36mm 59 Vicryl 1.0 ½ cr RB Needle 30mm 60 Ethilon 1. 0 ½ cutting Needle 36mm 61 Ethilon 2. 0 3/8cutting Needle 36mm 62 Ethilon 3. 0 3/8cutting Needle 36mm 63 Silk – 1.0 64 Silk – 2.0 65 Silk – 3.0 66 Hydrogen peroxide 6% 400ml 67 Butroclot solution 68 Drain sheet (Currugeted) 69 Sumag Ointment 70 Dis. Needle 16no, 71 K90 Katheter 72 3 way stop cock with extension line 73 Needle 24x1 ½ 74 Lignocain 4% vail 75 Endotrachial Tube 7.5cm 76 Endotrachial Tube 8.5cm 77 Poly Propylene 2.0 1/2 cr RB Needle 30mm 78 Surgical Cap 79 Chair S TYPE 80 Abdomans Spange 20 X20 81 Tailar Scisor 82 Feetal Doplar DIGITAL 83 Nebulization Machine 84 Giuco Meter 85 BP Instrument standmodal 86 BP Instrument Digital 87 Palse oximeter tabel Top 88 fogging Machine 89 Digital Tharma meter 90 Baby Tray 91 Autoclav drum 92 Gyser 20 LITER isi MARK 93 Wheel Chair 94 Digital Watch 95 O2 Flow Meter 96 Kideny Tray 8 97 Doctor Chair 98 Sizzer 8 99 Epigiotomy Sizzer 100 Hand Wash 500 ml 101 dispossable syrienge 50ml 102 dispossable syrienge 20ml 103 dispossable syrienge 10ml 104 dispossable syrienge 5ml 105 dispossable syrienge 3ml 106 dispossable syrienge 2ml 107 Follyes Cathetar 16 No 108 Endotrachial Tube 2cm 109 Endotrachial Tube 2.5cm 110 Endotrachial Tube 3cm 111 Endotrachial Tube 3.5cm 112 Endotrachial Tube 5cm 113 Endotrachial Tube 6cm 114 Endotrachial Tube 7cm 115 Endotrachial Tube 7.5cm 116 Endotrachial Tube 8.5cm 117 Endotrachial Tube 8cm 118 Air Pressure Line 119 O2 mask 120 NRBM Mask 121 Flatus Tube 122 Glucometer Strip 123 Albumin Strip 124 UTP Kit 125 Celispaid 126 Senitary Pad 127 Ambu Bag Adult 128 Ambu Bag pediatric 129 mettress 4 (6 x3) fom with cover 130 Baby Diper 131 Ventilator Tube 132 Pediatric dreep set 133 IV Stand SS 4 Wheel 134 Oxygen Key 135 Sterlizer Medium Size 136 Chair office 137 Steel Tray with Cover 138 Nebulization Mask 139 Refrigerator 180LIT 140 Strature with wheel 141 Lade Aprone 142 Nasalprobe Child 143 Nasalprobe Adult 144 Mayo sizzer 145 Fine tooth Forcep 146 tooth Forcep big 147 Step StoolMS 2 Step 148 Pattela Holding Forcep 149 Bone Cutter 150 Giggli Wire 151 T- Handel 152 Tubalring 153 Mucous Extractor 154 Caord clamp 155 Baby Tag 156 Romo Vac sizes of10, 12, and 14 FGbellow unit capacity is 800 ml.curved Needle Length is 175 cm. 157 Pules oximeter tabal Top 158 Weight Machine Adult 159 Enfusion Set 160 PPE Kit 161 Feeding Tube 5 no 162 Feeding Tube 6 no 163 Feeding Tube 7 no 164 Feeding Tube 8 no 165 P.M.O. Line 166 Adult Nosal Prong 167 Water Cooler 40 Litter 168 Urine polmale 169 Tuning fork (256) 170 Stop Watch 171 Percussion hammer 172 omce Table 173 Office Dustbin 174 LED Torch 175 Iron Almiraha 6 176 DigitalClock 177 FUJI PRINTER DRY IMAGING FILMOBX 10 DIGITAL X-RAY FILM 178 DISTAL REDIUS T,T OBLIQ PLATE (SIMPLE) 179 3.5 MMLOCKING CLEVICALPLATE ( 5 TO 8 HOLE ) 180 3.5/2.7 MMLOCKING CLEVICAL SUPERIALPLATE (5 TO 8 HOLE) 181 ADWANTEG SYRING 182 Illizarov Set 183 Modular Bipolar Set (1 Cese) 184 Blood Bank Refrigerator Technical specifications: Blood bank refrigerator1- Blood bank refrigerator – capacity 100 blood bags or more with two or more shelves.... 2- Inner chamber made of stainless steel, outer chamber made of powder coated steel sheet with high quality insulation material between the walls.3- Microprocessor based temperature controller with preset temperature 4 degreecentigrade plus minus 1 degree centigrade .and digital temperature display. 4- 50 htz 220-240 volts Ac power supply (single phase power supply in India). 5- Audio-visual alarm for low (less than 2 degree centigrade) and high (more than 8 degree centigrade) temperature.. 6- 7 day circular temperature chart recorder- in built.. 7- Air circulation fan. 8- Light bulb inside chamber. 9- Auto defrost mechanism or frost free, CFC free. 10- In built line voltage corrector 11- Vendor has to support the specifications with manufacturer’s brochure failing which offer may be rejected. Vendor has to demonstrate the equipment at BHEL General Hospital, Hyderabad within specified time limit, if asked for; failing which offer will be rejected. 185 Blood Celll Counter Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC3 histograms for WBC, RBC and PLTPrediluted mode ≤20μL | Whole blood mode ≤9µL , 60 samples per hour10.4 inch TFT Touch ScreenChinese, English, Spanish, Portuguese, Russian, French, Bahasa, IndonesiaUp to 400,000 results including numeric and graphical information LAN Port supports HL7 protocol | Support bi-directional LIS4 USB ports (for external printer, software upgrade, barcodereader, external WIFI, keyboard and mouse), LAN port (1)Thermal recorder, 50 mm wide paper, various printout formats External printer optionalTemperature: 15°C~35°C | Humidity: 10%~90%Air pressure: 70kPa~106kPa(100V-240V)±10% through online UPS (rating 1 KVA)≤180VA | (50Hz/60Hz)±1Hz ,410(L) x 300(W) x 400(H) mm ; 20Kg 186 DefibrillatorTECHNICAL SPECIFICATION OF DEFIBRILLATORDESCRIPTION of Function• Defibrillator is required for reviving the heart functions by providing selected quantum ofelectrical shocks with facility for monitoring vital parameters.Operational Requirements• Defibrillator should be Bi- Phasic, light weight and latest model• Should monitor vital parameters and display them• Should print the ECG on thermal recorders.• Should work on Manual and Automated external defibrillation (AED) mode. Manualselection up to 270 J.• Should be capable of doing synchronized & asynchronized cardioversion• Can be operated from mains as well as battery• Should have defibrillator testing facilityTechnical Specifications• Should be a Low Energy Biphasic defibrillator monitor with Recorder, having capability toarrest allarrhythmia within a maximum energy of 360 Joules• Should monitor ECG through paddles, pads and monitoring electrodes and Defibrillatethrough pads and paddles.• Should have Automatic Lead switching to see patient ECG through paddles or leads• Should measure and compensate for chest impedance for a range of 25 to 150 ohms• Should have a built in 50mm strip printer/ thermal recorder• Should have charging time of less than 3 seconds for maximum energy. Charging indicatorshould be there.• Should have bright electroluminescent display for viewing messages and ECG waveform of4 seconds• Should have external & internal paddles with paddles contact indicator – for good paddlecontact. Single Adult and pediatric paddles should be available.• Should have event summary facility for recording and printing at least 250 events and 50waveforms.• Should be capable of printing Reports on Event summary, configuration, self test, batterycapacity etc• Should have facility for self test/check before usage and set up function• Should have SP02 and NIBP integrated facility• Should have user friendly color coded operationEnvironmental factors• The unit shall be capable of operating continuously in ambient temperature of 10 -500 C andrelative humidity of 15-90%• The unit shall be capable of being stored continuously in ambient temperature of 0 -500Cand relative humidity of 15-90%• Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of Safety forElectromagnetic Compatibility.Power Supply• Power input to be 220-240VAC, 50Hz. Power cable should be fitted with Indian plug andadapter.• Resettable overcurrent breaker shall be fitted for protection• Should have a Rechargeable Battery capable of usage for at least 90minutes or 30discharges. 187 Electrolyte Analyzer Method Sample Speed :-Multi-Biosensor TechnoloTechnology 60-120µlISE ≥ 80 tests / hour Printer Inner Thermal Printer Expand FunctionAmbient Conditions PowerPower Requirement RS232 & COM Connector, Computer and Barcode reader available0-40°C, Relative humidity ≤ 85% AC 80V ∼ 260V, 50-60Hz, ≤ 80WEarth Voltage <5V, Online UPS (230V)with isolated, transformers - 0.5 KVAParameters K+ Detection Range (mmol/L) 0.50 ∼ 20.00 Precision (CV)≤1.0% Resolution (mmol/L)0.01MeasureScope & Precision Na+ 15.0∼200.0 ≤1.0% 0.1 Cl- 15.0∼200.0 ≤1.0% 0.1 Ca+ 0.10∼200.0 ≤1.0% 0.01 pH 4.00∼9.00 ≤1.0% 0.01 188 Elisa Reader WasherSpecifications for Microplate (ELISA) Reader1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD2. Should have linearity of ≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD; accuracy of ≤1.0%or 0.010 from 0.000–3.000 OD at 490 nm; precision of 1.0% or 0.005 OD from 0.0–2.0 OD;1.5% from 2.0–3.0 OD and resolution of 0.001 OD3. Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm includedfilters4. Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec5. Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths6. Should have onboard graphical thermal printer and USB2 interface with PC or Mac datastations for data output7. Should be able to store data for over sixty assay protocols8. System should come with a comprehensive software package allowing colorimetric andturbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix,normalization, and curve fit9. Software should have the functionality of flexible template creation for any microplate formatup to 1,536 wells10. Software should be either license free or license for minimum 5 systems should be providedSpecifications for Microplate washer Automatic washer compatible with strips and 96-well microplates that have flat-, U-, or Vbottom wells. Programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottomwashing, crosswise aspiration, and overflow washing. Dispensing speed control A plate shaking option to help minimize bubbles and adherence of liquid to well sides. Wash bottle sensor to detect high waste liquid levels Up to 75 programmable washing sequences Easily removable 8- or 12-way manifolds Easily accessible manifold interior for maintenance Removable and autoclavable plate carrier An aerosol protection cover Integrated vacuum and dispensing pumps to ensure accurate and quiet washing and toeliminate the need for external pumps. Residual well volume should be < 6 µl Wash bottle volume should be 2000 ml Soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes. Should come with 8-way manifold and 12-way manifold should be quoted in optional. On-board software should be capable of storing up to 110 wash protocols. Operating temperature 15-40 °C. Dimensions (WxDxH) not more than 35x43x20 cm Both instruments should be of from same manufacturer 189 Semi-Automatic Biochemistry AnalyzersTechnical Specifications Human Machine Interface Touch Panel / Key Board / MouseLinear Measurement Range 0.000 to 3.000 Absorbance Units (A)Photometric Accuracy ±2% or 0.007 whichever is higher, from 0 to 2.0A, ±3% from 2.0A to 3.0ADrift <0.003A/hr.Optical Measurement Silicon Diode Filters Type of filterWave LengthHalf Bandwidth Filter SelectionFlow cell TypeFlow cell volumeSipping Volume Sipping Mode Cuvette Volume : Interference: 340,405, 450, 505, 546, 578, 630+2 Optional: ±2nm: By Stepper motor: Stainless steel body & Quartz Window: 32 μι: 300 to 1000 μι: Automatic by specially designed Peristaltic Pump: 500 μι Temperature of Cuvete/flow cell Block Method Temperature Light Source Warm up Time Display Printer Memory CPUBuilt in Incubator : By Peltier effect: 25°C, 30° C and 37° C: 6V/10W Tungsten Halogen lamp: 90 Sec.: 7 TFT Display 300 x 930: Built in 55 mm, stationary head graphical thermal printer: DDR, & DRAN 1 GB, Flash 256 MB: ARN Cortex A8720 MHz: 2 Place for coagulation reagent | 15 Place for coagulation Cuvette 5 Place for test tubes Storage Capacity 2000 Open tests with 30 QC results/test (Normal and Abnormal controls)200000 Patient results with patient ID and GraphAnalysis Mode 1 point, 2 point (Sample blank) | Fixed time | Kinetic | CoagulationConcentration calculation : By factor or by standard Blanking PortPower WattageVoltage Operating Position : Water, Reagent: 4 USB, LAN Rj45: 100 Watts: 110-240 Volts ±10%, 50-60 Hz: On horizontal, flat, rigid and vibration free surface Operating Conditions Temperature Relative Humidity : from +18° C to 35° C: up to 85% Storage Condition Temperature Relative Humidity EnclosureSize (cm) Weight : from 10° C to + 60° C: up to 85%: ABS Fire retardant: 30X38X13.5 (LxBxH): 7.0 Kgs. (Approx) 190 Suction MachineSpecificationsPortable suction unit: size 38x17x28.5cm, weight 5.1kgDescription (e.g.: model Vario A/C, manufacturer Medela)Technical specifications: SUCTION MACHINE with pump:- Power supply: 230-240V/50Hz- Vacuum capacity: 18 litres/mim- Maximum depression: -75kPa (-563mmHg)Vacuum is created by a plastic piston and cylinder system, with four vacuum-creatingmodules (QuatroFlex™ technology).The membrane vacuum regulator permits accurate vacuum settings.Double overflow-protection system (bottle and pump).Working temperature range: +5 to +40°C. 191 Microscope Technical SpecificationsSl Name TechnicalSpecsquotedby bidderBiddersDeviationif any3.1 Body :Binocular, sturdy, stable base body with focus adjustment controls3.2 Eye piece :Paired, high quality, (the image of the object as seen throughthe binocular eyepiece should be well defined centrally in at least 2/3field of view), achromatic, widefield, 10x without inbuilt pointer. Theeyepiece should be aplatanic and have a minimum field number of 18.Diopter adjustment must be present on one/ both eye pieces or on theeye piece tube3.3 Objective :Three objectives10x,40x,100x,10x and 40x objectives should have numerical apertures of 0.25 and 0.65respectively and should be of spring loaded type or otherwise.100x should have numerical aperture of 1.25 and should be of oilimmersion and spring loaded type. Suitable prominent marking should beprovided on 100x for easy identification.Unbreakable containers to be provided for storing the objectives. Allobjectives should be wide field, achromatic and parfocal.Making for the Objectives :Each objective should be engraved with thefollowing informations:-• Name of the manufacturer• Magnification and numerical aperture, for example, 10x/0.25• 100x objective should be engraved with the word ‘Oil’in changing from one objective to another or reintroducing the sameobjective by rotation of the nosepiece, the object at the center of thefield should not appear displaced by more than 0.02 mm in the objectplane in any direction.3.4 Nose piece:Revolving nose piece to accommodate a minimum of threeobjectives with click stops. It should be provided with ribbed grip for easyrotation mounted on a precision ball bearing mechanism for smooth andaccurate alignment. Extra ports if any should be fitted with dust proofmetallic/ebonite caps.3.5 Stage Uniformly horizontal, mechanical stage having dimensions oflength 140 mm (+/- 20mm) with fine vermier graduations (minimumreading accuracy of 0.1 mm). the stage should be provided with springloaded slide holder for exact positioning of specimen/ slide. It should bedesigned with convenient sub-stage vertical coaxial adjustment for slidemanipulation. The stage should have ball-bearing arrangement to allowsmooth travel in transverse directions i.e. 80 mm (+/-5mm) and front toback direction, 50mm (+/-5mm)3.6 Sub-stage condenser:Abbe-type condenser, numerical aparature (N.A.)1.25 focusable with rack and pinion arrangement incorporating anaspherical leps and an iris-diaphragm. The condenser should have a filterholder and removable/ swing in/ out blue filter (suitable for bright fieldMicroscopy).3.7 Sub-stage illuminator: 1.The system should have a build-in variable lightsource (Illuminator). This light source should have a 20 W, 6 V Halogenlamp. The circuitry for the light source should include a constant voltagesupply. The system should be provided with a step down transformer andan on-off switch and intensity control. The lamp should be provided witha lamp socket which has the facility for easy replacement of the bulb,2. Power Supplya. Voltage 220 V, 50 Hz ACb. Should have one on-off power switch, 3 core power cord with a 3 pointmale plug.3. The system should have an inbuilt protective/ safety device towithstand fluctuations of voltage from 140 V to 280 V4. A plano-concave mirror in fork mounting should be supplied whichwould be attachable to the base for field use. (where power is notavailable).5. The fuse for the halogen lamp should be easily accessible to theoperator6. The Illuminator should have a build-in field diaphragm for Kohlerillumination3.8 Eye piece tubes:Binocular eye piece tubes, inclined at 45 degrees,rotatable through an angle of 360 degrees, having inter-pupullarydistance range of 54-74 mm or wider, covering the above mentionedrange3.9 Focusing knob:Co-axial coarse and fine focusing knobs capable of smoothfine focusing movement over the full range of coarse travel. The finefocusing movement should have sensitivity of two microns or less (finer)over the entire coarse focusing stop safety arrangement should beprovided.3.10 General 1.All optical parts including objectives, eye pieces and prismsshould have anti-reflective coating which also gives anti-fungal property.2.All metallic parts should be corrosion-proof, acid-proof and stain-proof3.Working manual should be provided with each microscope4.A bottle of at least 25 ml immersion oil, a roll of lens tissue paper andlens cleaning solution (100 ml) should be provided with each microscope.5.One no.of anti static cleaning brush should be provided with eachMicroscope for cleaning purpose.6.Each Microscope should be supplied with Blue filters. The Blue filtershould be packed in the ox and not fixed on the Microscopes. 4 System Configuration Accessories, spares and consumablesSl Name TechnicalSpecsBiddersDeviationquotedby bidderif any4.1 System as specified-4.2 Each microscope should be supplied with spare parts as under:•100x oil immersion objective (as per the specifications given under B3) –one.•Halogen bulb, (6volts, 20w) – 6 Nos.•Fuses – 6 Nos.4.3 All consumables required for installation and standardization of system tobe given free of cost. 192 Truenat Machine 3. Equipment and site preparationAn essential step of the implementation process is the selection of instruments to fit theneeds of the testing algorithm, anticipated workload and intended setting of use theTruenat TB tests. Laboratories should select the appropriate number and models ofTruelab micro PCR Analyzers to match anticipated demand (see Table 4 for estimationof throughput). Note that the ability of a testing site to utilize all of the capacity ofa workstation may not be an important factor for selecting Truenat TB testing sites, especially considering that the Truenat TB test isdesigned to be placed at peripheral microscopycenters.All instruments must be documented to be “fit forpurpose” through testing with known positive and/or negative material prior to commencing testingof clinical specimens.Planning for service and maintenanceTruelab and Trueprep instruments require minimalpreventive maintenance as per the manufacturer.For an example of a preventive maintenance logthat shows routine daily and monthly activitiesas well as ad hoc activities to be conducted asnecessary, see Annex 4.The manufacturer offers warranty packages forequipment service and maintenance includingthrough its growing network of in-country serviceproviders. Annual warranties that providecomprehensive service and maintenance includingon-site visits are available through the Stop TBPartnerships Global Drug Facility (GDF); seethe GDF Diagnostics Catalog for more details.Countries planning to implement Truenat shouldinform the manufacturer in advance to allow themanufacturer to plan as needed for expansion ofits network of service providers.Site preparation and assessment of readinessAs part of the situational analysis, each of theselected testing sites will have been evaluatedfor suitability for conducting Truenat TB testingusing a standardized checklist (see Annex 6). Keyinfrastructure and operational considerations forsite preparation include:• Power: In-built batteries in both devices allow fortesting without power for up to 8 hours; deviceswill not allow for a cycle to start if battery poweris too low. Batteries are expected to last fiveyears. Note that power is still required to chargebatteries: recharging time is approximately 4hours for the micro PCR analyzers, 9 to 10 hoursfor the Trueprep device and 4 to 6 hours for themicro printer. Use of instruments while chargingis possible, when the electrical socket is wellgrounded. The devices are able to operatewithin the 100-240 voltage range; no additionalvoltage stabilization is required in settings withinstabilities or low voltage. Solar panels maybe a solution for settings without any access topower (see Box on specifications). Power mayalso be required to possibly cool the storageroom for test chips; as described below, chipsshould be stored at ≤30°C.Activities at a glance□ Select, procure, install and set-upequipment□ Verify the instruments are fit for purpose□ Arrange for preventive maintenanceand servicing□ Prepare site infrastructure for Truenatinstruments and testing□ Ensure a safe and functional testingsiteSuggested specifications of a solar panelas per the manufacturer:• Panel: 150 Watts. Dimensions (LxWxH):1490 x 665 x 35 mm• Battery: 12V 18Ah Lead Acid• Solar Charge Controller + DC to DCboost converter (12V to 170V, 100 Watts)Controller and converter available fromMolbio; panel, battery and installation tobe locally sourced. 193 Ice Lined RefrigeratorILR can maintain a temperature from +2°C to +8°C with as little as 8 hours of power supply in 24 hours 194 Audiometer Air conduction Audiometry (125-8000Hz) Bone conduction Audiometry 195 Bio Chemistry AnalyzerGeneral Information Machine TypeTest Speed Test Principle Test Method Calibration Type : Random access: Constant 200 tests/hour (Mono Reagent or Double Reagent): Colorimetric method, turbidimetry, Immuno turbidimetry: 1 Point End, 2 Point End, Fixed Time and Kinetics: Linear and Non Linear 1 Point Linear, 2 Point Linear, ExponentialLogi - 10g, 3P, 4P, Multi-point Linear, Spline, Line Graph Sample UnitReagent UnitReaction Unit Sample Tray Sample TubeSample Volume Sample ProbeSample Barcode Reagent TrayReagent VolumeReaction Tray Reaction Volume : 40 Sample Positions: Micro Cup & Test Tube & Blood Collection Tube (Ф 12 - 13) mm * (25 - 100) mm: 2 - 30µL, Step by 0.1 µL: Liquid surface detection, timely tracking for liquid volume Collision Protection: Sample barcode reader (Option): 40 Reagent Positions (40 for R1 or 40 for R2) 24 hours cooling system with paltier pad inside: 20 – 300 µL, Step by 1 µL: 44 reaction new pyrex cuvettes, perfect transmittance: 150µL - 330µL Mixing system Mixer : Paddle-type mixing, effective and reducing carryover Optical SystemOperating system Light Source Wave LengthAbsorbance Range ResolutionOperating System Report Printing Interface : Halogen Lamp: 340nm; 405nm; 450 nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options): 0 – 4.0 Abs: 0.0001 Abs: Windows XP, Windows 7, Windows 8, Windows 10: 6 Formats Optional, Support Custom Formats: Pattern, TCP/IP network Interface Working Conditions Power Supply : AC 110/220V ± 10%, 50/60 Hz, 1000VAWater consumption : 8L/hour (maximum) Dimension Weight : 750mm * 550nm * 490mm (L*W*H): 70 kgs Power Supply 110/220V ± 10%, 50/60 Hz, 1000VA,Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA 196 Blood Donor Couch Comfortable chair type with soft padding for cushioning and rexin cover.Seat, back rest and leg rest size designed for donor comfort.It should have step less electric remote controlled height adjustment approximately 58 – 60 cm.Adjustable arm rest for donor’s comfort and phlebotomist friendlyEasily tilted to head low position, electrically operatedComfortable working level for the operator. Lifting capacity - Approx 200 kg.4 Lockable castors for easy mobilityStorage Drawers for storing consummables & Blood Collection MonitorsUP/DOWN controlOPTIONS: 1.A paper roll holder can be fixed on the upper part of the chair. 2.Melodious musical Headphone can be integrated for patient relaxation while blood donation is in progress 197 BP Apparatus Digital 198 Cautery Machine SPECIFICATIONS FOR CAUTERY MACHINE(HIGH-END SURGICAL ELECTROCAUTERY WITH VESSEL SEALER)High-End Electro Surgical Unit with Vessel Sealer Unit should be comprised of:1. An integrated RF Electro Surgical Unit (For electrosurgical Cut & Coagulation modes for the optimum effectof HF surgery)2. Vessel Sealer (For sealing vessels & tissue structures, during open and laparoscopic surgeries).A) Electro Surgical Unit should be microprocessor controlled, US-FDA &/ European Certificate marked inaccordance with the medical devices directive (93/42/EEC) 4 Digit notified & Electro Surgical Unit shouldcomply with the requirement of the medical devices directive of class 1 equipment and electromagneticcompatibility.B) Electro Surgical Unit quoted should have a very strong Installation base- must be provided a minimum of 50installation base in India.C) Special bipolar mode for coagulation of vascular tissue (Vessel Sealing) up to 7 mm with Reusable/Disposable Hand Instrument for open as well laparoscopic surgeries & should have 510 K approval for 7 mmVessel.D) The system should have Monopolar Cut & Coagulation Mode, two Bipolar Modes with auto bipolar start &stop and Vessel fusion technology all integrated in one system. Should have around 8 Cutting Modes &around 8 Coagulation Modes.E) The equipment should be micro controller based & should adjust the power to get the desired surgical effecton the tissue. All settings should be controlled by the machine and according to the tissue deliver. Powershould be display on the screen with graph facility to show the deliver poweF) Should have Power and Voltage automatic regulation feature to prevent tissue damage and charring. Theoutput voltage should be regulated at various levels.G) The System should have LCD/ LED Backlight adjustment for good visibility in operating room, patient platemonitoring facility, audio-visual alarm, and deactivate output if contact between patient and patient plate isnot proper to eliminate the risk of patient burns.H) Should have optional facility of connecting reusable contact quality Monitoring Return Electrode Pediatric /Adult with 100% washable foot switches (for terminal cleaning & disinfection)- Monopolar & BiopolarI) The high End Electro Surgical Cautery Unit with Vessel fusion technology should be compatible with theintegration system of OR mainly O.E.M.’s like – Karl Storz, Olympus & De Vincy.J) The high-End Electro Surgical Cautery Unit with Vessel fusion technology should be supplied along withessential accessories from the same original equipment manufacturer, affidavit for the same has to besubmitted by the bidder, else bid will be rejected.1. Open and Laparoscopic Surgery Vessel seal instrument with cord. Reusable (which has certificate for theminimum shelf life of 50 applications and should be autoclavable- 01 each (Open & Lap) and ifDisposable 50 each (Open & Lap).2. Diathermy Pad/ Patients plate- adult/ pediatrics with patient plate cable if Reusable- 01 with a shelf lifeof minimum 50 applications and if disposable 50 pcs3. Monopolar two pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) withminimum shelf-life of 1000 applications or 24 months from date of supply-1no.4. Bipolar one pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) with minimumshelf-life of 1000 applications or 24 months from date of supply-1no.5. Monopolar electrosurgical pencil with different electrodes either Reusable 01 Unit with reusable 05electrodes of various shapes with a shelf life of minimum 50 applications or Disposable- 50 Units6. Nonstick Bipolar forceps Straight & bayonet each with bipolar cord for forcep either Resuable 01 Unitwith a shelf life of minimum 50 applications or Disposable- 50 Units7. Reusable universal adaptor for attaching several Laparoscopic hand instruments with a shelf life of aminimum of 50 applications-1no.8. Cart with Castors with unconditional replacement if break within 05 years from the date. 199 Centrifuge 12 Tube 200 DVT Pump Deep Vein Thrombosis (DVT PUMP)• Size: 6.5” L x 7.0” W x 12.8” H• Weight: 2.5kg• Pressure Settings:• Calf/Thigh sleeve: 30, 40 (default), 50, 60 mmHg ; +10/-5mmHg Foot sleeve: 120 mmHg ; +10/-5mmHg• Input Rating: AC 100V-240V 50/60 Hz, 0.2A-0.55A• Fuse Rating: 1A, 250V• Appliance Class: Class I, Type BF• Not AP or AGP type• Classification to FDA: Class II• Classification to CDSCO: Class B• Humidity: Operation 30% to 75 %• Storage & Transportation 30% to 75%• Air pressure: 4 – 16 kPA• Temperature: Operation 15° - 35° C• Storage & Transportation 5-60 degree C• Cycle Time: Inflation 12 seconds +/- 10%• Deflation: 48 seconds +/- 10% 201 Prolene Suture Size 2-0 202 Prolene Suture Size 1-0 203 Prolene Suture Size 3-0 204 Nylone Suture 2-0 205 Disposable Hemorrhoidal Circular Stapler 32mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 206 Disposable Hemorrhoidal Circular Stapler 34mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 207 Silk suture, USP 3-0, 70 cm, needle: 26*1*2 mm, reverse cutting, 3/8 circle. 208 Ethicon Ethilon Sutures USP 4-0, 3/8 Circle Reverse Cutting - NW3326 209 Nylone Suture 3.0 210 Botroclot Solution 211 Disp.LinearCutter 60 212 Disp.LinearCutter 80 213 Disp.LinearCutter 100 214 Disposable Curved Circular Stapler 29mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 215 Disposable Curved Circular Stapler 31mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 216 Acetylsalicylic Acid (Aspirin)*(Tablet 25 mg),Tablet [202209005] 217 Allopurinol(100mg),Tablet [110034] 218 Artemether + Lumefantrine(20mg+120mg),Tablet [110149] 219 Bisacodyl(5 mg),Suppository [110294] 220 Boro-Spirit Ear Drops-(0.183 gm Boric Acid in 2.08 ml of Alcohol 10 ml vial),Drop [202209052] 221 Charcoal Activated (Powder)(100 gm box/pouch),Oral Powder [110051] 222 Ciprofloxacin Eye Ointment 0.3% ( 3gm Tube) [4460001] 223 Clofazimine(Tablet 50 mg 4),Tablet [202209022] 224 Cloxacillin(500mg),Capsule [120092] 225 Cloxacillin(Capsule 125 mg),Capsule [202209020] 226 Codeine(Oral Solution 15 mg/5 ml 60 ml bottle),solution [202209080] 227 Diethylcarbamazine(Oral Liquid 120 mg/5 ml 100 ml bottel),Liquid [202209023] 228 Diloxanide Furoate(Tablet 500 mg),Tablet [202209024] 229 Diphenylhydantoin(Tab 30 mg 10x10),Tablet [202209013] 230 Dispersable Tablet Hydroxyurea (100 mg 10x10),Tablet [202209073] 231 Finofibrate(Tablet 40 mg),Tablet [202209041] 232 Fluphenazine 1 ml Amp(25 mg / ml),Injection [120354] 233 Glycopyrolate(Inj 0.2 mg/ ml 1 ml vial),Injection [202209001] 234 Gum Paint (Tannic Acid)(2% w/v 15 ml bottle),Bottle [202209046] 235 Halothane BP 250ml [4000001] 236 Hepatitis B Immunoglobulin(100 IU/Vial),Vial [110319] 237 Human Chorionic Gonadotropin(Injection 10000 IU vial of 1 ml injection),Injection [202209062] 238 Human Chorionic Gonadotropin(Injection 5000 IU vial of 2 ml injection),Injection [202209063] 239 Hydroxyethyl(6% Saline solution for infusion)(Starch 6%IP 500 ml Bottel),Infusion [202209083] 240 Imipramine(25 mg),Tablet [110360] 241 Insulin soluble Inj. - 40 IU/ml [4350097] 242 Ipratropium Bromide inhaler 20mcg per puff(200 metered dose container),Inhaler [1100376] 243 Isoxsuprine(10mg),Tablet [120174] 244 IV Human Immunoglobin 5% IV IG((5mg/100ml Each),Injection 100ml injection),Injection [202209067] 245 Ketamine hydrochloride(10mg/ml (10ml vial)),Injection [110003] 246 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 10 mg (B) CR),Tablet [202209033] 247 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 25 mg (B) CR),Tablet [202209034] 248 Levodopa (A) + Carbidopa (B)(Tablet 250 mg (A) + 25 mg (B)),Tablet [202209035] 249 Levosalbutamol(50mcg/dose 30 capsule in 6 pack with 1 dispecing device),Capsule [202209070] 250 Levosulbutamol(100 mcg 30 capsule in 6 pack with 1 dispecing device),Capsule [202209069] 251 Lithium Carbonate(300 mg),Tablet [110358] 252 Lorazepam2 mg / ml1 ml Vial [110369] 253 Losartan(10 mg Tablet),Tablet [202209057] 254 Medroxyprogesterone acetate(Injection 150 mg 1 ML / VIAL),Injection [202209064] 255 Methyldopa Tab. - 250mg [4710040] 256 Morphine(Injection 15 mg/ml 1 ml ampule),Injection [202209081] 257 Noraderanaline Bitartrate(2 Mg Base/2ml (2ml Amp)),Injection [700472] 258 Normal Saline(Nasal Drops: Sodium Chloride Drops 0.05% w/v 10 ml vial),Drop [202209053] 259 Ormeloxifene(Tablet 30 mg 10x10),Tablet [202209065] 260 Phenobarbitone(200 mg/ml),Injection [110060] 261 Pilocarpine Eye drops 2%(5ml),Vial [110327] 262 POMALIDOMIDE(Cap 2 mg),Capsule [202209031] 263 Pralidoxime (PAM) Inj(25 mg/ml),Injection [4350085] 264 Premix Insulin(30:70 Injection (Regular: NPH)2 vial of 100 ml),Injection [202209066] 265 Promethazine(Injection 10 mg/ml 2ml vial),Injection [202209002] 266 Protamine(Injection 50 mg/5 ml 5 ml vial),Injection [202209044] 267 Pyridoxine Tab 10mg [4710380] 268 Sodium Aminosalicylate Granules(10 gm Bottel of 100 gm),Powder [202209028] 269 Sucralfate (20 mg Tablet 10 x 10),Tablet [202209058] 270 Surfactant Suspension(Inj 25 mg/ml),Injection [202209077] 271 Tab Mebeverine(Tab 200 mg 10 x 15),Tablet [202209056] 272 Tamoxifen tab.(10 mg),Tablet [4710305] 273 TOPOTECAN(Inj 4 mg 4 ml vial),Injection [202209032] 274 Verapamil(Injection 5 mg/2 ml 2 ml vial),Injection [202209045] 275 Alpha-Beta Arteether Inj 75 mg / 2 ml [700153] 276 Ampicilline 125mg/30ml Syrup [987655] 277 Antacid Chewable Tablet containing Aluminum hydroxide equivalent to dried gel 250mg+ Magnesium hydroxide 250mg+ Simethicone 50mg USP [4710419] 278 Benzyl benzoate emulsion( emulsion),Emulsion [4220001] 279 Calcium Syp 100ML Syrup (240mg/5 ml) [987642] 280 Cefpodoxime200 mg + Ofloxacine 200mg Tab.(200+200),Tablet [120980] 281 Cetrimide + Choline Salicylate Gel for oral ulcer 15ml Tube [4760001] 282 Cetrimide Cream BP(0.1% w/w),Tube [4760003] 283 Chloramphenicol 0.5%(5ml),Eye Drop [120073] 284 Tab Ciprofloxacin 250 + Tinidazole 500 mg 285 Tab Ciprofloxacin 500 + Tinidazole 600 mg 286 Chlorhexidine 0.2% Mouth Gargle(100 ml),solution [4630028] 287 Clobetasol 0.05% + Gentamicin 0.1% Cream 10 gm(10 gm tube),Cream [120082] 288 Cyproheptadine HCL + Tricholine Citrate(2mg + 275 mg / 5 ml (100ml Bottle)),Syrup [120098] 289 Dicyclomine Syrup [987647] 290 Digestive Drop ( Digestive Enzyme And Multivitamin with L Lysine )( 15 ml),Drop [987868] 291 Domperidone +Ranitidine 150mg Tab [987691] 292 Doxylamine Succinate + Pyridoxine(10mg+10mg),Tablet [120117] 293 Gentamicin Inj. - 40 Mg/Ml, 2ml AMP [987917] 294 Insulin Human Mixtard inj. - 30:70( ),Injection Solution for [4350096] 295 Ipratropium Bromide Powder for inhalation 250mcg/ml [4330004] 296 Ketoconazole Tab [4710123] 297 Lignocaine Hydrochloride Topical Solution USP(2%),Vial [4790014] 298 Magnesium Sulphate Powder(400gm),Powder [20201043] 299 Nepafenac ophthalmic(Suspension 0.1%),Eye Drop [140099] 300 Nepafenac(1mg/ml),Eye Drop [120685] 301 Nifedipine (Sublingual)(10 mg),Capsule [120548] 302 Oseltamivir H1 N1 Antiviral syp 75 mg [700120] 303 Paracetamol + Chlorphenaramine+ Phenylephrine(250 mg + 2.5 mg + 10 mg),Tablet [120560] 304 Paracetamol + Phenylephrine + Chlorpheniramine Maleate (125mg+2.5 mg+1mg) /ml(15 ml Bottle with Dropper),Drop [120561] 305 Paracetamol 100 mg/ml, 150 ml Drop(150 ml),Consumable [987903] 306 Paracetamol 75 mg/ml(10 ml Inj),Injection [987904] 307 paracetamol drop(100 mg/ml),Drop [4700041] 308 Pentoprozole 40mg +Domperidone 10mg Tab [987675] 309 Peptonised Iron 176.5 mg(Equivalent to 30 mg of Elemental Iron,Protein (as Peptone) 100 mg,Folic Acid 200 mcg, Vitamin B12 2.5 mcg 100ml),Bottle [20200910] 310 Piroxicam(ointment),Ointment [10000] 311 Prednisolone(10 mg/ml),Eye Drop [120259] 312 Roxithromycin 150mg Tablet [987689] 313 Sodium Chloride (Ophthalmic) 5%(10 ml),Eye Drop [120596] 314 Sodium Hyaluronate (Intraocular)(10 mg /ml 2ml),Injection [120597] 315 Syp. Cefodroxil 125mg/30mlSyrup [987657] 316 syrup cefpodoxime(50 mg),Syrup [700426] 317 Visco Gel for eye department 318 BSS Solution For Opthalmic Use 319 Lignocaine 4% heavy 320 Tetanus Toxide inj 5ml( ),Injection Solution for [4350104] 321 TetracyclineEye Ointment 1% 5 gm [120603] 322 Flurbiprofen Sodium 0.03%(5 ml),Eye Drop [120492]

BOQ

Name of Work:
Sl. No. Item Description
1Type c category equipments, furniture, implants and medicines
2Autoclave Surgical drum SS-Size 15*12 approx
3Autoclave Surgical drum SS-Size 9*9 approx
4Autoclave Surgical drum SS-Size 11*9 approx
5Autoclave Surgical drum SS-Size 11*5 approx
6OT Trolly (Dressing)
7Supra Pubic Trocar 12 No
8Supra Pubic Trocar 8 No
9Supra Pubic Trocar 14 No
10Tooth Forcep & Non Tooth Forcep Midium Size
11Suture Cutting (Micro)
12Mayo Scissors (Carved) Midium
13Nebular (Bone Cutter)
14Sharp Scissors 9.0ml
15Tissue Cutting Scissors Carved Midium
16Mosquito artery big Size
17Mosquito artery Medium artery
18Gigli Saw vial
19Bone Saw Big
20Hegars Dilator set
21Biopsy Gun
22H.B Skin grafting handle
23Bull dog
24clamp
25Suction Cannula disposable
26O.T. Light double dome
27Cautery Pin
28Triway catheter No 20
29Urinary Cathetor No 12,
30Urinary Cathetor No 14
31Urinary Cathetor No 10
32K-90 Catheter
33Tommy Syringe
34Hperdomic Needle No 16
35Hydrogen Peroxide (500ml)
36Small Tooth
37Non Tooth forcep
38Bone Vax
39Senetizer
40Disposable Syrienge 2ml
41Disposable Syrienge 5ml
42Disposable Syrienge 10ml
43Disposable Syrienge 20ml
44Uro Bag
45Adhesive Tape Roll 4 \"
46Paper Adhesive Roll PER Pack
47Gloves No 6.5
48Dressing Disposeble Gloves
49Spinal Needle
50Ven flow No 20
51Suction Tube
52Oxygen Key
53Oxygen Flow Meter Set
54Vicryl 3.0 Round body
55Vicryl 2.0 ½ cr RB Needle 30mm
56Vicryl 3.0 ½ cr RB Needle 22mm
57Vicryl 3.0 ½ Cutting Needle
58Vicryl 1 ½ cr RB Needle 36mm
59Vicryl 1.0 ½ cr RB Needle 30mm
60Ethilon 1. 0 ½ cutting Needle 36mm
61Ethilon 2. 0 3/8cutting Needle 36mm
62Ethilon 3. 0 3/8cutting Needle 36mm
63Silk – 1.0
64Silk – 2.0
65Silk – 3.0
66Hydrogen peroxide 6% 400ml
67Butroclot solution
68Drain sheet (Currugeted)
69Sumag Ointment
70Dis. Needle 16no,
71K90 Katheter
723 way stop cock with extension line
73Needle 24x1 ½
74Lignocain 4% vail
75Endotrachial Tube 7.5cm
76Endotrachial Tube 8.5cm
77Poly Propylene 2.0 1/2 cr RB Needle 30mm
78Surgical Cap
79Chair S TYPE
80Abdomans Spange 20\" X20\"\"
81Tailar Scisor
82Feetal Doplar DIGITAL
83Nebulization Machine
84Giuco Meter
85BP Instrument \"standmodal
86BP Instrument Digital
87Palse oximeter tabel Top
88fogging Machine
89Digital Tharma meter
90Baby Tray
91Autoclav drum
92Gyser 20 LITER isi MARK
93Wheel Chair
94Digital Watch
95O2 Flow Meter
96Kideny Tray 8\"
97Doctor Chair
98Sizzer 8\"\"
99Epigiotomy Sizzer
100Hand Wash 500 ml
101dispossable syrienge 50ml
102dispossable syrienge 20ml
103dispossable syrienge 10ml
104dispossable syrienge 5ml
105dispossable syrienge 3ml
106dispossable syrienge 2ml
107Follyes Cathetar 16 No
108Endotrachial Tube 2cm
109Endotrachial Tube 2.5cm
110Endotrachial Tube 3cm
111Endotrachial Tube 3.5cm
112Endotrachial Tube 5cm
113Endotrachial Tube 6cm
114Endotrachial Tube 7cm
115Endotrachial Tube 7.5cm
116Endotrachial Tube 8.5cm
117Endotrachial Tube 8cm
118Air Pressure Line
119O2 mask
120NRBM Mask
121Flatus Tube
122Glucometer Strip
123Albumin Strip
124UTP Kit
125Celispaid
126Senitary Pad
127Ambu Bag Adult
128Ambu Bag pediatric
129mettress 4\"\" (6 x3) fom with cover
130Baby Diper
131Ventilator Tube
132Pediatric dreep set
133IV Stand SS 4 Wheel
134Oxygen Key
135Sterlizer Medium Size
136Chair office
137Steel Tray with Cover
138Nebulization Mask
139Refrigerator 180LIT
140Strature with wheel
141Lade Aprone
142Nasalprobe Child
143Nasalprobe Adult
144Mayo sizzer
145Fine tooth Forcep
146tooth Forcep big
147Step StoolMS 2 Step
148Pattela Holding Forcep
149Bone Cutter
150Giggli Wire
151T- Handel
152Tubalring
153Mucous Extractor
154Caord clamp
155Baby Tag
156Romo Vac sizes of10, 12, and 14 FGbellow unit capacity is 800 ml.curved Needle Length is 175 cm.
157Pules oximeter tabal Top
158Weight Machine Adult
159Enfusion Set
160PPE Kit
161Feeding Tube 5 no
162Feeding Tube 6 no
163Feeding Tube 7 no
164Feeding Tube 8 no
165P.M.O. Line
166Adult Nosal Prong
167Water Cooler 40 Litter
168Urine polmale
169Tuning fork (256)
170Stop Watch
171Percussion hammer
172omce Table
173Office Dustbin
174LED Torch
175Iron Almiraha \"6\"
176DigitalClock
177FUJI PRINTER DRY IMAGING FILMOBX 10 DIGITAL X-RAY FILM
178DISTAL REDIUS T,T OBLIQ PLATE (SIMPLE)
1793.5 MMLOCKING CLEVICALPLATE ( 5 TO 8 HOLE )
1803.5/2.7 MMLOCKING CLEVICAL SUPERIALPLATE (5 TO 8 HOLE)
181ADWANTEG SYRING
182Illizarov Set
183Modular Bipolar Set (1 Cese)
184Blood Bank Refrigerator Technical specifications: Blood bank refrigerator1- Blood bank refrigerator – capacity 100 blood bags or more with two or more shelves.... 2- Inner chamber made of stainless steel, outer chamber made of powder coated steel sheet with high quality insulation material between the walls.3- Microprocessor based temperature controller with preset temperature 4 degreecentigrade plus minus 1 degree centigrade .and digital temperature display. 4- 50 htz 220-240 volts Ac power supply (single phase power supply in India). 5- Audio-visual alarm for low (less than 2 degree centigrade) and high (more than 8 degree centigrade) temperature.. 6- 7 day circular temperature chart recorder- in built.. 7- Air circulation fan. 8- Light bulb inside chamber. 9- Auto defrost mechanism or frost free, CFC free. 10- In built line voltage corrector 11- Vendor has to support the specifications with manufacturer’s brochure failing which offer may be rejected. Vendor has to demonstrate the equipment at BHEL General Hospital, Hyderabad within specified time limit, if asked for; failing which offer will be rejected.
185Blood Celll Counter Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC3 histograms for WBC, RBC and PLTPrediluted mode ≤20μL | Whole blood mode ≤9µL , 60 samples per hour10.4 inch TFT Touch ScreenChinese, English, Spanish, Portuguese, Russian, French, Bahasa, IndonesiaUp to 400,000 results including numeric and graphical information LAN Port supports HL7 protocol | Support bi-directional LIS4 USB ports (for external printer, software upgrade, barcodereader, external WIFI, keyboard and mouse), LAN port (1)Thermal recorder, 50 mm wide paper, various printout formats External printer optionalTemperature: 15°C~35°C | Humidity: 10%~90%Air pressure: 70kPa~106kPa(100V-240V)±10% through online UPS (rating 1 KVA)≤180VA | (50Hz/60Hz)±1Hz ,410(L) x 300(W) x 400(H) mm ; 20Kg
186DefibrillatorTECHNICAL SPECIFICATION OF DEFIBRILLATORDESCRIPTION of Function• Defibrillator is required for reviving the heart functions by providing selected quantum ofelectrical shocks with facility for monitoring vital parameters.Operational Requirements• Defibrillator should be Bi- Phasic, light weight and latest model• Should monitor vital parameters and display them• Should print the ECG on thermal recorders.• Should work on Manual and Automated external defibrillation (AED) mode. Manualselection up to 270 J.• Should be capable of doing synchronized & asynchronized cardioversion• Can be operated from mains as well as battery• Should have defibrillator testing facilityTechnical Specifications• Should be a Low Energy Biphasic defibrillator monitor with Recorder, having capability toarrest allarrhythmia within a maximum energy of 360 Joules• Should monitor ECG through paddles, pads and monitoring electrodes and Defibrillatethrough pads and paddles.• Should have Automatic Lead switching to see patient ECG through paddles or leads• Should measure and compensate for chest impedance for a range of 25 to 150 ohms• Should have a built in 50mm strip printer/ thermal recorder• Should have charging time of less than 3 seconds for maximum energy. Charging indicatorshould be there.• Should have bright electroluminescent display for viewing messages and ECG waveform of4 seconds• Should have external & internal paddles with paddles contact indicator – for good paddlecontact. Single Adult and pediatric paddles should be available.• Should have event summary facility for recording and printing at least 250 events and 50waveforms.• Should be capable of printing Reports on Event summary, configuration, self test, batterycapacity etc• Should have facility for self test/check before usage and set up function• Should have SP02 and NIBP integrated facility• Should have user friendly color coded operationEnvironmental factors• The unit shall be capable of operating continuously in ambient temperature of 10 -500 C andrelative humidity of 15-90%• The unit shall be capable of being stored continuously in ambient temperature of 0 -500Cand relative humidity of 15-90%• Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of Safety forElectromagnetic Compatibility.Power Supply• Power input to be 220-240VAC, 50Hz. Power cable should be fitted with Indian plug andadapter.• Resettable overcurrent breaker shall be fitted for protection• Should have a Rechargeable Battery capable of usage for at least 90minutes or 30discharges.
187Electrolyte Analyzer Method Sample Speed :-Multi-Biosensor TechnoloTechnology 60-120µlISE ≥ 80 tests / hour Printer Inner Thermal Printer Expand FunctionAmbient Conditions PowerPower Requirement RS232 & COM Connector, Computer and Barcode reader available0-40°C, Relative humidity ≤ 85% AC 80V ∼ 260V, 50-60Hz, ≤ 80WEarth Voltage <5V, Online UPS (230V)with isolated, transformers - 0.5 KVAParameters K+ Detection Range (mmol/L) 0.50 ∼ 20.00 Precision (CV)≤1.0% Resolution (mmol/L)0.01MeasureScope & Precision Na+ 15.0∼200.0 ≤1.0% 0.1 Cl- 15.0∼200.0 ≤1.0% 0.1 Ca+ 0.10∼200.0 ≤1.0% 0.01 pH 4.00∼9.00 ≤1.0% 0.01
188Elisa Reader WasherSpecifications for Microplate (ELISA) Reader1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD2. Should have linearity of ≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD; accuracy of ≤1.0%or 0.010 from 0.000–3.000 OD at 490 nm; precision of 1.0% or 0.005 OD from 0.0–2.0 OD;1.5% from 2.0–3.0 OD and resolution of 0.001 OD3. Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm includedfilters4. Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec5. Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths6. Should have onboard graphical thermal printer and USB2 interface with PC or Mac datastations for data output7. Should be able to store data for over sixty assay protocols8. System should come with a comprehensive software package allowing colorimetric andturbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix,normalization, and curve fit9. Software should have the functionality of flexible template creation for any microplate formatup to 1,536 wells10. Software should be either license free or license for minimum 5 systems should be providedSpecifications for Microplate washer Automatic washer compatible with strips and 96-well microplates that have flat-, U-, or Vbottom wells. Programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottomwashing, crosswise aspiration, and overflow washing. Dispensing speed control A plate shaking option to help minimize bubbles and adherence of liquid to well sides. Wash bottle sensor to detect high waste liquid levels Up to 75 programmable washing sequences Easily removable 8- or 12-way manifolds Easily accessible manifold interior for maintenance Removable and autoclavable plate carrier An aerosol protection cover Integrated vacuum and dispensing pumps to ensure accurate and quiet washing and toeliminate the need for external pumps. Residual well volume should be < 6 µl Wash bottle volume should be 2000 ml Soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes. Should come with 8-way manifold and 12-way manifold should be quoted in optional. On-board software should be capable of storing up to 110 wash protocols. Operating temperature 15-40 °C. Dimensions (WxDxH) not more than 35x43x20 cm Both instruments should be of from same manufacturer
189Semi-Automatic Biochemistry AnalyzersTechnical Specifications Human Machine Interface Touch Panel / Key Board / MouseLinear Measurement Range 0.000 to 3.000 Absorbance Units (A)Photometric Accuracy ±2% or 0.007 whichever is higher, from 0 to 2.0A, ±3% from 2.0A to 3.0ADrift <0.003A/hr.Optical Measurement Silicon Diode Filters Type of filterWave LengthHalf Bandwidth Filter SelectionFlow cell TypeFlow cell volumeSipping Volume Sipping Mode Cuvette Volume : Interference: 340,405, 450, 505, 546, 578, 630+2 Optional: ±2nm: By Stepper motor: Stainless steel body & Quartz Window: 32 μι: 300 to 1000 μι: Automatic by specially designed Peristaltic Pump: 500 μι Temperature of Cuvete/flow cell Block Method Temperature Light Source Warm up Time Display Printer Memory CPUBuilt in Incubator : By Peltier effect: 25°C, 30° C and 37° C: 6V/10W Tungsten Halogen lamp: 90 Sec.: 7\" TFT Display 300 x 930: Built in 55 mm, stationary head graphical thermal printer: DDR, & DRAN 1 GB, Flash 256 MB: ARN Cortex A8720 MHz: 2 Place for coagulation reagent | 15 Place for coagulation Cuvette 5 Place for test tubes Storage Capacity 2000 Open tests with 30 QC results/test (Normal and Abnormal controls)200000 Patient results with patient ID and GraphAnalysis Mode 1 point, 2 point (Sample blank) | Fixed time | Kinetic | CoagulationConcentration calculation : By factor or by standard Blanking PortPower WattageVoltage Operating Position : Water, Reagent: 4 USB, LAN Rj45: 100 Watts: 110-240 Volts ±10%, 50-60 Hz: On horizontal, flat, rigid and vibration free surface Operating Conditions Temperature Relative Humidity : from +18° C to 35° C: up to 85% Storage Condition Temperature Relative Humidity EnclosureSize (cm) Weight : from 10° C to + 60° C: up to 85%: ABS Fire retardant: 30X38X13.5 (LxBxH): 7.0 Kgs. (Approx)
190Suction MachineSpecificationsPortable suction unit: size 38x17x28.5cm, weight 5.1kgDescription (e.g.: model Vario A/C, manufacturer Medela)Technical specifications: SUCTION MACHINE with pump:- Power supply: 230-240V/50Hz- Vacuum capacity: 18 litres/mim- Maximum depression: -75kPa (-563mmHg)Vacuum is created by a plastic piston and cylinder system, with four vacuum-creatingmodules (QuatroFlex™ technology).The membrane vacuum regulator permits accurate vacuum settings.Double overflow-protection system (bottle and pump).Working temperature range: +5 to +40°C.
191Microscope Technical SpecificationsSl Name TechnicalSpecsquotedby bidderBiddersDeviationif any3.1 Body :Binocular, sturdy, stable base body with focus adjustment controls3.2 Eye piece :Paired, high quality, (the image of the object as seen throughthe binocular eyepiece should be well defined centrally in at least 2/3field of view), achromatic, widefield, 10x without inbuilt pointer. Theeyepiece should be aplatanic and have a minimum field number of 18.Diopter adjustment must be present on one/ both eye pieces or on theeye piece tube3.3 Objective :Three objectives10x,40x,100x,10x and 40x objectives should have numerical apertures of 0.25 and 0.65respectively and should be of spring loaded type or otherwise.100x should have numerical aperture of 1.25 and should be of oilimmersion and spring loaded type. Suitable prominent marking should beprovided on 100x for easy identification.Unbreakable containers to be provided for storing the objectives. Allobjectives should be wide field, achromatic and parfocal.Making for the Objectives :Each objective should be engraved with thefollowing informations:-• Name of the manufacturer• Magnification and numerical aperture, for example, 10x/0.25• 100x objective should be engraved with the word ‘Oil’in changing from one objective to another or reintroducing the sameobjective by rotation of the nosepiece, the object at the center of thefield should not appear displaced by more than 0.02 mm in the objectplane in any direction.3.4 Nose piece:Revolving nose piece to accommodate a minimum of threeobjectives with click stops. It should be provided with ribbed grip for easyrotation mounted on a precision ball bearing mechanism for smooth andaccurate alignment. Extra ports if any should be fitted with dust proofmetallic/ebonite caps.3.5 Stage Uniformly horizontal, mechanical stage having dimensions oflength 140 mm (+/- 20mm) with fine vermier graduations (minimumreading accuracy of 0.1 mm). the stage should be provided with springloaded slide holder for exact positioning of specimen/ slide. It should bedesigned with convenient sub-stage vertical coaxial adjustment for slidemanipulation. The stage should have ball-bearing arrangement to allowsmooth travel in transverse directions i.e. 80 mm (+/-5mm) and front toback direction, 50mm (+/-5mm)3.6 Sub-stage condenser:Abbe-type condenser, numerical aparature (N.A.)1.25 focusable with rack and pinion arrangement incorporating anaspherical leps and an iris-diaphragm. The condenser should have a filterholder and removable/ swing in/ out blue filter (suitable for bright fieldMicroscopy).3.7 Sub-stage illuminator: 1.The system should have a build-in variable lightsource (Illuminator). This light source should have a 20 W, 6 V Halogenlamp. The circuitry for the light source should include a constant voltagesupply. The system should be provided with a step down transformer andan on-off switch and intensity control. The lamp should be provided witha lamp socket which has the facility for easy replacement of the bulb,2. Power Supplya. Voltage 220 V, 50 Hz ACb. Should have one on-off power switch, 3 core power cord with a 3 pointmale plug.3. The system should have an inbuilt protective/ safety device towithstand fluctuations of voltage from 140 V to 280 V4. A plano-concave mirror in fork mounting should be supplied whichwould be attachable to the base for field use. (where power is notavailable).5. The fuse for the halogen lamp should be easily accessible to theoperator6. The Illuminator should have a build-in field diaphragm for Kohlerillumination3.8 Eye piece tubes:Binocular eye piece tubes, inclined at 45 degrees,rotatable through an angle of 360 degrees, having inter-pupullarydistance range of 54-74 mm or wider, covering the above mentionedrange3.9 Focusing knob:Co-axial coarse and fine focusing knobs capable of smoothfine focusing movement over the full range of coarse travel. The finefocusing movement should have sensitivity of two microns or less (finer)over the entire coarse focusing stop safety arrangement should beprovided.3.10 General 1.All optical parts including objectives, eye pieces and prismsshould have anti-reflective coating which also gives anti-fungal property.2.All metallic parts should be corrosion-proof, acid-proof and stain-proof3.Working manual should be provided with each microscope4.A bottle of at least 25 ml immersion oil, a roll of lens tissue paper andlens cleaning solution (100 ml) should be provided with each microscope.5.One no.of anti static cleaning brush should be provided with eachMicroscope for cleaning purpose.6.Each Microscope should be supplied with Blue filters. The Blue filtershould be packed in the ox and not fixed on the Microscopes. 4 System Configuration Accessories, spares and consumablesSl Name TechnicalSpecsBiddersDeviationquotedby bidderif any4.1 System as specified-4.2 Each microscope should be supplied with spare parts as under:•100x oil immersion objective (as per the specifications given under B3) –one.•Halogen bulb, (6volts, 20w) – 6 Nos.•Fuses – 6 Nos.4.3 All consumables required for installation and standardization of system tobe given free of cost.
192Truenat Machine 3. Equipment and site preparationAn essential step of the implementation process is the selection of instruments to fit theneeds of the testing algorithm, anticipated workload and intended setting of use theTruenat TB tests. Laboratories should select the appropriate number and models ofTruelab micro PCR Analyzers to match anticipated demand (see Table 4 for estimationof throughput). Note that the ability of a testing site to utilize all of the capacity ofa workstation may not be an important factor for selecting Truenat TB testing sites, especially considering that the Truenat TB test isdesigned to be placed at peripheral microscopycenters.All instruments must be documented to be “fit forpurpose” through testing with known positive and/or negative material prior to commencing testingof clinical specimens.Planning for service and maintenanceTruelab and Trueprep instruments require minimalpreventive maintenance as per the manufacturer.For an example of a preventive maintenance logthat shows routine daily and monthly activitiesas well as ad hoc activities to be conducted asnecessary, see Annex 4.The manufacturer offers warranty packages forequipment service and maintenance includingthrough its growing network of in-country serviceproviders. Annual warranties that providecomprehensive service and maintenance includingon-site visits are available through the Stop TBPartnership\"s Global Drug Facility (GDF); seethe GDF Diagnostics Catalog for more details.Countries planning to implement Truenat shouldinform the manufacturer in advance to allow themanufacturer to plan as needed for expansion ofits network of service providers.Site preparation and assessment of readinessAs part of the situational analysis, each of theselected testing sites will have been evaluatedfor suitability for conducting Truenat TB testingusing a standardized checklist (see Annex 6). Keyinfrastructure and operational considerations forsite preparation include:• Power: In-built batteries in both devices allow fortesting without power for up to 8 hours; deviceswill not allow for a cycle to start if battery poweris too low. Batteries are expected to last fiveyears. Note that power is still required to chargebatteries: recharging time is approximately 4hours for the micro PCR analyzers, 9 to 10 hoursfor the Trueprep device and 4 to 6 hours for themicro printer. Use of instruments while chargingis possible, when the electrical socket is wellgrounded. The devices are able to operatewithin the 100-240 voltage range; no additionalvoltage stabilization is required in settings withinstabilities or low voltage. Solar panels maybe a solution for settings without any access topower (see Box on specifications). Power mayalso be required to possibly cool the storageroom for test chips; as described below, chipsshould be stored at ≤30°C.Activities at a glance□ Select, procure, install and set-upequipment□ Verify the instruments are fit for purpose□ Arrange for preventive maintenanceand servicing□ Prepare site infrastructure for Truenatinstruments and testing□ Ensure a safe and functional testingsiteSuggested specifications of a solar panelas per the manufacturer:• Panel: 150 Watts. Dimensions (LxWxH):1490 x 665 x 35 mm• Battery: 12V 18Ah Lead Acid• Solar Charge Controller + DC to DCboost converter (12V to 170V, 100 Watts)Controller and converter available fromMolbio; panel, battery and installation tobe locally sourced.
193Ice Lined RefrigeratorILR can maintain a temperature from +2°C to +8°C with as little as 8 hours of power supply in 24 hours
194Audiometer Air conduction Audiometry (125-8000Hz) Bone conduction Audiometry
195Bio Chemistry AnalyzerGeneral Information Machine TypeTest Speed Test Principle Test Method Calibration Type : Random access: Constant 200 tests/hour (Mono Reagent or Double Reagent): Colorimetric method, turbidimetry, Immuno turbidimetry: 1 Point End, 2 Point End, Fixed Time and Kinetics: Linear and Non Linear 1 Point Linear, 2 Point Linear, ExponentialLogi - 10g, 3P, 4P, Multi-point Linear, Spline, Line Graph Sample UnitReagent UnitReaction Unit Sample Tray Sample TubeSample Volume Sample ProbeSample Barcode Reagent TrayReagent VolumeReaction Tray Reaction Volume : 40 Sample Positions: Micro Cup & Test Tube & Blood Collection Tube (Ф 12 - 13) mm * (25 - 100) mm: 2 - 30µL, Step by 0.1 µL: Liquid surface detection, timely tracking for liquid volume Collision Protection: Sample barcode reader (Option): 40 Reagent Positions (40 for R1 or 40 for R2) 24 hours cooling system with paltier pad inside: 20 – 300 µL, Step by 1 µL: 44 reaction new pyrex cuvettes, perfect transmittance: 150µL - 330µL Mixing system Mixer : Paddle-type mixing, effective and reducing carryover Optical SystemOperating system Light Source Wave LengthAbsorbance Range ResolutionOperating System Report Printing Interface : Halogen Lamp: 340nm; 405nm; 450 nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options): 0 – 4.0 Abs: 0.0001 Abs: Windows XP, Windows 7, Windows 8, Windows 10: 6 Formats Optional, Support Custom Formats: Pattern, TCP/IP network Interface Working Conditions Power Supply : AC 110/220V ± 10%, 50/60 Hz, 1000VAWater consumption : 8L/hour (maximum) Dimension Weight : 750mm * 550nm * 490mm (L*W*H): 70 kgs Power Supply 110/220V ± 10%, 50/60 Hz, 1000VA,Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA
196Blood Donor Couch Comfortable chair type with soft padding for cushioning and rexin cover.Seat, back rest and leg rest size designed for donor comfort.It should have step less electric remote controlled height adjustment approximately 58 – 60 cm.Adjustable arm rest for donor’s comfort and phlebotomist friendlyEasily tilted to head low position, electrically operatedComfortable working level for the operator. Lifting capacity - Approx 200 kg.4 Lockable castors for easy mobilityStorage Drawers for storing consummables & Blood Collection MonitorsUP/DOWN controlOPTIONS: 1.A paper roll holder can be fixed on the\" upper part of the chair. 2.Melodious musical Headphone can be integrated for patient relaxation while blood donation is in progress
197BP Apparatus Digital
198Cautery Machine SPECIFICATIONS FOR CAUTERY MACHINE(HIGH-END SURGICAL ELECTROCAUTERY WITH VESSEL SEALER)High-End Electro Surgical Unit with Vessel Sealer Unit should be comprised of:1. An integrated RF Electro Surgical Unit (For electrosurgical Cut & Coagulation modes for the optimum effectof HF surgery)2. Vessel Sealer (For sealing vessels & tissue structures, during open and laparoscopic surgeries).A) Electro Surgical Unit should be microprocessor controlled, US-FDA &/ European Certificate marked inaccordance with the medical devices directive (93/42/EEC) 4 Digit notified & Electro Surgical Unit shouldcomply with the requirement of the medical devices directive of class 1 equipment and electromagneticcompatibility.B) Electro Surgical Unit quoted should have a very strong Installation base- must be provided a minimum of 50installation base in India.C) Special bipolar mode for coagulation of vascular tissue (Vessel Sealing) up to 7 mm with Reusable/Disposable Hand Instrument for open as well laparoscopic surgeries & should have 510 K approval for 7 mmVessel.D) The system should have Monopolar Cut & Coagulation Mode, two Bipolar Modes with auto bipolar start &stop and Vessel fusion technology all integrated in one system. Should have around 8 Cutting Modes &around 8 Coagulation Modes.E) The equipment should be micro controller based & should adjust the power to get the desired surgical effecton the tissue. All settings should be controlled by the machine and according to the tissue deliver. Powershould be display on the screen with graph facility to show the deliver poweF) Should have Power and Voltage automatic regulation feature to prevent tissue damage and charring. Theoutput voltage should be regulated at various levels.G) The System should have LCD/ LED Backlight adjustment for good visibility in operating room, patient platemonitoring facility, audio-visual alarm, and deactivate output if contact between patient and patient plate isnot proper to eliminate the risk of patient burns.H) Should have optional facility of connecting reusable contact quality Monitoring Return Electrode Pediatric /Adult with 100% washable foot switches (for terminal cleaning & disinfection)- Monopolar & BiopolarI) The high End Electro Surgical Cautery Unit with Vessel fusion technology should be compatible with theintegration system of OR mainly O.E.M.’s like – Karl Storz, Olympus & De Vincy.J) The high-End Electro Surgical Cautery Unit with Vessel fusion technology should be supplied along withessential accessories from the same original equipment manufacturer, affidavit for the same has to besubmitted by the bidder, else bid will be rejected.1. Open and Laparoscopic Surgery Vessel seal instrument with cord. Reusable (which has certificate for theminimum shelf life of 50 applications and should be autoclavable- 01 each (Open & Lap) and ifDisposable 50 each (Open & Lap).2. Diathermy Pad/ Patients plate- adult/ pediatrics with patient plate cable if Reusable- 01 with a shelf lifeof minimum 50 applications and if disposable 50 pcs3. Monopolar two pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) withminimum shelf-life of 1000 applications or 24 months from date of supply-1no.4. Bipolar one pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) with minimumshelf-life of 1000 applications or 24 months from date of supply-1no.5. Monopolar electrosurgical pencil with different electrodes either Reusable 01 Unit with reusable 05electrodes of various shapes with a shelf life of minimum 50 applications or Disposable- 50 Units6. Nonstick Bipolar forceps Straight & bayonet each with bipolar cord for forcep either Resuable 01 Unitwith a shelf life of minimum 50 applications or Disposable- 50 Units7. Reusable universal adaptor for attaching several Laparoscopic hand instruments with a shelf life of aminimum of 50 applications-1no.8. Cart with Castors with unconditional replacement if break within 05 years from the date.
199Centrifuge 12 Tube
200DVT Pump Deep Vein Thrombosis (DVT PUMP)• Size: 6.5” L x 7.0” W x 12.8” H• Weight: 2.5kg• Pressure Settings:• Calf/Thigh sleeve: 30, 40 (default), 50, 60 mmHg ; +10/-5mmHg Foot sleeve: 120 mmHg ; +10/-5mmHg• Input Rating: AC 100V-240V 50/60 Hz, 0.2A-0.55A• Fuse Rating: 1A, 250V• Appliance Class: Class I, Type BF• Not AP or AGP type• Classification to FDA: Class II• Classification to CDSCO: Class B• Humidity: Operation 30% to 75 %• Storage & Transportation 30% to 75%• Air pressure: 4 – 16 kPA• Temperature: Operation 15° - 35° C• Storage & Transportation 5-60 degree C• Cycle Time: Inflation 12 seconds +/- 10%• Deflation: 48 seconds +/- 10%
201Prolene Suture Size 2-0
202Prolene Suture Size 1-0
203Prolene Suture Size 3-0
204Nylone Suture 2-0
205Disposable Hemorrhoidal Circular Stapler 32mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm
206Disposable Hemorrhoidal Circular Stapler 34mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm
207Silk suture, USP 3-0, 70 cm, needle: 26*1*2 mm, reverse cutting, 3/8 circle.
208Ethicon Ethilon Sutures USP 4-0, 3/8 Circle Reverse Cutting - NW3326
209Nylone Suture 3.0
210Botroclot Solution
211Disp.LinearCutter 60
212Disp.LinearCutter 80
213Disp.LinearCutter 100
214Disposable Curved Circular Stapler 29mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm
215Disposable Curved Circular Stapler 31mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm
216Acetylsalicylic Acid (Aspirin)*(Tablet 25 mg),Tablet [202209005]
217Allopurinol(100mg),Tablet [110034]
218Artemether + Lumefantrine(20mg+120mg),Tablet [110149]
219Bisacodyl(5 mg),Suppository [110294]
220Boro-Spirit Ear Drops-(0.183 gm Boric Acid in 2.08 ml of Alcohol 10 ml vial),Drop [202209052]
221Charcoal Activated (Powder)(100 gm box/pouch),Oral Powder [110051]
222Ciprofloxacin Eye Ointment 0.3% ( 3gm Tube) [4460001]
223Clofazimine(Tablet 50 mg 4),Tablet [202209022]
224Cloxacillin(500mg),Capsule [120092]
225Cloxacillin(Capsule 125 mg),Capsule [202209020]
226Codeine(Oral Solution 15 mg/5 ml 60 ml bottle),solution [202209080]
227Diethylcarbamazine(Oral Liquid 120 mg/5 ml 100 ml bottel),Liquid [202209023]
228Diloxanide Furoate(Tablet 500 mg),Tablet [202209024]
229Diphenylhydantoin(Tab 30 mg 10x10),Tablet [202209013]
230Dispersable Tablet Hydroxyurea (100 mg 10x10),Tablet [202209073]
231Finofibrate(Tablet 40 mg),Tablet [202209041]
232Fluphenazine 1 ml Amp(25 mg / ml),Injection [120354]
233Glycopyrolate(Inj 0.2 mg/ ml 1 ml vial),Injection [202209001]
234Gum Paint (Tannic Acid)(2% w/v 15 ml bottle),Bottle [202209046]
235Halothane BP 250ml [4000001]
236Hepatitis B Immunoglobulin(100 IU/Vial),Vial [110319]
237Human Chorionic Gonadotropin(Injection 10000 IU vial of 1 ml injection),Injection [202209062]
238Human Chorionic Gonadotropin(Injection 5000 IU vial of 2 ml injection),Injection [202209063]
239Hydroxyethyl(6% Saline solution for infusion)(Starch 6%IP 500 ml Bottel),Infusion [202209083]
240Imipramine(25 mg),Tablet [110360]
241Insulin soluble Inj. - 40 IU/ml [4350097]
242Ipratropium Bromide inhaler 20mcg per puff(200 metered dose container),Inhaler [1100376]
243Isoxsuprine(10mg),Tablet [120174]
244IV Human Immunoglobin 5% IV IG((5mg/100ml Each),Injection 100ml injection),Injection [202209067]
245Ketamine hydrochloride(10mg/ml (10ml vial)),Injection [110003]
246Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 10 mg (B) CR),Tablet [202209033]
247Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 25 mg (B) CR),Tablet [202209034]
248Levodopa (A) + Carbidopa (B)(Tablet 250 mg (A) + 25 mg (B)),Tablet [202209035]
249Levosalbutamol(50mcg/dose 30 capsule in 6 pack with 1 dispecing device),Capsule [202209070]
250Levosulbutamol(100 mcg 30 capsule in 6 pack with 1 dispecing device),Capsule [202209069]
251Lithium Carbonate(300 mg),Tablet [110358]
252Lorazepam2 mg / ml1 ml Vial [110369]
253Losartan(10 mg Tablet),Tablet [202209057]
254Medroxyprogesterone acetate(Injection 150 mg 1 ML / VIAL),Injection [202209064]
255Methyldopa Tab. - 250mg [4710040]
256Morphine(Injection 15 mg/ml 1 ml ampule),Injection [202209081]
257Noraderanaline Bitartrate(2 Mg Base/2ml (2ml Amp)),Injection [700472]
258Normal Saline(Nasal Drops: Sodium Chloride Drops 0.05% w/v 10 ml vial),Drop [202209053]
259Ormeloxifene(Tablet 30 mg 10x10),Tablet [202209065]
260Phenobarbitone(200 mg/ml),Injection [110060]
261Pilocarpine Eye drops 2%(5ml),Vial [110327]
262POMALIDOMIDE(Cap 2 mg),Capsule [202209031]
263Pralidoxime (PAM) Inj(25 mg/ml),Injection [4350085]
264Premix Insulin(30:70 Injection (Regular: NPH)2 vial of 100 ml),Injection [202209066]
265Promethazine(Injection 10 mg/ml 2ml vial),Injection [202209002]
266Protamine(Injection 50 mg/5 ml 5 ml vial),Injection [202209044]
267Pyridoxine Tab 10mg [4710380]
268Sodium Aminosalicylate Granules(10 gm Bottel of 100 gm),Powder [202209028]
269Sucralfate (20 mg Tablet 10 x 10),Tablet [202209058]
270Surfactant Suspension(Inj 25 mg/ml),Injection [202209077]
271Tab Mebeverine(Tab 200 mg 10 x 15),Tablet [202209056]
272Tamoxifen tab.(10 mg),Tablet [4710305]
273TOPOTECAN(Inj 4 mg 4 ml vial),Injection [202209032]
274Verapamil(Injection 5 mg/2 ml 2 ml vial),Injection [202209045]
275Alpha-Beta Arteether Inj 75 mg / 2 ml [700153]
276Ampicilline 125mg/30ml Syrup [987655]
277Antacid Chewable Tablet containing Aluminum hydroxide equivalent to dried gel 250mg+ Magnesium hydroxide 250mg+ Simethicone 50mg USP [4710419]
278Benzyl benzoate emulsion( emulsion),Emulsion [4220001]
279Calcium Syp 100ML Syrup (240mg/5 ml) [987642]
280Cefpodoxime200 mg + Ofloxacine 200mg Tab.(200+200),Tablet [120980]
281Cetrimide + Choline Salicylate Gel for oral ulcer 15ml Tube [4760001]
282Cetrimide Cream BP(0.1% w/w),Tube [4760003]
283Chloramphenicol 0.5%(5ml),Eye Drop [120073]
284Tab Ciprofloxacin 250 + Tinidazole 500 mg
285Tab Ciprofloxacin 500 + Tinidazole 600 mg
286Chlorhexidine 0.2% Mouth Gargle(100 ml),solution [4630028]
287Clobetasol 0.05% + Gentamicin 0.1% Cream 10 gm(10 gm tube),Cream [120082]
288Cyproheptadine HCL + Tricholine Citrate(2mg + 275 mg / 5 ml (100ml Bottle)),Syrup [120098]
289Dicyclomine Syrup [987647]
290Digestive Drop ( Digestive Enzyme And Multivitamin with L Lysine )( 15 ml),Drop [987868]
291Domperidone +Ranitidine 150mg Tab [987691]
292Doxylamine Succinate + Pyridoxine(10mg+10mg),Tablet [120117]
293Gentamicin Inj. - 40 Mg/Ml, 2ml AMP [987917]
294Insulin Human Mixtard inj. - 30:70( ),Injection Solution for [4350096]
295Ipratropium Bromide Powder for inhalation 250mcg/ml [4330004]
296Ketoconazole Tab [4710123]
297Lignocaine Hydrochloride Topical Solution USP(2%),Vial [4790014]
298Magnesium Sulphate Powder(400gm),Powder [20201043]
299Nepafenac ophthalmic(Suspension 0.1%),Eye Drop [140099]
300Nepafenac(1mg/ml),Eye Drop [120685]
301Nifedipine (Sublingual)(10 mg),Capsule [120548]
302Oseltamivir H1 N1 Antiviral syp 75 mg [700120]
303Paracetamol + Chlorphenaramine+ Phenylephrine(250 mg + 2.5 mg + 10 mg),Tablet [120560]
304Paracetamol + Phenylephrine + Chlorpheniramine Maleate (125mg+2.5 mg+1mg) /ml(15 ml Bottle with Dropper),Drop [120561]
305Paracetamol 100 mg/ml, 150 ml Drop(150 ml),Consumable [987903]
306Paracetamol 75 mg/ml(10 ml Inj),Injection [987904]
307paracetamol drop(100 mg/ml),Drop [4700041]
308Pentoprozole 40mg +Domperidone 10mg Tab [987675]
309Peptonised Iron 176.5 mg(Equivalent to 30 mg of Elemental Iron,Protein (as Peptone) 100 mg,Folic Acid 200 mcg, Vitamin B12 2.5 mcg 100ml),Bottle [20200910]
310Piroxicam(ointment),Ointment [10000]
311Prednisolone(10 mg/ml),Eye Drop [120259]
312Roxithromycin 150mg Tablet [987689]
313Sodium Chloride (Ophthalmic) 5%(10 ml),Eye Drop [120596]
314Sodium Hyaluronate (Intraocular)(10 mg /ml 2ml),Injection [120597]
315Syp. Cefodroxil 125mg/30mlSyrup [987657]
316syrup cefpodoxime(50 mg),Syrup [700426]
317Visco Gel for eye department
318BSS Solution For Opthalmic Use
319Lignocaine 4% heavy
320Tetanus Toxide inj 5ml( ),Injection Solution for [4350104]
321TetracyclineEye Ointment 1% 5 gm [120603]
322Flurbiprofen Sodium 0.03%(5 ml),Eye Drop [120492]

AI Tender Summary

OUR REF NO 47264729
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 30-01-2025
Authority
Authority Name Directorate Of Health Services
Work Description Tender For Supply Of Drugs/Surgical And Equipment, Medicine During The Year 2024-25- 1 Type c category equipments, furniture, implants and medicines 2 Autoclave Surgical drum SS-Size 15*12 approx 3 Autoclave Surgical drum SS-Size 9*9 approx 4 Autoclave Surgical drum SS-Size 11*9 approx 5 Autoclave Surgical drum SS-Size 11*5 approx 6 OT Trolly (Dressing) 7 Supra Pubic Trocar 12 No 8 Supra Pubic Trocar 8 No 9 Supra Pubic Trocar 14 No 10 Tooth Forcep & Non Tooth Forcep Midium Size 11 Suture Cutting (Micro) 12 Mayo Scissors (Carved) Midium 13 Nebular (Bone Cutter) 14 Sharp Scissors 9.0ml 15 Tissue Cutting Scissors Carved Midium 16 Mosquito artery big Size 17 Mosquito artery Medium artery 18 Gigli Saw vial 19 Bone Saw Big 20 Hegars Dilator set 21 Biopsy Gun 22 H.B Skin grafting handle 23 Bull dog 24 clamp 25 Suction Cannula disposable 26 O.T. Light double dome 27 Cautery Pin 28 Triway catheter No 20 29 Urinary Cathetor No 12, 30 Urinary Cathetor No 14 31 Urinary Cathetor No 10 32 K-90 Catheter 33 Tommy Syringe 34 Hperdomic Needle No 16 35 Hydrogen Peroxide (500ml) 36 Small Tooth 37 Non Tooth forcep 38 Bone Vax 39 Senetizer 40 Disposable Syrienge 2ml 41 Disposable Syrienge 5ml 42 Disposable Syrienge 10ml 43 Disposable Syrienge 20ml 44 Uro Bag 45 Adhesive Tape Roll 4 46 Paper Adhesive Roll PER Pack 47 Gloves No 6.5 48 Dressing Disposeble Gloves 49 Spinal Needle 50 Ven flow No 20 51 Suction Tube 52 Oxygen Key 53 Oxygen Flow Meter Set 54 Vicryl 3.0 Round body 55 Vicryl 2.0 ½ cr RB Needle 30mm 56 Vicryl 3.0 ½ cr RB Needle 22mm 57 Vicryl 3.0 ½ Cutting Needle 58 Vicryl 1 ½ cr RB Needle 36mm 59 Vicryl 1.0 ½ cr RB Needle 30mm 60 Ethilon 1. 0 ½ cutting Needle 36mm 61 Ethilon 2. 0 3/8cutting Needle 36mm 62 Ethilon 3. 0 3/8cutting Needle 36mm 63 Silk – 1.0 64 Silk – 2.0 65 Silk – 3.0 66 Hydrogen peroxide 6% 400ml 67 Butroclot solution 68 Drain sheet (Currugeted) 69 Sumag Ointment 70 Dis. Needle 16no, 71 K90 Katheter 72 3 way stop cock with extension line 73 Needle 24x1 ½ 74 Lignocain 4% vail 75 Endotrachial Tube 7.5cm 76 Endotrachial Tube 8.5cm 77 Poly Propylene 2.0 1/2 cr RB Needle 30mm 78 Surgical Cap 79 Chair S TYPE 80 Abdomans Spange 20 X20 81 Tailar Scisor 82 Feetal Doplar DIGITAL 83 Nebulization Machine 84 Giuco Meter 85 BP Instrument standmodal 86 BP Instrument Digital 87 Palse oximeter tabel Top 88 fogging Machine 89 Digital Tharma meter 90 Baby Tray 91 Autoclav drum 92 Gyser 20 LITER isi MARK 93 Wheel Chair 94 Digital Watch 95 O2 Flow Meter 96 Kideny Tray 8 97 Doctor Chair 98 Sizzer 8 99 Epigiotomy Sizzer 100 Hand Wash 500 ml 101 dispossable syrienge 50ml 102 dispossable syrienge 20ml 103 dispossable syrienge 10ml 104 dispossable syrienge 5ml 105 dispossable syrienge 3ml 106 dispossable syrienge 2ml 107 Follyes Cathetar 16 No 108 Endotrachial Tube 2cm 109 Endotrachial Tube 2.5cm 110 Endotrachial Tube 3cm 111 Endotrachial Tube 3.5cm 112 Endotrachial Tube 5cm 113 Endotrachial Tube 6cm 114 Endotrachial Tube 7cm 115 Endotrachial Tube 7.5cm 116 Endotrachial Tube 8.5cm 117 Endotrachial Tube 8cm 118 Air Pressure Line 119 O2 mask 120 NRBM Mask 121 Flatus Tube 122 Glucometer Strip 123 Albumin Strip 124 UTP Kit 125 Celispaid 126 Senitary Pad 127 Ambu Bag Adult 128 Ambu Bag pediatric 129 mettress 4 (6 x3) fom with cover 130 Baby Diper 131 Ventilator Tube 132 Pediatric dreep set 133 IV Stand SS 4 Wheel 134 Oxygen Key 135 Sterlizer Medium Size 136 Chair office 137 Steel Tray with Cover 138 Nebulization Mask 139 Refrigerator 180LIT 140 Strature with wheel 141 Lade Aprone 142 Nasalprobe Child 143 Nasalprobe Adult 144 Mayo sizzer 145 Fine tooth Forcep 146 tooth Forcep big 147 Step StoolMS 2 Step 148 Pattela Holding Forcep 149 Bone Cutter 150 Giggli Wire 151 T- Handel 152 Tubalring 153 Mucous Extractor 154 Caord clamp 155 Baby Tag 156 Romo Vac sizes of10, 12, and 14 FGbellow unit capacity is 800 ml.curved Needle Length is 175 cm. 157 Pules oximeter tabal Top 158 Weight Machine Adult 159 Enfusion Set 160 PPE Kit 161 Feeding Tube 5 no 162 Feeding Tube 6 no 163 Feeding Tube 7 no 164 Feeding Tube 8 no 165 P.M.O. Line 166 Adult Nosal Prong 167 Water Cooler 40 Litter 168 Urine polmale 169 Tuning fork (256) 170 Stop Watch 171 Percussion hammer 172 omce Table 173 Office Dustbin 174 LED Torch 175 Iron Almiraha 6 176 DigitalClock 177 FUJI PRINTER DRY IMAGING FILMOBX 10 DIGITAL X-RAY FILM 178 DISTAL REDIUS T,T OBLIQ PLATE (SIMPLE) 179 3.5 MMLOCKING CLEVICALPLATE ( 5 TO 8 HOLE ) 180 3.5/2.7 MMLOCKING CLEVICAL SUPERIALPLATE (5 TO 8 HOLE) 181 ADWANTEG SYRING 182 Illizarov Set 183 Modular Bipolar Set (1 Cese) 184 Blood Bank Refrigerator Technical specifications: Blood bank refrigerator1- Blood bank refrigerator – capacity 100 blood bags or more with two or more shelves.... 2- Inner chamber made of stainless steel, outer chamber made of powder coated steel sheet with high quality insulation material between the walls.3- Microprocessor based temperature controller with preset temperature 4 degreecentigrade plus minus 1 degree centigrade .and digital temperature display. 4- 50 htz 220-240 volts Ac power supply (single phase power supply in India). 5- Audio-visual alarm for low (less than 2 degree centigrade) and high (more than 8 degree centigrade) temperature.. 6- 7 day circular temperature chart recorder- in built.. 7- Air circulation fan. 8- Light bulb inside chamber. 9- Auto defrost mechanism or frost free, CFC free. 10- In built line voltage corrector 11- Vendor has to support the specifications with manufacturer’s brochure failing which offer may be rejected. Vendor has to demonstrate the equipment at BHEL General Hospital, Hyderabad within specified time limit, if asked for; failing which offer will be rejected. 185 Blood Celll Counter Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC3 histograms for WBC, RBC and PLTPrediluted mode ≤20μL | Whole blood mode ≤9µL , 60 samples per hour10.4 inch TFT Touch ScreenChinese, English, Spanish, Portuguese, Russian, French, Bahasa, IndonesiaUp to 400,000 results including numeric and graphical information LAN Port supports HL7 protocol | Support bi-directional LIS4 USB ports (for external printer, software upgrade, barcodereader, external WIFI, keyboard and mouse), LAN port (1)Thermal recorder, 50 mm wide paper, various printout formats External printer optionalTemperature: 15°C~35°C | Humidity: 10%~90%Air pressure: 70kPa~106kPa(100V-240V)±10% through online UPS (rating 1 KVA)≤180VA | (50Hz/60Hz)±1Hz ,410(L) x 300(W) x 400(H) mm ; 20Kg 186 DefibrillatorTECHNICAL SPECIFICATION OF DEFIBRILLATORDESCRIPTION of Function• Defibrillator is required for reviving the heart functions by providing selected quantum ofelectrical shocks with facility for monitoring vital parameters.Operational Requirements• Defibrillator should be Bi- Phasic, light weight and latest model• Should monitor vital parameters and display them• Should print the ECG on thermal recorders.• Should work on Manual and Automated external defibrillation (AED) mode. Manualselection up to 270 J.• Should be capable of doing synchronized & asynchronized cardioversion• Can be operated from mains as well as battery• Should have defibrillator testing facilityTechnical Specifications• Should be a Low Energy Biphasic defibrillator monitor with Recorder, having capability toarrest allarrhythmia within a maximum energy of 360 Joules• Should monitor ECG through paddles, pads and monitoring electrodes and Defibrillatethrough pads and paddles.• Should have Automatic Lead switching to see patient ECG through paddles or leads• Should measure and compensate for chest impedance for a range of 25 to 150 ohms• Should have a built in 50mm strip printer/ thermal recorder• Should have charging time of less than 3 seconds for maximum energy. Charging indicatorshould be there.• Should have bright electroluminescent display for viewing messages and ECG waveform of4 seconds• Should have external & internal paddles with paddles contact indicator – for good paddlecontact. Single Adult and pediatric paddles should be available.• Should have event summary facility for recording and printing at least 250 events and 50waveforms.• Should be capable of printing Reports on Event summary, configuration, self test, batterycapacity etc• Should have facility for self test/check before usage and set up function• Should have SP02 and NIBP integrated facility• Should have user friendly color coded operationEnvironmental factors• The unit shall be capable of operating continuously in ambient temperature of 10 -500 C andrelative humidity of 15-90%• The unit shall be capable of being stored continuously in ambient temperature of 0 -500Cand relative humidity of 15-90%• Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of Safety forElectromagnetic Compatibility.Power Supply• Power input to be 220-240VAC, 50Hz. Power cable should be fitted with Indian plug andadapter.• Resettable overcurrent breaker shall be fitted for protection• Should have a Rechargeable Battery capable of usage for at least 90minutes or 30discharges. 187 Electrolyte Analyzer Method Sample Speed :-Multi-Biosensor TechnoloTechnology 60-120µlISE ≥ 80 tests / hour Printer Inner Thermal Printer Expand FunctionAmbient Conditions PowerPower Requirement RS232 & COM Connector, Computer and Barcode reader available0-40°C, Relative humidity ≤ 85% AC 80V ∼ 260V, 50-60Hz, ≤ 80WEarth Voltage <5V, Online UPS (230V)with isolated, transformers - 0.5 KVAParameters K+ Detection Range (mmol/L) 0.50 ∼ 20.00 Precision (CV)≤1.0% Resolution (mmol/L)0.01MeasureScope & Precision Na+ 15.0∼200.0 ≤1.0% 0.1 Cl- 15.0∼200.0 ≤1.0% 0.1 Ca+ 0.10∼200.0 ≤1.0% 0.01 pH 4.00∼9.00 ≤1.0% 0.01 188 Elisa Reader WasherSpecifications for Microplate (ELISA) Reader1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD2. Should have linearity of ≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD; accuracy of ≤1.0%or 0.010 from 0.000–3.000 OD at 490 nm; precision of 1.0% or 0.005 OD from 0.0–2.0 OD;1.5% from 2.0–3.0 OD and resolution of 0.001 OD3. Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm includedfilters4. Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec5. Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths6. Should have onboard graphical thermal printer and USB2 interface with PC or Mac datastations for data output7. Should be able to store data for over sixty assay protocols8. System should come with a comprehensive software package allowing colorimetric andturbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix,normalization, and curve fit9. Software should have the functionality of flexible template creation for any microplate formatup to 1,536 wells10. Software should be either license free or license for minimum 5 systems should be providedSpecifications for Microplate washer Automatic washer compatible with strips and 96-well microplates that have flat-, U-, or Vbottom wells. Programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottomwashing, crosswise aspiration, and overflow washing. Dispensing speed control A plate shaking option to help minimize bubbles and adherence of liquid to well sides. Wash bottle sensor to detect high waste liquid levels Up to 75 programmable washing sequences Easily removable 8- or 12-way manifolds Easily accessible manifold interior for maintenance Removable and autoclavable plate carrier An aerosol protection cover Integrated vacuum and dispensing pumps to ensure accurate and quiet washing and toeliminate the need for external pumps. Residual well volume should be < 6 µl Wash bottle volume should be 2000 ml Soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes. Should come with 8-way manifold and 12-way manifold should be quoted in optional. On-board software should be capable of storing up to 110 wash protocols. Operating temperature 15-40 °C. Dimensions (WxDxH) not more than 35x43x20 cm Both instruments should be of from same manufacturer 189 Semi-Automatic Biochemistry AnalyzersTechnical Specifications Human Machine Interface Touch Panel / Key Board / MouseLinear Measurement Range 0.000 to 3.000 Absorbance Units (A)Photometric Accuracy ±2% or 0.007 whichever is higher, from 0 to 2.0A, ±3% from 2.0A to 3.0ADrift <0.003A/hr.Optical Measurement Silicon Diode Filters Type of filterWave LengthHalf Bandwidth Filter SelectionFlow cell TypeFlow cell volumeSipping Volume Sipping Mode Cuvette Volume : Interference: 340,405, 450, 505, 546, 578, 630+2 Optional: ±2nm: By Stepper motor: Stainless steel body & Quartz Window: 32 μι: 300 to 1000 μι: Automatic by specially designed Peristaltic Pump: 500 μι Temperature of Cuvete/flow cell Block Method Temperature Light Source Warm up Time Display Printer Memory CPUBuilt in Incubator : By Peltier effect: 25°C, 30° C and 37° C: 6V/10W Tungsten Halogen lamp: 90 Sec.: 7 TFT Display 300 x 930: Built in 55 mm, stationary head graphical thermal printer: DDR, & DRAN 1 GB, Flash 256 MB: ARN Cortex A8720 MHz: 2 Place for coagulation reagent | 15 Place for coagulation Cuvette 5 Place for test tubes Storage Capacity 2000 Open tests with 30 QC results/test (Normal and Abnormal controls)200000 Patient results with patient ID and GraphAnalysis Mode 1 point, 2 point (Sample blank) | Fixed time | Kinetic | CoagulationConcentration calculation : By factor or by standard Blanking PortPower WattageVoltage Operating Position : Water, Reagent: 4 USB, LAN Rj45: 100 Watts: 110-240 Volts ±10%, 50-60 Hz: On horizontal, flat, rigid and vibration free surface Operating Conditions Temperature Relative Humidity : from +18° C to 35° C: up to 85% Storage Condition Temperature Relative Humidity EnclosureSize (cm) Weight : from 10° C to + 60° C: up to 85%: ABS Fire retardant: 30X38X13.5 (LxBxH): 7.0 Kgs. (Approx) 190 Suction MachineSpecificationsPortable suction unit: size 38x17x28.5cm, weight 5.1kgDescription (e.g.: model Vario A/C, manufacturer Medela)Technical specifications: SUCTION MACHINE with pump:- Power supply: 230-240V/50Hz- Vacuum capacity: 18 litres/mim- Maximum depression: -75kPa (-563mmHg)Vacuum is created by a plastic piston and cylinder system, with four vacuum-creatingmodules (QuatroFlex™ technology).The membrane vacuum regulator permits accurate vacuum settings.Double overflow-protection system (bottle and pump).Working temperature range: +5 to +40°C. 191 Microscope Technical SpecificationsSl Name TechnicalSpecsquotedby bidderBiddersDeviationif any3.1 Body :Binocular, sturdy, stable base body with focus adjustment controls3.2 Eye piece :Paired, high quality, (the image of the object as seen throughthe binocular eyepiece should be well defined centrally in at least 2/3field of view), achromatic, widefield, 10x without inbuilt pointer. Theeyepiece should be aplatanic and have a minimum field number of 18.Diopter adjustment must be present on one/ both eye pieces or on theeye piece tube3.3 Objective :Three objectives10x,40x,100x,10x and 40x objectives should have numerical apertures of 0.25 and 0.65respectively and should be of spring loaded type or otherwise.100x should have numerical aperture of 1.25 and should be of oilimmersion and spring loaded type. Suitable prominent marking should beprovided on 100x for easy identification.Unbreakable containers to be provided for storing the objectives. Allobjectives should be wide field, achromatic and parfocal.Making for the Objectives :Each objective should be engraved with thefollowing informations:-• Name of the manufacturer• Magnification and numerical aperture, for example, 10x/0.25• 100x objective should be engraved with the word ‘Oil’in changing from one objective to another or reintroducing the sameobjective by rotation of the nosepiece, the object at the center of thefield should not appear displaced by more than 0.02 mm in the objectplane in any direction.3.4 Nose piece:Revolving nose piece to accommodate a minimum of threeobjectives with click stops. It should be provided with ribbed grip for easyrotation mounted on a precision ball bearing mechanism for smooth andaccurate alignment. Extra ports if any should be fitted with dust proofmetallic/ebonite caps.3.5 Stage Uniformly horizontal, mechanical stage having dimensions oflength 140 mm (+/- 20mm) with fine vermier graduations (minimumreading accuracy of 0.1 mm). the stage should be provided with springloaded slide holder for exact positioning of specimen/ slide. It should bedesigned with convenient sub-stage vertical coaxial adjustment for slidemanipulation. The stage should have ball-bearing arrangement to allowsmooth travel in transverse directions i.e. 80 mm (+/-5mm) and front toback direction, 50mm (+/-5mm)3.6 Sub-stage condenser:Abbe-type condenser, numerical aparature (N.A.)1.25 focusable with rack and pinion arrangement incorporating anaspherical leps and an iris-diaphragm. The condenser should have a filterholder and removable/ swing in/ out blue filter (suitable for bright fieldMicroscopy).3.7 Sub-stage illuminator: 1.The system should have a build-in variable lightsource (Illuminator). This light source should have a 20 W, 6 V Halogenlamp. The circuitry for the light source should include a constant voltagesupply. The system should be provided with a step down transformer andan on-off switch and intensity control. The lamp should be provided witha lamp socket which has the facility for easy replacement of the bulb,2. Power Supplya. Voltage 220 V, 50 Hz ACb. Should have one on-off power switch, 3 core power cord with a 3 pointmale plug.3. The system should have an inbuilt protective/ safety device towithstand fluctuations of voltage from 140 V to 280 V4. A plano-concave mirror in fork mounting should be supplied whichwould be attachable to the base for field use. (where power is notavailable).5. The fuse for the halogen lamp should be easily accessible to theoperator6. The Illuminator should have a build-in field diaphragm for Kohlerillumination3.8 Eye piece tubes:Binocular eye piece tubes, inclined at 45 degrees,rotatable through an angle of 360 degrees, having inter-pupullarydistance range of 54-74 mm or wider, covering the above mentionedrange3.9 Focusing knob:Co-axial coarse and fine focusing knobs capable of smoothfine focusing movement over the full range of coarse travel. The finefocusing movement should have sensitivity of two microns or less (finer)over the entire coarse focusing stop safety arrangement should beprovided.3.10 General 1.All optical parts including objectives, eye pieces and prismsshould have anti-reflective coating which also gives anti-fungal property.2.All metallic parts should be corrosion-proof, acid-proof and stain-proof3.Working manual should be provided with each microscope4.A bottle of at least 25 ml immersion oil, a roll of lens tissue paper andlens cleaning solution (100 ml) should be provided with each microscope.5.One no.of anti static cleaning brush should be provided with eachMicroscope for cleaning purpose.6.Each Microscope should be supplied with Blue filters. The Blue filtershould be packed in the ox and not fixed on the Microscopes. 4 System Configuration Accessories, spares and consumablesSl Name TechnicalSpecsBiddersDeviationquotedby bidderif any4.1 System as specified-4.2 Each microscope should be supplied with spare parts as under:•100x oil immersion objective (as per the specifications given under B3) –one.•Halogen bulb, (6volts, 20w) – 6 Nos.•Fuses – 6 Nos.4.3 All consumables required for installation and standardization of system tobe given free of cost. 192 Truenat Machine 3. Equipment and site preparationAn essential step of the implementation process is the selection of instruments to fit theneeds of the testing algorithm, anticipated workload and intended setting of use theTruenat TB tests. Laboratories should select the appropriate number and models ofTruelab micro PCR Analyzers to match anticipated demand (see Table 4 for estimationof throughput). Note that the ability of a testing site to utilize all of the capacity ofa workstation may not be an important factor for selecting Truenat TB testing sites, especially considering that the Truenat TB test isdesigned to be placed at peripheral microscopycenters.All instruments must be documented to be “fit forpurpose” through testing with known positive and/or negative material prior to commencing testingof clinical specimens.Planning for service and maintenanceTruelab and Trueprep instruments require minimalpreventive maintenance as per the manufacturer.For an example of a preventive maintenance logthat shows routine daily and monthly activitiesas well as ad hoc activities to be conducted asnecessary, see Annex 4.The manufacturer offers warranty packages forequipment service and maintenance includingthrough its growing network of in-country serviceproviders. Annual warranties that providecomprehensive service and maintenance includingon-site visits are available through the Stop TBPartnerships Global Drug Facility (GDF); seethe GDF Diagnostics Catalog for more details.Countries planning to implement Truenat shouldinform the manufacturer in advance to allow themanufacturer to plan as needed for expansion ofits network of service providers.Site preparation and assessment of readinessAs part of the situational analysis, each of theselected testing sites will have been evaluatedfor suitability for conducting Truenat TB testingusing a standardized checklist (see Annex 6). Keyinfrastructure and operational considerations forsite preparation include:• Power: In-built batteries in both devices allow fortesting without power for up to 8 hours; deviceswill not allow for a cycle to start if battery poweris too low. Batteries are expected to last fiveyears. Note that power is still required to chargebatteries: recharging time is approximately 4hours for the micro PCR analyzers, 9 to 10 hoursfor the Trueprep device and 4 to 6 hours for themicro printer. Use of instruments while chargingis possible, when the electrical socket is wellgrounded. The devices are able to operatewithin the 100-240 voltage range; no additionalvoltage stabilization is required in settings withinstabilities or low voltage. Solar panels maybe a solution for settings without any access topower (see Box on specifications). Power mayalso be required to possibly cool the storageroom for test chips; as described below, chipsshould be stored at ≤30°C.Activities at a glance□ Select, procure, install and set-upequipment□ Verify the instruments are fit for purpose□ Arrange for preventive maintenanceand servicing□ Prepare site infrastructure for Truenatinstruments and testing□ Ensure a safe and functional testingsiteSuggested specifications of a solar panelas per the manufacturer:• Panel: 150 Watts. Dimensions (LxWxH):1490 x 665 x 35 mm• Battery: 12V 18Ah Lead Acid• Solar Charge Controller + DC to DCboost converter (12V to 170V, 100 Watts)Controller and converter available fromMolbio; panel, battery and installation tobe locally sourced. 193 Ice Lined RefrigeratorILR can maintain a temperature from +2°C to +8°C with as little as 8 hours of power supply in 24 hours 194 Audiometer Air conduction Audiometry (125-8000Hz) Bone conduction Audiometry 195 Bio Chemistry AnalyzerGeneral Information Machine TypeTest Speed Test Principle Test Method Calibration Type : Random access: Constant 200 tests/hour (Mono Reagent or Double Reagent): Colorimetric method, turbidimetry, Immuno turbidimetry: 1 Point End, 2 Point End, Fixed Time and Kinetics: Linear and Non Linear 1 Point Linear, 2 Point Linear, ExponentialLogi - 10g, 3P, 4P, Multi-point Linear, Spline, Line Graph Sample UnitReagent UnitReaction Unit Sample Tray Sample TubeSample Volume Sample ProbeSample Barcode Reagent TrayReagent VolumeReaction Tray Reaction Volume : 40 Sample Positions: Micro Cup & Test Tube & Blood Collection Tube (Ф 12 - 13) mm * (25 - 100) mm: 2 - 30µL, Step by 0.1 µL: Liquid surface detection, timely tracking for liquid volume Collision Protection: Sample barcode reader (Option): 40 Reagent Positions (40 for R1 or 40 for R2) 24 hours cooling system with paltier pad inside: 20 – 300 µL, Step by 1 µL: 44 reaction new pyrex cuvettes, perfect transmittance: 150µL - 330µL Mixing system Mixer : Paddle-type mixing, effective and reducing carryover Optical SystemOperating system Light Source Wave LengthAbsorbance Range ResolutionOperating System Report Printing Interface : Halogen Lamp: 340nm; 405nm; 450 nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options): 0 – 4.0 Abs: 0.0001 Abs: Windows XP, Windows 7, Windows 8, Windows 10: 6 Formats Optional, Support Custom Formats: Pattern, TCP/IP network Interface Working Conditions Power Supply : AC 110/220V ± 10%, 50/60 Hz, 1000VAWater consumption : 8L/hour (maximum) Dimension Weight : 750mm * 550nm * 490mm (L*W*H): 70 kgs Power Supply 110/220V ± 10%, 50/60 Hz, 1000VA,Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA 196 Blood Donor Couch Comfortable chair type with soft padding for cushioning and rexin cover.Seat, back rest and leg rest size designed for donor comfort.It should have step less electric remote controlled height adjustment approximately 58 – 60 cm.Adjustable arm rest for donor’s comfort and phlebotomist friendlyEasily tilted to head low position, electrically operatedComfortable working level for the operator. Lifting capacity - Approx 200 kg.4 Lockable castors for easy mobilityStorage Drawers for storing consummables & Blood Collection MonitorsUP/DOWN controlOPTIONS: 1.A paper roll holder can be fixed on the upper part of the chair. 2.Melodious musical Headphone can be integrated for patient relaxation while blood donation is in progress 197 BP Apparatus Digital 198 Cautery Machine SPECIFICATIONS FOR CAUTERY MACHINE(HIGH-END SURGICAL ELECTROCAUTERY WITH VESSEL SEALER)High-End Electro Surgical Unit with Vessel Sealer Unit should be comprised of:1. An integrated RF Electro Surgical Unit (For electrosurgical Cut & Coagulation modes for the optimum effectof HF surgery)2. Vessel Sealer (For sealing vessels & tissue structures, during open and laparoscopic surgeries).A) Electro Surgical Unit should be microprocessor controlled, US-FDA &/ European Certificate marked inaccordance with the medical devices directive (93/42/EEC) 4 Digit notified & Electro Surgical Unit shouldcomply with the requirement of the medical devices directive of class 1 equipment and electromagneticcompatibility.B) Electro Surgical Unit quoted should have a very strong Installation base- must be provided a minimum of 50installation base in India.C) Special bipolar mode for coagulation of vascular tissue (Vessel Sealing) up to 7 mm with Reusable/Disposable Hand Instrument for open as well laparoscopic surgeries & should have 510 K approval for 7 mmVessel.D) The system should have Monopolar Cut & Coagulation Mode, two Bipolar Modes with auto bipolar start &stop and Vessel fusion technology all integrated in one system. Should have around 8 Cutting Modes &around 8 Coagulation Modes.E) The equipment should be micro controller based & should adjust the power to get the desired surgical effecton the tissue. All settings should be controlled by the machine and according to the tissue deliver. Powershould be display on the screen with graph facility to show the deliver poweF) Should have Power and Voltage automatic regulation feature to prevent tissue damage and charring. Theoutput voltage should be regulated at various levels.G) The System should have LCD/ LED Backlight adjustment for good visibility in operating room, patient platemonitoring facility, audio-visual alarm, and deactivate output if contact between patient and patient plate isnot proper to eliminate the risk of patient burns.H) Should have optional facility of connecting reusable contact quality Monitoring Return Electrode Pediatric /Adult with 100% washable foot switches (for terminal cleaning & disinfection)- Monopolar & BiopolarI) The high End Electro Surgical Cautery Unit with Vessel fusion technology should be compatible with theintegration system of OR mainly O.E.M.’s like – Karl Storz, Olympus & De Vincy.J) The high-End Electro Surgical Cautery Unit with Vessel fusion technology should be supplied along withessential accessories from the same original equipment manufacturer, affidavit for the same has to besubmitted by the bidder, else bid will be rejected.1. Open and Laparoscopic Surgery Vessel seal instrument with cord. Reusable (which has certificate for theminimum shelf life of 50 applications and should be autoclavable- 01 each (Open & Lap) and ifDisposable 50 each (Open & Lap).2. Diathermy Pad/ Patients plate- adult/ pediatrics with patient plate cable if Reusable- 01 with a shelf lifeof minimum 50 applications and if disposable 50 pcs3. Monopolar two pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) withminimum shelf-life of 1000 applications or 24 months from date of supply-1no.4. Bipolar one pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) with minimumshelf-life of 1000 applications or 24 months from date of supply-1no.5. Monopolar electrosurgical pencil with different electrodes either Reusable 01 Unit with reusable 05electrodes of various shapes with a shelf life of minimum 50 applications or Disposable- 50 Units6. Nonstick Bipolar forceps Straight & bayonet each with bipolar cord for forcep either Resuable 01 Unitwith a shelf life of minimum 50 applications or Disposable- 50 Units7. Reusable universal adaptor for attaching several Laparoscopic hand instruments with a shelf life of aminimum of 50 applications-1no.8. Cart with Castors with unconditional replacement if break within 05 years from the date. 199 Centrifuge 12 Tube 200 DVT Pump Deep Vein Thrombosis (DVT PUMP)• Size: 6.5” L x 7.0” W x 12.8” H• Weight: 2.5kg• Pressure Settings:• Calf/Thigh sleeve: 30, 40 (default), 50, 60 mmHg ; +10/-5mmHg Foot sleeve: 120 mmHg ; +10/-5mmHg• Input Rating: AC 100V-240V 50/60 Hz, 0.2A-0.55A• Fuse Rating: 1A, 250V• Appliance Class: Class I, Type BF• Not AP or AGP type• Classification to FDA: Class II• Classification to CDSCO: Class B• Humidity: Operation 30% to 75 %• Storage & Transportation 30% to 75%• Air pressure: 4 – 16 kPA• Temperature: Operation 15° - 35° C• Storage & Transportation 5-60 degree C• Cycle Time: Inflation 12 seconds +/- 10%• Deflation: 48 seconds +/- 10% 201 Prolene Suture Size 2-0 202 Prolene Suture Size 1-0 203 Prolene Suture Size 3-0 204 Nylone Suture 2-0 205 Disposable Hemorrhoidal Circular Stapler 32mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 206 Disposable Hemorrhoidal Circular Stapler 34mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 207 Silk suture, USP 3-0, 70 cm, needle: 26*1*2 mm, reverse cutting, 3/8 circle. 208 Ethicon Ethilon Sutures USP 4-0, 3/8 Circle Reverse Cutting - NW3326 209 Nylone Suture 3.0 210 Botroclot Solution 211 Disp.LinearCutter 60 212 Disp.LinearCutter 80 213 Disp.LinearCutter 100 214 Disposable Curved Circular Stapler 29mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 215 Disposable Curved Circular Stapler 31mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 216 Acetylsalicylic Acid (Aspirin)*(Tablet 25 mg),Tablet [202209005] 217 Allopurinol(100mg),Tablet [110034] 218 Artemether + Lumefantrine(20mg+120mg),Tablet [110149] 219 Bisacodyl(5 mg),Suppository [110294] 220 Boro-Spirit Ear Drops-(0.183 gm Boric Acid in 2.08 ml of Alcohol 10 ml vial),Drop [202209052] 221 Charcoal Activated (Powder)(100 gm box/pouch),Oral Powder [110051] 222 Ciprofloxacin Eye Ointment 0.3% ( 3gm Tube) [4460001] 223 Clofazimine(Tablet 50 mg 4),Tablet [202209022] 224 Cloxacillin(500mg),Capsule [120092] 225 Cloxacillin(Capsule 125 mg),Capsule [202209020] 226 Codeine(Oral Solution 15 mg/5 ml 60 ml bottle),solution [202209080] 227 Diethylcarbamazine(Oral Liquid 120 mg/5 ml 100 ml bottel),Liquid [202209023] 228 Diloxanide Furoate(Tablet 500 mg),Tablet [202209024] 229 Diphenylhydantoin(Tab 30 mg 10x10),Tablet [202209013] 230 Dispersable Tablet Hydroxyurea (100 mg 10x10),Tablet [202209073] 231 Finofibrate(Tablet 40 mg),Tablet [202209041] 232 Fluphenazine 1 ml Amp(25 mg / ml),Injection [120354] 233 Glycopyrolate(Inj 0.2 mg/ ml 1 ml vial),Injection [202209001] 234 Gum Paint (Tannic Acid)(2% w/v 15 ml bottle),Bottle [202209046] 235 Halothane BP 250ml [4000001] 236 Hepatitis B Immunoglobulin(100 IU/Vial),Vial [110319] 237 Human Chorionic Gonadotropin(Injection 10000 IU vial of 1 ml injection),Injection [202209062] 238 Human Chorionic Gonadotropin(Injection 5000 IU vial of 2 ml injection),Injection [202209063] 239 Hydroxyethyl(6% Saline solution for infusion)(Starch 6%IP 500 ml Bottel),Infusion [202209083] 240 Imipramine(25 mg),Tablet [110360] 241 Insulin soluble Inj. - 40 IU/ml [4350097] 242 Ipratropium Bromide inhaler 20mcg per puff(200 metered dose container),Inhaler [1100376] 243 Isoxsuprine(10mg),Tablet [120174] 244 IV Human Immunoglobin 5% IV IG((5mg/100ml Each),Injection 100ml injection),Injection [202209067] 245 Ketamine hydrochloride(10mg/ml (10ml vial)),Injection [110003] 246 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 10 mg (B) CR),Tablet [202209033] 247 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 25 mg (B) CR),Tablet [202209034] 248 Levodopa (A) + Carbidopa (B)(Tablet 250 mg (A) + 25 mg (B)),Tablet [202209035] 249 Levosalbutamol(50mcg/dose 30 capsule in 6 pack with 1 dispecing device),Capsule [202209070] 250 Levosulbutamol(100 mcg 30 capsule in 6 pack with 1 dispecing device),Capsule [202209069] 251 Lithium Carbonate(300 mg),Tablet [110358] 252 Lorazepam2 mg / ml1 ml Vial [110369] 253 Losartan(10 mg Tablet),Tablet [202209057] 254 Medroxyprogesterone acetate(Injection 150 mg 1 ML / VIAL),Injection [202209064] 255 Methyldopa Tab. - 250mg [4710040] 256 Morphine(Injection 15 mg/ml 1 ml ampule),Injection [202209081] 257 Noraderanaline Bitartrate(2 Mg Base/2ml (2ml Amp)),Injection [700472] 258 Normal Saline(Nasal Drops: Sodium Chloride Drops 0.05% w/v 10 ml vial),Drop [202209053] 259 Ormeloxifene(Tablet 30 mg 10x10),Tablet [202209065] 260 Phenobarbitone(200 mg/ml),Injection [110060] 261 Pilocarpine Eye drops 2%(5ml),Vial [110327] 262 POMALIDOMIDE(Cap 2 mg),Capsule [202209031] 263 Pralidoxime (PAM) Inj(25 mg/ml),Injection [4350085] 264 Premix Insulin(30:70 Injection (Regular: NPH)2 vial of 100 ml),Injection [202209066] 265 Promethazine(Injection 10 mg/ml 2ml vial),Injection [202209002] 266 Protamine(Injection 50 mg/5 ml 5 ml vial),Injection [202209044] 267 Pyridoxine Tab 10mg [4710380] 268 Sodium Aminosalicylate Granules(10 gm Bottel of 100 gm),Powder [202209028] 269 Sucralfate (20 mg Tablet 10 x 10),Tablet [202209058] 270 Surfactant Suspension(Inj 25 mg/ml),Injection [202209077] 271 Tab Mebeverine(Tab 200 mg 10 x 15),Tablet [202209056] 272 Tamoxifen tab.(10 mg),Tablet [4710305] 273 TOPOTECAN(Inj 4 mg 4 ml vial),Injection [202209032] 274 Verapamil(Injection 5 mg/2 ml 2 ml vial),Injection [202209045] 275 Alpha-Beta Arteether Inj 75 mg / 2 ml [700153] 276 Ampicilline 125mg/30ml Syrup [987655] 277 Antacid Chewable Tablet containing Aluminum hydroxide equivalent to dried gel 250mg+ Magnesium hydroxide 250mg+ Simethicone 50mg USP [4710419] 278 Benzyl benzoate emulsion( emulsion),Emulsion [4220001] 279 Calcium Syp 100ML Syrup (240mg/5 ml) [987642] 280 Cefpodoxime200 mg + Ofloxacine 200mg Tab.(200+200),Tablet [120980] 281 Cetrimide + Choline Salicylate Gel for oral ulcer 15ml Tube [4760001] 282 Cetrimide Cream BP(0.1% w/w),Tube [4760003] 283 Chloramphenicol 0.5%(5ml),Eye Drop [120073] 284 Tab Ciprofloxacin 250 + Tinidazole 500 mg 285 Tab Ciprofloxacin 500 + Tinidazole 600 mg 286 Chlorhexidine 0.2% Mouth Gargle(100 ml),solution [4630028] 287 Clobetasol 0.05% + Gentamicin 0.1% Cream 10 gm(10 gm tube),Cream [120082] 288 Cyproheptadine HCL + Tricholine Citrate(2mg + 275 mg / 5 ml (100ml Bottle)),Syrup [120098] 289 Dicyclomine Syrup [987647] 290 Digestive Drop ( Digestive Enzyme And Multivitamin with L Lysine )( 15 ml),Drop [987868] 291 Domperidone +Ranitidine 150mg Tab [987691] 292 Doxylamine Succinate + Pyridoxine(10mg+10mg),Tablet [120117] 293 Gentamicin Inj. - 40 Mg/Ml, 2ml AMP [987917] 294 Insulin Human Mixtard inj. - 30:70( ),Injection Solution for [4350096] 295 Ipratropium Bromide Powder for inhalation 250mcg/ml [4330004] 296 Ketoconazole Tab [4710123] 297 Lignocaine Hydrochloride Topical Solution USP(2%),Vial [4790014] 298 Magnesium Sulphate Powder(400gm),Powder [20201043] 299 Nepafenac ophthalmic(Suspension 0.1%),Eye Drop [140099] 300 Nepafenac(1mg/ml),Eye Drop [120685] 301 Nifedipine (Sublingual)(10 mg),Capsule [120548] 302 Oseltamivir H1 N1 Antiviral syp 75 mg [700120] 303 Paracetamol + Chlorphenaramine+ Phenylephrine(250 mg + 2.5 mg + 10 mg),Tablet [120560] 304 Paracetamol + Phenylephrine + Chlorpheniramine Maleate (125mg+2.5 mg+1mg) /ml(15 ml Bottle with Dropper),Drop [120561] 305 Paracetamol 100 mg/ml, 150 ml Drop(150 ml),Consumable [987903] 306 Paracetamol 75 mg/ml(10 ml Inj),Injection [987904] 307 paracetamol drop(100 mg/ml),Drop [4700041] 308 Pentoprozole 40mg +Domperidone 10mg Tab [987675] 309 Peptonised Iron 176.5 mg(Equivalent to 30 mg of Elemental Iron,Protein (as Peptone) 100 mg,Folic Acid 200 mcg, Vitamin B12 2.5 mcg 100ml),Bottle [20200910] 310 Piroxicam(ointment),Ointment [10000] 311 Prednisolone(10 mg/ml),Eye Drop [120259] 312 Roxithromycin 150mg Tablet [987689] 313 Sodium Chloride (Ophthalmic) 5%(10 ml),Eye Drop [120596] 314 Sodium Hyaluronate (Intraocular)(10 mg /ml 2ml),Injection [120597] 315 Syp. Cefodroxil 125mg/30mlSyrup [987657] 316 syrup cefpodoxime(50 mg),Syrup [700426] 317 Visco Gel for eye department 318 BSS Solution For Opthalmic Use 319 Lignocaine 4% heavy 320 Tetanus Toxide inj 5ml( ),Injection Solution for [4350104] 321 TetracyclineEye Ointment 1% 5 gm [120603] 322 Flurbiprofen Sodium 0.03%(5 ml),Eye Drop [120492]
Basic Detail
Tender No 332/2025
Bidding Type Tender
Location
City barwani
State Madhya Pradesh
Key Dates
Publish Date 17 Jan 2025
Submission Date 30 Jan 2025
Open Date 31 Jan 2025
Finance
Tender Value 22 Lakhs
Tender Fee 1000
EMD 50000
Exemption Not Available
Document List
0b73e13f-6f71-43f6-946f-8fcb07f6e887.html
BOQ_466848.xls
NIT.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 17, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 30, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 31, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0b73e13f-6f71-43f6-946f-8fcb07f6e887.html

xls

BOQ_466848.xls

pdf

NIT.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender