| 1 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes scaffolding, tools and plants as necessary and taking out them andlowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. (a) For depth upto 150 metre for40mm dia tubewell with top enlargement 80mm dia. (i) 40 mm dia. boring etc. |
| 2 | Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes scaffolding, tools and plants as necessary and taking out them andlowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. (a) For depth upto 150 metre for40mm dia tubewell with top enlargement 80mm dia. (ii) 80 mm dia. boring etc. |
| 3 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(i) 40 mm |
| 4 | Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(ii) 80 mm |
| 5 | Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.(i) 40 mm dia. |
| 6 | Supplying, fitting and fixing steel cutter piece upto 450 mm long withsockets.(i) 40 mm dia. |
| 7 | Supplying, fitting & fixingand installation of 1.0 HP Sub-Mersible pump with motor of 80 mm dia of approved make and brand(CG/KSB / Kirloker) with panel box cable and necessary fittings. (Non Schedule Item) |
| 8 | Supplying fitting fixing PVC insulated flexible three core flat cables of area 2.5 sqmm as per standard and bunched Type A of IS 5831/1984 & Sheathing to IS 8130/1984 for higher flexibility are used to connect underwater as per ST I type os IS 5831/1984. (Non Schedule Item) |
| 9 | Supplying, fitting and fixing Single Phase VOLTAGE SENSING PREVENTER & AUTO START UNIT Submersible Pump control panel (1/2 HP to 2 HP range) of L & T brand of an influential electronic circuit which keeps three stage. |
| 10 | Supplying, fitting & fixingG.I cap at Top. (i) 80 mm dia. |
| 11 | Supplying, fitting and fixing of Reducing Socket...(i) 80mm X 40mm |
| 12 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. |
| 13 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(d) 1000 litre capacity |
| 14 | Supplying, fitting & fixinggunmetal wheel valve of approved brand and make.(a) 25 mm dia. |
| 15 | Supplying, fitting & fixinggunmetal wheel valve of approved brand and make.(a) 20 mm dia. |
| 16 | Supplying, fitting and fixing bib cock or stop cock.(g) Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.(i) 15 mm |
| 17 | Earth work in excavation of foundation trenches or drains, in all sorts of soil… |
| 18 | Single brick flat solling for pillar foundation,plinth & platform. |
| 19 | Cement concrete with graded stone ballast (40 mm size excluding shuttering (a) 1:3:6 proportion. |
| 20 | Filling in foundation trenches or plinth by Silver Sand, in layers not exceeding 150 mm. |
| 21 | Brick work with 1st class bricks in cement mortar (1:6) in Foundation and Plinth. |
| 22 | 125 mm thick Brick work with 1st class bricks in cement mortar (1:4) in Ground Floor. |
| 23 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(iii) RajMahal. |
| 24 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m.(i) Tor steel/Mild Steel . II. Other than SAIL/ TATA/RINL. |
| 25 | Hire and labour charges for shuttering with centering and necessary staging…(B) 25 mm to 30 mm Shuttering as per direction of EIC… |
| 26 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]...(a) With 1:4 cement mortar...(c) 10 mm thick plaster |
| 27 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]...(a) With 1:6 cement mortar...(c) 15 mm thick plaster |
| 28 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work…With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m. (i) Coloured decorative |
| 29 | Decorative cement based paint in two coats on new surface… |
| 30 | Display Board(Marble 450mmx300mm) |