Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-02-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-02-2025 |
| Sl. No. | Item Description |
| 1 | Comprehensive Maintenance of the following Central/ Package/ VRF AC Plants installed at NAD(V),MO(V), BV YARD, INS VISWAKARMA & CQAE Areas, Complete including Cooling Tower, AHUs, Electrical Control Panels, Pumps, Pipelines, Outdoor & Indoor Units, Copper Tubes, Drain Line, Ducts, Electric Connections etc, and connected equipment of complete AC system including attending to breakdown and carrying out Repairs / Overhauling / Leak Testing/ Servicing and Replacement of defective parts to ensure smooth functioning of AC Plants to the entire satisfaction of Garrison Engineer complete all as specified and as directed by the Engineer-in-Charge. (i) Comprehensive maintenance of Water cooled Central AC Plants of following capacity.(a) P-7 AC Plant of capacity (3×25 TR) (NAD)(b) TRS-II AC Plant of capacity(3×110 TR) (NAD)(c) P-195 AC Plant of capacity (3×80 TR) (NAD)(d) 555(New Mine Workshop)AC Plant of capacity (3×90 TR) (NAD)(e) K-Ster(NAD) AC Plant of capacity (3×52 TR)(f) Tanker Store (MOV) AC Plant of capacity (3×25.4 TR)(g) Store House (MOV) AC Plant of capacity (3×90 TR)(h) Shivalik Store House (3x50 TR) (MOV) AC Plant |
| 2 | (ii) Comprehensive maintenance of Air cooled Package Central typePlants of following capacity.(a) CNAI AC of capacity (3×8.5 TR)(b) CQAE AC plant of capacity (2x7.5 TR) (c) Para-11 of capacity(2×5TR) (NAD)(d) P-16 Magazine of capacity(3×5 TR) (NAD)(e) P-3 Bldg AC plant of capacity (2x5.5 TR) (NAD)(f) P-555(Mine workshop) of capacity(3×5.5 TR) (NAD)(g) P-52 D AC plant of capacity (2x8.5 TR) (NAD)(h) P-171 Old of capacity(3×11 TR) (NAD)(i) P-144 of capacity(3×15 TR) (NAD)(j) P-121 LT Mag AC plant of capacity (2x15 TR) (NAD)(k) P-171 New of capacity(3×45 TR)(l)B Shed AC plant of capacity (3x40 TR) (NAD)(m)Viswakarma Adm Bldg AC plant of capacity (4x5.5 TR) (n) Cold and Cool Room(BV Yard) AC Plant of capacity (20000 Btu)(o) Cold and Cool Room(BV Yard) AC Plant of capacity (10000 Btu)(p) P-172 at NAD (3x5TR)(s) P-53 VA at NAD (3x15 TR) |
| 3 | Note for Serial Item No. 1: The quoted rate shall be deemed to include the following provisions:[a]MINIMUM MANPOWER TO BE EMPLOYED: The contractor shall be required to employ the One Electrician [2 Years Certificate holders from recognised ITI / NCT / VT in the relevant trade with 3 Years of relevant experience] and One Refrigeration Mechanic [2 Years Certificate holders from recognised ITI / NCT / VT in the relevant trade with 3 Years of relevant experience] per Shift of 08 Hours from 0900 Hours to 1700 Hours and these Tradesmen shall report to Office of AGE [E/M] for day to day maintenance and efficient functioning of AC Plants. [b] Preventive / Periodical Maintenance and Annual Comprehensive Maintenance to all AC Plants comprising of Chiller Unit i.e. Descaling of Condenser, Chiller etc. complete AHUs with Electric Motor including Pan type Humidifiers’ of different KW ratings, complete Ducting, Fan Coil Units, Cooling Tower Complete, Hot Water Generator and its Piping Network, Chilled Water Piping, Condensate Piping, Pump and Motor of Chilling Water and Condenser of Cooling Towers, Water Supply Piping, Instrument Starter, Connected Control Cabling / Wiring including Electric Panel and Switchgear all as specified. The job also includes servicing and cleaning of filters of cassette type indoor units, split units with water jet pump and removing scale/ dirt from indoor/outdoor units etc as and when required and as directed by Engineer-in-Charge. The contractor shall submit the record of Periodical / Preventive / Annual Maintenance Services carried out along with documentary evidence before claiming payment. |
| 4 | [c]Supply and fixing ofMinor Spares viz. Mechanical / Electrical / Electronics etc.(except Spares catered vide in Schedule \"A\" BoQ ) as and when required for trouble free and smooth operation of AC Plantsincluding overhauling as and when required to all mechanical parts of AC Plants,repair / maintenance of Cooling Towers, AHU, Condensing Units etc. complete all as directed by the Engineer-in-Charge. All the safety measures shall be ensured for serviceable condition round the clock and cost of their spares and consumables etc. shall deemed to be included in the rate quoted. Nothing extra shall be paid extra on these accounts. [d]Spares required for maintenance of AC Plants other than those catered vide Serial Item No. 2 to 110 of this Schedule / BoQ, Consumables such as Grease, Lubricants, Cotton Waste and other connected consumables etc. required for daily operation and routine maintenance.[e] Spare Parts catered vide Serial Item No. 2 to 81 of this Schedule/ BoQ as supply only shall be supplied in advance and kept under the custody of the Engineer-in-Charge and shall be issued to the contractor whenever the requirement arises. No AC Plant shall be kept non operational due to non availability of spares. [f] Any defective components and / or any other materials which is not specified / given in Schedule \"A\", but essential for trouble free and smooth operation of AC Plants. Nothing extra shall be paid extra on this account. |
| 5 | [g] Contractor shall rectify the defects within 24 hours as per directed by the Engineer-in-Charge.[h]Contractor shall maintain the Temperature of AC Plant as per the direction of GE / AGE / User or their Representative as per the Design Conditions at all times.[i] Necessary Tools and Plants like Centrifugal Pump 0.5 HP, Vacuum Pump 1 HP and connecting Rubber Tube, Pressure Gauges, Flaring Nuts etc. and Safety Equipment / Tools for tradesman shall be readily available at site during contract period. [j]Periodical cleaning of Cooling Tower, AHU Filters & Chemical servicing of Cooling Tower shall be the Contractor\"s responsibility.[k]The contractor shall arrange Dry/Wet Bulb Thermometer for recording hourly room temperature. Room Temperature and Humidity Display Unit / Instrument shall be provided at Plant Room for continuous monitoring.[l]On completion of comprehensive maintenance the contractor shall carryout the complete system and controls functional tests before handing over of the plant to department or his successor in presence of user and Engineer-in-Charge. If any components / spares are found defective or unserviceable, the contractor shall replace the same at his own cost in presence of user and Engineer-in-Charge and a certificate to this effect and tests carried out duly signed by the contractor, user and Engineer-in-Charge shall be submitted before claiming the final Bill. |
| 6 | [m]Collective / Selective control by carrying out periodical checks, repairs and testing as specified and as recommended by the manufacturers and as directed by the Engineer-in-Charge to ensure smooth, safe and efficient operation including all spares / accessories etc. of compatible make as specified by the OEM complete and all as specified and as directed.[n]Preventive and breakdown maintenance of all the equipment by regular Oiling, Greasing etc. as per OEM recommendations. [o]To take care of housekeeping, environmental cleanliness of area up to 5m all around installation shall be kept absolutely neat and clean.[p]To maintain all installations provided under this contract as per IE Rules / Standard Engineering Practice and maintenance of installation Log Book and Maintenance Register.[q]The cost of the Complaint Slips, Registers, Log Books, Cost of T & P for Maintenance.[r]Emergency Light and necessary tools shall be available in a tool box with the Electricians and Refrigeration Mechanics in the shift for smooth functioning of AC Plants. [s]Conveyance and communication system like mobile phone etc. shall be provided by the contractor to all Electricians and Refrigeration Mechanics.[t]The contractor shall abide by the latest Labour Rules and Minimum Wages Act. Wages paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State / Central Government from time to time whichever is higher. The contractor shall also insure the workmen employed on the job. |
| 7 | [u]The contractor is responsible for Insurance, EPF, ESI, Gratuity, Bonus, Labour Welfare Cess etc., as applicable and shall be paid to the Workmen as per existing Labour Rules / Acts / Regulations and rate quoted shall be deemed to be included for the same. [v]DRESS CODE: The contractor shall provide the workmen with Dark Blue Colour uniform with labels showing the Name of Firm and the Designation and \"GE [U – II] [V]\" printed on them along with protective clothing. The contractor shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes.[w]INSURANCE: The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of AC Plants / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations.[x]The rate quoted by the contractor shall be deemed to be including Basic Rate [Minimum Wages as notified by Government of India / State Government / Local Body, whichever is higher], employer\"s contribution towards Employees Provident Fund [EPF] liability, contribution towards Employees State Insurance Corporation [ESIC], contribution towards Bonus, Overhead and Profit and Labour Welfare Cess [LWC] as applicable depending upon the manpower requirement. This will create onus on the contractor to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all Taxes, Cess, Levies as applicable including GST. |
| 8 | Supply only compressor oil suitable for R-22/HCFC type Mineral lubricant complete all as specified and as directed. |
| 9 | Supply only compressor oil suitable for R-134A/R-407C/410AHFC type polyolester lubricant complete all as specified and as directed. |
| 10 | Supply only Copper Refrigerant tube of 1/2\" Outer Dia minimum 1mm thick for condenser of AC Plants complete all as specified and directed. |
| 11 | Supply only Insulation of Copper pipes of DVRF/Ductable/Package AC Systems complete all as specified and as directed. |
| 12 | Supply only DLT sensor as per plant model and capacity complete all as specified and as directed.. |
| 13 | Supply only Gas Sensor & Pipe Temp Sensor as per plant model and capacity complete all as specified and as directed. |
| 14 | Supply only Liquid Sensor & Room Temp Sensor as per plant model and capacity complete all as specified and as directed. |
| 15 | Supply only High pressure cut-out MP-1 for central type A/c plants complete all as specified and as directed. |
| 16 | Supply only Low pressure cut-out MP-1 for central type A/c plants complete all as specified and as directed. |
| 17 | Supply only Oil pressure cut-out MP-55 for central type A/c plants complete all as specified and as directed. |
| 18 | Supply only HRC fuses 6/12/20 Amps rating complete all as specified and as directed. |
| 19 | Supply only HRC fuses 32/63/100 Amps rating complete all as specified and as directed. |
| 20 | Supply only MCB SP, 6 to 32 Amps, 10 kA, AC, 240 V, 50 Hz complete all as specified and as directed. |
| 21 | Supply only MCB SPN 32 Amps, 10 kA, AC, 240 V, 50 Hz complete all as specified and as directed. |
| 22 | Supply only MCB TP, 25 to 63 Amps, 10 kA, AC, 415 V, 50 Hzcomplete all as specified and as directed. |
| 23 | Supply only MCB TPN, 16 to 32 Amps, 10 kA, AC, 415 V, 50 Hz complete all as specified. |
| 24 | Supply only MCCB, 3 Pole, 63 Amps, 16 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 25 | Supply only MCCB, 3 Pole, 100 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 26 | Supply only MCCB, 3 Pole, 125 Amps, 25 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 27 | Supply only MCCB, 3 Pole, 250 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 28 | Supply only MCCB, 3 Pole, 400 Amps, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 29 | Supply only MCCB, 4 Pole, 250 Amps, 36 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 30 | Supply only MCCB, 4 Pole, 400 Amps, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 31 | Supply only MCCB, 4 Pole, 630 Amps, 50 KA, 415 Volts, 3 Phase, AC, 50 Hz, Adjustable type complete with Overload Protection, no-volt thermal based release complete all as specified and as directed. |
| 32 | Supply only power contactor coil, 230 Volts, 12 Amps rating complete all as specified and as directed. |
| 33 | Supply only Power Contactor of MNX-9, 25 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 1NO + 1NC complete all as specified and as directed. |
| 34 | Supply only Power Contactor of MNX-18, 30 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 1NO + 1NC complete all as specified and as directed. |
| 35 | Supply only Power Contactor of MNX-25, 45 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed. |
| 36 | Supply only Power Contactor of MNX-32, 55 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed. |
| 37 | Supply only Power Contactor of MNX-50, 85 Amps, 3 Pole with coil voltage of 240Volts, 50 Hz with 2 NO + 2 NC complete all as specified and as directed. |
| 38 | Supply only bimetal over load relay of 16/20 Amps capacity complete all as specified and as directed. |
| 39 | Supply only bimetal over load relay of 32/63 Amps capacity complete all as specified and as directed. |
| 40 | Supply only \"V\" beltfor powertransmission of any type and size as per sample and site reqmt complete all as specified and directed. |
| 41 | Supply only in replacement of pre-filter, cleanable type, made of non woven synthetic media with GI frame, Box / Bag type, having efficiency 90% down to 10 microns, of existing shape and size complete all as specified and as directed. |
| 42 | Supply only in replacement of MICRO-VEE5 micron fine-filter, cleanable type, made of non woven synthetic media with GI frame, Box / Bag type, having efficiency 97% down to 3 microns, of existing shape and size complete all as specified and as directed. |
| 43 | Supply only, in replacement, of pressure gauge, dial type, with siphon assembly,suitable to fix on existing chiller pipe lines, complete all as specified and as directed. |
| 44 | Supply only pressure relief valve of condenser 3/8\" BSP threaded suitable for 300 PSI complete all as specified and as directed. |
| 45 | Supply only refrigerant gas 134A to A/C system complete all as specified and as directed. |
| 46 | Supply only refrigerant gas R-22 to A/C system complete all as specified and as directed. |
| 47 | Supply only refrigerant gas R-410A/407/404A to A/C system complete all as specified and as directed. |
| 48 | Supply only nitrogen gas for leak testing of central A/C plant system complete all as specified and as directed. |
| 49 | Supply only Single Phase Preventor, 415 Volts, Type VSP-2 Auto Reset 40 Volts unbalance complete all as specified and as directed. |
| 50 | Supply only ET-100, 9 to 30 Seconds, 240 / 215 Volts complete all as specified and as directed. |
| 51 | Supply only strip type heaters of capacity 1.5/2 KW suitable for AHU of central AC plant of any capacity complete all as specified and as directed. |
| 52 | Supply only strip type heaters of capacity 3.0 KW suitable for AHU of central AC plant of any capacity complete all as specified and as directed. |
| 53 | Supply only thermometer of range 0 F to 100 F to condenser / chiller inlet or outlet pipe complete all as specified and as directed. |
| 54 | Supply only Unloader Power Element Suitable for compressor of existing model and make complete all as specified and as directed. |
| 55 | Supply only Thermostatic Expansion Valve MIV 34/HVE-11/16/34 suitable for Central AC Plants complete all as specified and as directed. |
| 56 | Supply only Motor coupler sleeve with key suitable for Centrifugal pump sets of 3 to 7.5 HP Capacity of existing make complete all as specified and as directed. |
| 57 | Supply only Display unit and PCB board suitable for up to 7.5 TR capacityAir Cooled Units package type including testing complete all as specified and as directed. |
| 58 | Supply only Display unit and PCB board suitable for above 7.5 TR but up to 15 TR capacityAir Cooled Units package type including testing complete all as specified and as directed. |
| 59 | Supply only Display unit and PCB board suitable for above 15 TR but up to 25 TR capacity Air Cooled Units including testing complete all as specified and as directed. |
| 60 | Supply only Programmable control board,expansion board and display board suitable for above 25 TR but up to 66 TR capacity Central Type Water Cooled Units including testing complete all as specified and as directed. |
| 61 | Supply only Programmable control board,expansion board and display board suitable for above 80 TR but up to 110 TR capacity Central Type Water Cooled Units including testing complete all as specified and as directed. |
| 62 | Supply only Blower Fan of AHU as per existing size and make including necessary fixing arrangement complete all as specified and as directed. |
| 63 | Supply only in replacement of un-armoured 1.5Sqmm (nominal area), PVC insulated, 6 core, unsheathedcopper conductor cable, ISI marked and making all electric connections for AHUcontrol remot panel toVarious AHUscomplete all as specified and as directed. |
| 64 | M & L for disconnecting Motor of capacity 3 HP from the existing Compressor/AHU/Chiller / Condenser Pump Set / Cooling Tower, and carrying to work shop and Rewinding the motor with appropriate gauge super enamelled copper conductor, varnishing, drying, replacement of Bearings with new Bearings, worn-out bushes, connectors, terminal plate and fixing back in original position, connecting cable through terminal block, applying Two coats of synthetic enamel paint of approved tint including preparation of surfaces and including testing on completion, complete all as specified and as directed. |
| 65 | All as per Item No. 58 butof capacity 5 HP to 7.5 HP. |
| 66 | All as per Item No. 58 but of capacity 10 HP to 12.5 HP. |
| 67 | All as per Item No. 58 butof capacity 15 HP to 20 HP. |
| 68 | All as per Item No. 55 but of capacity 22.5 HP to 30 HP. |
| 69 | Supply only terminal block suitable for existing motor of capacity upto 30 HP. |
| 70 | Supply only PVC Fan blade suitable for existing motor of capacity upto 30 HP. |
| 71 | Supply only bearings and bushes suitable for existing motor of capacity upto 30 HP. |
| 72 | Supply Only Hermatic sealed Scroll Compressor suitable for water cooled AC plant of capacity 3x25 TR comaptible to R 407C/R134A/R410A including repair/replacement of control wiring,connecting up all controls and refrigerant piping after necessary modifications as required for system,pressure testing with nitrogen gas under constant pressure as specified by OEM for minimum 24 hrs vacuumising,Gas charging,commisioning and checking the performance of the system complete all as specified and as directed |
| 73 | Supply Only Hermatic sealed Scroll Compressor suitable for Air Cooled AC plant of capacity 4x5.5 TR comaptible to R 22 including repair/replacement of control wiring,connecting up all controls and refrigerant piping after necessary modifications as required for system,pressure testing with nitrogen gas under constant pressure as specified by OEM for minimum 24 hrs vacuumising,Gas charging,commisioning and checking the performance of the system complete all as specified and as directed |
| 74 | Supply onlyDry / Wet Bulb Hand Operated Sling Psychrometer complete all as specified and as directed. |
| 75 | Supply onlyDigital indoor cum outdoor Thermo-hygrometer with clock complete all as specified and as directed. |
| 76 | M & L for dismantling & repairs of Centrifugal pump sets of capacity up to 5 HP and including replacement of bearings with new bearings, cleaning with Kerosene / Petrol for removing the scales, replacement of Case Ring, Latern Ring, Shaft Sleeve, CI Gland Covers with MS Studs, Ball Bearings, Coupling Key, Rubber Bush, Nut, Bolts, Impeller Key, Lock Washer, Gasket, Greasing etc., re-assembling same in position, applying a coat of water proof epoxy paint on external surfaces of pump, testing and commissioning complete all as specified and as directed. |
| 77 | All as per Item No. 70 but 7.5 HP to 12.5 HP Pump Capacitycomplete all as specified and as directed. |
| 78 | All as per Item No. 70 but 15 HP to 20 HP Pump Capacitycomplete all as specified and as directed. |
| 79 | Supply only GM impellers for Centrifugal/ Monoblock pump with key and bushes suitable for existing pump set of capacity upto 5 HP |
| 80 | Supply only GM impellers for Centrifugal/ Monoblock pump with key and bushes suitable for existing pump set of capacity 7.5 HP to 12.5 HP |
| 81 | Supply only GM impellers for Centrifugal/ Monoblock pump with key and bushes suitable for existing pump set of capacity 15 HP to 20 HP |
| 82 | Supply only Pump Shaft sleeve for Centrifugal /Monoblock pump with key suitable for existing pump set of capacity upto 5 HP |
| 83 | Supply only Pump Shaft sleeve for Centrifugal /Monoblock pump with key suitable for existing pump set of capacity 7.5 HP to 12.5 HP |
| 84 | Supply only Pump Shaft sleeve for Centrifugal /Monoblock pump with key suitable for existing pump set of capacity 15 HP to 20 HP |
| 85 | Supply onlyBearing & bushfor Centrifugal /Monoblock pump suitable for existing pump set of capacity upto 5 HP |
| 86 | Supply onlyBearing & bushfor Centrifugal /Monoblock pump suitable for existing pump set of capacity 7.5 HP to 12.5 HP |
| 87 | Supply onlyBearing & bushfor Centrifugal /Monoblock pump suitable for existing pump set of capacity 15 HP to 20 HP |
| 88 | Supply only Metallic hub for jaw / star coupling suitable for 7.5 HP to 20 HP pump set |
| 89 | Supply and fix fully Automatic Star Delta Starter in Sheet Steel enclosure / Panel mounting type suitable for 15 HP to 25 HP, AC, 3 Phase, 415 V, 50Hz induction motor incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay for motor protection and Electronic Star Delta Timer including taking down existing unserviceable starter of any description complete all as specified and directed |
| 90 | Supply and fix DOL starter in Sheet Steel Enclosure incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay with manual re-set and yellow flag for trip indication suitable for up to 12.5 HP, AC, 3 Phase, 415 V, 50Hz induction motor including taking down existing unserviceable starter of any description complete all as specified and directed |
| 91 | Material and labour for repair / maintenance of Control Panel Board of AC Plant of any capacity including renewal of defective control wiring, lugs, cable glands, decarbonising of bus bars including changing of burned bus bars if necessary, cleaning panel board externally and painting the panel board with two coats of synthetic enamel paint of existing colour code and pasting and pasting the stickers of incomer, outgoing and machinery names complete all as specified and as directed |
| 92 | Material and labour for servicing of Cooling Tower FRP Type of any capacity, replacement of ball bearings of cooling tower motors, shaft bush and carrying out repairs to Cooling Tower by taking down the Choked PVC Fills, Segments, Repair to PVC Segments,Broken Nozzles, Cleaning the Cooling Tower Fan Assembly, Overhauling of Fan Motor, Sprinkler System including replacement of defective parts such as PVC Nozzles, Mesh, Sprinkler, PVC Common Header Pipes, Valves, Bolts and Nuts including servicing of cooling tower bottom Sump, Strainer, arresting of leakages if any removing and cleaning of fungus complete including white washing the base complete all as specified and as directed. Note :- Cooling tower Fills, sprinklers & Fill Pack Sheetwill be measured and paid separately under relevant items of BOQ. |
| 93 | Supply onlyCooling tower motor of existing make and capacity suitable for Cooling Tower of AC plant of capacity up to 110 TR including taking down old unserviceable motor complete all as specified and as directed. |
| 94 | Supply onlyCooling tower fan with hub of existing make and size suitable for Cooling Tower of AC plant of capacity up to 110 TR including taking down old unserviceable fan complete all as specified and as directed. |
| 95 | Supply only PVC Fills of size 600x300x150mm suitable for Cooling Tower including taking down old unservicieable PVC fills complete all as specified and as directed. |
| 96 | Supply only Sprinkler suitable for cooling tower of any capacityincluding taking down old unservicieable sprinkler complete all as specified and as directed. |
| 97 | Material & Labour for Opening of short circuited DIDW Centrifugal Blower motor 4000 cfm, cutting and removing the burnt stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots,all necessary insulating materials, varnishing, dryining completeand refixing the same complete all as specified and directed. |
| 98 | Material & Labour for Opening of short circuited DIDW Centrifugal Blower motor 1500 cfm, cutting and removing the burnt stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots,all necessary insulating materials, varnishing, dryining completeand refixing the same complete all as specified and directed. |
| 99 | Material & Labour for Painting toMS / GI pipe line 150 / 100 / 80 mm dia for Condensor Water Pump to Cooling Tower and vice versaas per existing colors code with all supporting materials with one coat of synthetic enamel paint from ground level to bottom of the dome of the make up tank complete all as directed.Note :- Special type of tools & tackles, swings, scaffolding and safety accessories etc required for the work shall be arranged by the contractor and rate quoted shall deemed to be included for the same. |
| 100 | Material & Labour for Painting to compressor, condensor, compressor motor, Condensor Water Pump, AHU motor and Cooling Tower of AC plant capacity 3 x 20 TR to 3 x 66 TR and vice versaas per existing colors code with all supporting materials with one coat of synthetic enamel paint from ground level to bottom of the dome complete all as specified and directed. Note :- Special type of tools & tackles, swings, scaffolding and safety accessories etc required for the work shall be arranged by the contractor and rate quoted shall deemed to include for the same. |
| 101 | All as per item No. 81 above but AC Plant Capacity of 3 x 80 TR to 3 x 110 TR complete all as specified and as directed. |
| 102 | Material & Labour for replacement of Joists of Cooling Tower, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including preparation of steel surface and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 103 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, base concrete, hard standing etc complete all as specified and directed |
| 104 | S & F in repairs Butterfly Valves of Cast Iron 80 mm dia including taking down old one complete all as specified and as directed. |
| 105 | S & F in repairs Butterfly Valves of Cast Iron 100 mm dia including taking down old one complete all as specified and as directed. |
| 106 | S & F in repairs Butterfly Valves of Cast Iron 125 mm dia including taking down old one complete all as specified and as directed. |
| 107 | S & F in repairs Butterfly Valves of Cast Iron 150 mm dia including taking down old one complete all as specified and as directed. |
| 108 | S & F in repairs Cast Iron Non Return Valve with bypass arrangement with suitable flanges, suitable for100 mm bore pipes conforming to IS – 5312, Class PN –1.6, including necessary nuts, bolts, washers, rubber gasket etc for jointing and taking down old one complete all as specified and as directed. |
| 109 | S & F in repairs 50 mm thick EPS insulation for MS piping of Chilled Water of Size 65 to 125mm dia of 16 KG / Cu.m density covered with wire mesh & cement plaster or Aluminum Cladding complete all as specified and as directed. |
| 110 | M & L for Under Deck Insulation for metal roof with bonded fibre glass wool of density 16 Kg / Cu.m, 50 mm thick, suitably factory laminated with aluminium foil backed up by scrim and Kraft paper packing with 50 mm projection for overlap and butting comprising of the following complete all as specified and as directed:[a] Insulating material shall confor to BS-476, Part 4, 5, 6 & 7.[b] S & F 6 mm dia MS Rods between purlins suitable for supporting the thickness of insulation material beneath the metal roof.[c] S & F 22 SWG GI Wire support for insulation.[d] S & F Chicken Wire Mesh 12.5 mm 22 SWG of hexagonal construction below the insulation for supporting the same. |
| 111 | Taking down old serviceable GI Ducts of any size and shape from existing ducting and refixing the same after reconditioning of duct by replacing necessary gaskets, nuts, bolts and other required accessories complete all as specified and as directed. |
| 112 | Supply only Y type Strainer, 125 / 100 mm dia including replacement of filter, packing, nuts and bolts complete all as specified and as directed. |
| 113 | All as per Serial Item No. 93 above but of size 80mm bore complete all as specified and as directed. |
| 114 | S & F GI Sheet of 22 Gauge with TDF Flange as in Rectangular / Square Duct made out of \"L\" shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc. including fabrication and erection complete all as specified and as directed. |
| 115 | Supply only Fire / Fresh Air Dampers suitable for AC Plants of up to 110 TR Capacity complete all as specified and as directed. |
| 116 | M & L for Pre - insulated MS pipe, 100 mm dia, Class \"C\" having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI cladding including taking down of existing pipe complete all as specified and as directed. |
| 117 | M & L for Pre - insulated MS pipe, 125 mm dia, Class \"C\" having thickness of PUF insulation 36 mm of density 36 Kg/Cum and 26 gauge GI claddingincluding taking down of existing pipe complete all as specified and as directed. |
| 118 | Supply and lay MS pipe,125mm dia, heavy grade with all fittings laid in floor or fixed to walls and ceilings all as directed |
| 119 | Supply and lay MS pipe,200 mm dia, heavy grade with all fittings laid in floor or fixed to walls and ceilings all as directed |
| 120 | S & F in repairs, Gun Metal Globe or Gate Valve of Class - I Pressure Tested of 1.5 Mpa, 50 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked, including taking down old one complete all specified and as directed. |
| 121 | All as per Serial Item No. 101 above but of 40 mm bore complete all as specified and as directed. |
| 122 | All as per Serial Item No. 101 above but of 25 mm bore complete all as specified and as directed. |
| 123 | All as per Serial Item No. 101 above but of 20 mm bore complete all as specified and as directed. |
| 124 | S & F Rotational Moulded Polythene HDPE Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 1000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed. |
| 125 | S & F Rotational Moulded Polythene HDPE Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 2000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed. |
| 126 | S & F Rotational Moulded Polythene HDPE Water Tanks, Triple Layered, ISI Marked, Cylindrical & Vertical Type 5000 Litres Capacity hoisted and fixed in position including provision of 40mm/25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed. |
| 127 | S & F in repairs Ball Valves, 20 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 20mm - 210 Grams] etc complete all as specified and as directed. |
| 128 | S & F in repairs Ball Valves, 25 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 25mm - 455 Grams] etc complete all as specified and as directed. |
| 129 | S & F in repairs Ball Valves, 40 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe [Minimum Weight 40mm - 690 Grams] etc complete all as specified and as directed. |
| 130 | M&L for disconnecting existing tanks,setting aside (or lowering if required) for repairs,cleaning etc and hoisting if required reconnecting and re-fixing in position for tank capacity of 500 ltrs all as specified and directed.Note:- Cleaning and removing scales and dirt from tank will be measured under this item. |
| 131 | All as per item No 111 for capacity 1000 ltrs |
| 132 | All as per item No 111for capacity 2000 ltrs |
| 133 | All as per item No 111for capacity 5000 ltrs |
| 134 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall / pole 1100 volts gradeXLPE insulated, armoured heavy duty electric cableswith stranded aluminium conductorof cross sectional area 240 Sqmm 3.5 core complete all as specified and as directed. |
| 135 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall / pole 1100 volts gradeXLPE insulated, armoured heavy duty electric cableswith stranded aluminium conductorof cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed. |
| 136 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall / pole 1100 volts gradeXLPE insulated, armoured heavy duty electric cableswith stranded aluminium conductorof cross sectional area 400 Sqmm 3.5 core complete all as specified and as directed. |
| 137 | M&L cable jointing kit (1.1KV) straight through type (Heat shrinkable) for XLPE insulated, armoured heavy duty electric cableswith stranded aluminium conductorof cross sectional area 240 sqmm 3.5 core to 300 Sqmm 3.5 core complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail