| 1 | Demolition of brick work in cement mortar incl all quions, arches, pillers etc, but excluding ashlar facing, dressed stone work and precast concrete articles completeall as specified and directed. |
| 2 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 M mean radius built in CM 1:4 completeall as specified and directed. |
| 3 | Taking down cement plaster on brick or stone wall etc including raking out joints hacking for keys scrubbing down with water etc. completeall as specified and directed. |
| 4 | M&L for 15 mm thick rendering in CM 1:4 on onother than fair faces of brickwork or concrete surafaces complete all as specified and directed. |
| 5 | M/L for two coats of white wash on walls including preparation of newplaster surfaces completeall as specified and directed. |
| 6 | Demolition of Cement concrete (unreinforced) of any description and in any position, surface channels etc. not otherwise specifically provided for complete all as specified and directed |
| 7 | M&L 50mm thick plain cement concrete M-20 (nominal mix) using 20mm graded stone aggregate as in flooring complete all as specified and as directed. |
| 8 | M&L for75 mm thick plain cement concete PCC (1:3:6)type C-1 using 20mm thick stone aggregate as in plinth protection and finish the surface using extra cement and making XPM inpression whilst the concetre is green complete all as specified and as directed. |
| 9 | Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed. |
| 10 | M&L for Machine pressed precast conctete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade completeall as specified and directed. |
| 11 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 12 | Demolition of RCC of any description and any position not othervise provided for complete all as specified and directed. |
| 13 | M&L for providing Precast re-inforeced cement concrete PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in man hole cover slab set in cement mortar 1:6 complete all as specified and directed. |
| 14 | M&L TMT bars 10 mm dia and over cut to length bend to shape as required, including cranking, bending spirally for hoping for columns hooking ends and binding with MS steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed. |
| 15 | Demolition or breaking up drain pipes (salt glazed ware) set in cement mortar, internal dia of pipe 150 mm complete all as specified and directed. |
| 16 | M&L for Reinforced concretepipes, class NP2, bore of pipe 150 mm laid and jointed complete with collars complete all as specified and as directed. |
| 17 | M&L for concrete bed to drain pipes including packing under and haunching against sides of pipes after they laid and tested in PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate for 150 mm bore pipes complete all as specified and directed. |
| 18 | Demolition of PVC drain pipe of any size including all fittings head, shoes, bend and crowl set in CM complete all as specified and directed. |
| 19 | S&F PVC (SWR) pipes 110 mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 20 | S&F PVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 21 | S&F PVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed. |
| 22 | S&F PVC (SWR) junction single (single T) equal or unequal for 110 mm bore pipes complete all as specified and directed. |
| 23 | S&F PVC (SWR) bends any radius for 110 mm bore pipes complete all as specified and directed. |
| 24 | S&F PVC (SWR) bends any radius for 75 mm bore pipes complete all as specified and directed. |
| 25 | S&F PVC (SWR) cowl any radius for 110 mm bore pipes complete all as specified and directed. |
| 26 | S & F in repair, 10 Litres, PVC valve less, symphonic action type, Flushing Cistern, low level, white with inlet, ball valve, float and handle including brackets and connection to pipes fixed complete all as specified and directed. |
| 27 | S/F PVC connection 15mm size with PTMT nuts of length 600mm. |
| 28 | S&F in repairs Vitreous china (white) wash down water closet pan (pedestal pattern) EWC with \"P\" & \"S\", trap front or back inlet and foot rests, any pattern incl PVC seat cover (excluding flushing cistern and flush Pipe) complete including provision of lime concrete complete all as specified and directed. |
| 29 | Dismantling floor hearth or wall tiling including cement mortar bedding (But not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 30 | M&L fornon-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bedin CM 1:6 complete all as specified and directed. |
| 31 | M&L for joint free glazed ceramic colouredtiles 300 x 250 x 7 / 450x350x7mm thick,set and jointed in neat cement slurry & pointed with colouredcement to matchover 10 mm rendering in CM 1:4 complete all as specified and directed |
| 32 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 33 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed. |
| 34 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge,gutter, fixed with self tapping screws all as specified and as directed. |
| 35 | Dismantling Asbestos cement (corrugated and semi-corrugated etc sheet) in roof coverings complete all as specified and directed. |
| 36 | M&L6 mm thick asbestos cement, corrugated or semi-corrugated sheet fixed with coach screw in roofs walls etc complete all as specified and directed. |
| 37 | S&F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections complete all as specified & directed. |
| 38 | S&F in repairs 15mm dia bib taps bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipes or for brass ferrule complete all as specified and as directed. |
| 39 | S&F in repairsstop valves cast copper alloy chromium platedwith long shank and cup (concealed type) fancy type screwed down high pressure screwed both ends for pipe or union fixed for 15mm bore complete all as specified and directed. |
| 40 | S&F in repars vitreous china wash basin, white flat back of size 550mm x 400mm, excluding tap incl bracket, waste pipe , connector pipe complete all as specified and as directed. |
| 41 | S&F in repars 15mm bore dia Pillar taps, cast copper alloy chromium plated, fancy type, screwed down, high pressure with or without lettered \"HOT\" or \"COLD\" with long screwed shanks and fly nut complete all as specified and as directed. |
| 42 | Cleaning of manhole by taking out sludge in semi liquid/solid stage from inside of manhole of depth not exceeding 1.5 M & removing the sludge to distance not exceeding 50 M and deposited in trenches, sprinkling bleaching powder and covering sludge with earth to a thickness not less than 30 CM including all earth work returning filling removal of surplush soil and necessary temporary bamboo barricades complete all as specified and directed. |
| 43 | All as per item Ser No. 42.00 above but depth exceeding 1.5 M not exceeding 3 M etc. complete all as specified and directed. |
| 44 | Cleaning the salt glazed stone ware soil/waste pipe 150mm dia by roading from manhole to manhole and manhole to septic tank cleaning with rod/bamboo and removal all blockage etc complete and testing including making good the distrubed area/surface existing complete all as specified and directed. |
| 45 | All as per item Ser No 44.00 above but 100 mm dia soil/waste pipe. |
| 46 | M&L for cleaning and removing of sludge/mud from septic tanks / soakage well of any depth & description by mechanical means complete all as specified and directed by Engineer-in-Charge. |
| 47 | Cleaning of gully trap/nahanitrap/ S trap for WC/EWC all as specified and directed.Note : The work is to be carried out in overflow and foul condition. Necessary precautionary measure shall be included in quoted rate. |
| 48 | Cleaning of SWT from bottom by De-watering by submerssible pump and taking out solid sludge to be disposited at low laying area, Necessary walland wall repair with water proofing compound and painting to welded fabric wiremesh & iron angles, white washing to complete internal wallsof tank complete all asspecified and directed and upto the satisfaction of Engr-in Charge. |
| 49 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 50 | S&F Welded steel wire fabric n.exc 4 kg/sqm fixed to wood or steel members complete all as specified and as directed. |
| 51 | S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 GdeE-165 complete all as specified and as directed. |
| 52 | M&L for preparation of new or previously untreated steel surfacess of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 53 | M&L for providing cemnet concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 54 | Taking down unserviceable rolling shutters/sliding gates for repairang necessary greasing and replacement of UNSV portion like anchoring road, ball bearing, shutter etc and re fixing same openingcomplete all as specified and directed. Note :- Spare parts required shall be measured and paid for separately under relevant item as Supply only. |
| 55 | M&L mild steel round bars Fe 410-W (Gde-E- 250) quality-A, in available lengths complete all as specified and directed. |
| 56 | Supply onlyBall bearing for rolling shutter complete all as specified and directed |
| 57 | S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 58 | S&FMild steel, corrugated, blacksheet, 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc. as required complete all as specified and as directed. |
| 59 | S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and as directed. |
| 60 | M&L old wall surfacesand applying one coat of cement base paint (camouflage pattern) complete all as specified and as directed. |
| 61 | M&L new wall surfacesand applying two coat of cement base paint (camouflage pattern) complete all as specified and as directed. |
| 62 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 63 | Excavating in post holes in soft/loose soil n. exc. 0.5 cum and getting out returning, filling in and ramming in layers n. exc. 25 cm, watering and removing surplus soil to a distance n.exc. 50 mtr and making good the surface complete all as specified and as directed. |
| 64 | M&L PCC 1:4:8 type D2 (40mm graded aggregate) as in foundation, filling & mass concrete complete all as specified and as directed. |
| 65 | S/F MS steel post struts fencing post including cutting top to shape, drilling holes notching for wire etc. including all necessary drilling bolting andd similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 66 | Dismantling fencing wiremesh any type & of any description complete all as specified and as directed. |
| 67 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directed. |
| 68 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standrad , rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 69 | S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc. complete all as specified and as directed.Note : Each line of wire to be measured. |
| 70 | S&F in repairs Concertina coil 600mm Dia/56 Loops/2.5 mm core wire. Coil Diameter:600 mm. Type of Strip: Heavy Galvanized (IS 1730) Type of Core Wire: Heavy Galvanized (IS 280-2006) Core wire Diameter:2.50mm Dia Zinc coating to Strip: Minimum 200 GSM/Sq mm, Zine Coating on wire: Minimum 275 GSM/Sq mm (IS 6745-1972 reaffirmed 2006). Tensile Strength of wire 1400-1500 N/Sq mm Weight: 14.63 Kg (+5%) Number of Loops: 56Blade Length: 22mmBarb Profile Medium Blade (MBBT)Distance Between Barb35mm.Strechable length 12 mtrs. Type of clip Hardened Steelin Galvanized steel. |
| 71 | M &L for preparation of new steel surfaces and applyingtwo coats of black bituminious paintexceeding 10cm in width or girth complete all as specified and as directed. |
| 72 | M&L forVitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 73 | M&L forVitrified Ceramic tiles light shade 10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm in wall etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM (1:4) complete all as specified and as directed. |