| 1 | 4 Nos. complete Pump set of 180 m3/15mtr Head or main Pumping station with all required accesories |
| 2 | (SCRAPPER MECHANISM) Repairing of scrapper mechanism of sludge thickener by repairing/replacement of central rotating mechanism, repairing/ replacement of worn out scrapper structure, angles, flats etc, replacement of sweeping rubber, repair/ replacement of flat below bridge wheel for smooth movement of the brdige along with painting and all required jobs. |
| 3 | Providing and Fixing guide pipe 3-4` to guide lowering and lifting of motors in STP MPS complete. CI construction for standard applications. Standard kit contains a base, a pump adapter for will all requied bolts and fittings, and the upper guide rail positining bracket (FOR 1 NO MOTOR) |
| 4 | Repair of Sensor of online monitoring device along with replacement of data logger Modem, RS 485 Cable and all required accessories for data transfer from OMD to HSPCB and CPCB ServerMake : - XYLEM |
| 5 | Repairing of 2 Nos Sluice Gates Installed at incoming Receiving Chamber of MPS by Repacement of Screws,Nuts and Guides Complete in all respects for proper operation |
| 6 | Replacement of Remote Transmission Unit of Outlet flow meter along with data logger Modem, RS 485 Cable and all required accessories for data transfer from OMD to HSPCB and CPCB Server MAKE: - CIMCON |
| 7 | -Providing and Fixing of Main Control Panel made up of 16/14 guage CRCA sheet, consisting of 400 A MCCB incomer with 400 A change over switch, phase indicators switch, fuses volt meter and ampere meter, Aluminum bus bar, 6 no. outgoing MCCBH 160 Amp MCB 63 Amp including all connections etc |
| 8 | Complete submersible pump sets fo 50 m3/ hr having head 8 mtr with complete DI fittings, valves and accessories (BLENDING SUMP) |
| 9 | Integrated Electrical panel with PMU unit for 2 pumps of 50 m3/ hr, 8 metre head |
| 10 | Laboratory refrigerators Purpose:-To preserve samples. Storage Temperature0-20 degree Celsius ,Vertical Shelves atleast 6 for storage of samples, Storage Capacity 500 Litres along with the in built-digit al temperature controller(company fitted ).Door for restricted accessibility.Castor wheels for easy mobility .Toughened glass door.NABL calibration certificate.1 year warranty(Make- CELLFROST,HAIR, WHIRLPOOL,Voltas) |
| 11 | Manifold filtration Assembly (6 Branch) Purpose: Manifold combine a number of separate filtration components into a single.•?Branch - 6 Place assemblies •?Funnel capacity- Minimum 300ml. Filth pore size -Minimum 20µm •?Funnel material – All SS 316 within built SS Clamp and SS lid Glass or SS316 with external ss clamp and cork capacity 250 ml •?Vaccum flask 2 ltr capacity •?Valve - PTFE •?Base holder – stainless steel 316L , Autoclavable-121 °c(15min.) •?Membrane filter 1 pack(100 No.) as per requirement /0.45µm pack of 100 (Make:- PALL LIFESCIENCES, Merck Millipore, Borosil,Labotroni cs/Athena/Axiva/ Glassco |
| 12 | Providing and Fixing of Automatic Power Factor connection capacitor panel automatic APFCR - 125KVAR complete with relay, capacitors, conductors, switch etc to maintain power factor 0.95 |
| 13 | Supply, installation, testing and commissioning of screw pump set complete with all fittings for transfr of sludge from sludge thickener to drying beds |
| 14 | Weighing Balance/ Analytical Balance Purpose: It is a highly sensitive lab instrument designed to accurately measure mass. Analytical Balance Capacity 220 gm Accuracy 0.1 mg with internal calibration Pan Size Ø 90 mm. Along with NABL Calibration certificate. Acrylic sheet cabinet box, as required by laboratory. 1 year warranty.(Make- Radwag, Mettler Toledo, Sartorius, Shimazhu) |