Tender For Special Repairs Of Apfc Panel At Cmph And Gunjkheda Pump House At Mil Stn Pulgaon
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Feb 2025
0 days left
EMD
49680
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
pulgaon → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repairs Of Apfc Panel At Cmph And Gunjkheda Pump House At Mil Stn Pulgaon
BOQ
| Sl. No. | Item Description |
| 1 | Taking out HT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof including taking out of brick layer and sand from trenches completeallas directed by Engr-in-Chrage. |
| 2 | Dismantling and taking out the existing unserviceable (damaged/broken) or Unserviceable APFCPanel of any type and anysize, from Locationand removal from site all as directed by Engr-in-Chrage. |
| 3 | Supply, laying and testingLTXLPE120 Sq mm 3.5 core insuated PVC bedded galvanised steel strip or wire armoured earthed electric power cable with aluminium conductor 1100 volts grade, heavy duty in trenches/along pole or wall of following sizes complete all as specified and directed by Engineer-in-Charges. Make : Havells/Polycabe |
| 4 | Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe90 mmsize of following sizes as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed. |
| 5 | Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind ofsoil complete all as specified and as directed by EIC.. |
| 6 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm insoft/loosesoil. complete all as specified and directed Engr-in-Chrage. |
| 7 | Removing excavated material/soil to a distance not exceeding 50mand depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and directed Engr-in-Chrage. |
| 8 | Supply & laying in repair galvanized steel tubing \"light grade\"80 mm bore with all fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified& directed by Engr-in-Chrage.. |
| 9 | S&F Advance Static Voltage generator 100 kvar operating on 415 Volt 3 Phase 50Hz Ac supplyand sensing from the CT installed in the HT/LT indoor panel complete with IPCT for correcting the vector Rated Voltage AC 400V with 200 Amp MCCB protection & 10\" exhaust fan to the cabinet,Input Voltage Range AC 308~480V, Rated Frequency 50(60)Hz±10%, Redundancy Each Module is an independent reactive compensation system, Reactive Power Compensation Capability Both inductive and capacitive reactive power, Reactive Power Compensation Performance Cos𝜑≥0.99 after compensation, Imbalance CorrectionCapability Mitigate negative and zero sequence, Full Response Time <20ms, Instant Response Time <100us, Thermal Loss ≤3% of SVG rated capacity, Output Current Limitation Automatic(100% rated capacity), Cooling method Intelligent forced air cooling and chamber mountedon angle iron legsimbedded in PCC (1:4:8) block type D-2( 40 mm graded agg. of suitable Sizeincl connection of cable with lugsof suitable size. (i)Multifunctional: Reactive power and imbalance compensation(ii) Excellent reactive compensation: High speed, Precise (-0.99≤Cosφ≤0.99), Step-less, Bi-directional (capacitive and inductance) compensation(iii) Excellent imbalance correction: Both negative and zero sequence, mitigates neutral current(iv) Wide input voltage & frequency range, adapts to tough electrical environment(v) Low thermal loss (≤3% of rated SVG capacity), efficiency ≥ 97%(vi)High stability: Infinite impedance to grid, avoids harmonic resonance problem(vii) Flexible application: Modular design, embedded in standard or customized cabinet(viii) Easy installation and maintenance: Easy installation for APF module replacement and expansion(ix) Wide capacity range: 100kvar~300kvar for a single cabinet, (x) Complete protection: Grid over/under voltage, SVG over current, over temperature, and others. All faults recorded inevent log, convenient for failure analysis.(x) HMI Touch panel Display to provide all information relating to the alaram & status of the SVG as well as being capable of displaying metered values. Note Power factor value should be .99 All as specified and directed by EIC. Make : L&T/Delta/Venus technocraft |
| 10 | S & F in replacementCT 200/5A ratio CL-0.5 5 VA tapewound all as specified and directed by EIC. |
| 11 | S & F in replacementCT 400/5A ratio CL-0.5 5 VA tapewound all as specified and directed by EIC. |
| 12 | Material and labour in replacement/repair for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (2009)connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm graded stone aggregate)50mm thick cover reinforced with 8mm dia TMT bars @ 100mm c/c both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm bore GI medium grade earth lead protection pipe, complete all as specified and directed. |
| 13 | Supply and fixing in replacement of galvanised iron strip 32 X 6 mm with all conecting items buried in ground for additional earthing leadall asspecified and directed by EIC. |
AI Tender Summary
Tender Timeline
Jan 15, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 04, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 10, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender