Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 min width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, for all lift, including getting out the excavated soil and disposalof surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Earth -work in exacavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5m & lead upto 30m including filling watering & ramming of excavated earth in to the trunches or in to the space between the building & the side of foundation tranches or in to the plinth removal & disposal of surplus earth as directed by engineer in charge upto a distance of 30m from the foundation trenches. (Excluding Royalty) |
| 4 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking of Earth up to 1 km |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 7 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation |
| 9 | Making R.C.C. apron Drain with apron (analysis). |
| 10 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth |
| 11 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 12 | Chlorpyriphos emulsifiable concentrate of 20% |
| 13 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: |
| 14 | With Chlorpyriphos E.C. 20% with 1% concentration |
| 15 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 17 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 18 | Cement mortor 1:6 (1 cement :6 coarse sand |
| 19 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry with 150mm/230mm/300 mm thick with Grade-I AAC blocks of density 551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class \ designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : Cement mortar 1:6 (1 cement :6 coarse sand) |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 23 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 24 | All works upto plinth level |
| 25 | All works above plinth level upto floor V level |
| 26 | T.M.T.-FE-500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping & hooks. |
| 27 | Up to Plinth Lvl- |
| 28 | Above Plinth Lvl- |
| 29 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 30 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 31 | Foundations, footings, bases of columns, etc. for mass concrete |
| 32 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 33 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 34 | Suspended floors, roofs, landings, balconies and access platform |
| 35 | Shelves (Cast in situ) |
| 36 | Stairs, (excluding landings) except spiral-staircases. |
| 37 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 38 | Weather shade, Chajjas, corbels etc., including edges |
| 39 | Edges of slabs and breaks in floors and walls |
| 40 | Under 20 cm wide |
| 41 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan areato be measured). |
| 42 | Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) |
| 43 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 44 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 45 | 10 x 140 mm |
| 46 | Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 47 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 48 | Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) |
| 49 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 50 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). |
| 51 | Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 52 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 53 | Supply and fixing Mosquitos proof jail having 5 mesh each cm. Made of 24 B.WG wire heavy quality and including cost of 25x5 mm flat iron around the jali, welding etc comlete. |
| 54 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 55 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 56 | 15 mm thick plinth plaster [1 cement : 4 coarse sand] |
| 57 | 6 mm thick plinth plaster [1 cement : 3 FINE sand] |
| 58 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 59 | Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: |
| 60 | In two coats |
| 61 | Providing and fixing 18mm thick gang saw cut (premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 62 | Granite of any colour and shade |
| 63 | Area of slab over 0.50 Sqm.( For Counter) |
| 64 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete. |
| 65 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete. |
| 66 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 67 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 68 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),ointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (Size of tiles 600x600mm) [Flooring] |
| 69 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (Size of tiles 600x600mm) [Skirting] |
| 70 | Providing and laying vitrified floor tilesin different size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)including grouting the joints with white cement and matching pigments @3.3kg/sqmetc., complete. Size of Tile 1000x1000 mm |
| 71 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 72 | Glazed Vitrified tiles Matt/Antiskid finish of size |
| 73 | size Size of Tile 600x600 mm |
| 74 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm |
| 75 | 25mm Thick Kota Stone Slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab includig rubbing and polishing complete with base of cement morter. |
| 76 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete |
| 77 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 78 | 40 mm thick with 20 mm nominal size stone aggregate |
| 79 | Providing wood work in frames of doors, windows, clerestory windowsand other frames, wrought framed and fixed in position with hold fast lugsor with dash fasteners of required dia & length (hold fast lugs or dashfastener shall be paid for separately). |
| 80 | Second class teak wood |
| 81 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 82 | Float glass panes |
| 83 | 4 mm thick glass pane (weight not less than10kg/sqm). |
| 84 | Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally. |
| 85 | 35 mm thick |
| 86 | Providing and fixing of Flush doors commercial quality conforming to I.S. 2202 part-I (1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts locks, handles spring fitting with necessary screws to be supplied departmentally. 35 mm thick |
| 87 | (a) Single leaf |
| 88 | Extra for Providing and fixing flush doors with decorative veneeringinstead of non decorative ISI marked flush door shutters conforming toIS: 2202 (Part I) for both side |
| 89 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 90 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 91 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): |
| 92 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 93 | 2nd class teak wood |
| 94 | 50x12 mm |
| 95 | Providing and fixing aluminium Tower Bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete(250x10mm) |
| 96 | Providing and fixing aluminium Sliding Door Bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete(300x16) |
| 97 | Providing and fixing aluminium Sliding Door Bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete(250x16) |
| 98 | Providing and fixing aluminium hanging floor door stopper, ISI marked , anodised transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper |
| 99 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 100 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparentor dyed to required colour or shade, with nuts and screws etc. complete 250 X 16 mm |
| 101 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : |
| 102 | (a) 250 mm x 10mm |
| 103 | (b)150x10 mm |
| 104 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 105 | 100 MM |
| 106 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 107 | Twin rubber stopper |
| 108 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 109 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 110 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 111 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 112 | 1. mm thick |
| 113 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all comers, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing confonning to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh I Glazing of plain/ toughened/ laminated/ double glass unit with I without high perfonnance coatings as per design requirements and confonning to IS: 3548 & IS: 16231 shall be paid separately.Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i)Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3(ii)Sites with structure height more than 20m for all wind speeds |
| 114 | Two track two panelsslidingwindowwithAluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (40 mm & above) x (40 mm & above) & sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). |
| 115 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 116 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.including cost of all material labour T&P etc complete required for proper completion of the work |
| 117 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with wooden primer of approved brand and manufacture including cost of all material Labour T&P etc complete required for proper completion of the work |
| 118 | Same as itemabovebutonnew wood surface. |
| 119 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 120 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 121 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 122 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coats applied @ 1.43 Itr/10 sqm overand including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 123 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 124 | French spirit polishing :13.68.1 Two or more coats on new works including a coat of wood filler |
| 125 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 126 | Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer\"s specifications including appropriatepriming coat, preparation of surface, etc. complete. |
| 127 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 128 | For fixed portion |
| 129 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 130 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 131 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 132 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/ structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 |
| 133 | Upto 5mm depth and 5 mm width |
| 134 | Painting top of roofs with bitumen of approved quality@ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : |
| 135 | With residual type petroleum bitumen of grade VG -10 |
| 136 | 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: |
| 137 | With common burnt clay F.P.S.(non modular) brick tile of class designation 1O |
| 138 | Providing & laying \"brick Coba\" 120 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of |
| 139 | coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick |
| 140 | ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 141 | Providing and laying gola 75x75mm in cement concrete M15 grade including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase. |
| 142 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 143 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape (R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 144 | Supply and installation of stainless steelBus sheltor as per attached quotation |
| 145 | Providing and fixing EV CHARGING as per attached quotation |
| 146 | Providing and Fixing door frame fabricated from sections roll formed out of 1.2mm thick galvanized steel (Base steel as per IS 513) with zinc of 120 gms/sq.mtr. The overall size of the section should be 105x60mm with rebate of 37mm for shutter. The frame section should be cut to length and metre joined with corner brackets made of CRCA electroplated.The frame should be provided with (a) 3 Nos. of M.S. powder coated 4” Butt hinges of 2mm thickness welded to the frame. (b) 6 Nos. of 1.2mm thick CRCA electroplated stiffeners should be welded to frame.(c) 6 Nos. of 8” M.S. hold fasts with split end tail welded to stiffener plates.(d) One no. aldrop receiver.(e) Each frame should be provided with 25x50mm tie rod at bottom. All welded places should be treated with protective coat of zinc rich primer.The entire frame should be provided with a coat of etched primer. |
| 147 | Providing & Fixing of window made of pre painted steel ( base Steel as per IS -513of 0.58 mm thick \" D\" quality galvanizedas per IS 277 with Zink of 120 GSM ) primer coated with epoxy primer of 5-7 microns thick , finish painted with a polyester paint of 12 -16 microns thick and back coatedwith 5-7 microns thick alkyd backer .section of outerframe should be of72 x 55 mm , centre mullion should be of72 x 50 mm , section for fixed glass beadingshould be of12 x 12 mm and sectionfor shutter should be of47 x 20 mm , outer frame and mullion section to have rebate forglazed shutters , flymesh shutters and 20 mm provision for gaurd bars / grill fly mesh shutters section should be of 20 x 40 mm. The section are to be cut to length mitre jointed with corner bracket , centre mullion to be fixed with mullion cap .Elixir or equivalent stay, handles 2nos of heavy dutystain less steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm squareguard bars with 6” (152.4mm) pitch, complete for finish item of work |
| 148 | Under ground water tank |
| 149 | PART B(PLUMBING WORKS ) |
| 150 | Sanitary Fixtures & CP Brass Fittings |
| 151 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 152 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), havingwater inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 153 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 154 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 155 | White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap |
| 156 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 157 | Kitchen sink with drain board 510x1040 mm, bowl depth 200mm. |
| 158 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 159 | Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 160 | Semi rigid pipe |
| 161 | 40 mm dia. |
| 162 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 163 | Providing and fixing toilet paper holder : |
| 164 | C.P. brass |
| 165 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 166 | 15 mm nominal bore |
| 167 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 168 | 15 mm nominal bore |
| 169 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 170 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 171 | 45 cm length |
| 172 | 15 mm nominal bore |
| 173 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 174 | Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Jaquar model. No. AKP-35761P or approved equivalent. |
| 175 | Providing and fixing health faucet with 1 m long flexible tube and wall hook including all fittings Jaquar model No.ALD-CHR-593N or approved equivalent. |
| 176 | Providing and fixing 15mm C.P brass Sink Mixer Jaquar Model. No. CON-309KN or approved equivalent.) for kitchen sink with swinging spout complete. Including cutting and making good the walls wherever required . |
| 177 | Providing and fixing of C.P. brass 600 mm size towel railJaquar Model.No. AKP-35711P or equivalent fixed with C.P. brass screws complete in all respects. |
| 178 | Providing and fixing of C.P. brass Soap Dish MakeJaquar Model. AKP-35731P or equivalent) fixed with C.P. brass screws complete in all respects. |
| 179 | Providing and fixing Grab Bar Jaquar Model No. AKP-35701P or approved equivalent,Including cutting and making good the walls wherever required |
| 180 | Providing and fixing 150 litre/ hr. cooling and storage capacity,fully stainless steel electric storage type water cooler ( Blue Star model No. SDLX 15150 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect. |
| 181 | Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 50 litres / hour designed at a minimum Flux at inlet complete as required. |
| 182 | Providing and Fixing of shower set comprising of one no. CP brass wall mixer Jaquar model-FUS-29273UPR, C.P. one no. Brass OH shower head & one no. Shower Arm Make Jaquar Model No.OHS-1799 + SHA-483 or approved equivalent. |
| 183 | Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). |
| 184 | Capacity 25 Litres Model 25 GV |
| 185 | Providing and fixing fully automatic Hand dryer Euronics Model-EH 26 NW or equvalant ,including all fittings complete in all respect. |
| 186 | Providing and fixing Air Purifier Euronics Model-EA 24 or equvalant ,including all fittings complete in all respect. |
| 187 | Soil, Waste, Vent & Rain Water Pipes |
| 188 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : form work. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 189 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 190 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 191 | Providing and fixing SWR uPVC pipes (Type-B) confirming to IS 13592 : 1992 complete with all fittingse.g. plain or door bends, junctions, cowls, offsets, access pieces etc. jointing with rubber rings and solvent cement including fixing the pipes on wall face with galvanized iron holder bat clamps or suspended below ceiling with galvanized iron hangers/supports and fasteners all as approved by the engineer in charge including Cutting holes inwalls, floors excavation, refilling and disposal of surplus earth wherever required and making good . The rates shall be inclusive of painting of all supports and clamps with a coat of red oxide primer and two or morecoats of synthetic enamel paint of approved colour and Qualitytogivean even shade including surface preparation.(Sample ofholder bat clamps,hangers / supports to be approved by the Engineer-in-Charge.) |
| 192 | 110 mm OD |
| 193 | Providing and fixinguPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwedadoptors jointing with solvent cement joint as per manufacturers\" recommendations. [for Waste Connections Pipes] |
| 194 | 40 mm OD |
| 195 | 63 mm OD |
| 196 | Providing and fixing uPVCP-Trap with extension piece including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 hand stone ballast 20 MM nominal size) the inlet from floor level to trap rim to be grouted and cemented neat manner including cutting and making good the floor & wall wherever requiredcomplete in all respects |
| 197 | 110 mm inlet and 110 mm outlet. |
| 198 | Providing and fixing in position 110x63 mm OD uPVC reducing elbow including fix to floor with cement mortar. |
| 199 | Providing and fixing 110 mm OD uPVC inlet fitting/ Extension Piece with 2 or 3 inletsof 40 to 63 mm OD, fixed to uPVC trap with solvent cement joint and set in cement concrete as per drawing complete. |
| 200 | Providing and fixinguPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwedadoptors jointing with solvent cement joint as per manufacturers\" recommendations. [for Rain Water Pipes] |
| 201 | 160 mm OD |
| 202 | 110 mm OD |
| 203 | Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. |
| 204 | For 100 mm dia Pipe |
| 205 | For 160 mm OD Pipe |
| 206 | Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar. |
| 207 | Water Supply System |
| 208 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 209 | Concealed work including cutting chases and making good the walls etc. |
| 210 | 20 mm nominal outer dia .Pipes. |
| 211 | 25 mm nominal outer dia .Pipes. |
| 212 | 32 mm nominal outer dia .Pipes. |
| 213 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 214 | Internal work - Exposed on wall |
| 215 | 20 mm dia nominal bore |
| 216 | 25 mm dia nominal bore |
| 217 | 32 mm dia nominal bore |
| 218 | 40 mm dia nominal bore |
| 219 | 50 mm dia nominal bore |
| 220 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : |
| 221 | 20 mm dia nominal bore |
| 222 | 25 mm dia nominal bore |
| 223 | 32 mm dia nominal bore |
| 224 | 40 mm dia nominal bore |
| 225 | 50 mm dia nominal bore |
| 226 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
| 227 | 20 mm dia nominal bore |
| 228 | 25 mm dia nominal bore |
| 229 | 32 mm dia nominal bore |
| 230 | 40 mm dia nominal bore |
| 231 | 50 mm dia nominal bore |
| 232 | Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. |
| 233 | 20 mm nominal bore |
| 234 | 25 mm nominal bore |
| 235 | 32 mm nominal bore |
| 236 | 50 mm nominal bore |
| 237 | Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. |
| 238 | 6 mm thick (Concealed Pipes) |
| 239 | For 20 mm dia Pipe |
| 240 | Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia. |
| 241 | Providing and fixing threaded end brass digital water meter complete in all respect. |
| 242 | 25 mm dia. |
| 243 | 32 mm dia. |
| 244 | Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves,necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. |
| 245 | 32 mm dia. |
| 246 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 247 | Sewerage System |
| 248 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 249 | All kinds of soil |
| 250 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. |
| 251 | All kinds of soil |
| 252 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia. |
| 253 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 254 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : For Bed Concrete of Sewer Lines. |
| 255 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 256 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 257 | 180x150 mm size P type |
| 258 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 259 | Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. |
| 260 | 150 mm dia. |
| 261 | 200 mm dia. |
| 262 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 263 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 264 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 265 | Extra for depth for manholes : |
| 266 | Size 90x80 cm |
| 267 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 268 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 269 | Fire Fighting System |
| 270 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. |
| 271 | Capacity 4.5 Kg. |
| 272 | Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. |
| 273 | Capacity 6.0 Kg. |
| 274 | CONDUIT COST |
| 275 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 276 | 20 mm |
| 277 | 25 mm |
| 278 | 32 mm |
| 279 | FOR TV & TELEPHONE |
| 280 | Supply and fixing of following sizes of 25mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 281 | Supply and fixing of following sizes of 32mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail