| 1 | Supply & fixingAPFC controller Relay 8 step, 415V complete all as directed by Engineer-in-charge. |
| 2 | Supply & fixing5 KVAR Heavy Duty Capacitor complete all as directed by Engineer-in-charge. |
| 3 | Supply & fixing10 KVAR Heavy Duty Capacitor complete all as directed by Engineer-in-charge. |
| 4 | Supply & fixing15 KVAR Heavy Duty Capacitor complete all as directed by Engineer-in-charge. |
| 5 | Supply & fixing 5 KVAR Detuned Copper 7% Reactors, 440V complete all as directed by Engineer-in-charge. |
| 6 | Supply & fixing 10 KVAR Detuned Copper 7% Reactors, 440V complete all as directed by Engineer-in-charge. |
| 7 | Supply & fixing 15 KVAR Detuned Copper 7% Reactors, 440V complete all as directed by Engineer-in-charge. |
| 8 | Supply & fixing Current Transformer 5A complete all as directed by Engineer-in-charge. |
| 9 | Supply & fixing in timerof capacity 100 Amp to 180 Amp, HGST 150 complete all as directed by Engineer-in-charge. Make : Havells model No IHHR53C8 or equivalent make of L&T/Schnier/Legrand. |
| 10 | Repairing cum servicing of Automatic Servo Voltage Controller including changing of control card, changing of minor spares etc. complete all as directed by Engineer-in-charge. |
| 11 | Supply and fixing Automatic Digital Control Card complete all as directed by Engineer-in-charge. |
| 12 | Taking up existing old/unserviceable/burnt underground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable of following size complete all as specified and as directed.Note: (i) Excavation/earth work shall be measured and paid separately under relevant items.(ii) Retrieved serviceable bricks from site be properly stacked and reused as protection to UG cable and shall be measured and paid separately under relevant items.(iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separately under relevant items.(a) 300 Sqmm 3.5 core |
| 13 | (b) 240 Sqmm 3.5 core |
| 14 | (c) 185 sq mm 3.5 core |
| 15 | (d) 120 sqmm 3.5 core |
| 16 | (e) 95 sqmm 3.5 core |
| 17 | (f) 70 sqmm 3.5 core |
| 18 | (g) 50 sqmm 3.5 core |
| 19 | (h) 35 sqmm 3.5 core |
| 20 | (j) 25 sqmm 4 core |
| 21 | (k) 16 sqmm 4 core |
| 22 | Supply, laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100v grade, with aluminium conductor of following size for replacement of unserviceable portion of cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel /joints etc., all as per site requirement including testing complete all as specified and as directed by Engr-in-charge. Make :-POLYCAB/NICCO/PLAZA/Havells Note:(i) Rates includes supply and fix necessary glands, lugs, etc., (ii) Excavation/ Earth work shall be measured and paid separately under relevant items.(iii) Cable straight through joints if any as per site requirement shall be measured and paid separately under relevant item of schedule.(a) 300 Sqmm 3.5 core |
| 23 | (b) 240 Sqmm 3.5 core |
| 24 | (c) 185 sq mm 3.5 core |
| 25 | (d) 120 sqmm 3.5 core |
| 26 | (e) 95 sqmm 3.5 core |
| 27 | (f) 70 sqmm 3.5 core |
| 28 | (g) 50 sqmm 3.5 core |
| 29 | (h) 35 sqmm 3.5 core |
| 30 | (j) 25 sqmm 4 core |
| 31 | (k) 16 sqmm 4 core |
| 32 | Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for taking up/ laying cable etc., and getting out for soft / loose soil complete all as specified and as directed. |
| 33 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cms for soft/loose soil complete all as specified and as directed. |
| 34 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed. |
| 35 | M&L for filling approved fine river sand in trenches as cablecushionto the full width of excavated trench, under and over cable complete all as specified directed.(Note : Punned thickness of sand shall be measured) |
| 36 | Supply and laying well burnt Bricks, locally available best quality (sub class \"B\" bricks) laid in trenches perpendicularto U/G cable for cable protection complete all as specified. |
| 37 | Supply & fixing Pressure booster pump power driven centrifugal pump multiboost KHM0403 1.0 HP (24 Ltrs) +1.0 HP (24 Ltr)0.75 KW/1 HP stage 3, 22 kgcomplete as per fitting and testing etc. all as directed by Engineer-in-charge. Make : KSB or equivalent. |
| 38 | Supply & fixing First Aid Kit box made of plywood 12mm incl painting & locking arrangement (Size 360mm x 150mm x 80mm) containing following items:-(a) Dettol bottle 100 ml 02 Nos(b) Antiseptic Ointment100 mg(c) Crocin tablets 01 strips (Containing 10 tablets each)(d) Hydrogen peroxide 50 ml 01 bottle(e) Cotton small rolls02 Nos (f)Move tube 01 No (g) Betadine Tube 100 mg(h) Cotton strip small roll 04 Nos |
| 39 | Painting ofservo voltage stabilizer indoor/ outdoor on plinth/pole in workshop with one coat of synthetic enamel paint Not with compressor spray gun after removing all dust, rust, Paint shall confirmed to IS-2032 and wiring SM & MES with letter not less than 50 mm with white paint on location capacity of 75 KVA to 500 KVA as specified and directed by Engr-in-Charge. |
| 40 | Cutting of worn out aluminium cable terminal lugs from the LT cable, crimping of new aluminium cable core, lugs suitable size and fixing with stabilizer, terminal stud including cutting/dressing of cable, excavation surface after providing redressing of excavated surface after providing sand cushioning and brick protection as specified and directed by Engr-in-Charge. |
| 41 | Dehydration and filtration of existingtransformer oil of servo voltage stabilizer capacity ranging from 50 KVA to 400 KVA distribution uptoon site at different locationswithout disturbing the power supply system withfiltration machine and heating system in orderto achieve Di-electric strength of oil 45KV minimum at 2.5 mm gap complete all as specified and as directed.Note :- Contractor shall use stand by DG set for dehydrationwhere alternate power is not available. |
| 42 | Supply &filling up ofservo voltage stabilizer with transformer oil conforming to IS -335 of 1993 as in topping up/ replacementup to desired level of transformer oil servo voltage stabilizer capacity complete all as specified and as directed. [Note: Dielectric strength of oil forshould not be less than 46 KV at 2.5 mm gap complete all as specified and directed.](Make : GULF/POWER OIL/SERVO or equivalent as approved by GE) |
| 43 | Supply & fixing Huma fountains and pools 12 W ABS plastic LED underwater waterproof wall mounted night swimming pool lights (White colour)LED waterproof swimming pool light all as directed by Engineer-in-charge. |
| 44 | S&F Danger notice plate of 1.6mm thick size LT 25 x 20 cm of mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved of size including taking down rusted danger plates complete all as specified and as directed |
| 45 | Supply & fixing in air circuit breaker of capacity 630 Amp, 4 pole and 50 KA fixed type complete all as directed by Engineer-in-charge. Make : Havells model No IHAFE11060 or equivalent make of L&T/Schnier/Legrand. |
| 46 | Supply & fixing in change over switch open type of capacity 630 Amp, 4 Pole complete all as directed by Engineer-in-charge. Make : L&T model No CO46300OOOO or equivalent make of Havells/Schnier/Legrand. |
| 47 | Supply & fixing in MCCB of capacity 320/300 Amp, 4 Pole and 45 KA complete all as directed by Engineer-in-charge. Make : Havells model No IHDA9UBF0300 or equivalent make of L&T/Schnier/Legrand. |
| 48 | Supply & fixing in MCCB of capacity 250 Amp, 4 Pole and 38 KA complete all as directed by Engineer-in-charge. Make : Havells model No IHD2HTBF0250 or equivalent make of L&T/Schnier/Legrand. |
| 49 | Supply & fixing in MCCB of capacity 63 Amp, 4 Pole and 38 KA complete all as directed by Engineer-in-charge. Make : Havells model No IHD6TBF0063 or equivalent make of L&T/Schnier/Legrand. |
| 50 | Supply & fixing in magnetic contactor 3 pole power contactors of capacity 150 Amp to 210 Amp, in build auxilliary contacts HGS 150 complete all as directed by Engineer-in-charge. Make : Havells model No IHPHA150500 or equivalent make of L&T/Schnier/Legrand. |
| 51 | Supply & fixing in thermal over load relay (auto/Manual reset) -HGST Series of capacity 90 Amp to 150 Amp, HGST 150 complete all as directed by Engineer-in-charge. Make : Havells model No IHHR53C8 or equivalent make of L&T/Schnier/Legrand. |
| 52 | Supply & fixing in SPP complete all as directed by Engineer-in-charge. Make : Havells model No ISCELXL00063 or equivalent make of L&T/Schnier/Legrand. |
| 53 | Supply & fixing Rotary gear pump completed with single phase 230 v AC Electric motor, mounted on common base frame Pump model HGP-050 Size suction delivery 1/2\"x1/2\" capacity 20 LPM speed 1440 RPM pressure 2 Kg/Cm2 motor 0.5 HP. Make : ROTODYNE/CIVCON Rotary gear pump, KSP or equivalent. |
| 54 | Supply & fixing Rotary gear pump completed with single phase 230 v AC Electric motor, mounted on common base frame Pump model HGP-070 Size suction delivery 3/4\"x3/4\" capacity 30 LPM speed 1440 RPM pressure 4 Kg/Cm2 motor 1.0 HP. Make : ROTODYNE/CIVCON Rotary gear pump, KSP or equivalent. |
| 55 | Material and labour for Glow sign board of area 36 sqftmade of angle iron frame work as per site requirementwith front side covered with 4mm ACP (LED binding design) thick acrylic sheet for writing letters in appropriate font size and backside coveredwith 0.63 mm thick G Isheet, duly prewired and including 8 Nos Tube light set (LED type) of 20 wattsinside the board incl connection electrically and fixed to the ironframe inclnecessary fixing arrangement such as angle iron, flat iron and Channels complete all as specified anddirected by Engr-in Charge. Note:- Data to be written on Glow Sign Board will be as directed by Engr-in-Charge and Measurement of Angle iron, Channels,Flat iron and other iron work will be measured and paid under respective item. |
| 56 | M & L for Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick, buried directly in ground to a depth not less than 2.25 metres below ground level with top edge of the plate not less than 1.5 metres below normal ground level and connected to copper strips 20 x 3 mm by means of copper, nuts, check nuts and washers and protected by 40mm diaGI pipe light grade and watering pipe of 20 mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed.Notes : The unit rate includes for protection pipe and Copper strip from top of earth plate up to 7.00 meter above ground level. |
| 57 | S & F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles duly fixed over epoxy electrical insulators or any other indicated situation for loop earthing etc as required with 32 x 6 mm copper strip duly brazed complete all as specified and directed. |
| 58 | Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., and segregating aside for serviceable for re-use complete all as specified and as directed. |
| 59 | M&L in replacementfor Angle iron bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified. |
| 60 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete. |
| 61 | M&L Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete. |
| 62 | M&L Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete. |
| 63 | M&L for earthing complete with galvanised steel earth plate electrodesize 600x600x6.0mm thick buried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.NOTES : The unit rate includes for protection pipe and GI wire dia from top of earth plate up to 7.00 meter above ground level. |
| 64 | Excavationintrenchesnotexceeding1.5 M wideandnotexceeding1.5 Mindepthandgettingoutin soft/loosesoilorhard/densesoilfortakingup orlaying ofcableallasspecifiedanddirected. |
| 65 | Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete all as specified. |
| 66 | Removing excavatedmaterialnotexceeding50 Manddepositingwheredirectedatalevelnotexceeding 1.5 Mabovestartingpoint complete all as specified. |
| 67 | S&F Epoxy electrical insulator(heavy duty) for fixing of Copper/Aluminium Strip/GI wirecomplete all as specified and directed. |
| 68 | S&F in repair air termination, single pointed copper rod, 12 mm dia and 300 mm long, fixed on GI pipeswith earthing strips for earth coductivity to ground complete all as specified and directed.(NOTE: GI pipe & earthing strip shall be measured and paid seperately) |
| 69 | S&F in repair air termination, single pointed copper rod, 12 mm dia and 600 mm long, fixed on GI pipeswith earthing strips for earth coductivity to ground complete all as specified and directed.(NOTE: GI pipe & earthing strip shall be measured and paid seperately) |
| 70 | Supply, stretching and fixing in position GI earth wire 4.00 mm diaduly fixed properly complete all as specified and directed. |
| 71 | S& F in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles duly fixed over epoxy electrical insulatorsor any other indicatedsituation for loop earthing etc as required with 20 x 3mm copper strip duly brazedcomplete all as specified and directed. |
| 72 | M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 32 x 6 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both waysall as shown in electrical plate No. 5 of SSR Part-I all as specified and directed. NOTES : The unit rate includes for protection pipe and GI stripfrom top of earth plate up to 7.00 meter above ground level. |
| 73 | Supply and fixing of GI strip 32 x 6 mmfixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode duly brazed over epoxy electrical insulators complete all as specified and directed |
| 74 | Supply and Fix in repalcement of Lightning arresters expulsion type complete with all fittings, transmission class, dischargecapacity 65 kilo amp Suitable for 11000 Volts complete all as specified and directed. |
| 75 | Supply and Fix Aluminium strip 25 x 3 mm with saddles and fixingscrews etc. for roof conductors and down conductors above ground and over roof over porcelein insulators complete all as specified and directed |
| 76 | S & F in replacementTest point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw in a test point boxcomplete all as specified and as directed. |
| 77 | S&F in replacementGI Pipe of 32 mm Dia, ISI Marked , light grade to cover the earth strip Complete all as Specified and directed |
| 78 | S&F in replacementGI Pipe of 40 mm Dia, ISI Marked , light grade to cover the earth strip (32 mm x 6mm) Complete all as Specified and directed |
| 79 | Supply and Fix in replacement ThermoplasticCable Junction Boxes IP66/67 \"weather proof\" , for outdoor installation without mounting plate withTransparent Lid ofSize 217 X 253 X 115 mm for mounting of Test Point and including Necessary civil works and complete all as specified and directed by Engr-in-Charge. Make Cat No. KG9003of Hensel or equivalentin sintex |
| 80 | Material and labour for making ofPCC Chamber coverin PCC (1.3:6) type C1 (using 20 mm graded stone aggregate) with pit cover of 300 mm x 300 mm with RCC (1 :3:6)alongwith provision ofhandle with 10 mm GI bar and funnel for water pipe complete including dismantling old PCC Chamber completeall as specified and directed |
| 81 | Material and labour for adding salt upto 35 Kgs duly mixedwater to make the existing earthing serviceable and to get the desired earth values complete all as specified and directed |
| 82 | Dismantling Concrete any type in ground floors and pavings n exc 15 cm thickness(below or above ground level) complete all as specified and diected |
| 83 | M & L for cement concrete type B0, 1:2:4with 12.5mm graded aggregate for foundation to poles as specified and directed. |