| 1 | SCHEDULE \"A\" PART-I: B/R WORKS |
| 2 | Site clearanceall as directed. |
| 3 | Surface dressing n. Exc 15 cm deep in hard/dense soil all as directed. |
| 4 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.,and disposal of unserviceable materials, debris and rubbish as directed by the Engineer in Charge. |
| 5 | M&L walling of random rubble , uncoursed , well bonded , bedded and solidly heared built in cm 1:6 all as specified and directed. |
| 6 | Extra over stone walling of 40 mm thick for hammer dressing to face stone and dressing of face beds and joints as specified of random rubble walling uncoursed or brought upto course all as specified and dircted. |
| 7 | Racking out joints / pointing torandom rubble or polygonal rubble uncoursed or brought upto courses in cement mortar all as specified and directed. |
| 8 | Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface and getting out in hard/dense soil. |
| 9 | Plain cement concrete type D2, 1:4 :8 (40mm graded stone aggregate) in foundations, fillings and mass concrete. |
| 10 | Plain cement concrete type D2, 1:2 :4 (40mm graded stone aggregate) in foundations, fillings and mass concrete. |
| 11 | Providing PrecastRCC (1:2:4) type B1 using (20 mm graded aggregate ) in precast post , fencing post, straining or terminal post , struts etc for fencingaverage sectional arean exc 250 sq.cm with or without chamferd angles and flat , splayed and rounded or mitred tops all as specified and directed. columns, pillars , piers, post and struts etc complete all as specified and directed. |
| 12 | M & L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips. |
| 13 | M & L for form work to sides of pillars, posts, struts, piers, columns and stanchions square, or rectangular with rough finished surfaces of concrete complete all as specified 7 directed. |
| 14 | S& F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as directed. |
| 15 | M&L Preparing newly plastered or unplastered wall surfaces and applyingtwo coats ofcement base paint over one coat of white wash complete all as specified and as directed. |
| 16 | M & L for Plain cement concrete type B0, (1:2:4) (using 12.5 mm graded stone aggregate) cast in situ in cills and other similar bands, plinth courses, parapets, copings, hold fast, bed plates and the like including use and waste of form work, weathering, slightly rounded or chamfered angles and throating as required. |
| 17 | SCHEDULE \"A\" PART-II: E/M WORKS |
| 18 | S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - )2.5% and of capacity3.0 KVA complete all as specified and directed. |
| 19 | S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - )2.5% and of capacity4.0 KVA complete all as specified and directed. |
| 20 | Supply, install, testing and commissioning of Hi wall Split Air conditioner, BEE 5 star rated, with indoor / outdoor units with cordless remote control unit in built air ioniser and plasma filter for better indoor air quality with latest inverter technology having eco friendly refrigerent gas, copper condenser coil, EER 3.2 of capacity 1.5 TRcomplete all as specified and directed .[Make: BLUE STAR/ HITACHI/ DAIKIN / CARRIER / LG](Note :-1. The rate consider deemed to include of bracket for fixing of indoor and outdoor unit in wall of any height as directed by Engr-in charge. 2. The copper tube of suitable size and length (for each ACs), Drain pipe, cables with plug top are included in quoted rate. 3. Provision of passing of indoor/outdoor pipe from wall / core cutting in any type of wall are included with quoted rate.) |
| 21 | S & F Modular Single pole and neutral enclosure with a two pin and earth plug and socket complete with one SPN MCB of 20A rating complete all as specified and as directed. |
| 22 | M&L for sub main wiring withtwo run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt,and onerun of copper earth wire 4.0Sq mm drawn through PVC concealed conduict of 25 mm dia,complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire along with PVC concealed conduictshall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 23 | Supply and fixingof MCB 40 to 63Amp, 240 Volt, SPN, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 24 | Supply and fixingof MCB 6 to 32Amp, 240 Volt, SP, breaking capacity 10 KA \"C\" series,complete all as specified |
| 25 | Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to thewall),SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB\"s complete all as specified. |
| 26 | Supply, install, testing and commissioning of Vertical / Tower type 2.5 TR Air conditioner complete set including suitable stand for out door unit, drain system with 20mm dia PVC conduit upto ground level including refrigerant gas charging , copper tubing , remote and remote stand and making good disturbed surface to mach with original status complete all as specified and directed |
| 27 | Supply, install, testing and commissioning of Hi wall split type 1.5 TR Air conditioner complete set including suitable stand for out door unit, drain system with 20mm dia PVC conduit upto ground level including refrigerant gas charging , copper tubing , remote and remote stand and making good disturbed surface to mach with original status complete all as specified and directed |
| 28 | S & F voltage stablizer for automatic operation, sigle phase naturally air cooled indoor type & designed for input varitation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ( + / - )2.5% and of capacity5.0 KVA complete all as specified and directed. |
| 29 | M & L for sub main wiring with four run of 10.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 10.0 Sq mm drawn through PVC concealed conduit of 25 mm die, complete all as specified and specified. Note: Copper conductor 4 run and one run of copper earth wire along with PVC concealed conduict shall be measured as one length & Cutting of chases/walls and making good the disturbed surface are included in the rate. |
| 30 | Supply and fixing of Factory made sheet metal enclosure for VTPN DB 4 way (Fixed flush to the wall), with provision of MCCB 100 Amps,16 KA, 415 volt, IP-43 protection with 200 Amp rated bus bar and 6.0 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB\"s , complete all as specified. |
| 31 | Supply and fixing of Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), TPN, 415 volt,4 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s , complete all as specified. |
| 32 | Supply and fixing ofMCB 40-63Amp, 415 Volt, TP, breaking capacity 10 KA \"C\" series, , complete all as specified |
| 33 | S & F Modular triple pole and neutral enclosure with a three pin and earth plug and socket complete with one TPN MCB of 32A rating complete all as specified and as directed. |
| 34 | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and as directed. |
| 35 | M&L Earthing complete with GI plate electrode 600x600x6mm thick, buried directly and preferably Each vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with galvanised earth lead wire 4.0mm dia as earth lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No 5, connected to earthing with DBs all as specified and filling up with adequate Charcoal and Rock salt, including earth work and excavation in any type of soil, PCC 1:3:6 type Cl chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion including taking down old |