Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #47175093

Tender For Purchase Of Various Apparatus/Instruments Required For Department Of Chemistry, Chaudhary Ranbir Singh University, Jind

Issued by Boards / Undertakings / PSU · jind, Haryana
Tender Value
12 Lakhs
Estimated cost
Bid Submission
01 Feb 2025
0 days left
EMD
24000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jind → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

PURCHASE OF VARIOUS APPARATUS/INSTRUMENTS REQUIRED FOR DEPARTMENT OF CHEMISTRY, CHAUDHARY RANBIR SINGH UNIVERSITY, JIND- 1 Stirrer The stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. The stirring speed should be 50-1500 rpm or better. The stirrer should be operational up to a temperature range of 300oC with an accuracy of ±1.0oC and IP 42 protection class. The input power should be 600 W or above. The stirrer should be supplied with Hemispheric Bowl (100 mL= 1 no; 250 mL= 1 No) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks. 2 Electronic balance The electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. The system should have automatic internal calibration with touch screen display. The system should have internal database capacity of 2500 or more with multiuser password protection feature. 3 Vacuum pumpThe pump should be operational at a maximum power of 65 W or more with a max. vaccum of 99 mbar or more. The pump should be fitted with Vacuum and filter cartridge. 4 Hot air ovenThe inner chamber should be made of stainless steel and the outer chamber should be M.S powder Coated. The maximum capacity of the oven should be 100 mL or more. The operational temperature should be between ambient to 250 oC or more with a temperature accuracy of ±1o C. PID based digital Temperature control. 5 Double distillation unitThe unit should be pyrogen free with a distillation water output capacity of 1.5 L/h. The minimum cooling water requirement should be 1lt/min. Auto-power cut facility in case of halted supply of water. 6 Circulating oil bathThe oil bath should be made up of stainless steel with 4 digit 7 segment LED display for temperature and time. The bath should have S.S perforated tray for holding flasks. The bath should have a capacity to accommodate flask of 1L. The working temperature range should be +5 to 240 oC (0.1 oC increment) with a temperature stability of ±1oC. 7 Water bathThe water bath should have a capacity of 20 L within built water level sensor. The bath should be made up of stainless steel and supplied with 8 concentric rings. The bath should have digital temperature control with PT100 sensor. The system should have stirring capability with PTFE magnetic bars. 8 pH conductivity meter Operational between a pH range of -2 to 16.00 with a resolution of 0.01 pH and an accuracy of 0.02 pH. 5 points calibration. The EC range should be in between 0.00 to 29.99 μS/cm 9 UV cabinet Operational at two UV wavelengths (254 and 365 nm). The cabinet should also be equipped with one visible light. The external body should be coated with MS powder/epoxy. 10 Flame PhotometerApplication: The flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. These metals include Na+, K+, Ca2+, Ba2+ and Li2+.Specification RequirementMeasuring Range Na+: 0 to 99.9 ppm K+:0 to 99.9 ppm Ca2+ :0-99.9 ppmLi2+: 0 to 99.99 ppmSensitivity Na+= 0.1 ppmK+ = 0.1 ppmSpecificity Less than 0.5% interference when concentrations are equal to test sample concentrationsGas Control-Adjustable with knobsIgnition System-Auto Ignition SystemFlame Failure-Auto detectionGas Cut off-AutomaticReproducibility-Less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm Na set as maximum standardLinearity-Less than 1%Display LED, 12.5 mm (1/2)Fuel supply-High-grade propane/butane mixture regulated at approximately30 psiAir supply-6 L/min at 12 psi; oil and moisture freeRecorder-output 0.05 to 5 V (switchable)Operating manuals, service manuals, other manuals Should provide• User, technical and maintenance manuals in English language• List of equipment and procedures required for local calibration and routine maintenance• Service and operation manuals to be provided advanced maintenance tasks documentation, if any.

BOQ

Name of Work: PURCHASE OF VARIOUS APPARATUS/INSTRUMENTS REQUIRED FOR DEPARTMENT OF CHEMISTRY, CHAUDHARY RANBIR SINGH UNIVERSITY, JIND
Sl. No. Item Description
1Stirrer The stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. The stirring speed should be 50-1500 rpm or better. The stirrer should be operational up to a temperature range of 300oC with an accuracy of ±1.0oC and IP 42 protection class. The input power should be 600 W or above. The stirrer should be supplied with Hemispheric Bowl (100 mL= 1 no; 250 mL= 1 No) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks.
2Electronic balance The electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. The system should have automatic internal calibration with touch screen display. The system should have internal database capacity of 2500 or more with multiuser password protection feature.
3Vacuum pumpThe pump should be operational at a maximum power of 65 W or more with a max. vaccum of 99 mbar or more. The pump should be fitted with Vacuum and filter cartridge.
4Hot air ovenThe inner chamber should be made of stainless steel and the outer chamber should be M.S powder Coated. The maximum capacity of the oven should be 100 mL or more. The operational temperature should be between ambient to 250 oC or more with a temperature accuracy of ±1o C. PID based digital Temperature control.
5Double distillation unitThe unit should be pyrogen free with a distillation water output capacity of 1.5 L/h. The minimum cooling water requirement should be 1lt/min. Auto-power cut facility in case of halted supply of water.
6Circulating oil bathThe oil bath should be made up of stainless steel with 4 digit 7 segment LED display for temperature and time. The bath should have S.S perforated tray for holding flasks. The bath should have a capacity to accommodate flask of 1L. The working temperature range should be +5 to 240 oC (0.1 oC increment) with a temperature stability of ±1oC.
7Water bathThe water bath should have a capacity of 20 L within built water level sensor. The bath should be made up of stainless steel and supplied with 8 concentric rings. The bath should have digital temperature control with PT100 sensor. The system should have stirring capability with PTFE magnetic bars.
8pH conductivity meter Operational between a pH range of -2 to 16.00 with a resolution of 0.01 pH and an accuracy of 0.02 pH. 5 points calibration. The EC range should be in between 0.00 to 29.99 μS/cm
9UV cabinet Operational at two UV wavelengths (254 and 365 nm). The cabinet should also be equipped with one visible light. The external body should be coated with MS powder/epoxy.
10Flame PhotometerApplication: The flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. These metals include Na+, K+, Ca2+, Ba2+ and Li2+.Specification RequirementMeasuring Range Na+: 0 to 99.9 ppm K+:0 to 99.9 ppm Ca2+ :0-99.9 ppmLi2+: 0 to 99.99 ppmSensitivity Na+= 0.1 ppmK+ = 0.1 ppmSpecificity Less than 0.5% interference when concentrations are equal to test sample concentrationsGas Control-Adjustable with knobsIgnition System-Auto Ignition SystemFlame Failure-Auto detectionGas Cut off-AutomaticReproducibility-Less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm Na set as maximum standardLinearity-Less than 1%Display LED, 12.5 mm (1/2\")Fuel supply-High-grade propane/butane mixture regulated at approximately30 psiAir supply-6 L/min at 12 psi; oil and moisture freeRecorder-output 0.05 to 5 V (switchable)Operating manuals, service manuals, other manuals Should provide• User, technical and maintenance manuals in English language• List of equipment and procedures required for local calibration and routine maintenance• Service and operation manuals to be provided advanced maintenance tasks documentation, if any.

AI Tender Summary

OUR REF NO 47175093
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 12 Lakhs
LAST DATE 01-02-2025
Authority
Authority Name Chaudhary Ranbir Singh University
Work Description PURCHASE OF VARIOUS APPARATUS/INSTRUMENTS REQUIRED FOR DEPARTMENT OF CHEMISTRY, CHAUDHARY RANBIR SINGH UNIVERSITY, JIND- 1 Stirrer The stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. The stirring speed should be 50-1500 rpm or better. The stirrer should be operational up to a temperature range of 300oC with an accuracy of ±1.0oC and IP 42 protection class. The input power should be 600 W or above. The stirrer should be supplied with Hemispheric Bowl (100 mL= 1 no; 250 mL= 1 No) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks. 2 Electronic balance The electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. The system should have automatic internal calibration with touch screen display. The system should have internal database capacity of 2500 or more with multiuser password protection feature. 3 Vacuum pumpThe pump should be operational at a maximum power of 65 W or more with a max. vaccum of 99 mbar or more. The pump should be fitted with Vacuum and filter cartridge. 4 Hot air ovenThe inner chamber should be made of stainless steel and the outer chamber should be M.S powder Coated. The maximum capacity of the oven should be 100 mL or more. The operational temperature should be between ambient to 250 oC or more with a temperature accuracy of ±1o C. PID based digital Temperature control. 5 Double distillation unitThe unit should be pyrogen free with a distillation water output capacity of 1.5 L/h. The minimum cooling water requirement should be 1lt/min. Auto-power cut facility in case of halted supply of water. 6 Circulating oil bathThe oil bath should be made up of stainless steel with 4 digit 7 segment LED display for temperature and time. The bath should have S.S perforated tray for holding flasks. The bath should have a capacity to accommodate flask of 1L. The working temperature range should be +5 to 240 oC (0.1 oC increment) with a temperature stability of ±1oC. 7 Water bathThe water bath should have a capacity of 20 L within built water level sensor. The bath should be made up of stainless steel and supplied with 8 concentric rings. The bath should have digital temperature control with PT100 sensor. The system should have stirring capability with PTFE magnetic bars. 8 pH conductivity meter Operational between a pH range of -2 to 16.00 with a resolution of 0.01 pH and an accuracy of 0.02 pH. 5 points calibration. The EC range should be in between 0.00 to 29.99 μS/cm 9 UV cabinet Operational at two UV wavelengths (254 and 365 nm). The cabinet should also be equipped with one visible light. The external body should be coated with MS powder/epoxy. 10 Flame PhotometerApplication: The flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. These metals include Na+, K+, Ca2+, Ba2+ and Li2+.Specification RequirementMeasuring Range Na+: 0 to 99.9 ppm K+:0 to 99.9 ppm Ca2+ :0-99.9 ppmLi2+: 0 to 99.99 ppmSensitivity Na+= 0.1 ppmK+ = 0.1 ppmSpecificity Less than 0.5% interference when concentrations are equal to test sample concentrationsGas Control-Adjustable with knobsIgnition System-Auto Ignition SystemFlame Failure-Auto detectionGas Cut off-AutomaticReproducibility-Less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm Na set as maximum standardLinearity-Less than 1%Display LED, 12.5 mm (1/2)Fuel supply-High-grade propane/butane mixture regulated at approximately30 psiAir supply-6 L/min at 12 psi; oil and moisture freeRecorder-output 0.05 to 5 V (switchable)Operating manuals, service manuals, other manuals Should provide• User, technical and maintenance manuals in English language• List of equipment and procedures required for local calibration and routine maintenance• Service and operation manuals to be provided advanced maintenance tasks documentation, if any.
Basic Detail
Tender No Chemistry Equipments
Bidding Type Tender
Location
City jind
State Haryana
Key Dates
Publish Date 11 Jan 2025
Submission Date 01 Feb 2025
Open Date 03 Feb 2025
Finance
Tender Value 12 Lakhs
Tender Fee 5000
EMD 24000
Exemption Available
Document List
2d7b4f0e-d883-4063-b446-c9be4ce6de16.html
Tendernotice_1.pdf
BOQ_499680.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 11, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 01, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 03, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2d7b4f0e-d883-4063-b446-c9be4ce6de16.html

pdf

Tendernotice_1.pdf

xls

BOQ_499680.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender