Defence Government Departments Closing in 0 days TDR #47170842

Tender For Renovation Up Gradation Of Toilet Blocks Of Bsf Sr Sec School Under Bsf Academy Tekanpur Sh Providing Of Ei

Issued by Government Departments · tekanpur, Madhya Pradesh
Tender Value
10.45 Lakhs
Estimated cost
Bid Submission
18 Jan 2025
0 days left
EMD
20918
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tekanpur → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Renovation Up Gradation Of Toilet Blocks Of Bsf Sr Sec School Under Bsf Academy Tekanpur Sh Providing Of Ei

BOQ

Name of Work: Renovation/Upgradation of toilet blocks of BSF Sr. Sec School under BSF Academy Tekanpur (Sh: Providing of EI)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group B
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group -B
3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5Supplying and fixing of following sizes of medium class PVC conduit/Casing capping along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20/25MM
6Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.i) 5/6 amps switch
7Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.ii) 3 pin 5/6 amps socket outlet
8Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.TV antenna socket outlet
9Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.i) 75 mm X 75 mm X 60 mm deep
10Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.ii) 100 mm X 100 mm X 60 mm deep
11Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.iii) 150 mm X 75 mm X 60 mm deep
12Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.iv) 200 mm X 250 mm X 100 mm deep
13Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.v) 250 mm X 300 mm X 100 mm deep
14Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
15Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required..
16Supplying and fixing PVC batten/ angle holder including connections etc. as required...
17Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door
18Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
19Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole.
20Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole.
21Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amp)
22Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
23Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
24Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
25Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
26Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
27Supplying and laying of following size HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63mm dia (OD-63 mm & ID-51 mm nominal).
28Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 50 mm dia
29Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 80 mm dia
30Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C X 35 sq. mm (32mm)
31Providingand fixing of 63 MM size HDPE pipe ISI marked in the existing wall/floor , along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointingand making goods with plastering and painting etc.complete as required.
32Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of one number 4C X 25 Sq. mm 1.1 KV grade aluminum conductor armored cable(Havells/L&T/POLYCAB/KEI) on wall surface as required.(clamped with 1mm thick saddle)
33Providing and laying of one number 4C X 120 Sq. mm 1.1 KV grade aluminum conductor armored cable(Havells/L&T/POLYCAB/KEI), PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV following size in the existing RCC/ HUME/ METAL pipe as required.
34Supplying and fixing of Havells Make Four pole , sheet steel , Busbar Chamber , 63 amp,415 volts , on surface / recess, complete with Aluminum busbar ,earth terminal,paintedincluding earthing etc as site as required or other equilent Make - C & S /L&T/ABB/BCH
35Providing and fixing of full glow 4\" 18/20 Watt Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack Tubelighting fixtureceilling/Wall mounting,,complete with connection, testing etc. as reqd.Make Havells E-LITE LED PRIDE PLUS /Philips/Havells/wipro/bajaj/Ledvance
36Supplying, Installation, testing and commissioning of 10 W 6500 KMIRROR LIGHT , complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Make -Philips / CG/ LEDVANCE /Wipro/Orient)
37Supplying and fixing of 300 mm Sweep , 1400 RPM Turbo Force , double ball bearing HD, Exhaust Fan, Single phase, 240 volt with Louver/ Shutter of Bajaj/Havells/ CG/Usha/Khaitan make.
38Providing, Installation, testing and commissioning ofenergy saving,IP66, 50 watt flood light luminaire withmade up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses and electronic driver , directly on wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Make Havells Model Endura pearl Neo - LHEECNP7PB6J050 OR other equilent Make / Philips/Crompton /Syska/Orient/Wipro
39Supplying, installation, testing and commissioning of cubical type compartmentalized outdoor double door LT feeder pillar suitable for 415V, 3Phase, 4 wire 50Hz AC supply system. Panel should be factory fabricated in an approved factoryhaving modern fabrication and testing process . It shall have seven tank pretreatment process comprising of degreasing, rinsing ,de-rusting ,rinsing, phosphatizing ,rinsing and passivation followed by powder coat painting(shade: Siemens Grey RAL 7032) having a paint thickness of 60 microns . panel should be provided with suitable gasket to make it dust/vermin proof.Panel should be IP 54 protected .The Size of panel not less than 0.72 Cum, front surface area not less than 2.4sq. mtr made with 2 mm CRCA sheet and having detachable 3 mm thick CRCA gland plate, with 400 Amp capacity TPN aluminum bus bar base of insulated brackets or studs as per norms. The panel should be suitable to accommodate 04 nos MCCB of various rating, 04 Nos 4P MCB, LED indicators, Multifunction meter etc. as reqd,Suitable backlite sheet arrangement for insulation of MCCB and other switch gears and locking arrangement, hinges of the doors should be as required.The panel should be open able from two sides back & front sides should be fixed with hinges and lock as reqd, and having 300 mm height with 2 mm sheet on the base frame in all sides fixed on outer existing base frame with nut bolts. Inter link arrangement with suitable size bus bar should also be arranged accordingly to MCCB and other switch gears in all respect. (panel shall be made from CPRI approved manufacturers) The drawings will be final as per direction of Engineer-in-charge. the panel should be mounted on 50 mm x 50 mm x 6 mm GI Angle frame having length 0f 1200 mm (600 mm above ground level and 600 mm for foundation). Providing and laying in position cement concrete 1:3:6 (1 cement: 2 coarse sand: 6 graded stone aggregate 20 mm nominal size) in foundation of feeder pillar including form work etc. as required.The following panel mounting Switchgears etc complete as required.1) Panel dimensions :- 1500 mm x 1200 mm x 400 mm = 0.72 Cubic Meter2) 2)For Incoming:-3) a) 250Amp MCCB, , thermal & magnetic setting , Breaking CapacityIcs=100%Icu at 415 Volt AC, 50 Hz- 38 KA, 4 pole,including Spreaer Terminals MakeL&T ( D sine) /Hevells/Legrand cat No. 4202 79 Qty - 01 No.4)3) For Outgoing:-5) a) 160 Amp Amp MCCB, , adjustable thermal & fixed magnetic setting , Breaking CapacityIcu at 415 Volt AC, 50 Hz- 38 KA, 4 pole,including Spreder Terminals MakeL&T ( D sine) /Hevells/Legrand cat No. 4200 97 Qty - 01 No.6) b)100 AmpMCCB, , adjustable thermal & fixed magnetic setting , Breaking CapacityIcu at 415 Volt AC, 50 Hz- 38 KA, 4 pole,including Spreder Terminals MakeL&T ( D sine) /Hevells/Legrand cat No. 4200 95Qty - 02No7) (c) 63 Amp 4P C CurveMCB sort circuit Breaking capacity -10 kA (10 kA ISI marked as per IS/IEC 60898-1 2002)MakeL&T /Hevells/Legrand cat no. 4087 02 Qty - 04 No3) For Metering:-a) Three phase multifunction meter having following features, Accuracy Class 0.5,Input voltage measurement range 50-520 VAC,Aux supply 80-300 VAC/DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm,CT/PT site programmable, V, A, F, PF, kW, kVA, Old energy, On and Run hours, site selectable kWh/ kVAh, True PF or Displacement PF site selectable etc. as required. Make ABB/Siemens/Snieder/L&T cat No. WL440531OOOO b) Metering Current Transformers Busbar Type400/5A ratingsecondary current 5A, Primary current 400A,class 0.5, 15VA,Make: L&T/Rishabh/Hager/Matrix/Fuji electric c) LED indicators having colour Red, Yellow &Blue and operated on 240 Volt AC,Cat No-TTO, L&T Make - 01

AI Tender Summary

OUR REF NO 47170842
AUTHORITY Government Departments
TENDER VALUE 10.45 Lakhs
LAST DATE 18-01-2025
Authority
Authority Name Border Security Force
Work Description Renovation Up Gradation Of Toilet Blocks Of Bsf Sr Sec School Under Bsf Academy Tekanpur Sh Providing Of Ei
Basic Detail
Tender No 04/STC/NIT/ENGG/ELECT/2024-25
Bidding Type Tender
Location
City tekanpur
State Madhya Pradesh
Key Dates
Publish Date 12 Jan 2025
Submission Date 18 Jan 2025
Open Date 20 Jan 2025
Finance
Tender Value 10.45 Lakhs
Tender Fee Ref. Documents
EMD 20918
Exemption Available
Document List
fd136492-a59c-4935-8a3c-d59ad6a69785.html
Tendernotice_1.pdf
BOQ_887312.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 12, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 18, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 20, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

fd136492-a59c-4935-8a3c-d59ad6a69785.html

pdf

Tendernotice_1.pdf

xls

BOQ_887312.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders