Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #47163735

Tender For Re-Wiring Of 3 Afh Building At Afs Amla.

Issued by Statutory Bodies & Commissions/Committees · Betul, Madhya Pradesh
Tender Value
17.30 Lakhs
Estimated cost
Bid Submission
08 Feb 2025
0 days left
EMD
34600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Betul → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Re-Wiring Of 3 Afh Building At Afs Amla.; 1 Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. 2 Taking down old unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, isolators, etc and making good to disturbed surface complete all as specified and directed. 3 Taking down carefully copper/aluminium sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 4 Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and directed. 5 M & L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade IS-694 marked drawn through in and including heavy duty grade (ISI marked) PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the One light point controlled by one, one way switch 5 Amps. complete all as specified and directed. 6 All as per item No 5 above but One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed. 7 All as per item No 5 above butOne 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed. 8 All as per item No 5 above butOne 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed. 9 All as per item No 5 above butOne bell point controlled by one, bell switch 5 Amps complete all as specified and directed. 10 As per item No. 5 above but using 2.5 sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed. 11 As per item No. 5 above but using 4.0 sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) complete all as specified and directed. 12 S & F modular switch piano flush type, single pole, one way, 5/6 Amp single module complete all as specified and directed. 13 S & F modular switch piano flush type, single pole, one way, 15/16 Amp single module complete all as specified and directed. 14 S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. 15 S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. 16 S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. 17 S & F bell push modular 6 Amps single module complete all as specified and directed. 18 S & F ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed. 19 S & F lamp holder, PVC / polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed. 20 S & F bell electric ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed 21 S & F modular single phase AC motor starter switch 25 Amp, 240 volts, 2 module complete all as specified and directed. 22 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 23 S & F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. 24 S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. 25 S & F MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 26 S & F MCB single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 27 S & F MCB single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 28 S & F ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 29 S & F exhaust fan, steel body AC single phase 230 Volts of size 300mm sweep with, blades, frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 0.75 Sqmm three core from ceiling rose to exhaust fan forconnection complete all as specified and directed. 30 S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of size 0.75 sqmm complete all as specified and directed. 31 S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 32 S & F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 33 S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and necessary mounting arrangements alongwith provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including suitable dia GI pipe medium grade bracket 0.75 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. 34 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. (Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.) 35 Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/ passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for size 4 core x 16 Sqmm. 36 All as per item No 35 above but 3.5 core x 25 Sqmm complete all as specified and directed. 37 Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified and directed. 38 Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed. 39 Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. 40 Supply and laying HDPE DWC pipe size outer dia 50 mm, inner dia 38 mm for LT cable protection including sockets, bends etc complete all as specified and directed. 41 Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch A while deriving the Contract Sum for Acceptance.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Feb-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 08-Feb-2025

BOQ

Name of Work:RE-WIRING OF 3 AFH BUILDING AT AFS AMLA
Sl. No. Item Description
1Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed.
2Taking down old unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, isolators, etc and making good to disturbed surface complete all as specified and directed.
3Taking down carefully copper/aluminium sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
4Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and directed.
5M & L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade IS-694 marked drawn through in and including heavy duty grade (ISI marked) PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the One light point controlled by one, one way switch 5 Amps. complete all as specified and directed.
6All as per item No 5 above but One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed.
7All as per item No 5 above butOne 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed.
8All as per item No 5 above butOne 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed.
9All as per item No 5 above butOne bell point controlled by one, bell switch 5 Amps complete all as specified and directed.
10As per item No. 5 above but using 2.5 sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed.
11As per item No. 5 above but using 4.0 sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) complete all as specified and directed.
12S & F modular switch piano flush type, single pole, one way, 5/6 Amp single module complete all as specified and directed.
13S & F modular switch piano flush type, single pole, one way, 15/16 Amp single module complete all as specified and directed.
14S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed.
15S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
16S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
17S & F bell push modular 6 Amps single module complete all as specified and directed.
18S & F ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed.
19S & F lamp holder, PVC / polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed.
20S & F bell electric ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed
21S & F modular single phase AC motor starter switch 25 Amp, 240 volts, 2 module complete all as specified and directed.
22M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit
23S & F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed.
24S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed.
25S & F MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.
26S & F MCB single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.
27S & F MCB single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed.
28S & F ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed.
29S & F exhaust fan, steel body AC single phase 230 Volts of size 300mm sweep with, blades, frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 0.75 Sqmm three core from ceiling rose to exhaust fan forconnection complete all as specified and directed.
30S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of size 0.75 sqmm complete all as specified and directed.
31S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
32S & F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.
33S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and necessary mounting arrangements alongwith provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including suitable dia GI pipe medium grade bracket 0.75 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed.
34M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. (Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.)
35Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/ passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for size 4 core x 16 Sqmm.
36All as per item No 35 above but 3.5 core x 25 Sqmm complete all as specified and directed.
37Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified and directed.
38Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed.
39Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
40Supply and laying HDPE DWC pipe size outer dia 50 mm, inner dia 38 mm for LT cable protection including sockets, bends etc complete all as specified and directed.
41Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch \"A\" while deriving the Contract Sum for Acceptance.

AI Tender Summary

OUR REF NO 47163735
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 17.30 Lakhs
LAST DATE 08-02-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Re-Wiring Of 3 Afh Building At Afs Amla.; 1 Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. 2 Taking down old unserviceable distribution board by disconnection of electric connection carefully SPN DBs/ TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, isolators, etc and making good to disturbed surface complete all as specified and directed. 3 Taking down carefully copper/aluminium sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 4 Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and directed. 5 M & L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade IS-694 marked drawn through in and including heavy duty grade (ISI marked) PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the One light point controlled by one, one way switch 5 Amps. complete all as specified and directed. 6 All as per item No 5 above but One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator complete all as specified and directed. 7 All as per item No 5 above butOne 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed. 8 All as per item No 5 above butOne 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed. 9 All as per item No 5 above butOne bell point controlled by one, bell switch 5 Amps complete all as specified and directed. 10 As per item No. 5 above but using 2.5 sqmm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sqmm copper conductor FRLS PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed. 11 As per item No. 5 above but using 4.0 sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) complete all as specified and directed. 12 S & F modular switch piano flush type, single pole, one way, 5/6 Amp single module complete all as specified and directed. 13 S & F modular switch piano flush type, single pole, one way, 15/16 Amp single module complete all as specified and directed. 14 S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. 15 S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. 16 S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed. 17 S & F bell push modular 6 Amps single module complete all as specified and directed. 18 S & F ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed. 19 S & F lamp holder, PVC / polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed. 20 S & F bell electric ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed 21 S & F modular single phase AC motor starter switch 25 Amp, 240 volts, 2 module complete all as specified and directed. 22 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 23 S & F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. 24 S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and as directed. 25 S & F MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 26 S & F MCB single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 27 S & F MCB single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 28 S & F ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 29 S & F exhaust fan, steel body AC single phase 230 Volts of size 300mm sweep with, blades, frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 0.75 Sqmm three core from ceiling rose to exhaust fan forconnection complete all as specified and directed. 30 S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of size 0.75 sqmm complete all as specified and directed. 31 S & F in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 32 S & F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 33 S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and necessary mounting arrangements alongwith provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including suitable dia GI pipe medium grade bracket 0.75 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. 34 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. light grade protection pipe for earth lead complete with charcoal and common salt in alternate layer including watering arrangement with galvanized iron pipe medium grade 20mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. (Note: GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.) 35 Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, laid in trenches/ passing through pipe/duct or fixed to wall/pole etc., and connecting up complete all as specified and directed for size 4 core x 16 Sqmm. 36 All as per item No 35 above but 3.5 core x 25 Sqmm complete all as specified and directed. 37 Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr in depth for foundation etc or for laying pipe lines and cables and getting out as in looses/soft soil complete all as specified and directed. 38 Returning filling in including spreading leveling, watering and well ramming in layer not exe. 25 cm in soft/ loose soil, complete all as specified and directed. 39 Removing excavated material to a distance not exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. 40 Supply and laying HDPE DWC pipe size outer dia 50 mm, inner dia 38 mm for LT cable protection including sockets, bends etc complete all as specified and directed. 41 Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch A while deriving the Contract Sum for Acceptance.
Basic Detail
Tender No 8619/E8 OF 2024-25
Bidding Type Tender
Location
City Betul
State Madhya Pradesh
Key Dates
Publish Date 01 Feb 2025
Submission Date 08 Feb 2025
Open Date 10 Feb 2025
Finance
Tender Value 17.30 Lakhs
Tender Fee 500
EMD 34600
Exemption Available
Document List
Binder1.pdf
0d68688a-7cbc-4560-96bd-97d1ba0a8746.html
Tendernotice_1.pdf
BOQ_775662.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 01, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 08, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 08, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 10, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Binder1.pdf

html

0d68688a-7cbc-4560-96bd-97d1ba0a8746.html

pdf

Tendernotice_1.pdf

xls

BOQ_775662.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender