| 1 | M & L for Earth work in all kind of soil excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed. |
| 2 | Removal of excavated material (soil) to a distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 3 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed. |
| 4 | S & F Reinforced concrete pipes, class NP2, laid and jointed complete with collarsand tested as per manufactures instruction complete all as specified and directed. |
| 5 | All as per above item No 4.00 but Dia 150 MM |
| 6 | All as per above item No 4.00 but Dia 200 MM |
| 7 | M & Lfor 150mm diaSGSW drain pipes laid in trenches and jointed complete all as specified and directed. |
| 8 | M & Lfor Cement concrete 1:3:6, type C-2(Nominal mix) using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as specified and directed. |
| 9 | M & Lfor Brick work with sub class \"B\" bricks, old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed. |
| 10 | M & Lfor RandomRubblestone walling uncourses, built in CM (1:6) complete all as specified and directed. |
| 11 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm complete all as specified and directed. |
| 12 | S & F110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / newMS stack clamps ofFI 50 x 3mm complete all as specified and directed. |
| 13 | S & F75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including existing / newMS stack clamps ofFI 50 x 3mm complete all as specified and directed. |
| 14 | M & LConcrete bed to drain pipes including packing under and haunching against the sides of pipe as cradle afterr they are laid and tested in cement concrete 1:3:6 type C-2 (Nominal mix using20mm graded crushed stone aggregate for 150 mm bore pipes complete all as specified and directed. |
| 15 | M & LConcrete bed to drain pipes including packing under and haunching against the sides of pipe as cradle after they are laid and tested in cement concrete 1:3:6 type C-2 (Nominal mix using20mm graded crushed stone aggregate for 200 mm bore pipes complete all as specified and directed. |
| 16 | M & Lfor Plain Cement concrete 1:2:4 Type B0 using 12.5 mm graded crushed stone aggregate in coping, benching and the like including weathering, slightly rounded or chamfered angles as directed including form work and finishing all exposed surfaces complete all as specified and directed. |
| 17 | PCC (1:2:4) type B 0 using 12.5 mm graded stone aggregate as in drain and surface channel complete all as specified and directed. |
| 18 | Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stoppedends etc., complete all as specified and directed. |
| 19 | M & Lfor Rendering 15 mm thick on fair faces of brick/stone surfaces in cement mortar (1:4) finished even and faircomplete all as specified and directed. |
| 20 | M & Lfor Precast cement concrete type B-1, 1:1.5:3 (Nominal mix) using 20 mm grade crushed stone aggregate, as in cover slabs (for manhole etc.) casted at site and setting in cement mortar 1:4 complete all as specified and directed. |
| 21 | M & Lfor TMT bars (Fe 500), 10 mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed. |
| 22 | M & Lfor TMT bars (Fe 500), 6 to 8 mm dia and over in reinforcement cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed. |
| 23 | Cutting into existing manholes for removing existing branch drain, making good to pipe and rendering cutting out branch channel, and making goodfor 150 mm bore pipe complete all as specified and directed. |
| 24 | M & LforSeptic tank for 100 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brickwork in CM(1:3), RCC M-30 Design Mix in Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete allas specified and directed and as shown in Drg No. CEBZ/TD/76/2011 Sheet 1/1 & 1/2. |
| 25 | M & L for Soakage wells excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size (3.0 m dia x 3.0M deep) |
| 26 | M & LforSeptic tank for 50 users, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brickwork in CM(1:3), RCC M-30 Design Mix in Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete allas specified and directed and as shown in Drg No. CEBZ/TD/76/2011 Sheet 1/1 & 1/2. |
| 27 | M & L for Soakage walls excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size (2.40 m dia x 3.0M deep) complete allas specified and directed. |
| 28 | Demolition of cement concrete (unreinforeced) in ground floors and pavings n. exc 15cm thickness (below or above ground level) etc complete allas specified and directed. |
| 29 | M & Lfor 25mm thick cement concrete type B-1 1:2:4 (using 20mm graded stone aggregate) as in of flooringwithout using extra cement etc complete allas specified and directed. |
| 30 | M & Lfor vitrified ceramic tiles light shade 8-10mm thick (square / rectangular ) polished, area of each tiles exc 0.18 Sqm not exceeding 0.36 Sqm, in floor etc set and jointed in neat cment slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 etc complete allas specified and directed. |
| 31 | M & Lfor vitrified ceramic tiles light shade 8-10mm thick (square / rectangular ) polished, area of each tiles exc 0.18 Sqm not exceeding 0.36 sqm, in vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed plaster 10mm thick in CM 1:4 etc complete allas specified and directed. |
| 32 | Providing & Fixingfalse ceiling with Everest Fibre Cement Designer tile Ivory painted (High Pressure Steam Cured) of4mm thickness (as per IS:14862) of size 595x595 mm and any one of the design (oceanic, lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and 15x32 mm made from 0.30 mm thick sheet, spaced at 1200 mm c/c and cross \"T\" of size 15x32 mm made of 0.30 mm sheet, 1200mm long spaced between main \"T\" at 600 mm c/c to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size15x32 mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 15x20 mm made of 0.30 mm thick sheet and laying false ceiling tiles in the grid including , required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15mm of all T -sections shall be centra black pre-painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, including dismantling of old boards/ ciling etc complete at all heightscomplete allas specified and directed. |
| 33 | M & Lpreparationof old plastered surface of wall and applying onecoat of distemper oil emulsion / oil bound distemper over coat of 1mm thick average thick wall putty, complete all as specified and directed. |
| 34 | M & Lcutting holes in stone walls built in cement mortar or in cement lime mortar for inserting holdfasts and making good dismantled portion in cement concrete 1:2:4 type B-1 as required area exc one brick but not exc two bricks etc complete allas specified and directed. |
| 35 | S & F rolled mild steel as in angle setion, fixed indepenntly with or without connecting plates or welding with existing steel or iron surfaces etc and similar work confirming to Gde E-165 (Fe 290) including necessary cutting, welding etc and fixing in position etc complete allas specified and directed. |
| 36 | M & Lfor preparation of new steel and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete allas specified and directed. |
| 37 | M & Lfor point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cablein and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed inwalls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box andmodular white cover plate with frame for suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth for the following, etc complete all as specified and directed by Engr-in-Charge:- |
| 38 | All as per Item No 35.00 above but One light pointcontrolled by one way5 Amps SP switch |
| 39 | All as per Item No 35.00 above but One fan point controlled by one, one way switch. |
| 40 | S & Fof modular switch 1 way 6/10Amp , 1 module, etc complete allas specified and directed. |
| 41 | S & Fswitch piano flush type 5 amps, single pole one way 240 volts etc complete allas specified and directed. |
| 42 | S & Fceiling rose surface bakelite 3 terminals 63.5 x 17 mm etc complete allas specified and directed. |
| 43 | S & Fwall fan of size 450 mm sweep, Speed upto 1440 RPM, Air Delivery upto 125 CMM, upto 100 watt, 230/240 volts, metal body including connecting with three core copper wire from ceiling rose to connector of fan etc complete allas specified and directed.Make :- Havells/Crompton/Bajaj |
| 44 | Supply and fixingin repair recess mounted LED 12 watt Slim, compact, auminum die cast edge lit panel, round fixture with opal diffuser and separate electronic driver in warm white/cold white etc complete allas specified and directed. |
| 45 | Supply and fixing recess mounted 2\" x 2\"LED luminarie 36 watt, cool day/warm/ white light with white powder coated CRCA housing with LED driver, efficiencey >100 Lm/wetc complete allas specified and directed. |
| 46 | S&F installation, testing and commissioning of new water heater storage type outer, Rated wattage 2000, Capacity 25 Lts, High Pressure Rating 8 bar, Outer body material metal body, Inner Container Thickness not less than 1.8mm, Average Enamel layer thickness 0.50mm, Incoloy with glass coated Heated element, Inner Container (tank) material MS, ANODE Mg Rod, Voltage 230V-50Hz, Temperature Range 25-75 DDegree C., Type Verticle fixed with fastner of 6 inches set of 4 an with connection pipes of stainless steel SS 304 grade pack of with PTMT nuts of length 24 Inches and testing all as directed.Make :- Havells/ Usha/ Crompton/ Jaquar. |
| 47 | M & L for sub main wiring with 6 sqmm 2 core multi stranded copper conductor PVC insulated, sheathed, flame retardent, cable 1100 volts grade in PVC caping & casing ISI marked fixed on roof/cielling/wall all as per site requirement with all fixing arrangement like clamps screws, socket, bend etc as per IS including earth continuity conductor of size 6 sqmm single core copper conductor multistranded cable connected to common earth dolly, etc complete allas specified and directed. |
| 48 | S & F Sheet metal enclosures ac box with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug with socket complete with one single pole 20 Amp MCB etc complete allas specified and directed. |
| 49 | S & Fof MCB distribution board single pole & neutral with 200 Amps rated bus bar,double door IP-43 DB\"s , made outof sheet steel enclosure, recessed type, factory made powder coated4 way, 240 volts suitable for housing MCB\"s including blanking plate , etc complete allas specified and directed. |
| 50 | S & F of MCB SPN, 240 volt,36 to 63 Amp capacity, 10 KA, \"C\" curve, complete allas specified and directed. |
| 51 | S & FGI Tubes 15 mm dia medium grade with all fittings and fixed complete to walls/floors/trenches complete allas specified and directed. |
| 52 | S & FBib tap brass CP screwed for iron pipe of size 15 mm bore, complete allas specified and directed. |
| 53 | Cutting existing steel tubing for addition and alteration, screwing the existing steel tubing in position and insertion of required size of GI fittings. (i.e. union, nipple,reducing tee) for branch connection of internal dia 15 mm dia, complete allas specified and directed. |
| 54 | S & Fstop valve brass CP high pressure both ends screwed for iron pipe of size 15 mm dia, complete allas specified and directed. |
| 55 | Total in Figures |
| 56 | Quoted Amount in Words |