Installation Of Leaded Doors And Taking Out Windows From X-Ray Unit, Pedong Rh, Kalimpong Gta
Tender Value
1.14 Lakhs
Estimated cost
Bid Submission
18 Jan 2025
0 days left
EMD
2284
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
pedong → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Installation Of Leaded Doors And Taking Out Windows From X-Ray Unit, Pedong Rh, Kalimpong Gta
BOQ
| Sl. No. | Item Description |
| 1 | Installation of leaded Doors and taking out Ventilations fromX-Ray Unit, Kalimpong District Hospital , Kalimpong GTA. |
| 2 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m |
| 3 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damages complete |
| 4 | Ordinary Cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes.River Bazree |
| 5 | Reinforcement for reinforced concrete work in all sorts of structures including distribution of bar, stirups,binders etc. initial straightening and removing of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection complete as per drawing and direction. |
| 6 | Hire and Labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stoutprops and thick hard wood planks of approved thickness with required bracing for concrete slab, beams and columns,lintels curved or straight including fitting & fixing and striking out after completion of works |
| 7 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface. |
| 9 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC. |
| 10 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion |
| 11 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar, including rounding off corners or chamfering corners as directed and recking out joints or roughening of concrete surface with (4:1) cement morter 15 mm thick plaster |
| 12 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/Acrylic emulsion paint including scraping and preparingthe surface throughly,complete as per manufacture\"s specification and as per direction of the EIC. |
| 13 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 14 | Supplying & fitting of 55 mm thick asbestos free-fire, heat and smoke resistantcomposite Fire check Door Shutter complying with fire performance-FD 120 as per IS:3614 (part-II)-comprising of 2x8mmCalciumSilicate boards over Chemically treated (with Fire retardant chemicals in pressure impregnation vessels under 160psi pressureas per IS:401and kiln seasoned to moisture below 15% as per IS:1141 internal timber Malaysian Hard Wood, densified to 810kg/cum frame work of 100mmx32mm with 32 mm thick in fill of ceramic fiber (density128Kg/cum), vermaculite mix faced with 3mm Fire retardant High Density fire board on outer side & similar one over 3 mm thick protective lead covering conforming to ASTMB 749-03 for reducing the radiation level to 2 mre min 1 hour as stipulated by code of Federal Regulation (CFR),internally lipped with hard wood beading, and pasted in Hydraulic Press under 25MPa, spray coated with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush-Type in tumescent strip of size 10 mm x4mm affixed on peripheral slit on all edges of shutter except bottom for fire and smoke sealing, without any external lipping including fitting, fixing shutters in position but excluding the cost of hinges & other fittings as per direction of Engineer-in Charge complete in all respect. |
| 15 | Supplying & fitting of 55 mm thick asbestos free-fire, heat and smoke resistantcomposite Fire check Door Shutter complying with fire performance-FD 120 as per IS:3614 (part-II)-comprising of 2x8mmCalciumSilicate boards over Chemically treated (with Fire retardant chemicals in pressure impregnation vessels under 160psi pressureas per IS:401and kiln seasoned to moisture below 15% as per IS:1141 internal timber Malaysian Hard Wood, densified to 810kg/cum frame work of 100mmx32mm with 32 mm thick in fill of ceramic fiber (density128Kg/cum), vermaculite mix faced with 3mm Fire retardant High Density fire board on outer side & similar one over 3 mm thick protective lead covering conforming to ASTMB 749-03 for reducing the radiation level to 2 mre min 1 hour as stipulated by code of Federal Regulation (CFR),internally lipped with hard wood beading, and pasted in Hydraulic Press under 25MPa, spray coated with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush-Type in tumescent strip of size 10 mm x4mm affixed on peripheral slit on all edges of shutter except bottom for fire and smoke sealing, without any external lipping including fitting, fixing shutters in position but excluding the cost of hinges & other fittings as per direction of Engineer-in Charge complete in all respect in Ground Floor. |
| 16 | Supplying, fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors, of size EN-4 for leaf width upto 950/ 1100 mm weighing maximum 60/80kgs, CE certified, marked & conforming to EN1154-2003 of approved quality of reputed brand, complete as per direction & satisfaction of Engineer-in-Charge. |
| 17 | Supplying, fitting & fixing Stainless Steel \"D\" or \"H\" type of size 300 mm x 19 mmtubular Handle with Grade 304, CE certified, marked & conforming to EN 1154, of approved quality of reputed brand as per direction of Eingineer-in Chargefitted and fixed complete including allincidental charges. |
| 18 | Electrical works @15% |
| 19 | GST @ 18% |
| 20 | CESS @ 1% |
AI Tender Summary
Tender Timeline
Jan 10, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedJan 18, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 20, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender