| 1 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 volts grade, cross sectional area 240 sqmm. 3.5 core including suitable size lugs and glands complete all as specified and directed by Engr-in-charge. |
| 2 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 volts grade, cross sectional area 185 sqmm. 3.5 core including suitable size lugs and glands complete all as specified and directed by Engr-in-charge. |
| 3 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 volts grade, cross sectional area 70 sqmm. 3.5 core including suitable size lugs and glands complete all as specified and directed by Engr-in-charge. |
| 4 | M&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 volts grade, cross sectional area 50 sqmm. 3.5 core including suitable size lugs and glands complete all as specified and directed by Engr-in-charge. |
| 5 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes,taking out cable, etc not exceeding 10 sqm on plan and getting out in any type soil complete all as specified & directed by Engineer-in-Charge. |
| 6 | M&L sand cushioning to PVC cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-Charge. (Note :- For the purpose of payment only punned thickness will be measured). |
| 7 | Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge. |
| 8 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil complete all as specified & directed by Engineer-in-Charge. |
| 9 | Removing excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified and directed by Engineer-in-charge. |
| 10 | M&L PCC (1:3:6) type C-1 using 20mm graded stone aggregate in making good the road surfaces as its original position, n. exc. 10 cm in width and setting in mortar complete all as specified and directed by engineeer-in-charge. |
| 11 | M&L for GI tubing of size 100 mm light grade with all fittings laid in ternches for cable protection complete all as specified and directed by Engineer-in-charge. |
| 12 | M&L for boring in any type of soil under road 1.5 mtr below the top surface of road by conventional method complete for passing through 40 mm to 150 mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.Note :- Pipe will be paid and measured seperately. Any damage to existing cable/ pipe line of any type will made good by the contractor without any extra cost. |
| 13 | Note:- Schedule of credit as per availabilty at site, Contractor will not claim it during the execution of work. |