| 1 | Group-I Fabrication, fitment, welding of foundation, installation of equipment on bulkheads/ decks/ ceiling/ side panels, fitment of earth bolts for control Panel/ Eqpt. Like switches/ switch sockets/ light fixtures/ speakers/ sensors/ JBs etc. with shock mounts with weights of following categories |
| 2 | below 5Kg |
| 3 | above 5Kg and up to 10kg |
| 4 | Group-II -Erection of Gl Cable trays/ Flat bar/ single hangers with supports of following sizes (Width) including fasteners |
| 5 | MS Perforated cable tray 50Wx30Hx2500Lx1.6t |
| 6 | MS Perforated cable tray 75WX30Hx2500Lx1.6t |
| 7 | MS Perforated cable tray 100Wx30Hx2500Lx1.6t |
| 8 | MS Perforated cable tray 150Wx30Hx2500Lx1.6t |
| 9 | Group-III- Cable laying Works including temporary strapping for different sizes |
| 10 | Group-III A- POWER CABLES (Cross section wise) |
| 11 | CS ≤ 1.5 Sq.mm |
| 12 | CS = 2.5 & 4 Sq.mm |
| 13 | CS = 6 & 10 Sq.mm |
| 14 | CS = 16 & 25 Sq.mm |
| 15 | CS = 35 & 50 Sq.mm |
| 16 | CS = 70 & 95 Sq.mm |
| 17 | CS = 120 sq.mm |
| 18 | CS > 120 sq.mm |
| 19 | Group-III B- CONTROL CABLES(Cross section wise) |
| 20 | CS ≤ 0.75 Sq.mm |
| 21 | CS = 1 & 1.5 Sq.mm |
| 22 | CS = 2.5 Sq.mm |
| 23 | Communication Cables like co-axial / telephone/ RF/ RJ/ CAT-6/ CAT-6A/ CAT-7/ CAT-8 Cables |
| 24 | Optical fibre Cable(OFC) |
| 25 | Group-IV - Cable glanding, termination/ crimping/ splicing (including supply of printed ferrules, lugs and installation of cable tallies) |
| 26 | Group-IV A - POWER CABLES (Cross section wise) |
| 27 | CS ≤ 1.5 Sq.mm |
| 28 | CS = 2.5 & 4 Sq.mm |
| 29 | CS = 6 & 10 Sq.mm |
| 30 | CS = 16 & 25 Sq.mm |
| 31 | CS = 35 & 50 Sq.mm |
| 32 | CS = 70 & 95 Sq.mm |
| 33 | CS = 120 sq.mm |
| 34 | CS > 120 sq.mm |
| 35 | Group-IV B - CONTROL CABLES (Cross section wise) |
| 36 | CS ≤ 0.75 Sq.mm |
| 37 | CS = 1 & 1.5 Sq.mm |
| 38 | CS = 2.5 Sq.mm |
| 39 | Communication Cables like co-axial /telephone /RF/RJ/CAT-6/CAT-6A/CAT-7/CAT-8 Cables |
| 40 | Splicing for FO cables |
| 41 | Group-V-Cable dressing on trays/ perforatedflat-bars/ SCHs(Including supply of PVC coated SS straps, buckles & wing clips) |
| 42 | Tie on Main Cable Hangers (>100 mm wide) |
| 43 | Tie on Perforated trays/ flat bars (< 100 mm wide) |
| 44 | Group-VI- Securing of cable through Flexible conduit along with clamping(including supply of conduit) |
| 45 | Flexible SS up to 25 mm |
| 46 | Flexible SS 25 mm to 100 mm |
| 47 | Flexible SS above 100 mm |
| 48 | Group-VII- Erection of single pack glands (including supply of material) |
| 49 | SP Gland upto 25 mm |
| 50 | SP Gland above 25 mm upto 50 mm |
| 51 | SP Gland above 50 mm |
| 52 | Group-VIII- Erection of Goose neck pipes after opening of Deck, edge preparationand fit-up of the pipe |
| 53 | Goose neck pipe of size upto 50 mm ID |
| 54 | Goose neck pipe of size above 50 mm ID |
| 55 | Group- IX -Coaming sealing/ filling of following sizes (H x W x L x t) |
| 56 | 100x 200x 200X8 and below |
| 57 | Above 100x 200x 200 x8 and up to 200x 200 x200x 8 |
| 58 | Above 200 x200x 200 x8 and up to 200x 400x 200x 8 |
| 59 | Above 200x 400 x200x 8 and up to 200x 600x 200x 8 |
| 60 | Above 250 x200x 200 x8 and up to 250x 400x 200x 8 |
| 61 | Above 200x 400 x200x 8 and up to 200x 600x 200x 8 |
| 62 | 200x 600 x200x 8 and above |
| 63 | Group- X - Pipe Coaming sealing/ filling of following sizes |
| 64 | Pipe coamings upto 100 mm ID |
| 65 | Pipe coamings above 100 mm ID |
| 66 | Group- XI -MCT Coaming sealing/ filling of following sizes |
| 67 | SRC 2x1 (140 x 118) |
| 68 | SRC 2x1_EX (140 x 118_Ex) |
| 69 | SRC 6x1 (140 x 238) |
| 70 | SRC 6x2 (270 x 238) |
| 71 | SRC 6x2_EX (270 x 238_Ex) |
| 72 | SRC 6x3 (400 x 238) |
| 73 | SRC 6x3_EX (400 x 238_Ex) |
| 74 | SRC 8x2 (270 x 298) |
| 75 | SRC 8x3 (400 x 298) |
| 76 | SRC 8x4 (532 x 298) |
| 77 | Single Cable MCT Upto 34mm |
| 78 | Single Cable MCT 34mm to 60mm |
| 79 | Group-XII-Erection of metal Casing capping of following sizes on side/ ceiling panels in accommodation spaces |
| 80 | upto 25 mm |
| 81 | above 25 mm to 50 mm |
| 82 | above 50 mm |
| 83 | Group-XIII-Supply & installation of Bond straps as per NECP 500 standard& MIL-STD-1310H |
| 84 | Type 1 |
| 85 | Type 2 |
| 86 | Type 3 |
| 87 | Type 4 |
| 88 | Group-XIV-Supply & installation of 1.5 mm thick Metallic (SS anodized) equipment tallies/ service tallies |
| 89 | Size upto 75 mm X 20 mm |
| 90 | Size above 75 mm X 20 mm |
| 91 | Group-XV- Completion of IIs, STW, Commissioning, HATs, SATs and remark liquidation of all Systems [List of system wise weightages is attached at Table.3 of Annexure I. Payment will be made at actuals] |
| 92 | Group-XVI - Deployment of manpower |
| 93 | Group-XVI-A-For MSB manning per shift |
| 94 | Skilled manpower |
| 95 | Group-XVI-B-For Sea trials |
| 96 | Un skilled manpower |
| 97 | Skilled manpower |
| 98 | Group-XVI-C-For deep cleaning works |
| 99 | Un skilled manpower |
| 100 | Group-XVI-D-For any other works |
| 101 | Un skilled manpower |
| 102 | Skilled manpower |
| 103 | Group-XVII-Supply of glands |
| 104 | PG 7 - PG 13.5 |
| 105 | PG 16 - PG 29 |
| 106 | PG 36 - PG 63 |
| 107 | Note: the quantities mentioned in the above table are indicative, the requirement of quantities can be increased up-to 100% on the actual production progress during course of tender execution period. |