Tender For Miscellaneous Repair Of Control Room, Water Proofing Treatment Of Sub Division Office And Other Repair Of Sanitary Works At 33 Kv S/S Riico Kaladera - 1 PART-A (Bldg.) 2 1.28Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr. : All kinds of soil 3 1.8Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 4 3.1.6 & 3.1.2 Providing & Laying in position cement concrete i/c curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering – All work up to plinth level.: (A) 1:4:8 (1 cement:4 course sand: 8 graded stone aggregate 40 mm nominal size). 5 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 6 6.1.6/B-6Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:l in Cement sand Mortar 1:6 (1- Cement: 6- Sand). 7 12.3.2/B-12Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: (A) 20mm thick 8 3.8/B-3P/F precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specifications 50mm 9 12.22.1Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete.(A)New plastered surface (three or more coats) 10 12.37.1 /B-12Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: (A) New work (two or more coats) over and i/c scrapping and priming coat with cement primer. 11 12.42/B-12Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 12 12.46.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: (A) Two or more coats on new work. 13 Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. (15.28.1) 14 13.1Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead :With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 15 13.29Repair to damaged RCC slabs, beams and columns etc for strengtheing with cement mortar 1 : 2 in following stepsi) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.ii) Applying Epoxy primer on the exposed steel bars.iii) Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.vi) Cure the plastered surface for 15 days All work including scaffolding etc. complete in all respect. 16 2.7.3 /S-2P & F Bib cock (IS: 8931 Mark), Superior quality of approved make:(A) C.P. brass bib cock 15mm nominal bore. 17 (B) C.P. Brass Long body, 15mm nominal bore weight not less than 690 gm (2.7.4) 18 2.12.1/S-2P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. inlet connection 15mm Brass(Is: 8931 marked) 19 2.13.2/S-2P &F 15mm Dia Connection Pipe of approved quality/make PVC pipe with C.P. brass nuts upto length, 370mm 20 2.15.2 /S-2P & F Full - way Valve (IS: 778 Mark) or wheel valve of approved make:(A) Gun metal 20 mm nominal bore 21 P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia.(1.48.1) 22 2.6.1/SP & F Pilllar Cocks (IS :8934 Mark) of superior quality and approved make:C.P. Pillar cock, 15 mm dia nominal bore 23 3.16.2 /S-3P & F rigid PVC pipe ( IS: 4985 make) class II/(4 Kg./Cm2). Approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant.(A) 75 mm dia 24 (B) 110mm dia. (3.16.3) 25 3.3.1/SProviding & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) upto haunches of S.W. pipes including 150 mm thick bed concrete (Width W= Dia of pipe in Cm+ 30Cm.) concrete width to be reduced from width W at center of pipe to `0` at top of pipe.(Excluding cost of pipe) 100mm dia S.W. pipe 26 3.17.9,3.17.12 & 3.17.4,3.17.10/S-3P & F rigid PVC pipe fitting ( IS: 4985 make) of approved quality /make including jointing the pipe with solvent cement rubber ring and lubricant.(A) Bend 87.5 75mm dia 27 (B) Bend 87.5 110mm dia 28 3.19.1/s-3Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 29 3.21.1Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 300 X 300 mm depth upto 0.5 MCement cover with frame. 30 2.39.2/SProviding and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).(A) 20mm nominal outer dia pipes 31 (B) 25mm nominal outer dia pipes (2.39.3) 32 E 1.1.1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR(A) Short point (up to 3 mtr.) 33 (B) Medium point (up to 6mtr). (E1.1.2) 34 (C) Long point (up to 10mtr).(E1.1.3) 35 E 1.3.1Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRon board. 36 E 4.1.7Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR(A) 2 X 2.5 sqmm.+ 1x1.5 sqmm. 37 (B) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (E 4.1.14) 38 7.36Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works withGalvanized box of 1.2 mm thickwith earth terminal with suitable size phenolic laminated sheet (IS : 2036 -1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outletmaking connection , testing , etc. as required. . For specification ofWiring accessories refer ChapterE - 07 related item &For additional technical parameters of product / work refer Annexure A attached with this BSR 39 6.1.1.2Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 6A to 32 A rating.single pole mcb 40 6.2.1.2Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 63 A rating 41 15.7.3Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 42 17.1.1Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 43 18.12.6Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LED Street Light fixture with Minimum lumen output 11225 lm 44 LED Street Light fixture with Minimum lumen output 2450 lm (18.12.1) 45 11.2.1.1Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0 Sq. mm X 2 core (11.2.1.1)