| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in charge dsr 15.32023 |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge dsr 2023 .15.7.4 In cement mortar |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Ofarea beyond 3 sq. metres |
| 5 | Excavation in foundation in ordinary soil (loam ,clay or sand )including lift upto 1.5m |
| 6 | filling available excavatedearth into trenchs plinth , sides of foundation DSR SI NO.2.25 |
| 7 | Sand filling in plinth supply for necessaryquality of sand from any distance at site of work and including watering and dressing etc. required for proper completion of work SOR 2022 SI NO. 255 |
| 8 | Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. |
| 9 | Supplying chemical emulsion in sealed containers including delivery as specified hlorpyriphos/ Lindane emulsifiable concentrate of 20% dilution and injecting chemical emulsion for POST-CONSTRUCTIONALanti-termite treatment (excluding the cost of chemical emulsion): DSR 2023 2.34.1 |
| 10 | (Construction of Granular Sub Base byproviding close graded material, spreadingin uniform layers with motor grader onprepared surface, mixing by mix in placemethod with front end loader at OMC, andcompacting with vibratory roller to acheivethe desired density, complete As perMORTH Specification 401/SI No 4.1 |
| 11 | Providing and laying cement concrete|in 1:4:8 (1 Cement: 4 Coarse sand|8 graded stone aggregate 40 mm |nominal size) including supply of alll(|materials, labour and T&P etc.required for proper completion of thework. in Foundation and floors. SOR 275 a |
| 12 | RCC Work withattached pilaster, buttresses, plinth and string courses, fillet,including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size)upto plinth level UPPWD SOR 2022SI no 5.2.2 (i) |
| 13 | RCC Work withforBeam suspended floor roof having slope upto 15 degree landing balconies shelves chajjas lintels band plain window sill staircase and spiral stair cases above plinth level upto floor five level including the cost of centering shuttering finishing and excluding reinforcement with1:1.5:3(1Cement:1.5Coarse sand:3Stone Aggregate 20mm nominal size) UPPWD SOR 2022SI no 5.3 |
| 14 | Steel reinforcementThermo-Mechanically Treated bars of grade Fe-500D or more dsr 2023 5.22A.6 |
| 15 | Brick work with common burn clay F.P.S (non modular ) brickof class desingnation 7.5 in foundation and plinth in 1:4 (1cement:4 coarse sand) SOR 2022 Sl NO.6.1.1 |
| 16 | Brick work with common burn clay F.P.S (non modular ) brickof class desingnation 7.5 in superstructure above plinth leveup to floor v level in all shape and sizes in 1:4 (1 cement:4coarse sand) SOR-2022 SI NO.6.4.1 |
| 17 | |115 mm thick brick work in superstructure in 1:3 (1cement:3coarse sand) SOR- 2022 SI NO.6.12.1 |
| 18 | (12mm thick cement plaster of mix 1:4 (1 cement:4 coarsesand)_SOR 2022 SI No 584 |
| 19 | [15mm thick cement plaster of mix 1:4 (1 cement:4 coarsesand)_SOR 2022 SI No 2New |
| 20 | Smooth finishing of exposed surface of rcc work 6mm thickcement mortar(1:3) SOR 2022 SI No 13.16.1 |
| 21 | Providing and fixing glazing in fire resistant door shutters fixed panels& partitions etc., with G.l. beading made out of 1.6 mm thick G.l. sheet(zinc coating not less than 120 gm/sqm) of size 20 x 33 mm screwedwith M4 x 38 mm SS screws at distance 75 mm from the edges and150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.l. beading, & specialceramic tape of 5 x 20 mm size etc complete in all respect as per NBC2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-chargewith glass of required thickness having 60 minutes of fire resistanceboth integrity & radiation control (EW60) and minimum 20 minutes ofinsulation (E120). The manufacturer have to give test report/certificationof fire glass and the glass should have the stamp showing the value ofE, EW & El. The glass shall be tested in approved NABL accredited labor by any other accreditation body which operates in accordance withISO/IEC 17011 and accredits abs as per ISO/IEC 17025 for testing andcalibration scopes shall be eligible. The maximum glazing size shall not be more than 1100×2200mm (w×h) or 2.42 sqm. DSR 2023 9.138 |
| 22 | Providing and fixing panic bar / latch (Double point) fited with a singlebody, Trim Latch & Lock on back side of the Panic Latch of reputedBrand and manufacture to be approved by the Engineer- in- charge, alcomplete. Dsr2023 9.139 |
| 23 | Providing and Fixing factory made uPVC door frame, made of uPVCexturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm(t 0.2 mm), corners of the door frame to be mitred cut and jointedwith plastic brackets and stainless steel screws, reinforcing hinge sidevertical of the frames with PVC profile of Size 28 mm x 30 mm havingwall thickness 2 mm (+0.2 mm), including providing & fixing 3 nos of 125mm long stainless steel hinges to the frame, fixing the frame with jambwith required number & size of anchor dash fastners, all complete as permanufacturer\"s specification and direction of Engineer-in-charge.dsr9.143 |
| 24 | WOODEN DOOR :- Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 25 | UPVC WORK UPVC WINDOW :-Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to Upvc profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two Nos glazed & one Nos wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 26 | Providing and fixing glass strips of 4mm thick in joint of floor and skirting at the time for laying including labour T&P etc. (3.5 cm depth and 5mm thickness) SI No 631(d) SOR 2022 |
| 27 | Cement concrete flooring with 1:2:4 (1 Cement : 2 Coarse Sand: 4 Stone Aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete (40mm thick floor with 20mm nominal size stone ggregate) SI No 11.3.1 SOR 2022 |
| 28 | WALL TILES WASH ROOM :- Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 29 | 18.10 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall 20mmdia nominal bore DSR 18.10.2 |
| 30 | Providing and fixing brass bib cock of approved quality 15MM DIA nominal bore |
| 31 | 17.25 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :17.25.1 Flat back wash basin of size 630x450 mm |
| 32 | 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 17.28.2.1 32 mm dia |
| 33 | 17.15 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 34 | 17.19 Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete. 17.19.1 10 litre (full flush) capacity-white |
| 35 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively |
| 36 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick(galvanized @ 120 gram per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of theWith fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles. |
| 37 | Supply and fixing of 25mm dia pvc conduit pipe. Electricaldsr 2023 si no. 1.21.2 |
| 38 | Providing and fixing hexagonal fan box DSR 2023 SI NO.10.18 |
| 39 | Painting with Distempring 1st quality acrylic distemper (readymixed)_SOR 2022 SI No (649+2x650) |
| 40 | Providing and applying white cernent based puty of averagethickness 1mm of approved brand and manufacturer,over theplastered wall s urface to prepared the surface even thesmooth complete.SOR 2022 SI No13.80 |
| 41 | Providing and laying DPC 40MM thick with cement concrete1:2:4 SOR 2022 SI No 361(b) |
| 42 | Forming groove of uniform size in the top layer of washedstone grit plaster in 15mm wide and 15mm deep size.DSR2023.SI NO.13.73. |
| 43 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.) trusses etc.,including cutting, hoisting, fixing in position and applyinga priming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete.Dsr10.16.2Hot finished seamless type tubes |